913 resultados para Conners’ parent rating scale
Resumo:
Previous genetic analyses of psychosis proneness have been limited by their small sample size. For the purposes of large-scale screening, a 12-item questionnaire was developed through a two-stage process of reduction from the full Chapman and Chapman scales. 3685 individuals (including 1438 complete twin pairs) aged 18–25 years and enrolled in the volunteer Australian Twin Registry returned a mail questionnaire which included this psychosis proneness scale and the Eysenck Personality Questionnaire. Despite the brevity of the questionnaire, item and factor analysis identified four unambiguous and essentially uncorrelated scales. There were (1) Perceptual Aberration – Magical Ideation; (2) Hypomania – Impulsivity/Nonconformity; (3) Social Anhedonia and (4) Physical Anhedonia. Model-fitting analyses showed additive genetic and specific environmental factors were sufficient for three of the four scales, with the Social Anhedonia scale requiring also a parameter for genetic dominance. There was no evidence for the previously hypothesised sex differences in the genetic determination of psychosis-proneness. The potential value of multivariate genetic analysis to examine the relationship between these four scales and dimensions of personality is discussed. The growing body of longitudinal evidence on psychosis-proneness suggests the value of incorporating this brief measure into developmental twin studies.
Resumo:
Supervisor ratings are useful criteria for the validation of selection instruments but maybe limited because of the presence of rating errors, such as halo. This study set out to show that supervisor ratings which are high in halo remain successful criteria in selection. Following a thorough job analysis, a customer service questionnaire was designed to assess the potential of retail sales staff on three orthogonal subscales labelled Dealing with people, Emotions and energy, and Solitary style. These subscales were uncorrelated with supervisor ratings made about 8 weeks later. However, the supervisor ratings were correlated with an overall scale derived from the three scales of the customer service questionnaire. These results support the view that supervisor ratings generally consist of global impressions and suggest that these global impressions are useful measures of overall performances. This field study confirms laboratory results that halo does not necessarily reduce rating accuracy.
Resumo:
Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.
Resumo:
A new ball mill scale-up procedure is developed which uses laboratory data to predict the performance of MI-scale ball mill circuits. This procedure contains two laboratory tests. These laboratory tests give the data for the determination of the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of the full-scale mill circuit. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw. A worked example shows how the new ball mill scale-up procedure is executed. This worked example uses laboratory data to predict the performance of a full-scale re-grind mill circuit. This circuit consists of a ball mill in closed circuit with hydrocyclones. The MI-scale ball mill has a diameter (inside liners) of 1.85m. The scale-up procedure shows that the full-scale circuit produces a product (hydrocyclone overflow) that has an 80% passing size of 80 mum. The circuit has a recirculating load of 173%. The calculated power draw of the full-scale mill is 92kW (C) 2001 Elsevier Science Ltd. All rights reserved.
Model-based procedure for scale-up of wet, overflow ball mills - Part III: Validation and discussion
Resumo:
A new ball mill scale-up procedure is developed. This procedure has been validated using seven sets of Ml-scale ball mil data. The largest ball mills in these data have diameters (inside liners) of 6.58m. The procedure can predict the 80% passing size of the circuit product to within +/-6% of the measured value, with a precision of +/-11% (one standard deviation); the re-circulating load to within +/-33% of the mass-balanced value (this error margin is within the uncertainty associated with the determination of the re-circulating load); and the mill power to within +/-5% of the measured value. This procedure is applicable for the design of ball mills which are preceded by autogenous (AG) mills, semi-autogenous (SAG) mills, crushers and flotation circuits. The new procedure is more precise and more accurate than Bond's method for ball mill scale-up. This procedure contains no efficiency correction which relates to the mill diameter. This suggests that, within the range of mill diameter studied, milling efficiency does not vary with mill diameter. This is in contrast with Bond's equation-Bond claimed that milling efficiency increases with mill diameter. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
The paper considers the structural identifiability of a parent–metabolite pharmacokinetic model for ivabradine and one of its metabolites. The model, which is linear, is considered initially for intravenous administration of ivabradine, and then for a combined intravenous and oral administration. In both cases, the model is shown to be unidentifiable. Simplification of the model (for both forms of administration) to that proposed by Duffull et al. (1) results in a globally structurally identifiable model. The analysis could be applied to the modeling of any drug undergoing first-pass metabolism, with plasma concentrations available from drug and metabolite.
Resumo:
The Australian Coal Industry Research Laboratory (ACIRL) furnace is scaled to simulate slagging and fouling in operating boilers. This requires that the gas and target temperatures, the heat flux, and the flow pattern be the same as those in real boilers. The gas and target temperatures are maintained by insulating the wall and cooling the target respectively. The flow pattern of a small burner cannot be the same as a large furnace. However, this flow pattern is partially compensated for by placing the slagging panels in three vertical locations. The paper develops the models of radiant heat transfer from the flame to the deposits both in pilot-scale and full-scale furnaces. They are used to compare the effective radiant heat transfer of the pilot- and full-scale furnaces. The experimental data both from the pilot- and full-scale furnaces are used to verify the incident heat flux and temperature profiles in the pilot- and full-scale furnaces. The results showed that the thermal condition in the pilot-scale furnace meets the requirements for studying the slagging regarding the gas temperature and the incident heat flux, particularly for the panel #1. The gas temperature in the convective section also meets the requirement for studying the fouling.
Resumo:
Dispersal, or the amount of dispersion between an individual's birthplace and that of its offspring, is of great importance in population biology, behavioural ecology and conservation, however, obtaining direct estimates from field data on natural populations can be problematic. The prickly forest skink, Gnypetoscincus queenslandiae, is a rainforest endemic skink from the wet tropics of Australia. Because of its log-dwelling habits and lack of definite nesting sites, a demographic estimate of dispersal distance is difficult to obtain. Neighbourhood size, defined as 4 piD sigma (2) (where D is the population density and sigma (2) the mean axial squared parent-offspring dispersal rate), dispersal and density were estimated directly and indirectly for this species using mark-recapture and microsatellite data, respectively, on lizards captured at a local geographical scale of 3 ha. Mark-recapture data gave a dispersal rate of 843 m(2)/generation (assuming a generation time of 6.5 years), a time-scaled density of 13 635 individuals * generation/km(2) and, hence, a neighbourhood size of 144 individuals. A genetic method based on the multilocus (10 loci) microsatellite genotypes of individuals and their geographical location indicated that there is a significant isolation by distance pattern, and gave a neighbourhood size of 69 individuals, with a 95% confidence interval between 48 and 184. This translates into a dispersal rate of 404 m(2)/generation when using the mark-recapture density estimation, or an estimate of time-scaled population density of 6520 individuals * generation/km(2) when using the mark-recapture dispersal rate estimate. The relationship between the two categories of neighbourhood size, dispersal and density estimates and reasons for any disparities are discussed.
Resumo:
Performance indicators in the public sector have often been criticised for being inadequate and not conducive to analysing efficiency. The main objective of this study is to use data envelopment analysis (DEA) to examine the relative efficiency of Australian universities. Three performance models are developed, namely, overall performance, performance on delivery of educational services, and performance on fee-paying enrolments. The findings based on 1995 data show that the university sector was performing well on technical and scale efficiency but there was room for improving performance on fee-paying enrolments. There were also small slacks in input utilisation. More universities were operating at decreasing returns to scale, indicating a potential to downsize. DEA helps in identifying the reference sets for inefficient institutions and objectively determines productivity improvements. As such, it can be a valuable benchmarking tool for educational administrators and assist in more efficient allocation of scarce resources. In the absence of market mechanisms to price educational outputs, which renders traditional production or cost functions inappropriate, universities are particularly obliged to seek alternative efficiency analysis methods such as DEA.
Resumo:
Effluent water from shrimp ponds typically contains elevated concentrations of dissolved nutrients and suspended particulates compared to influent water. Attempts to improve effluent water quality using filter feeding bivalves and macroalgae to reduce nutrients have previously been hampered by the high concentration of clay particles typically found in untreated pond effluent. These particles inhibit feeding in bivalves and reduce photosynthesis in macroalgae by increasing effluent turbidity. In a small-scale laboratory study, the effectiveness of a three-stage effluent treatment system was investigated. In the first stage, reduction in particle concentration occurred through natural sedimentation. In the second stage, filtration by the Sydney rock oyster, Saccostrea commercialis (Iredale and Roughley), further reduced the concentration of suspended particulates, including inorganic particles, phytoplankton, bacteria, and their associated nutrients. In the final stage, the macroalga, Gracilaria edulis (Gmelin) Silva, absorbed dissolved nutrients. Pond effluent was collected from a commercial shrimp farm, taken to an indoor culture facility and was left to settle for 24 h. Subsamples of water were then transferred into laboratory tanks stocked with oysters and maintained for 24 h, and then transferred to tanks containing macroalgae for another 24 h. Total suspended solid (TSS), chlorophyll a, total nitrogen (N), total phosphorus (P), NH4+, NO3-, and PO43-, and bacterial numbers were compared before and after each treatment at: 0 h (initial); 24 h (after sedimentation); 48 h (after oyster filtration); 72 h (after macroalgal absorption). The combined effect of the sequential treatments resulted in significant reductions in the concentrations of all parameters measured. High rates of nutrient regeneration were observed in the control tanks, which did not contain oysters or macroalgae. Conversely, significant reductions in nutrients and suspended particulates after sedimentation and biological treatment were observed. Overall, improvements in water quality (final percentage of the initial concentration) were as follows: TSS (12%); total N (28%); total P (14%); NH4+ (76%); NO3- (30%); PO43-(35%); bacteria (30%); and chlorophyll a (0.7%). Despite the probability of considerable differences in sedimentation, filtration and nutrient uptake rates when scaled to farm size, these results demonstrate that integrated treatment has the potential to significantly improve water quality of shrimp farm effluent. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
This paper examines the psychometric quality of the Early/Late Preferences Scale (PS) relative to that of the Composite Morningness Scale (CS). Questionnaires were completed by 670 undergraduate students aged 16-37 years (mean 22.5), of whom 64% were female. Both scales displayed satisfactory inter-item correlations and similar total mean scores to those reported previously, although the CS had higher variability. Principal axis factor analysis produced single-factor solutions for both scales, although loadings for Items 7 and 9 on the PS were low. Internal consistencies for both scales were good (PS=0.86, CS=0.90) with only a small improvement achieved by deleting Items 7 and 9 from the PS. Test-retest reliability over 11 weeks was good for both scales (PS=0.92, CS=0.89). Differences between morning, evening and intermediate groups in self-rated alertness at different times of day, and significant correlations with other indices of morning-evening orientation, provided evidence of validity for both scales. These results indicate that PS is psychometrically comparable with CS. In view of its simpler format and lower cultural specificity, PS may be considered a preferable measure for most applications.