830 resultados para Commercially pure titanium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the fluoride (F) content in commercially available milk formulae in Brazil and to estimate the F intake in children from this source in the first year of life. Samples of cow's milk (n = 51), infant formulae (n = 15), powdered milk (n = 13), and soy-based products (n = 4) purchased in Araçatuba (Brazil) had their F content measured using an ion-specific electrode, after hexamethyldisiloxane-facilitated diffusion. Powdered milk and infant formulae were reconstituted with deionized water, while ready-to-drink products were analyzed without any dilution. Using average infant body masses and suggested volumes of formula consumption for infants 1-12 months of age, possible F ingestion per body mass was estimated. Data were analyzed by descriptive analysis. Mean F content ranged from 0.02 to 2.52 mg/L in all samples. None of the cow's milk provided F intake higher than 0.07 mg/kg. However, two infant formulae, one powdered milk, and one soy-milk led to a daily F intake above the suggested threshold for fluorosis when reconstituted with deionized water. Assuming reconstitution of products with tap water at 0.7 ppm F, two infant formulae, five powdered milk, and four soymilks led to daily F intake ranging from 0.108 to 0.851 mg/kg. The results suggest that the consumption of some brands of infant formulae, powdered milk, and soy-based milk in the first year of age could increase the risk of dental fluorosis, reinforcing the need for periodic surveillance of the F content of foods and beverages typically consumed by young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, crystalline titanium dioxide (TiO2) nanoparticles with variable average crystallite sizes (e.g., 8 nm) and surface areas (e.g., 192 m² g-1) were synthesized in pure anatase phase using H2O2 to reduce the hydrolysis rate of the titanium ions. An isopropanol (IP) solution was employed as the reaction medium. The TiO2 nanoparticles were characterized by powder X-ray diffraction analysis (XRD), Raman spectroscopy and transmission electron microscopy (TEM). By changing the synthesis parameters it was possible to control nanoparticle size and avoid the coalescence process. A dependence of the Raman wavenumber on the nanocrystal sizes was determined, which is quite useful for a quick check of the size of TiO2 nanocrystals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During clinical routine, the orthodontist uses several materials, which include metallic alloys in the form of metallic wires. However, it is necessary that the professional has some knowledge of the properties of those wires. Different types of wires are commercially available: stainless steel wires, chrome-cobalt wires, nickel-titanium wires and beta-titanium wires. Among the nickel-titanium wires, there are three subdivisions: a conventional alloy and two superelastic alloys. The superelasticity, associated to the effect of form memory, is a property used in orthodontics to initiate the dental movement in the first phase of the orthodontic treatment. This property is considered to be biologically compatible with the effective dental movement. These wires are available at the market in different transformation temperatures, and they offer the best adaptation in the groove of the bracket, simplicity and a faster treatment. However, they present little formability, and they don’t accept solder. They are also more onerous than other wires. Moreover, the low rigidity of these wires doesn’t allow them to be used for the retraction of the anterior teeth or closing of spaces. Therefore, the coherent use of superelastic orthodontic wires is recommended, accompanied by a detailed diagnosis and planning, so the result will be an efficient orthodontic correction, accomplished in a shorter period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orange juice is a rich source of flavonoids, mainly the flavanones hesperidin and narirutin, associated with health benefits in humans. The objective of this study was to analyze the uptake of flavonoids in humans after the consumption of two types of orange juice, fresh squeezed (fresh juice, FJ) and commercially extracted and pasteurized (processed juice, PJ). Preliminary measurements showed that the main flavanones in PJ were approximately three-fold higher than in FJ. This study involved healthy volunteers including 12 men and 12 women, aged 27 ± 6, with a BMI of 24 ± 3 kg/m2. Volunteers drank 11.5 mL/kg body weight of fresh orange juice, and after an interval of 30 days they drank the same quantity of pasteurized orange juice. Urine was collected from each volunteer during 24 hours following juice consumption. Urine metabolites were recovered by solid phase extraction, and measured by HPLC–ESI–MS. Analyses of the urine samples showed high concentrations of glucuronic acid and sulfate conjugates of hesperetin and naringenin. The data indicate that the concentrations of the flavanone metabolites following consumption of PJ were approximately three times higher than for FJ, thus matching the relative doses of these compounds in the juices provided to the volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main aim of this work was to study the simultaneous wear-corrosion of titanium (Ti) in the presence of biofilms composed of Streptococcus mutans and Candida albicans. Both organisms were separately grown in specific growth media, and then mixed in a medium supplemented with a high sucrose concentration. Corrosion and tribocorrosion tests were performed after 48 h and 216 h of biofilm growth. Electrochemical corrosion tests indicated a decrease in the corrosion resistance of Ti in the presence of the biofilms although the TiO2 film presented the characteristics of a compact oxide film. While the open circuit potential of Ti indicated a tendency to corrosion in the presence of the biofilms, tribocorrosion tests revealed a low friction on biofilm covered Ti. The properties of the biofilms were similar to those of the lubricant agents used to decrease the wear rate of materials. However, the pH-lowering promoted by microbial species, can lead to corrosion of Ti-based oral rehabilitation systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption behavior of the Tet-124 antimicrobial peptide and the Tet-124 peptide modified at the C- and N-terminus with the sequence glycine-3,4-dihydroxyphenylalanine-glycine (G-DOPA-G) on titanium surfaces was studied using quartz crystal micro balance with dissipation (QCM-D). At a low pH level (4.75) Tet-124 and Tet-124-G-DOPA-G form rigid layers. This is attributed to the electrostatic interactions of the positively charged lysine and arginine residues in the peptide sequence with the negatively charged titanium oxide layer. At an elevated pH level (6.9) Tet-124 shows a lower mass adsorption at the surface than Tet-124-G-DOPA-G. This is attributed to the interaction of the catechol due to the formation of complexes with the titanium oxide and titanium surface layer. The C terminal and N terminal modification with the sequence G-DOPA-G shows similar adsorption rate and mass adsorption coverage at saturation; however it is presented a more loosely layers on the G-DOPA-G-TeT-124. Fibroblast adhesion and the biocompatibility test of both the surfaces following modification with Tet-124-G-DOPA-G and the titanium alloy control showed similar results. In addition, no changes in the adhesion of E. coli bacteria due to the modification of the surface were detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral cavity is a complex environment where corrosive substances from dietary, human saliva, and oral biofilms may accumulate in retentive areas of dental implant systems and prostheses promoting corrosion at their surfaces. Additionally, during mastication, micromovements may occur between prosthetic joints causing a relative motion between contacting surfaces, leading to wear. Both processes (wear and corrosion) result in a biotribocorrosion system once that occurs in contact with biological tissues and fluids. This review paper is focused on the aspects related to the corrosion and wear behavior of titanium-based structures in the oral environment. Furthermore, the clinical relevance of the oral environment is focused on the harmful effect that acidic substances and biofilms, formed in human saliva, may have on titanium surfaces. In fact, a progressive degradation of titanium by wear and corrosion (tribocorrosion) mechanisms can take place affecting the performance of titanium-based implant and prostheses. Also, the formation of wear debris and metallic ions due to the tribocorrosion phenomena can become toxic for human tissues. This review gathers knowledge from areas like materials sciences, microbiology, and dentistry contributing to a better understanding of bio-tribocorrosion processes in the oral environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Física - IFT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate the corrosion resistance of Ti-30Ta alloy when subjected to different strain rates. Samples of the alloy Ti-30Ta were obtained from the melting of pure elements in the arc furnace in inert atmosphere (argon gas). Then, the samples were subjected to a thermal treatment and to cold worked to obtain bars. After forging, the samples were machined in accordance with ASTME9-09 standard for carried out compression tests. To microstructural characterization, samples were sectioned longitudinal and transversally and embedded in resin. After, the wet sanding and polishing were performed, followed by a chemical attack, in order to study the microstructure under an optical microscope. Microhardness was measured on the samples that were subjected to microstructural characterization by using microhardness tester. Phases were evaluated by x-rays diffraction. Corrosion tests were carried out to evaluate the influence of deformation on the corrosion resistance. Results show that microstructure was not influenced by deformation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With advances in health care, has been na increase of demand for material that could replace the functions of the human body parts, thus evolved biomedic prosthesis which today are responsible for the constant improvement of the quality of life. The Titanium alloys are widely used as implants due to its properties, like high mechanical resistance, biocompatibility and corrosion resistance, and the addition alloying elements like Zirconium, may improve some of those properties. Such properties are related to the microstructure and consequently to the type of processing performed. The purpose of this dissertation was to characterize the experimental alloy Ti15Zr after route of processsing and heat treatment in order to extend the knowledge about this alloy. The latter has been abtained by fusion of pure metals in a arc melting furnace with an inert argon atmosphere. The material has been homogenized in a tube furnace at 950ºC for 24h and cold worked by swaging, after that, bars with 10 mm of diameter were obtained by the process of rotary forging. The samples were solubilized at 900º C for 2 hours and quenched in water. After that, 4 samples were submitted to the aging, at 400º C, 450º C, 500º C and 550º C. The microstructure and phase analysis was done by optical microscopy and X-rays diffraction (XRD), the mechanical characterization was carried out by microhardness test and finally, evaluation of corrosion resistance of the alloy by electrochemical tests. The XRD and the optical microscopy made it possible to analyze that the heat treatment influenced the phase shifting from α to α', and probably affected the alloy hardness, at the first aged sample at 500º Chas been a sudden increase in the value of hardness, probably by appearance of omega phase, unwanted phase to the medical application duo to great fragility, and finally ... (Complete abstract click electronic access below)