949 resultados para Church plate
Resumo:
by J. Henry Lord
Resumo:
This paper will focus on three episodes of contemporary church-state relations in Georgia, in particular, the conflicting interaction between law and religion in the public space. The first episode will be an open confrontation between the church and the state over the law on Registration of Religious Minority organizations (2011) which allowed the religious minorities to freely register; second: the Law on Self-governance (2013) which Georgian Orthodox Church considered “a threat to territorial integrity of Georgia”; and lastly: the Law on Anti-discrimination (2014) which was deemed “legitimization of Sodomic sin”. By reflecting on the three examples where for the first time after the collapse of Soviet Union, the Georgian state openly confronted the church and made a decision notwithstanding its position, I will attempt to argue that the role of the Orthodox Church in influencing the law making process is in gradual decline. However, on the other hand, by presenting the results of an ethnographic study conducted in 23 eparchies and perishes in 7 regions of Georgia in 2014, I will also show that church has adapted to its declining role over policy making, and to regain its political influence it gradually started to employ a civic rather than ethno nationalist discourse on matters of religious freedom while engaging with government. The paper will suggest that both unilateral decision-making of the state and civic shift in the discourse of the church constitute an important change in understanding church-state dynamics in the post-communist Orthodox Christianity dominated society.
Resumo:
I will attempt to problematize the typologies of nationalism when applied to the Georgian context, particularly in relationship to nationalism of President Mikheil Saakashvili. I will argue that the state-driven nationalism of post-Rose Revolution government was a hybrid form of ethno-cultural and civic which had elements of ethnic particularism towards the Orthodox Church. By reflecting on the growing assistance of Western institutions to Georgia, I will problematize the extent to which the rise of American and European involvement in the region reinforced the perceptions of the “self” and the “other” among the religious elites since the Rose Revolution. By presenting field research data (interviews) gathered in 23 eparchies and perishes with religious clerics in 7 regions of Georgia, I will argue that religious nationalism in Georgia strengthened not in response to but as an outcome of President Saakashvili’s policies towards the church, and partially as a reaction to the growing dissatisfaction with Western institutions working in Georgia and Western governments’ response to the Russo-Georgian War of 2008. By reflecting on empirical material, the paper attempts to problematize an understanding of religious nationalism as a social movement, an instance of cultural autonomy and a source of identity (Friedland 2001). In response, I suggest viewing religious nationalism in post-communist Georgia as medium of material and political interests
Resumo:
2011 bis 2014 arbeitete eine gemischte Dialogkommission der Altkatholischen Kirchen der Utrechter Union und der Mar Thoma Syrian Church of Malabar. Sie erarbeitete drei Erklärungen zu Handen der Bischofskonferenzen der beiden Kirchen. Der vorliegende Beitrag bildet eine Einführung in diese Erklärungen aus christkatholischer Sicht. Er wird der Nationalsynode der Christkatholischen Kirche der Schweiz, die im Juni 2015 tagt, vorgelegt, und ggf. im WWW veröffentlicht.
Resumo:
We introduce a new boundary layer formalism on the basis of which a class of exact solutions to the Navier–Stokes equations is derived. These solutions describe laminar boundary layer flows past a flat plate under the assumption of one homogeneous direction, such as the classical swept Hiemenz boundary layer (SHBL), the asymptotic suction boundary layer (ASBL) and the oblique impingement boundary layer. The linear stability of these new solutions is investigated, uncovering new results for the SHBL and the ASBL. Previously, each of these flows had been described with its own formalism and coordinate system, such that the solutions could not be transformed into each other. Using a new compound formalism, we are able to show that the ASBL is the physical limit of the SHBL with wall suction when the chordwise velocity component vanishes while the homogeneous sweep velocity is maintained. A corresponding non-dimensionalization is proposed, which allows conversion of the new Reynolds number definition to the classical ones. Linear stability analysis for the new class of solutions reveals a compound neutral surface which contains the classical neutral curves of the SHBL and the ASBL. It is shown that the linearly most unstable Görtler–Hämmerlin modes of the SHBL smoothly transform into Tollmien–Schlichting modes as the chordwise velocity vanishes. These results are useful for transition prediction of the attachment-line instability, especially concerning the use of suction to stabilize boundary layers of swept-wing aircraft.
Resumo:
BACKGROUND Limited range of finger motion is a frequent complication after plate fixation of phalangeal fractures. The purpose of this study was to evaluate the results of plate fixation of extra-articular fractures of the proximal phalanx using current low-profile mini-fragment-systems. METHODS From 2006 to 2012, 32 patients with 36 extra-articular fractures of the proximal phalanx of the triphalangeal fingers were treated with open reduction and plate fixation (ORPF) using 1.2 and 1.5 mm mini-fragment systems. Patients presenting with open fractures grade 2 and 3 or relevant laceration of adjacent structures were excluded from the study. We retrospectively evaluated the rate of mal-union or non-union after ORPF, the need for revision surgery, for plate removal, and for tenolysis. Data were analyzed for further complications with regard to infections or complex regional pain syndrome (CRPS). RESULTS No infections were noted. Five patients developed transient symptoms of CRPS. Six weeks postoperatively, total active finger motion (TAM) averaged 183°, and all 32 patients underwent formal hand therapy. At the latest follow-up or at the time of plate removal, respectively, the mean TAM improved to 213°. Extension lag of proximal interphalangeal joints was found in 67 % of all fractured fingers. Secondary surgery was necessary in 14 of 32 patients (2 corrective osteotomies, 12 plate removals including 7 procedures explicitly because of reduced mobility). CONCLUSIONS Despite of new implant designs significant problems persist. Adhesions of extensor tendons leading to limited range of finger motion are still the most frequent complications after ORPF of proximal phalangeal fractures, even in absence of significant soft-tissue damage. LEVEL OF EVIDENCE Therapeutic, Retrospective, Level IV.
Resumo:
The Śaiva Siddhānta Church (ŚSC), based in Kauai HI, USA, has been holding rites of conversion to Hinduism since the 1960s. These rites include studying one’s “former” religion, officially declaring severance from it in the presence of a minister or mentor, choosing and officially adopting a new Hindu name as well as aligning with “the Hindu community”. Starting from here, this paper will address the question of community with respect to (1) the meanings of the term, (2) the idea of Hinduism as “a global religion” upheld by numerous “communities” worldwide and (3) the relevance of “community” in the conversion process. For doing so, I will draw on source material published by the Himalayan Academy, a branch of the ŚSC, in the global magazine Hinduism Today, in book publications and on their various websites.
Resumo:
Background: Recent research suggested thatreligious coping, based on dispositional religiousness and spirituality (R/S), is an important modulating factor in the process of dealing with adversity. In contrast to the United States, the effect of R/S on psychological adjustment to stress is a widely unexplored area in Europe. Methods: We examined a Swiss sample of 328 church attendees in the aftermath of stressful life events to explore associations of positive or negative religious coping with the psychological outcome. Applying a cross-sectional design, we used Huber’s Centrality Scale to specify religiousness and Pargament’s measure of religious coping (RCOPE) for the assessment of positive and negative religious coping. Depressive symptoms and anxiety as outcome variables were examined by the Brief Symptom Inventory. The Stress-Related Growth Scale and the Marburg questionnaire for the assessment of well-being were used to assess positive outcome aspects. We conducted Mann-Whitney tests for group comparisons and cumulative logit analysis for the assessmentof associations of religious coping with our outcome variables. Results: Both forms of religious coping were positively associated with stress-related growth (p < 0.01). However, negative religious coping additionally reduced well-being (p = 0.05, β = 0.52, 95% CI = 0.27–0.99) and increased anxiety (p = 0.02, β = 1.94, 95% CI = 1.10–3.39) and depressive symptoms (p = 0.01, β = 2.27, 95% CI = 1.27–4.06). Conclusions: The effects of religious coping on the psychological adjustment to stressful life events seem relevant. These findings should be confirmed in prospective studies.
Resumo:
OBJECTIVE Proximal femoral osteotomy with stable fixation and sufficient correction. Low complication rates due to exact preoperative planning. INDICATIONS Congenital or traumatic femoral neck pseudarthrosis. Coxa vara. CONTRAINDICATIONS None. In severe deformities, a single femoral osteotomy may not solve the problem; thus, additional correction, e.g., a pelvic osteotomy, is required. SURGICAL TECHNIQUE Correct planning of the correction angle. Lateral approach. Subperiosteal detachment of vastus lateralis muscle. Place guide wire on the femoral neck to judge anteversion. Insert positioning wire 5 mm distal to trochanteric physis. Insert 2.8 mm Kirschner wire in the femoral neck. Osteotomy of the femur after marking the rotation by Kirschner wires or oscillating saw. Slide LC plate over Kirschner wires. Replace Kirschner wires with screws. Reduction of the femoral shaft to the plate with bone forceps. Definitive fixation of the plate to the femoral shaft by cortex or locking screws. Readaptation of vastus lateralis muscle over the plate. POSTOPERATIVE MANAGEMENT Partial weightbearing for 4-6 weeks depending on the age of the patient without any external fixation (e. g. cast) is possible. RESULTS Recent studies support the authors' findings of sufficient correction and stable fixation after proximal femoral osteotomy with the LCP pediatric hip plate. Low complication rates and stable fixation.
Resumo:
OBJECTIVE Correction of all kind of deformities at the distal part of the femur (supracondylar). INDICATIONS Flexion, extension osteotomies, and varus or valgus, and external or internal rotation osteotomies, and shortening osteotomies of the distal femur or combined surgical procedures (e.g., extension and de-rotation osteotomy). CONTRAINDICATIONS Osteotomy through unknown bony process. SURGICAL TECHNIQUE LCP system provides angular stable fixation. POSTOPERATIVE MANAGEMENT Without concomitant surgical procedures of soft tissue (e.g., patellar tendon shortening), early functional rehabilitation is possible with immediate weight bearing (35 kg for small fragment plates and 70 kg for large fragment plates). RESULTS The surgical procedure is safe and is associated with few complications. Overall complication rate in this series of patients was 3%.
Resumo:
PURPOSE To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction. METHOD Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. Plates were fixed with six screws according a preparation protocol. Four point bending tests were then performed using artificial bone material to compare their initial stability and failure limit under realistic loading conditions. Loading of the plates was performed using of a servo hydraulic driven testing machine. The stiffness of the implant/bone construct was calculated using a linear regression on the experimental data included in a range of applied moment between 2 Nm and 6 Nm. RESULTS No statistical difference in the elastic stiffness was visible between the three types of plate. However, differences were observed between the systems concerning the maximal load supported. The Stryker and Synthes systems were able to support a significantly higher moment. CONCLUSION For clinical application all systems show good and reliable results. Practical aspects such as handling, possible angulation of screw fixation, possibility of screw/plate removal, etc. may favour one or the other plating system.
Resumo:
Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.