941 resultados para Calibrador de dose


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contribution of the total dose due to deposition of secondary energy particles caused by nuclear inelastic processes (n, 2H, 3H, 3He and  ) in proton therapy is an opened problem and in discussion. In the calculations of plans implemented for routine treatment, the paid dose is calculated whereas that the proton loses energy by ionization and or coulomb excitement. The contribution of inelastic processes associated with nuclear reactions is not considered, mainly due to the difficulty of processing targets consisting of various materials. In this sense, there are only estimates for pure materials or simple composition (water, for example).This work presents the results of simulations by the Monte Carlo method employing the code MCNPX v2.50 (Monte Carlo N-Particle eXtended) of the contribution to the total dose of secondary particles. The study was implemented in a cylindrical phantom composed by compact bone, for monochromatic beams of protons between 100 and 200 MeV with pencil beam form

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A inflamação é basicamente uma resposta de proteção tissular cuja função é proteger o organismo de micro-organismos e toxinas que promovem a lesão celular. A resposta inflamatória gera o aparecimento dos quatro sinais cardinais dor, edema, calor e rubor podendo posteriormente ocorrer a perda de função do tecido ou órgão. Os anti-inflamatórios não esteroides (AINEs) promovem sua atividade alterando a atividade de prostaglandinas (PGs), por inibição das isoformas de ciclo-oxigenases constitutivas (COX1) e induzidas (COX2). A inibição não seletiva destas enzimas (por AINEs clássicos) gera reações adversas graves, como as reações gastrointestinais, em pacientes pré-dispostos e/ou que as utilizam por um período prolongado. Os AINEs de segunda geração (inibidores seletivos de COX2), também se mostraram tóxicos, podendo causar alterações cardiovasculares. Neste sentido, o planejamento de novos compostos com atividade anti-inflamatória e destituídos de toxicidade ainda é um desafio para a química farmacêutica e medicinal. Dois derivados de ibuprofeno (AINE clássico) foram obtidos anteriormente no Lapdesf por Castro (2008) e Vizioli (2006), demonstrando atividade anti-inflamatória em modelo de inflamação aguda (edema de pata) e crônica (colite ulcerativa), destituídos de gastroulceração (VIZIOLI, 2009). Diante destes resultados o presente estudo visou à preparação dos compostos e o estudo pré-clínico de toxicidade em dose única (aguda) e em doses repetidas em camundongos, bem como as análises comportamentais, histopatológicas dos órgãos e ensaios bioquímicos. Os achados comportamentais, bioquímicos e histopatológicos permitem concluir que não foi observada toxicidade nos modelos estudados, exceto para o grupo de administração dose única de 2000 mg/kg via intraperitoneal do composto Lapdesf ibu-tau.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This report highlights phytoconstituents present in Cissus quadrangularis (CQ) extract and examines biphasic (proliferative and anti-proliferative) effects of its extract on bone cell proliferation, differentiation, mineralization, ROS generation, cell cycle progression and Runx2 gene expression in primary rat osteoblasts. Materials and methods: Phytoconstituents were identified using gas chromatography-mass spectroscopy (GC-MS). Osteoblasts were exposed to different concentrations (10-100g/ml) of CQ extract and cell proliferation and cell differentiation were investigated at different periods of time. Subsequently, intracellular ROS intensity, apoptosis and matrix mineralization of osteoblasts were evaluated. We performed flow cytometry for DNA content and real-time PCR for Runx2 gene expression analysis.Results: CQ extract's approximately 40 bioactive compounds of fatty acids, hydrocarbons, vitamins and steroidal derivatives were identified. Osteoblasts exposed to varying concentrations of extract exhibited biphasic variation in cell proliferation and differentiation as a function of dose and time. Moreover, lower concentrations (10-50g/ml) of extract slightly reduced ROS intensity, although they enhanced matrix mineralization, DNA content in S phase of the cell cycle, and levels of Runx2 expression. However, higher concentrations (75-100g/ml) considerably induced the ROS intensity and nuclear condensation in osteoblasts, while it reduced mineralization level, proportion of cells in S phase and Runx2 level of the osteogenic gene.Conclusions: These findings suggest that CQ extract revealed concentration-dependent biphasic effects, which would contribute notably to future assessment of pre-clinical efficacy and safety studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Benzodiazepines are one of the most frequently prescribed drugs due to their anxiolytic properties. The aim of this study was to evaluate the effects of diazepam on lipopolysaccharide-induced peritoneal acute inflammatory responses. Swiss mice were treated with diazepam in a single dose of 1 or 10 mg/kg- subcutaneously 1 h before an intraperitoneal injection of lipopolysaccharide or sterile saline solution. The mice were killed 16 h after and the cells were washed from the peritoneal cavity to determine the total number of cells and the mononuclear and polimorfonuclear subpopulations, as well as the TNF-alpha activity and percentage of spread macrophages. Our results showed that the diazepam treatment (1 and 10 mg/kg) induced a significant reduction in the LPS-induced macrophage stimulation and TNF-α activity. Diazepam (10 mg/kg) also reduced the inflammatory cellular migration when compared to the control. It can be concluded that the diazepam treatment in a single dose is able to influence the inflammatory cellular influx, macrophage stimulation and TNF-α activity in the acute inflammatory response in mice, having possible implications on the anti-infectious response efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was conducted to examine the luteolytic effectiveness of using low or micro doses of PGF2α when administered at the BAI HUI acupuncture point, which is frequently used to treat ovarian disturbances in veterinary acupuncture. The results indicate that PGF2α given at a very low micro dose of 0.5 mg (one tenth the conventional recommended dose) administered at the BAI HUI acupuncture point located at the sacral lumbar space is equally effective at inducing luteolysis in mid-luteal phase mares as conventional PGF2α i.m. treatment using a tenfold higher dose. Therefore, based on the results of the present study, we suggest that the BAI HUI sacrai lumbar route somehow provides an extremely efficient pathway for the drug to the ovarian level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to optimize a radiographic technique for hand examinations using a computed radiography (CR) system and demonstrate the potential for dose reductions compared with clinically established technique. An exposure index was generated from the optimized technique to guide operators when imaging hands. Homogeneous and anthropomorphic phantoms that simulated a patient's hand were imaged using a CR system at various tube voltages and current settings (40-55 kVp, 1.25-2.8 mAs), including those used in clinical routines (50 kVp, 2.0 mAs) to obtain an optimized chart. The homogeneous phantom was used to assess objective parameters that are associated with image quality, including the signal difference-to-noise ratio (SdNR), which is used to define a figure of merit (FOM) in the optimization process. The anthropomorphic phantom was used to subjectively evaluate image quality using Visual Grading Analysis (VGA) that was performed by three experienced radiologists. The technique that had the best VGA score and highest FOM was considered the gold standard (GS) in the present study. Image quality, dose and the exposure index that are currently used in the clinical routine for hand examinations in our institution were compared with the GS technique. The effective dose reduction was 67.0%. Good image quality was obtained for both techniques, although the exposure indices were 1.60 and 2.39 for the GS and clinical routine, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The request of three-dimensional images (3D) of the dentomaxillofacial complex has increased. Hence, new possibilities for assessment, treatment as well as follow-up after treatment have increased their importance with the use of cone beam computed tomography (CBCT). The images in two dimensions (2D) have inherent problems that can be solved with treedimensional images assessment. Objectives: To clarify the main doubts about the operational mechanism of complementary diagnostic method; to explain the advantages and disadvantages, to discuss the effective radiation dose and possible applications in orthodontia. Conclusion: The information generated by 2D images from the CBCT does not show differences that may endanger the orthodontic planning when compared with the images of 2D conventional radiographs. The effective radiation dose received by the patient should not be considered as a limiting factor of the tomography exam request.