913 resultados para Câmaras DSLR


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The SPECT (Single Photon Emission Computed Tomography) systems are part of a medical image acquisition technology which has been outstanding, because the resultant images are functional images complementary to those that give anatomic information, such as X-Ray CT, presenting a high diagnostic value. These equipments acquire, in a non-invasive way, images from the interior of the human body through tomographic mapping of radioactive material administered to the patient. The SPECT systems are based on the Gamma Camera detection system, and one of them being set on a rotational gantry is enough to obtain the necessary data for a tomographic image. The images obtained from the SPECT system consist in a group of flat images that describe the radioactive distribution on the patient. The trans-axial cuts are obtained from the tomographic reconstruction techniques. There are analytic and iterative methods to obtain the tomographic reconstruction. The analytic methods are based on the Fourier Cut Theorem (FCT), while the iterative methods search for numeric solutions to solve the equations from the projections. Within the analytic methods, the filtered backprojection (FBP) method maybe is the simplest of all the tomographic reconstruction techniques. This paper's goal is to present the operation of the SPECT system, the Gamma Camera detection system, some tomographic reconstruction techniques and the requisites for the implementation of this system in a Nuclear Medicine service

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A exposição experimental a vapores de solventes pela via respiratória pode ser realizada em câmaras de dois tipos: a que expõe todo o animal por imersão na atmosfera experimental e aquela em que a exposição se dá apenas pelo nariz. O sistema para exposição apenas pelo nariz, denominado de NOES- Nose Only Exposure System, tem as vantagens de utilizar menos material, ter uma atmosfera continuamente renovada, produzir exposição mais uniforme entre os animais, ser mais facilmente controlado e evitar a penetração dos solventes por outras vias. A desvantagem está no fato na restrição do tempo do experimento por provocar estresse ao animal. O projeto experimental consistiu na validação de uma câmara de exposição para ratos, do tipo NOES, dotada de 44 portas, através da avaliação da homogeneidade e da estabilidade das concentrações de voláteis na atmosfera a ser inalada, utilizando etanol combustível como agente químico para os testes. Os resultados indicaram que a variabilidade das concentrações entre os planos da câmara (portas da camada superior e inferior), entre portas de exposição e, também, entre as médias apuradas para cada tempo não diferem expressivamente entre si. Assim, pode-se considerar que o equipamento mostrou-se adequado para manter a homogeneidade e a estabilidade das concentrações durante as 6 horas de experimentação, para o etanol combustível

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, it was studied the thermal and fluid dynamic behavior from theorical and experimental point of view of a blast furnace tuyere. The tuyere is responsible for the hot air insuflation into the blast furnace. The parameter used in the comparison was the difference between the cooling water inlet and outlet temperatures. There were used forced convection correlations inside circular sections with adequations for non circular sections. Based on operations dates of flux and thermal loads it was possible to model numerically the tuyere, and, since it was obtained the wall temperatures, estimate the conduction and convection resistances and the heat flux through the walls in contact with the water. The total heat fluxes from wall to water were applied to the energy conservation equation where could be estimated the theorical temperature variation. Compared to the real value, the theorical value presented a difference of 0,2 °C. Considering that the boundary conditions around the tuyere are transitories and that your channels have some rugosity irregularities we can consider the estimation method for cooling system coherent with the real operational parameters

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diante do fato da existência de inúmeros diásporos preservados em exsicatas nos herbários e da necessidade de se desenvolverem novas práticas conservacionistas esta pesquisa buscou avaliar a capacidade de um herbário de atuar como banco de germoplasma complemetar através da propagação de espécies vegetais pela germinação sementes retiradas de exsicatas. O estudo teve como foco espécies típicas do cerrado lato sensu, pois estas tiveram uma trajetória evolutiva com pressões de queimadas naturais, o que provavelmente proporciona às sementes destas espécies maior resistência à dessecassão provocada pelo processo de herborização. Foram utilizados apenas propágulos que apresentavam maturação completa no momento de coleta. Estes provieram de duplicatas do herbário ESA (sediado na ESALQ - USP – Piracicaba). Os testes de germinação foram realizados em substrato de vermiculita fina peneirada, previamente esterelizada, e conduzidos em câmaras de germinação tipo B.O.D. (Biochemical Oxygen Demand) sob fotoperíodo por 24 horas e temperatura constante de 25°C. Estes foram mantido e avaliados 3 vezes por semana durante 60 dias. A pesquisa abrangeu 80 espécies, 25 famílias e um total de 1346 sementes. O N amostral de cada espécie variou de 1 a 30, dependendo da disponibilidade do material. Não foram realizados métodos de quebra de dormência, mas mesmo assim praticamente todas as sementes apresentaram embebissão, com excessão de 8 sementes de Stryphnodendron adstringens. Sementes de cinco espécies germinaram, o que representa que representam 6,25% (N=80) do total de espécies. Elas petencem à duas famílias: Cochlospermum regium e Cochlospermum vitifolium da família Bixaceae e Bowdichia virgiloides, Hymenaea stigonocarpa e Stryphnodendron adstringens da família Fabaceae. A germinação ocorreu entre 10 e 30 dias após a montagem dos testes... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sources of betatherapy for clinical use in Brazil are, the vast majority of strontium-90, radioactive element that is not produced in the country, and therefore requires importation of international laboratories accredited by the International Atomic Energy Agency (IAEA).The use of these resources is always limited the crediting of characteristic values supplied by the manufacturer tables that provide the nominal value of activity and dose distribution to determine the irradiation time of the injury. The Institute of Nuclear Energy Research (IPEN / CNEN-SP) has recently researching the emission profile of these types of radiation sources, and some jobs are being developed with ionization chambers extrapolation for the purpose of standardizing a systematic calibration sources betatherapy. Other studies using parallel measures dosimeters (TLD's) and simulations with the Monte Carlo method. Radiological films have also been used in studies of applicators dosimetric analysis of strontium-90. This paper seeks to analyze the different methods for calibration of applicators betatherapy, already consolidated in studies by examining the advantages and disadvantages of each procedure

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the trans-enamel and transdentinal cytotoxic effects of two in-office tooth bleaching techniques that employ bleaching gels containing 20% and 38% of H2 O2 on cultured odontoblast-like cell line (MDPC-23). Sixty enamel/dentin discs were obtained from bovine central incisors and placed individually in artificial pulp chambers. Six groups were formed according to the following enamel treatments: G1- 20% H2 O2 (1 application); G2- 20% H2 O2 (2 applications); G3- 38% H2 O2 (1 application); G4- 38% H2 O2 (2 applications); G5- 38% H2 O2 (3 applications); and G6- control (no treatment). In G1 and G2, the bleaching gel was left in contact with the enamel surface for 45 min in each application. However, in G3, G4, and G5 the bleaching gel was applied for only 10 min per application. After the last application, the extracts were collected and applied on previously cultured cells (30.000 cells/cm2 ) for 24 h. Cell metabolism was evaluated by the MTT assay and cell morphology was analysed by scanning electron microscopy. Cell metabolism decreased by 96.29%; 96.11%; 96.42%; 95.62%; and 97.18% in G1, G2, G3, G4, and G5, respectively. All treated groups differed significantly from non-treated control group (G6) (p < 0.05). However, the difference in cell metabolism among treated groups was not significant statistically. In addition, significant morphological cell alterations were observed in all treated groups. Under the tested experimental conditions, the extracts collected after both tooth bleaching techniques evaluated in this study caused severe toxic effects on cultured odontoblast-like cell MDPC-23.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Color is an important variable in cosmetic dentistry, and it has traditionally been measured by a visual method, comparing teeth with standard color guides. In recent decades, electronic instruments have been developed to eliminate the subjective factor of visual measurement. This objective method has mainly been performed with colorimeters, spectrophotometers and the analysis of images obtained with digital cameras. These instruments have proven to be reliable with a high degree of precision and accuracy. Its use is recommended as an adjunctive tool to assess color in direct and indirect restorations, in aesthetic treatments like bleaching, and to facilitate communication with the dental laboratory. The spectrophotometer is the device that has reported better “in- vitro “ and “in -vivo” performance, being the “Vita Easyshade “ the one with more reliable results.