952 resultados para BOOST converter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the detailed dynamic digital simulation for the study of phenomenon of torsional interaction between HVDC-Turbine generator shaft, dynamics using the novel converter model presented in [ 1 ] The system model includes detailed representation of the synchronous generator and the shaft dynamics, the ac and dc network transients. The results of a case study indicate the various factors that influence the torsional interaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Static characteristics of an analog-to-digital converter (ADC) can be directly determined from the histogram-based quasi-static approach by measuring the ADC output when excited by an ideal ramp/triangular signal of sufficiently low frequency. This approach requires only a fraction of time compared to the conventional dc voltage test, is straightforward, is easy to implement, and, in principle, is an accepted method as per the revised IEEE 1057. However, the only drawback is that ramp signal sources are not ideal. Thus, the nonlinearity present in the ramp signal gets superimposed on the measured ADC characteristics, which renders them, as such, unusable. In recent years, some solutions have been proposed to alleviate this problem by devising means to eliminate the contribution of signal source nonlinearity. Alternatively, a straightforward step would be to get rid of the ramp signal nonlinearity before it is applied to the ADC. Driven by this logic, this paper describes a simple method about using a nonlinear ramp signal, but yet causing little influence on the measured ADC static characteristics. Such a thing is possible because even in a nonideal ramp, there exist regions or segments that are nearly linear. Therefore, the task, essentially, is to identify these near-linear regions in a given source and employ them to test the ADC, with a suitable amplitude to match the ADC full-scale voltage range. Implementation of this method reveals that a significant reduction in the influence of source nonlinearity can be achieved. Simulation and experimental results on 8- and 10-bit ADCs are presented to demonstrate its applicability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multilevel converters have been under research and development for more than three decades and have found successful industrial application. However, this is still a technology under development, and many new contributions and new commercial topologies have been reported in the last few years. The aim of this paper is to group and review these recent contributions, in order to establish the current state of the art and trends of the technology, to provide readers with a comprehensive and insightful review of where multilevel converter technology stands and is heading. This paper first presents a brief overview of well-established multilevel converters strongly oriented to their current state in industrial applications to then center the discussion on the new converters that have made their way into the industry. In addition, new promising topologies are discussed. Recent advances made in modulation and control of multilevel converters are also addressed. A great part of this paper is devoted to show nontraditional applications powered by multilevel converters and how multilevel converters are becoming an enabling technology in many industrial sectors. Finally, some future trends and challenges in the further development of this technology are discussed to motivate future contributions that address open problems and explore new possibilities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The optimization of a photovoltaic pumping system based on an induction motor driven pump that is powered by a solar array is presented in this paper. The motor-pump subsystem is analyzed from the point of view of optimizing the power requirement of the induction motor, which has led to an optimum u-f relationship useful in controlling the motor. The complete pumping system is implemented using a dc-dc converter, a three-phase inverter, and an induction motor-pump set. The dc-dc converter is used as a power conditioner and its duty cycle is controlled so as to match the load to the array. A microprocessor-based controller is used to carry out the load-matching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In receive antenna selection (AS), only signals from a subset of the antennas are processed at any time by the limited number of radio frequency (RF) chains available at the receiver. Hence, the transmitter needs to send pilots multiple times to enable the receiver to estimate the channel state of all the antennas and select the best subset. Conventionally, the sensitivity of coherent reception to channel estimation errors has been tackled by boosting the energy allocated to all pilots to ensure accurate channel estimates for all antennas. Energy for pilots received by unselected antennas is mostly wasted, especially since the selection process is robust to estimation errors. In this paper, we propose a novel training method uniquely tailored for AS that transmits one extra pilot symbol that generates accurate channel estimates for the antenna subset that actually receives data. Consequently, the transmitter can selectively boost the energy allocated to the extra pilot. We derive closed-form expressions for the proposed scheme's symbol error probability for MPSK and MQAM, and optimize the energy allocated to pilot and data symbols. Through an insightful asymptotic analysis, we show that the optimal solution achieves full diversity and is better than the conventional method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A two-channel boxcar integrator with an analog to digital converter was constructed using integrated circuits wherever convenient. The digital output can be instantaneously displayed or displayed after accumulating many samplings in the totaliser. The totaliser mode provides averaging at the digitiser level and hence the integrator has an infinite holding time. When used in the double boxcar mode the instrument overcomes the problem of any base line instability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grid connected PWM-VSIs are being increasingly used for applications such as Distributed Generation (DG), power quality, UPS etc. Appropriate control strategies for grid synchronisation and line current regulation are required to establish such a grid interconnection and power transfer. Control of three phase VSIs is widely reported in iterature. Conventionally, dq control in Synchronous Reference Frame(SRF) is employed for both PLL and line current control where PI-controllers are used to track the DC references. Single phase systems do not have defined direct (d) and quadrature (q) axis components that are required for SRF transformation. Thus, references are AC in nature and hence usage of PI controllers cannot yield zero steady state errors. Resonant controllers have the ability to track AC references accurately. In this work, a resonant controller based single phase PLL and current control technique are being employed for tracking grid frequency and the AC current reference respectively. A single phase full bridge converter is being operated as a STATCOM for performance evaluation of the control scheme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Direct stability analysis ofAC/DC power systems using a structure-preserving energy function (SPEF) is proposed in this paper. The system model considered retains the load buses thereby enabling the representation of nonlinear voltage dependent loads. TheHVDC system is represented with the same degree of detail as is normally done in transient stability simulation. The converter controllers can be represented by simplified or detailed models. Two or multi-terminalDC systems can be considered. The stability analysis is illustrated with a 3-machine system example and encouraging results have been obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neutral point clamped (NPC), three level converters with insulated gate bipolar transistor devices are very popular in medium voltage, high power applications. DC bus short circuit protection is usually done, using the sensed voltage across collector and emitter (i.e., V-CE sensing), of all the devices in a leg. This feature is accommodated with the conventional gate drive circuits used in the two level converters. The similar gate drive circuit, when adopted for NPC three level converter protection, leads to false V-CE fault signals for inner devices of the leg. The paper explains the detailed circuit behavior and reasons, which result in the occurrence of such false V-CE fault signals. This paper also illustrates that such a phenomenon shows dependence on the power factor of the supplied three-phase load. Finally, experimental results are presented to support the analysis. It is shown that the problem can be avoided by blocking out the V-CE sense fault signals of the inner devices of the leg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is possible to sample signals at sub-Nyquist rate and still be able to reconstruct them with reasonable accuracy provided they exhibit local Fourier sparsity. Underdetermined systems of equations, which arise out of undersampling, have been solved to yield sparse solutions using compressed sensing algorithms. In this paper, we propose a framework for real time sampling of multiple analog channels with a single A/D converter achieving higher effective sampling rate. Signal reconstruction from noisy measurements on two different synthetic signals has been presented. A scheme of implementing the algorithm in hardware has also been suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the analysis and study of voltage collapse at any converter bus in A C-DC systems considering the dynamics of DC system. The problem of voltage instability is acute when HVDC links are connected to weak AC systems, the strength determined by short circuit ratio (SCR) at the converter bus. The converter control strategies are important in determining voltage instability. Small signal analysis is used to identify critical modes and evaluate the effect of AC system strength and control parameters. A sample two-terminal DC system is studied and the results compared with those obtained from static analysis. Also, the results obtained from small signal analysis are validated with nonlinear simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new approach to the power flow analysis in steady state for multiterminal DC-AC systems. A flexible and practical choice of per unit system is used to formulate the DC network and converter equations. A converter is represented by Norton's equivalent of a current source in parallel with the commutation resistance. Unlike in previous literature, the DC network equations are used to derive the controller equations for the DC system using a subset of specifications. The specifications considered are current or power at all terminals except the slack terminal where the DC voltage is specified. The control equations are solved by Newton's method, using the current injections at the converter terminals as state variables. Further, a systematic approach to the handling of constraints is proposed by identifying the priorities in rescheduling of the specified variables. The methodology is illustrated by example of a 5 terminal DC system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern PWM inverter output voltage has high dv/dt, which causes problems such as voltage doubling that can lead to insulation failure, ground currents that results in electromagnetic interference concerns. The IGBT switching device used in such inverter are becoming faster, exacerbating these problems. This paper proposes a new procedure for designing the LC clamp filter. The filter increases the rise time of the output voltage of inverter, resulting in smaller dv/dt. In addition suitable selection of resonance frequency gives LCL filter configuration with improved attenuation. By adding this filter at output terminal of inverter which uses long cable, voltage doubling effect is reduced at the motor terminal. The design procedure is carried out in terms of the power converter based per unit scheme. This generalizes the design procedure to a wide range of power level and to study optimum designs. The effectiveness of the design is verified by computer simulation and experimental measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the possibility of cavitation in the non-conformal N = 2* SU(N) theory which is a mass deformation of N = 4 SU(N) Yang-Mills theory. The second order transport coefficients are known from the numerical work using AdS/CFT by Buchel and collaborators. Using these and the approach of Rajagopal and Tripuraneni, we investigate the flow equations in a (1 + 1)-dimensional boost invariant set up. We find that the string theory model does not exhibit cavitation before phase transition is reached. We give a semi-analytic explanation of this finding. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The soft switching converters evolved through the resonant load, resonant switch, resonant transition and active clamp converters to eliminate switching losses in power converters. This paper briefly presents the operating principle of the new family of soft transition converters; the methodology of design of these converters is presented through an example. In the proposed family of converters, the switching transitions of both the main switch and auxiliary switch are lossless.When these converters are analysed in terms of the pole current and throw voltage, the defining equations of all converters belonging to this family become identical.Such a description allows one to define simple circuit oriented model for these converters. These circuit models help in evaluating the steady state and dynamic model of these converters. The standard dynamic performance functions of the converters are readily obtainable from this model. This paper presents these dynamic models and verifies the same through measurements on a prototype converter.