991 resultados para 6-OH-chlorzoxazone


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CYP2D6 is the key enzyme responsible for tamoxifen bioactivation mainly into endoxifen. This gene is highly polymorphic and breast cancer patients classified as CYP2D6 poor metabolizers (PM) or intermediate metabolizers (IM) appear to show low concentrations of endoxifen and to achieve less benefit from tamoxifen treatment. Purpose: This prospective, open-label trial aimed to assess how the increase of tamoxifen dose influences the level of endoxifen in the different genotype groups (poor-, intermediate-, and extensive-metabolizers (EM)). We examined the impact of doubling tamoxifen dose to 20mg twice daily on endoxifen plasma concentrations across these genotype groups. Patients and methods: Patients were assayed for CYP2D6 genotype and phenotype using dextromethorphan test. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma levels were determined on 2 occasions at baseline (20mg/day of tamoxifen) and at day 30, 90 and 120 after dose increase (20 mg twice daily) using liquid chromatography-tandem-mass spectrometry. Endoxifen plasma levels were measured 6 to 24 hours after last drug intake to evaluate its accumulation before and after doubling tamoxifen dosage. ANOVA was used to evaluate endoxifen levels increase and difference between genotype groups. Results: 63 patients are available for analysis to date. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma reached steady state at 30 day after tamoxifen dose escalation, with a significant increase compared to baseline by 1.6 to 1.8 fold : geometric mean plasma concentrations (CV %) were 140 ng/mL (45%) at baseline vs 255 (47%) at day 30 for tamoxifen (P < 0.0001); 256 (49%) vs 408 (64%) for N-desmethyltamoxifen (P < 0.0001); 2.4 (46%) vs 3.9 (51%) for 4-OH-tamoxifen (P < 0.0001); and 20 (91%) vs 33 (91%) for endoxifen (P < 0.02). On baseline, endoxifen levels tended to be lower in PM: 7 ng/mL (36%), than IM: 16 ng/mL (70%), P=0.08, and EM: 24 ng/mL (71%), P<0.001. After doubling tamoxifen dosage, endoxifen concentrations rose similarly in PM, IM and EM with respectively, 1.5 (18%), 1.5 (28%) and 1.7 (30%) fold increase from baseline, P=0.18. Conclusion: Endoxifen exposure varies widely under standard tamoxifen dosage, with CYP2D6 genotype explaining only a minor part of this variability. It increases consistently on doubling tamoxifen dose, similarly across genotypes. This would enable exposure optimization based on concentration monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The use of remote follow-up (RF) of people with pacemakers (PM) is limited in comparison to the hospital modality (HS), being still poor the scientific evidence that shows their comparative effectiveness. The aim of this study was to compare the quality of life in individuals with different modalities of follow-up. METHODS Controlled, not randomized nor masked clinical trial, with data collection at pre and post-implantation of pacemakers during the 6 months follow-up. All patients over 18 years-old who were implanted a PM during the study period were selected (n = 83), and they were assigned to RF (n = 30) or HF (n = 53) groups according to their personal characteristics and patient's preferences. Baseline characteristics and number of visits to the hospital were analysed, the EuroQol-5D (EQ5D) questionnaire was administered to evaluate the health-related quality of life, and Duke Activity Status Index (DASI) to assess the functional capacity. RESULTS There were no significant differences between both groups in relation to the baseline analysis, EQ5D (RF:0.7299; HF:0.6769) and DASI (RF:21.41; HF:19.99). At 6 months the quality of life was improved in both groups (EQ5D RF:0.8613; HF:0.8175; p = 0,439) still without significant differences between them. DASI score was similar to baseline (20.51 vs 21.80). RF group performed less transmissions/visits per patient (1.57) than hospital group (1.96; relative reduction 31%; p = 0.015). CONCLUSIONS Remote follow-up of people with pacemakers might be considered as an equivalent option to the hospital follow-up in relation to the quality of life and it reduces the number of hospital visits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: C iclosporine ( CsA), Tacrolimus (Tcl) and Infliximab (IFX) are effective rescue therapies in steroidrefractory ulcerative colitis (UC). Comparative studies are however m issing. M ETHOD: T his i s the retrospective analysis of treatment outcome for oral Tcl (n=27, initially 0.05mg/Kg twice daily, aiming for serum trough levels of 5-10 n g/mL), i ntravenous C sA ( n=23, 2 mg/kg/daily a nd then o ral CsA 5mg/kg/daily) and IFX ( n=43, 5 mg/kg intravenously at week 0, 2, 6 and then every 8 weeks) in patients with s teroid r efractory moderate to s evere UC enrolled i n the SWISS IBD cohort s tudy. After successful rescue therapy with Tcl o r C sA, t hiopurine m aintenance therapy or maintenance therapy with Tcl (in Tcl pretreated patients) was introduced. The endpoints analyzed steroid free r emission r ate (on the basis of m odified Truelove- Witts severity index (MTWSI)) and number of colectomies after 6 m onths. R ESULTS: A t 6 months, 26% ( 7/27) o f patients treated with T cl r emained i n steroid free remission (MTWSI score ≤4) compared to 30 % (7/23) on 18 droplets to the same extend under the linoleic acid treat, whereas lipid hydrolysis or loss was significantly increased in Huh-7 WT cells after 24h. Conclusions: Chronic alcohol feeding in obese, insulin-resistant rats exerts significant and synergistic effects on PNPLA3 mRNA expression, which correlated with triglyceride content. In v itro experiments suggest that PNPLA3 expression depends on the t ypes of d ietary f atty acids with polyunsaturated fatty a cids i nducing a nd monounsaturated fatty a cids inhibiting PNPLA3 mRNA. I148M polymorphism of PNPLA3 l eads to attenuation o f lipolytic processes resulting in fat accumulation in the cell. 20 CsA and 58% ( 27/41) o f patients t reated w ith IFX ( Tcl & CsA vs I FX p = 0 .018). S ignificant m ore patients had primary non response, loss of response or severe adverse events i n the CsA cohort ( 61%, 1 4/23) c ompared to Tcl cohort (33.3 % , 9/27), and IFX cohort (30%, 1 3/43) (p= 0.037). Colectomy rate was significantly higher after CsA (17.4 %, 4/23) compared to Tcl (3.7 %, 1/27) or IFX (2.3 %, 1/43) (p= 0.047).CONCLUSION: After s ix m onth, rescue therapy with I FX h ad t he l owest c olectomy r ate, significantly h igher steroid free r emission rate, a nd t he lowest rate of non-response, loss of response and severe adverse events compared to CsA or Tcl rescue treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With advances in the effectiveness of treatment and disease management, the contribution of chronic comorbid diseases (comorbidities) found within the Charlson comorbidity index to mortality is likely to have changed since development of the index in 1984. The authors reevaluated the Charlson index and reassigned weights to each condition by identifying and following patients to observe mortality within 1 year after hospital discharge. They applied the updated index and weights to hospital discharge data from 6 countries and tested for their ability to predict in-hospital mortality. Compared with the original Charlson weights, weights generated from the Calgary, Alberta, Canada, data (2004) were 0 for 5 comorbidities, decreased for 3 comorbidities, increased for 4 comorbidities, and did not change for 5 comorbidities. The C statistics for discriminating in-hospital mortality between the new score generated from the 12 comorbidities and the Charlson score were 0.825 (new) and 0.808 (old), respectively, in Australian data (2008), 0.828 and 0.825 in Canadian data (2008), 0.878 and 0.882 in French data (2004), 0.727 and 0.723 in Japanese data (2008), 0.831 and 0.836 in New Zealand data (2008), and 0.869 and 0.876 in Swiss data (2008). The updated index of 12 comorbidities showed good-to-excellent discrimination in predicting in-hospital mortality in data from 6 countries and may be more appropriate for use with more recent administrative data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’objecte d’aquest projecte és fer l’automatitazció d’una piscina de natació contínua contracorrent de 6 carrils. L’automatització haurà de controlar en tot moment l’estat de l’aigua de la piscina per mantenir-la en bones condicions. Això es durà a terme mitjançant el citcuit de recircuació i el circuit de dosificació. A part de tasques de mantenimen, l’automatització hautà de permètre que mitjançant unes pantalles tàctils els usuaris puguin controlar el corrent que surt per la bomba contracorrent i puguin crear els seus propis programes d’entrenamnent. La piscina serà d’obra, d’unes dimensions 15,4x4x2 que emplenarem d’aigua dolça calenta i la tractarem amb clor. Per poder mantenir la piscina i la seva aigua en bones condicions haurem de controlar certs paràmetres com el clor, el pH i la temperatura

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A utilização de microcomputadores tem se tornado imprescindível atualmente e o pessoal de enfermagem, de encontro a esse avanço tecnológico vem incorporando o em sua prática, a qual é iniciada no curso de graduação. Como usuários da seção de informática de uma escola de enfermagem passamos a observar queixas de alunos em relação a adequação dos mobiliários utilizados. Interessou-nos então, desenvolver este estudo que teve por objetivo analisar os mobiliários da, sala de informática com vistas às recomendações ergonômicas e identificar as posturas corporais adotadas pelos alunos na realização da atividade de digitação. Os procedimentos utilizados foram executados em 3 fases, observação livre do ambiente físico e mensuração dos mobiliários, observação das posturas corporais e entrevistas. Os resultados apontaram que o mobiliário utilizado é inadequado no que se refere a: bancada fixa, sem apoio para os pés, sem porta documentos; as cadeiras não são reguláveis, tem largura, do encosto fora dos padrões recomendados, não possuem braços e rodas, só tem quatro pés e tem, revestimento escorregadio e duro. Apenas em 18,6% do período observado foi adotada a postura considerada ideal para atividade de digitação, ou seja, coluna vertebral ereta,, cotovelos na altura do nível da bancada, pernas fletidas e pés apoiados. Sugere-se o planejamento de postos de trabalho para digitação a partir de dados relativos as medidas antropométricas dos usuários e da utilização de mobiliários adequados, a fim de que se possa oh ter um conjunto harmonioso entre mobiliário, ambiente e usuário proporcionando conforto e evitando problemas de saúde.