982 resultados para 13C corrected


Relevância:

20.00% 20.00%

Publicador:

Resumo:

v. 46, n. 2, p. 140-148, apr./jun. 2016.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hintergrund: Helicobacter pylori (H. pylori) zählt trotz abnehmender Inzidenz zu den häufigsten bakteriellen Infektionskrankheiten des Menschen. Die Infektion mit H. pylori ist ein Risikofaktor für Krankheiten wie gastroduodenale Geschwüre, Magenkarzinomen und MALT (Mucosa Associated Lymphoid Tissue)-Lymphomen. Zur Diagnostik von H. pylori stehen verschiedene invasive und nichtinvasive Verfahren zur Verfügung. Der 13C-Harnstoff-Atemtest wird zur Kontrolle einer Eradikationstherapie empfohlen, kommt in der Primärdiagnostik von H. pylori derzeit jedoch nicht standardmäßig in Deutschland zum Einsatz. Fragestellung: Welchen medizinischen und gesundheitsökonomischen Nutzen hat die Untersuchung auf H. pylori-Besiedlung mittels 13C-Harnstoff-Atemtest in der Primärdiagnostik im Vergleich zu invasiven und nichtinvasiven diagnostischen Verfahren? Methodik: Basierend auf einer systematischen Literaturrecherche in Verbindung mit einer Handsuche werden Studien zur Testgüte und Kosten-Effektivität des 13C-Harnstoff-Atemtests im Vergleich zu anderen diagnostischen Verfahren zum primären Nachweis von H. pylori identifiziert. Es werden nur medizinische Studien eingeschlossen, die den 13C-Harnstoff-Atemtest direkt mit anderen H. pylori-Testverfahren vergleichen. Goldstandard ist eines oder eine Kombination der biopsiebasierten Testverfahren. Für die gesundheitsökonomische Beurteilung werden nur vollständige gesundheitsökonomische Evaluationsstudien einbezogen, bei denen die Kosten-Effektivität des 13C Harnstoff-Atemtests direkt mit anderen H. pylori-Testverfahren verglichen wird. Ergebnisse: Es werden 30 medizinische Studien für den vorliegenden Bericht eingeschlossen. Im Vergleich zum Immunglobulin G (IgG)-Test ist die Sensitivität des 13C-Harnstoff-Atemtests zwölfmal höher, sechsmal niedriger und einmal gleich, und die Spezifität 13-mal höher, dreimal niedriger und zweimal gleich. Im Vergleich zum Stuhl-Antigen-Test ist die Sensitivität des 13C-Harnstoff-Atemtests neunmal höher, dreimal niedriger und einmal gleich, und die Spezifität neunmal höher, zweimal niedriger und zweimal gleich. Im Vergleich zum Urease-Schnelltest sind die Sensitivität des 13C-Harnstoff-Atemtests viermal höher, dreimal niedriger und viermal gleich und die Spezifität fünfmal höher, fünfmal niedriger und einmal gleich. Im Vergleich mit der Histologie ist die Sensitivität des 13C-Harnstoff-Atemtests einmal höher und zweimal niedriger und die Spezifität zweimal höher und einmal niedriger. In je einem Vergleich zeigt sich kein Unterschied zwischen 13C-Harnstoff-Atemtest und 14C-Harnstoff-Atemtest, sowie eine niedrigere Sensitivität und höhere Spezifität im Vergleich zur Polymerase-Kettenreaktion (PCR). Inwieweit die beschriebenen Unterschiede statistisch signifikant sind, wird in sechs der 30 Studien angegeben. Es werden neun gesundheitsökonomische Evaluationen in dem vorliegenden Bericht berücksichtigt. Die Test-and-Treat-Strategie mittels 13C-Harnstoff-Atemtest wird in sechs Studien mit einem Test-and-Treat-Verfahren auf Basis der Serologie sowie in drei Studien mit einem Test-and-Treat-Verfahren auf Basis des Stuhl-Antigen-Tests verglichen. Dabei ist das Atemtestverfahren dreimal kosteneffektiv gegenüber der serologischen Methode und wird von der Stuhl-Antigen-Test-Strategie einmal dominiert. Vier Studien beinhalten einen Vergleich der Test-and -Treat-Strategie auf Basis des 13C-Harnstoff-Atemtests mit einer empirischen antisekretorischen Therapie, wobei sich das Atemtesverfahren zweimal als kosteneffektive Prozedur erweist und zwei Studien einen Vergleich mit einer empirischen Eradikationstherapie. In fünf Studien wird das Test-and-Treat-Verfahren mittels 13C-Harnstoff-Atemtest einer endoskopiebasierten Strategie gegenübergestellt. Zweimal dominiert die Atemteststrategie die endoskopische Prozedur und einmal wird sie von dieser Strategie dominiert. Diskussion:Sowohl die medizinischen als auch die ökonomischen Studien weisen mehr oder minder gravierende Mängel auf und liefern heterogene Ergebnisse. So werden in der Mehrzahl der medizinischen Studien keine Angaben zur statistischen Signifikanz der berichteten Unterschiede zwischen den jeweiligen Testverfahren gemacht. Im direkten Vergleich weist der 13C-Harnstoff-Atemtest überwiegend eine höhere Testgüte als der IgG und der Stuhl-Antigen-Test auf. Aus den Vergleichen mit dem Urease-Schnelltest lassen sich keine Tendenzen bezüglich der Sensitivität ableiten, wohingegen die Spezifität des 13C-Harnstoff-Atemtests höher einzuschätzen ist. Für die Vergleiche des 13C-Harnstoff-Atemtest mit der Histologie, dem 14C-Harnstoff-Atemtest und der PCR liegen zu wenige Ergebnisse vor. In der eingeschlossenen ökonomischen Literatur deuten einige Studienergebnisse auf eine Kosten-Effektivität der Test-and-Treat-Strategie mittels 13C-Harnstoff-Atemtest gegenüber dem Test-and-Treat-Verfahren auf Basis der Serologie und der empirischen antiskretorischen Therapie hin. Um Tendenzen bezüglich der Kosten-Effektivität der Atemteststrategie gegenüber der Test-and-Treat-Strategie mittels Stuhl-Antigen-Test sowie der empirischen Eradikationstherapie abzuleiten, mangelt es an validen Ergebnissen bzw. ökonomischer Evidenz. Die Untersuchungsresultate hinsichtlich eines Vergleichs mit endoskopiebasierten Verfahren fallen diesbezüglich zu heterogen aus. Insgesamt kann keines der ökonomischen Modelle der Komplexität des Managements von Patienten mit dyspeptischen Beschwerden gänzlich gerecht werden. Schlussfolgerungen/Empfehlungen: Zusammenfassend ist festzuhalten, dass die Studienlage zur medizinischen und ökonomischen Beurteilung des 13C-Harnstoff-Atemtests im Vergleich zu anderen diagnostischen Methoden nicht ausreichend ist, um den Atemtest als primärdiagnostisches Standardverfahren im Rahmen einer Test-and-Treat-Strategie beim Management von Patienten mit dyspeptischen Beschwerden für die deutsche Versorgungslandschaft insbesondere vor dem Hintergrund der Leitlinien der Deutschen Gesellschaft für Verdauungs- und Stoffwechselkrankheiten (DGVS) anstelle einer endoskopiebasierten Methode zu empfehlen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este trabajo se presentan datos de la composición isotópica en carbono y oxígeno de rocas carbonáticas (calizas y dolomías) en el sector Reocín-La Florida (Cantabria). Estos materiales constituyen la roca encajante de importantes mineralizaciones dé Zn-Pb (tipo Mississippi Valley) de edad Cretácica. Las calizas analizadas tienen valores medios del ð13C(PDB) y ð18 O(SMOW) de +3,15 y +27,21, respectivamente. y las dolomías de +2,05 y +25,53, respectivamente. Estos datos sugieren una génesis diferente para ambos tipos de carbonatos, de tal forma que un origen singenético para las mineralizaciones debe ser rechazado. También se analizan otros tipos de carbonatos presentes (calizas de dolomitización y espeleotemas), cuyos datos indican un origen relacionado con aguas meteóricas, dado el empobrecimiento que estos materiales poseen en los isótopos pesados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-range non-covalent interactions play a key role in the chemistry of natural polyphenols. We have previously proposed a description of supramolecular polyphenol complexes by the B3P86 density functional coupled with some corrections for dispersion. We couple here the B3P86 functional with the D3 correction for dispersion, assessing systematically the accuracy of the new B3P86-D3 model using for that the well-known S66, HB23, NCCE31, and S12L datasets for non-covalent interactions. Furthermore, the association energies of these complexes were carefully compared to those obtained by other dispersion-corrected functionals, such as B(3)LYP-D3, BP86-D3 or B3P86-NL. Finally, this set of models were also applied to a database composed of seven non-covalent polyphenol complexes of the most interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report discusses the calculation of analytic second-order bias techniques for the maximum likelihood estimates (for short, MLEs) of the unknown parameters of the distribution in quality and reliability analysis. It is well-known that the MLEs are widely used to estimate the unknown parameters of the probability distributions due to their various desirable properties; for example, the MLEs are asymptotically unbiased, consistent, and asymptotically normal. However, many of these properties depend on an extremely large sample sizes. Those properties, such as unbiasedness, may not be valid for small or even moderate sample sizes, which are more practical in real data applications. Therefore, some bias-corrected techniques for the MLEs are desired in practice, especially when the sample size is small. Two commonly used popular techniques to reduce the bias of the MLEs, are ‘preventive’ and ‘corrective’ approaches. They both can reduce the bias of the MLEs to order O(n−2), whereas the ‘preventive’ approach does not have an explicit closed form expression. Consequently, we mainly focus on the ‘corrective’ approach in this report. To illustrate the importance of the bias-correction in practice, we apply the bias-corrected method to two popular lifetime distributions: the inverse Lindley distribution and the weighted Lindley distribution. Numerical studies based on the two distributions show that the considered bias-corrected technique is highly recommended over other commonly used estimators without bias-correction. Therefore, special attention should be paid when we estimate the unknown parameters of the probability distributions under the scenario in which the sample size is small or moderate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new Expiratory Droplet Investigation System (EDIS) was used to conduct the most comprehensive program of study to date, of the dilution corrected droplet size distributions produced during different respiratory activities.----- Distinct physiological processes were responsible for specific size distribution modes. The majority of particles for all activities were produced in one or more modes, with diameters below 0.8 µm. That mode occurred during all respiratory activities, including normal breathing. A second mode at 1.8 µm was produced during all activities, but at lower concentrations.----- Speech produced particles in modes near 3.5 µm and 5 µm. The modes became most pronounced during continuous vocalization, suggesting that the aerosolization of secretions lubricating the vocal chords is a major source of droplets in terms of number.----- Non-eqilibrium droplet evaporation was not detectable for particles between 0.5 and 20 μm implying that evaporation to the equilibrium droplet size occurred within 0.8 s.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For a number of years now it has been evident that the major issue facing science educators in the more developed countries of the world is the quantitative decline in enrolments in the senior secondary sciences, particularly the physical sciences, and in the number of higher achieving students applying for places in universities to undertake further studies in science. The deep malaise in school science to which these quantitative measures point has been elucidated by more qualitative studies of the students’ experience of studying science in secondary school in several of these countries (Sweden, Lindahl (2003); England, Simon and Osborne (2002); and Australia, Lyons (2005)). Remarkably concordant descriptions of these experiences can be summarized as: School science is: • transmission of knowledge from the teacher or the textbook to the students. • about content that is irrelevant and boring to our lives. • difficult to learn in comparison with other subjects Incidentally, the Australian study only involved consistently high achieving students; but even so, most of them found science more difficult than other more interesting subjects, and concluded that further science studies should be avoided unless they were needed for some career purpose. Other more representative confirmations of negative evaluations of the science curricula across Australia (and in particular states) are now available in Australia, from the large scale reviews of Goodrum, Hackling and Rennie (2001) and from the TIMSS (2002). The former reported that well under half of secondary students find the science at school relevant to my future, useful ion everyday life, deals with things I am concerned with and helps me make decisions about my health.. TIMSS found that 62 and 65 % of females and males in Year 4 agree with I like learning science, but by Year 8 only 26 and 33 % still agree. Students in Japan have been doubly notably because of (a) their high performance in international measures of science achievement like TIMSS and PISA and (b) their very low response to items in these studies which relate to interest in science. Ogura (2003) reported an intra-national study of students across Years 6-9 (upper primary through Junior High); interest in a range of their subjects (including science) that make up that country’s national curriculum. There was a steady decline in interest in all these subjects which might have indicated an adolescent reaction against schooling generally. However, this study went on to ask the students a further question that is very meaningful in the Japanese context, If you discount the importance of this subject for university entrance, is it worth studying? Science and mathematics remained in decline while all the other subjects were seen more positively. It is thus ironic, at a time when some innovations in curriculum and other research-based findings are suggesting ways that these failures of school science might be corrected, to find school science under a new demands that come from quite outside science education, and which certainly do not have the correction of this malaise as a priority. The positive curricular and research findings can be characterized as moves from within science education, whereas the new demands are moves that come from without science education. In this paper I set out these two rather contrary challenges to the teaching of science as it is currently practised, and go on to suggest a way forward that could fruitfully combine the two.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: All Canadian jurisdictions require certain professionals to report suspected or observed child maltreatment. This study examined the types of maltreatment, level of harm and child functioning issues, controlling for family socioeconomic status, age and gender of the child reported by healthcare and non-healthcare professionals. Methods: We conducted chi-square analyses and logistic regression on a national child welfare sample from the 2003 Canadian Incidence Study of Reported Child Abuse and Neglect (CIS-2003) and compared the differences in professional reporting with its previous cycle (CIS-1998) using Bonferroni-corrected confidence intervals. Results: Our analysis of CIS-2003 data revealed that the majority of substantiated child maltreatment is reported to service agencies by non-healthcare professionals (57%), followed by non-professionals (33%) and healthcare professionals (10%). The number of professional reports increased 2.5 times between CIS-1998 and CIS-2003, while non-professionals’ increased 1.7 times. Of the total investigations, professional reports represented 59% in CIS-1998 and 67% in CIS-2003 (p<0.001). Compared to non-healthcare professionals, healthcare professionals more often reported younger children, children who experienced neglect and emotional maltreatment and those assessed as suffering harm and child functioning issues, but less often exposure to domestic violence. Conclusion: The results indicate that healthcare professionals played an important role in identifying children in need of protection considering harm and other child functioning issues. The authors discuss the reasons why underreporting is likely to remain an issue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the limits at which blur due to defocus, crossed-cylinder astigmatism, and trefoil became noticeable, troublesome or objectionable. Black letter targets (0.1, 0.35 and 0.6 logMAR) were presented on white backgrounds. Subjects were cyclopleged and had effectively 5 mm pupils. Blur was induced with a deformable, adaptive-optics mirror operating under open-loop conditions. Mean defocus blur limits of six subjects with uncorrected intrinsic higher-order ocular aberrations ranged from 0.18 ± 0.08 D (noticeable blur criterion, 0.1 logMAR) to 1.01 ± 0.27 D (objectionable blur criterion, 0.6 logMAR. Crossed-cylinder astigmatic blur limits were approximately 90% of those for defocus, but with considerable meridional influences. In two of the subjects, the intrinsic aberrations of the eye were subsequently corrected before the defocus and astigmatic blur were added. This resulted in only minor reductions in their blur limits. When assessed with trefoil blur and corrected intrinsic ocular aberrations, the ratio of objectionable to noticeable blur limits in these two subjects was much higher for trefoil (3.5) than for defocus (2.5) and astigmatism (2.2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the effect of orthokeratology on peripheral aberrations in two myopic volunteers. Methods: The subjects wore reverse geometry orthokeratology lenses overnight and were monitored for 2 weeks of wear. They underwent corneal topography, peripheral refraction (out to ±34° along the horizontal visual field) and peripheral aberration measurements across the 42° × 32° central visual field using a modified Hartmann-Shack aberrometer. Results: Spherical equivalent refraction was corrected for the central 25° of the visual fields beyond which it gradually returned to its preorthokeratology values. There were increases in axial coma, spherical aberration, higher order root mean square aberrations, and total root-mean-squared aberrations (excluding defocus). The rates of change of vertical and horizontal coma across the field changed in sign. Total root mean square aberrations showed a quadratic rate of change across the visual field which was greater subsequent to orthokeratology. Conclusion: Although orthokeratology can correct peripheral relative hypermetropia it induces dramatic increases in higher-order aberrations across the field

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Obesity associated with atypical antipsychotic medications is an important clinical issue for people with schizophrenia. The purpose of this project was to determine whether there were any differences in resting energy expenditure (REE) and respiratory quotient (RQ) between men with schizophrenia and controls. Method: Thirty-one men with schizophrenia were individually matched for age and relative body weight with healthy, sedentary controls. Deuterium dilution was used to determine total body water and subsequently fat-free mass (FFM). Indirect calorimetry using a Deltatrac metabolic cart was used to determine REE and RQ. Results: When corrected for FFM, there was no significant difference in REE between the groups. However, fasting RQ was significantly higher in the men with schizophrenia than the controls. Conclusion: Men with schizophrenia oxidised proportionally less fat and more carbohydrate under resting conditions than healthy controls. These differences in substrate utilisation at rest may be an important consideration in obesity in this clinical group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scoliosis is a three-dimensional spinal deformity which requires surgical correction in progressive cases. In order to optimize correction and avoid complications following scoliosis surgery, patient-specific finite element models (FEM) are being developed and validated by our group. In this paper, the modeling methodology is described and two clinically relevant load cases are simulated for a single patient. Firstly, a pre-operative patient flexibility assessment, the fulcrum bending radiograph, is simulated to assess the model's ability to represent spine flexibility. Secondly, intra-operative forces during single rod anterior correction are simulated. Clinically, the patient had an initial Cobb angle of 44 degrees, which reduced to 26 degrees during fulcrum bending. Surgically, the coronal deformity corrected to 14 degrees. The simulated initial Cobb angle was 40 degrees, which reduced to 23 degrees following the fulcrum bending load case. The simulated surgical procedure corrected the coronal deformity to 14 degrees. The computed results for the patient-specific FEM are within the accepted clinical Cobb measuring error of 5 degrees, suggested that this modeling methodology is capable of capturing the biomechanical behaviour of a scoliotic human spine during anterior corrective surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bridges are an important part of society's infrastructure and reliable methods are necessary to monitor them and ensure their safety and efficiency. Bridges deteriorate with age and early detection of damage helps in prolonging the lives and prevent catastrophic failures. Most bridges still in used today were built decades ago and are now subjected to changes in load patterns, which can cause localized distress and if not corrected can result in bridge failure. In the past, monitoring of structures was usually done by means of visual inspection and tapping of the structures using a small hammer. Recent advancements of sensors and information technologies have resulted in new ways of monitoring the performance of structures. This paper briefly describes the current technologies used in bridge structures condition monitoring with its prime focus in the application of acoustic emission (AE) technology in the monitoring of bridge structures and its challenges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aberrations affect image quality of the eye away from the line of sight as well as along it. High amounts of lower order aberrations are found in the peripheral visual field and higher order aberrations change away from the centre of the visual field. Peripheral resolution is poorer than that in central vision, but peripheral vision is important for movement and detection tasks (for example driving) which are adversely affected by poor peripheral image quality. Any physiological process or intervention that affects axial image quality will affect peripheral image quality as well. The aim of this study was to investigate the effects of accommodation, myopia, age, and refractive interventions of orthokeratology, laser in situ keratomileusis and intraocular lens implantation on the peripheral aberrations of the eye. This is the first systematic investigation of peripheral aberrations in a variety of subject groups. Peripheral aberrations can be measured either by rotating a measuring instrument relative to the eye or rotating the eye relative to the instrument. I used the latter as it is much easier to do. To rule out effects of eye rotation on peripheral aberrations, I investigated the effects of eye rotation on axial and peripheral cycloplegic refraction using an open field autorefractor. For axial refraction, the subjects fixated at a target straight ahead, while their heads were rotated by ±30º with a compensatory eye rotation to view the target. For peripheral refraction, the subjects rotated their eyes to fixate on targets out to ±34° along the horizontal visual field, followed by measurements in which they rotated their heads such that the eyes stayed in the primary position relative to the head while fixating at the peripheral targets. Oblique viewing did not affect axial or peripheral refraction. Therefore it is not critical, within the range of viewing angles studied, if axial and peripheral refractions are measured with rotation of the eye relative to the instrument or rotation of the instrument relative to the eye. Peripheral aberrations were measured using a commercial Hartmann-Shack aberrometer. A number of hardware and software changes were made. The 1.4 mm range limiting aperture was replaced by a larger aperture (2.5 mm) to ensure all the light from peripheral parts of the pupil reached the instrument detector even when aberrations were high such as those occur in peripheral vision. The power of the super luminescent diode source was increased to improve detection of spots passing through the peripheral pupil. A beam splitter was placed between the subjects and the aberrometer, through which they viewed an array of targets on a wall or projected on a screen in a 6 row x 7 column matrix of points covering a visual field of 42 x 32. In peripheral vision, the pupil of the eye appears elliptical rather than circular; data were analysed off-line using custom software to determine peripheral aberrations. All analyses in the study were conducted for 5.0 mm pupils. Influence of accommodation on peripheral aberrations was investigated in young emmetropic subjects by presenting fixation targets at 25 cm and 3 m (4.0 D and 0.3 D accommodative demands, respectively). Increase in accommodation did not affect the patterns of any aberrations across the field, but there was overall negative shift in spherical aberration across the visual field of 0.10 ± 0.01m. Subsequent studies were conducted with the targets at a 1.2 m distance. Young emmetropes, young myopes and older emmetropes exhibited similar patterns of astigmatism and coma across the visual field. However, the rate of change of coma across the field was higher in young myopes than young emmetropes and was highest in older emmetropes amongst the three groups. Spherical aberration showed an overall decrease in myopes and increase in older emmetropes across the field, as compared to young emmetropes. Orthokeratology, spherical IOL implantation and LASIK altered peripheral higher order aberrations considerably, especially spherical aberration. Spherical IOL implantation resulted in an overall increase in spherical aberration across the field. Orthokeratology and LASIK reversed the direction of change in coma across the field. Orthokeratology corrected peripheral relative hypermetropia through correcting myopia in the central visual field. Theoretical ray tracing demonstrated that changes in aberrations due to orthokeratology and LASIK can be explained by the induced changes in radius of curvature and asphericity of the cornea. This investigation has shown that peripheral aberrations can be measured with reasonable accuracy with eye rotation relative to the instrument. Peripheral aberrations are affected by accommodation, myopia, age, orthokeratology, spherical intraocular lens implantation and laser in situ keratomileusis. These factors affect the magnitudes and patterns of most aberrations considerably (especially coma and spherical aberration) across the studied visual field. The changes in aberrations across the field may influence peripheral detection and motion perception. However, further research is required to investigate how the changes in aberrations influence peripheral detection and motion perception and consequently peripheral vision task performance.