727 resultados para 1167
Resumo:
Purpose. To analyze the levels of the diadenosine polyphosphates Ap4A and Ap5A in tears, in a set of control subjects and in groups of symptomatic and nonsymptomatic persons with dry eye. Methods. Ninety-seven subjects participated in the study. The subjects were divided into five experimental groups: control subjects; symptomatic patients with normal tear secretion; symptomatic patients with low tear secretion; forced blink; and corneal mechanical stimulation provided by a gas esthesiometer. The Schirmer I test was used to measure and collect tear secretions from each subject. All samples were processed by high pressure liquid chromatography (HPLC) and their Ap4A and Ap5A levels determined. Results. The levels of Ap4A and Ap5A in tears were greater in all symptomatic patients than in control subjects, especially in symptomatic subjects with low tear secretion. Within the symptomatic subjects with normal tear secretion, significant differences in concentrations of Ap4A and Ap5A were found between men and women. In the forced blink experiments, concentrations of the Ap4A and Ap5A rose with increasing blink frequency. When the cornea was mechanically stimulated, the levels of Ap4A and Ap5A rose significantly during both moderate and high-flow rate tests. Conclusions. The increased levels of Ap4A and Ap5A in tears of patients with dry eye allow these dinucleotides to be used as objective biomarkers in dry eye conditions.
Resumo:
Purpose. To measure the increase in tear secretion evoked by selective stimulation of the different populations of sensory receptors of the cornea and conjunctiva by using moderate and intense mechanical, chemical, and cold stimuli. Methods. Six healthy subjects participated in the study. Tear secretion was measured in both eyes by the Schirmer’s test conducted under control conditions and after stimulation of the center of the cornea and the temporal conjunctiva with a gas esthesiometer. Mechanical stimulation consisted in three pulses of 3 seconds’ duration of warmed air (at 34°C on the eye surface) applied at moderate (170 mL/min) and high (260 mL/min) flow rates. Cold thermal stimulation was made with cooled air that produced a corneal temperature drop of −1°C or −4.5°C. Chemical (acidic) stimulation was performed with a jet of gas containing a mixture of 80% CO2 in air. Results. The basal volume of tear secretion increased significantly (P < 0.05, paired t-test) after stimulation of the cornea with high-flow mechanical stimuli (260 mL/min), intense cooling pulses (−4.5°C), and chemical stimulation (80% CO2). The same stimuli were ineffective when applied to the conjunctiva. Moderate mechanical (170 mL/min) and cold (−1°C) stimulation of the cornea or the conjunctiva did not change significantly the volume of tear secretion. Conclusions. Reflex tear secretion caused by corneal stimulation seems to be chiefly due to activation of corneal polymodal nociceptors, whereas selective excitation of corneal mechanonociceptors or cold receptors appears to be less effective in evoking an augmented lacrimal secretion. Conjunctival receptors stimulated at equivalent levels do not evoke an increased tear secretion.
Resumo:
Purpose.: To evaluate the levels of dinucleotides diadenosine tetraphosphate (Ap4A) and diadenosine pentaphosphate (Ap5A) in tears of patients wearing rigid gas permeable (RGP) contact lenses on a daily wear basis and of patients wearing reverse-geometry RGP lenses overnight for orthokeratology treatment. Methods.: Twenty-two young volunteers (10 females, 12 males; 23.47 ± 4.49 years) were fitted with an alignment-fit RGP lens (paflufocon B) for a month, and after a 15-day washout period they were fitted with reverse-geometry RGP lenses for corneal reshaping (paflufocon D) for another month. During each period, tears were collected at baseline day 1, 7, 15, and 28. Ap4A and Ap5A were measured by high-pressure liquid chromatography (HPLC). Additionally, corneal staining, break-up time (BUT), Schirmer test, and dryness symptoms were evaluated. Results.: Ap4A concentrations increased significantly from baseline during the whole period of daily wear of RGP lenses (P < 0.001); concentration was also significantly higher than in the orthokeratology group, which remained at baseline levels during the study period except at day 1 (P < 0.001) and day 28 (P = 0.041). While BUT and Schirmer remained unchanged in both groups, discomfort and dryness were significantly increased during alignment-fit RGP daily wear but not during the orthokeratology period. Conclusions.: Daily wear of RGP lenses increased the levels of Ap4A due to mechanical stimulation by blinking of the corneal epithelium, and this is associated with discomfort. Also, orthokeratology did not produce symptoms or signs of ocular dryness, which could be a potential advantage over soft contact lenses in terms of contact lens-induced dryness.
Resumo:
La presente nota tiene como objetivo exponer de manera breve la metodología del filtro Baxter-King como herramienta útil para el análisis de ciclos económicos y de extracción de tendencia. También se repasan las propiedades matemáticas del filtro Hodrick-Prescott, para comprender en qué aspectos difiere del Baxter-King. Como aplicación del filtro, se analizan series con periodicidad mensual (IMAE, IPPI, Base Monetaria) trimestral (PIB) y anual (PIB e Importaciones) y se concluye que a pesar de que no difieren mucho sus resultados, el segundo es superior al Hodrick-Prescott por cuanto permite que el investigador determine el tipo de información que desea aislar de las series.
Resumo:
Purpose.: To determine photopic and mesopic distance high-contrast visual acuity (HC-VA) and low-contrast visual acuity (LC-VA) in eyes with early age-related macular degeneration (AMD). Methods.: Measurements were made in 22 subjects with early AMD and 28 healthy control subjects. Inclusion criteria included a photopic HC-VA of 20/25 or better. Distance VA was measured using HC (96%) and LC (10%) Bailey-Lovie logMAR letter charts under photopic (85 cd/m2) and mesopic (0.1–0.2 cd/m2) luminance conditions. Results.: Mean mesopic distance HC-VA and LC-VA were significantly worse (0.1 logMAR and 0.28 logMAR, respectively) in the early AMD group than in the control group. Under mesopic conditions, the mean difference between LC-VA and HC-VA was significantly greater in the early AMD (0.45 logMAR) than the control group (0.27 logMAR). Mean differences between mesopic versus photopic HC-VA and mesopic versus photopic LC-VA were significantly greater in the early AMD than the control group (0.13 and 0.32 logMAR of difference between the means, respectively). Sensitivity and specificity were significantly greater for mesopic LC-VA than for mesopic HC-VA (Receiver Operating Characteristics, area under the curve [AUC], 0.94 ± 0.030 and 0.76 ± 0.067, respectively). AUC values for photopic HC-VA and LC-VA were below 0.70. Conclusions.: Visual acuity testing under low luminance conditions emerged as an optimal quantitative measure of retinal function in early AMD.
Resumo:
Órgano de difusión del Departamento y Cuerpo Académico de Botánica, FCB-UANL
Resumo:
Órgano de difusión del departamento y cuerpo académico de Botánica, FCB-UANL
Resumo:
Purpose: To study the population of intrinsically photosensitive retinal ganglion cells (melanopsin-expressing RGCs, m+RGCs) in P23H-1 rats, a rat model of inherited photoreceptor degeneration. Methods: At postnatal (P) times P30, P365, and P540, retinas from P23H dystrophic rats (line 1, rapid degeneration; and line 3, slow degeneration) and Sprague Dawley (SD) rats (control) were dissected as whole-mounts and immunodetected for melanopsin and/or Brn3a. The dendritic arborization of m+RGCs and the numbers of Brn3a+RGCs and m+RGCs were quantified and their retinal distribution and coexpression analyzed. Results: In SD rats, aging did not affect the population of Brn3a+RGCs or m+RGCs or the percentage that showed coexpression (0.27%). Young P23H-1 rats had a significantly lower number of Brn3a+RGCs and showed a further decline with age. The population of m+RGCs in young P23H-1 rats was similar to that found in SD rats and decreased by 22.6% and 28.2% at P365 and P540, respectively, similarly to the decrease of the Brn3a+RGCs. At these ages the m+RGCs showed a decrease of their dendritic arborization parameters, which was similar in both the P23H-1 and P23H-3 lines. The percentage of coexpression of Brn3a was, however, already significantly higher at P30 (3.31%) and increased significantly with age (10.65% at P540). Conclusions: Inherited photoreceptor degeneration was followed by secondary loss of Brn3a+RGCs and m+RGCs. Surviving m+RGCs showed decreased dendritic arborization parameters and increased coexpression of Brn3a and melanopsin, phenotypic and molecular changes that may represent an effort to resist degeneration and/or preferential survival of m+RGCs capable of synthesizing Brn3a.
Resumo:
Mode of access: Internet.
Resumo:
In this issue...Mine Rescue Training, Dr. Syntax, Engineers' Ball, Butte YMCA, Silver Bow Kiwanis Club, Kopper Kadets, Football, Sigma Xi, Montana Power Company
Resumo:
PURPOSE To investigate the cortical mechanisms that prevent diplopia in intermittent exotropia (X(T)) during binocular alignment (orthotropia). METHODS The authors studied 12 X(T) patients aged 5 to 22 years. Seventy-five percent had functional stereo vision with stereoacuity similar to that of 12 age-matched controls (0.2-3.7 min arc). Identical face images were presented to the two eyes for 400 ms. In one eye, the face was presented at the fovea; in the other, offset along the horizontal axis with up to 12° eccentricity. The task was to indicate whether one or two faces were perceived. RESULTS All X(T) patients showed normal diplopia when the nonfoveal face was presented to nasal hemiretina, though with a slightly larger fusional range than age-matched controls. However, 10 of 12 patients never experienced diplopia when the nonfoveal face was presented to temporal hemiretina (i.e., when the stimulus simulated exodeviation). Patients showed considerable variability when the single image was perceived. Some patients suppressed the temporal stimulus regardless of which eye viewed it, whereas others suppressed a particular eye even when it viewed the foveal stimulus. In two patients, the simulated exodeviation might have triggered a shift from normal to anomalous retinal correspondence. CONCLUSIONS Antidiplopic mechanisms in X(T) can be reliably triggered by purely retinal information during orthotropia, but the nature of these mechanisms varies between patients.
Resumo:
Purpose: The purpose of this study was to develop and validate a multivariate predictive model to detect glaucoma by using a combination of retinal nerve fiber layer (RNFL), retinal ganglion cell-inner plexiform (GCIPL), and optic disc parameters measured using spectral-domain optical coherence tomography (OCT). Methods: Five hundred eyes from 500 participants and 187 eyes of another 187 participants were included in the study and validation groups, respectively. Patients with glaucoma were classified in five groups based on visual field damage. Sensitivity and specificity of all glaucoma OCT parameters were analyzed. Receiver operating characteristic curves (ROC) and areas under the ROC (AUC) were compared. Three predictive multivariate models (quantitative, qualitative, and combined) that used a combination of the best OCT parameters were constructed. A diagnostic calculator was created using the combined multivariate model. Results: The best AUC parameters were: inferior RNFL, average RNFL, vertical cup/disc ratio, minimal GCIPL, and inferior-temporal GCIPL. Comparisons among the parameters did not show that the GCIPL parameters were better than those of the RNFL in early and advanced glaucoma. The highest AUC was in the combined predictive model (0.937; 95% confidence interval, 0.911–0.957) and was significantly (P = 0.0001) higher than the other isolated parameters considered in early and advanced glaucoma. The validation group displayed similar results to those of the study group. Conclusions: Best GCIPL, RNFL, and optic disc parameters showed a similar ability to detect glaucoma. The combined predictive formula improved the glaucoma detection compared to the best isolated parameters evaluated. The diagnostic calculator obtained good classification from participants in both the study and validation groups.
Resumo:
Combined media monoprints on photographic paper. 16" x 20", DNA/Transformation Series. Private Collection
Resumo:
O presente estudo tem como objetivo primordial refletir sobre duas diferentes plataformas de leitura: o livro interativo digital e o livro interativo impresso. Pretende-se compreender as diferenças entre os dois formatos e que questões levantam os mesmos, para a posterior elaboração de um objeto impresso. O mesmo visa reinterpretar os modelos de leitura e interação digitais, refletindo as especificidades deste meio e as possíveis contaminações operativas entre os dois suportes. Como forma de validar esta investigação, foi desenvolvido um objeto prático, um livro impresso, que serviu como suporte de experimentação. Assim, e dado o carácter lúdico do livro mostra-se pertinente estudar diferentes materiais e mecanismos, que levem o utilizador a desfrutar do objeto na sua plenitude.
Resumo:
En Colombia se ha podido establecer que la incidencia y mortalidad de la Enfermedad Renal Crónica Terminal continúan en aumento en los últimos 6 años a pesar de las estrategias de intervención para prevención y control de la enfermedad implementadas nivel nacional. Este trabajo busca establecer la línea de base para la población asegurada en Colombia, frente a la supervivencia de pacientes en terapia de remplazo renal (TRR).