983 resultados para “Horizontal ridge augmentation” AND “dental implants”
Resumo:
Recent years have seen a significant growth in surface modifications in titanium implants, resulting in shorter healing times in regions with low bone density. Among the different techniques, subtraction by chemical agents to increase oxidation has been applied for surface treatment of dental implants. However, this technique is generally unable to remove undesirable oxides, formed spontaneously during machining of titanium parts, raising costs due to additional decontamination stages. In order to solve this problem, the present study used plasma as an energy source to both remove these oxides and oxidize the titanium surface. In this respect, Ti disks were treated by hollow cathode discharge, using a variable DC power supply and vacuum system. Samples were previously submitted to a cleaning process using an atmosphere of Ar, H2 and a mixture of both, for 20 and 60 min. The most efficient cleaning condition was used for oxidation in a mixture of argon (60%) and oxygen (40%) until reaching a pressure of 2.2 mbar for 60 min at 500°C. Surfaces were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), atomic force microscopy (AFM), adhesion and cell proliferation. SEM showed less cell spreading and a larger number of projections orfilopodia in the treated samples compared to the control sample. AFM revealed surface defects in the treated samples, with varied geometry between peaks and valleys. Biological assays showed no significant difference in cell adhesion between treated surfaces and the control. With respect to cell proliferation, the treated surface exhibited improved performance when compared to the control sample. We concluded that the process was efficient in removing primary oxides as well as in oxidizing titanium surfaces
Resumo:
A 15-month-old DSH cat was presented with facial deformity secondary to multiple oral and maxillofacial fractures after being struck by an automobile. Multiple wires and dental acrylics were used for fracture repair.
Resumo:
In recent years there has been a significant growth in technologies that modify implant surfaces, reducing healing time and allowing their successful use in areas with low bone density. One of the most widely used techniques is plasma nitration, applied with excellent results in titanium and its alloys, with greater frequency in the manufacture of hip, ankle and shoulder implants. However, its use in dental implants is very limited due to high process temperatures (between 700 C o and 800 C o ), resulting in distortions in these geometrically complex and highly precise components. The aim of the present study is to assess osseointegration and mechanical strength of grade II nitrided titanium samples, through configuration of hollow cathode discharge. Moreover, new formulations are proposed to determine the optimum structural topology of the dental implant under study, in order to perfect its shape, make it efficient, competitive and with high definition. In the nitriding process, the samples were treated at a temperature of 450 C o and pressure of 150 Pa , during 1 hour of treatment. This condition was selected because it obtains the best wettability results in previous studies, where different pressure, temperature and time conditions were systematized. The samples were characterized by X-ray diffraction, scanning electron microscope, roughness, microhardness and wettability. Biomechanical fatigue tests were then conducted. Finally, a formulation using the three dimensional structural topology optimization method was proposed, in conjunction with an hadaptive refinement process. The results showed that plasma nitriding, using the hollow cathode discharge technique, caused changes in the surface texture of test specimens, increases surface roughness, wettability and microhardness when compared to the untreated sample. In the biomechanical fatigue test, the treated implant showed no flaws, after five million cycles, at a maximum fatigue load of 84.46 N. The results of the topological optimization process showed well-defined optimized layouts of the dental implant, with a clear distribution of material and a defined edge
Resumo:
This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study
Resumo:
The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components
Resumo:
Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures
Resumo:
It has been shown that the development of peri-implant mucositis is associated with biofilm accumulation. It is believed that the therapeutic approaches used in periodontal disease may have a positive effect in the cases of peri-implant disease. The aim of this study was to evaluate the effectiveness of non-surgical treatment of peri-implant mucositis, with or without the use of chlorhexidine 0,12% in subjects rehabilitated with osseointegrated implants. Thus, patients were randomly divided into test group (chlorhexidine surgical therapy) and control (non-surgical treatment). This therapy consisted of an adaptation of the (Full Mouth scalling and Root Planing) nonoperative protocol FMSRP, but without the use of ultrasound. The visible plaque index (VPI), gingival bleeding index (GBI), probing depth (PD), bleeding on probing (BOP) and keratinized mucosa clinical parameters were evaluated at baseline and at different times after treatment. The data were not normally distributed and the implant was considered the sampling unit. Data were analyzed using Fri edman and Wilcoxon chi-square (=5%), tests using the Statistical Package for Social Sciences 17.0 (SPSS). Thus, 119 implants were evaluated, 61 in the test group and 58 in the control group. The results showed statistically significant differences for the variables: average BTI implants in both groups (p<0,001), mean ISG implants both in the test group (p<0,001), and control (p= 0,006) of implants; PS for the test group (p< 0,001) and control (p = 0,015) and SS (p<0,001) in the two treatment groups. However, there was no statistically significant difference when the groups were compared. The PS and SS variables showed no statistically significant difference in any of independent interest to the study (age, sex, smoking, treatment group, keratinized mucosa at different times, peri-implant biotype, average VPI implants and GBI). Thus, it can be concluded that both the mechanical treatment isolated as its association with chlorhexidine mouthwash 0.12% can be used for the treatment of peri-implant mucositis. Moreover, the condition of oral h ygiene has improved between baseline and six months and the depth and bleeding on probing decreased after three and six months
Resumo:
The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques
Resumo:
The use of implant-supported prosthesis to replace missing teeth became a predictable treatment. Although high success rate has been reported, implant treatment is suitable to complications, failures, and limitations such as peri-implant bone loss after implant loading. Stress evaluation on the bone-abutment-implant interface has been carried out to develop new designs of prosthetic platform and to understand the stress distribution in this interface. Several types of prosthetic platforms are available such as external and internal hexagon, Morse cone connection, and the concept of platform switching. Therefore, this study aimed to critically describe the different options of prosthetic platforms in implant dentistry, by discussing their biomechanical concepts, clinical use, and advantages and disadvantages. It was observed that all types of prosthetic platforms provided high success rate of the implant treatment by following a strict criteria of indication and limitation. In conclusion, a reverse planning of implant treatment is strongly indicated to reduce implant overload, and the use of advanced surgical-prosthetic techniques is required to obtain a long-term success of oral rehabilitations.
Resumo:
The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.
Resumo:
The aim of this study was to perform a photoelastic analysis of stress distribution on straight and angulated implants with different crowns (screwed and cemented). Three models were made of photoelastic resin PL-2: model 1: external hexagon implant 3.75 x 10.00 mm at 0 degrees; model 2: external hexagon implant 3.75 x 10.00 mm at 17 degrees; model 3: external hexagon implant 3.75 x 10.00 mm at 30 degrees. Axial and oblique (45 degrees) load (100 N) was applied with a universal testing machine. The photoelastic fringes on the models were recorded with a digital camera and visualized in a graphic software for qualitative analysis. The axial loading generated the same pattern of stress distribution. The highest stresses were concentrated between medium and apical thirds. The oblique loading generated a similar pattern of stress distribution in the models with similar implant angulation; the highest stress was located on the cervical region opposite to implant angulation and on the apical third. It was concluded that the higher the implant angulation, the higher the stress value, independent of crown type. The screwed prostheses exhibited the highest stress concentration. The oblique load generated higher stress value and concentration than the axial load.
Resumo:
This article reports the 20-month clinical outcome of the use of 4 zygomatic implants with immediate occlusal loading and reverse planning for the retreatment of atrophic edentulous maxilla after failed rehabilitation with autogenous bone graft reconstruction and maxillary implants. The intraoral clinical examination revealed mispositioned and loosened implants underneath a maxillary complete denture. The panoramic radiograph showed 6 maxillary implants. One implant was displaced into the right maxillary sinus, and the implant anchored in the region of tooth 21 was fractured. The other implants presented peri-implant bone loss. The implants anchored in the regions of teeth 21 to 23 and 11 to 13 were first removed. After 2 months, the reverse planning started with placement of 4 zygomatic fixtures, removal of the implants migrated into the sinus cavity and anchored in the region of tooth 17, and installation of a fixed denture. After 20 months of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. The outcomes of this case confirm that the zygoma can offer a predictable anchorage and support function for a fixed denture in severely resorbed maxillae.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the effect of unilateral angular misfit of 100 Km on stress distribution of implant-supported single crowns with ceramic veneering and gold framework by three-dimensional finite element analysis. Two three-dimensional models representing a maxillary section of premolar region were constructed: group 1 (control)-crown completely adapted to the implant and group 2-crown with unilateral angular misfit of 100 Km. A vertical force of 100 N was applied on 2 centric points of the crown. The von Mises stress was used as an analysis criterion. The stress values and distribution in the main maps (204.4 MPa for group 1 and 205.0 MPa for group 2) and in the other structures (aesthetic veneering, framework, retention screw, implant, and bone tissue) were similar for both groups. The highest stress values were observed between the first and second threads of the retention screw. Considering the bone tissue, the highest stress values were exhibited in the peri-implant cortical bone. The unilateral angular misfit of 100 Km did not influence the stress distribution on the implant-supported prosthesis under static loading.
Resumo:
Purpose: This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis. Materials and Methods: Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/implant/screw system representation. To evaluate the effect of implant threads, two models were created: a model in which the implant threads were accurately simulated (precise model) and a model in which implants with a smooth surface (press-fit implant) were used (simplified model). An evaluation was performed on ANSYS software, in which a load of 133 N was applied at a 30-degree angulation and 2 mm off-axis from the long axis of the implant on the models, The Von Mises stresses were measured. Results: The precise model (1.45 MPa) showed higher maximum stress values than the simplified model (1.2 MPa). Whereas in the cortical bone, the stress values differed by about 36% (292.95 MPa for the precise model and 401.14 MPa for the simplified model), in trabecular bone (19.35 MPa and 20.35 MPa, respectively), the stress distribution and stress values were similar. Stress concentrations occurred around the implant neck and the implant apex. Conclusions: Considering implant and cortical bone analysis, remarkable differences in stress values were found between the models. Although the models showed different absolute stress values, the stress distribution was similar. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:1040-1044