990 resultados para wedge prism


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluid inclusions, petrofabric and microstructures studies of mylonites and cataclasites were used to establish the Itu-Jundiuvira Shear Zone (IJSZ) tectonic and metamorphic evolution. The quartz fabric indicates that prism {1000} slip was important during the deformation. This studies have showed that IJSZ changed from deeper crustal levels (12-15km) and ductile conditions to upper levels of about 4 to 6km and brittle strain conditions. -English summary

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Paraná Basin is a Western Gondwanan cratonic basin that is better defined as the Paraná depositional site, since it has a diverse history as a basin. Sedimentation started in the Ordovician-Silurian, followed by extensive marine Devonian deposition. A Late Paleozoic/ Triassic facies cycle wedge was clearly built during Pangean time. The Early Cretaceous was characterized by extensive basaltic lava flows immediately before the break-up of Pangea. Following these rifting and drifting processes, the basin's structural framework was totally rebuilt, generating new depositional sites in the Late Cretaceous to Tertiary. Based on more recent data, at least two different basins may be defined during the evolution of what was once considered a unique basin. Nevertheless, even if considered as a single basin, the sedimentary pile of the Paraná Basin has considerable economic potential, until now exploited only rudimentarily, except for its groundwater resources. Aggregates, limestones, clays, industrial sands, gems, dimension stones, hydrocarbons, coal, peat, and uranium are some of the potential mineral resources of this basin. Copyright © 1997 by V. H. Winston & Son, Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We reexamine the two-point function approaches used to study vacuum fluctuation in wedge-shaped regions and conical backgrounds. The appearance of divergent integrals is discussed and circumvented. The issue is considered in the context of a massless scalar field in cosmic string spacetime.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate whether the equality found for the response of static scalar sources interacting (i) with Hawking radiation in Schwarzschild spacetime and (ii) with the Fulling-Davies-Unruh thermal bath in the Rindler wedge is maintained in the case of electric charges. We find a finite result in the Schwarzschild case, which is computed exactly, in contrast with the divergent result associated with the infrared catastrophe in the Rindler case, i.e., in the case of uniformly accelerated charges in Minkowski spacetime. Thus the equality found for scalar sources does not hold for electric charges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Planar waveguides have been prepared on the ZrO2-(3-glycidiloxypropyl)trimethoxysilane (GPTS) system. Stable sols containing ZrO2 nanoparticles have been prepared and characterized by Photon Correlation Spectroscopy. The nanosized sol was embedded in (3-glycidoxipropyl)trimethoxisilane (GPTS) used as a hybrid host for posterior deposition. The opticalparameters of the waveguides such as refractive index, thickness and propagating modes and attenuation coefficient were measured at 632.8. 543.5 and 1550 nm by the prism coupling technique as a function of the Zr02 content. The planar waveguides present thickness of a few microns and support well confined propagating modes. Er doped samples display weak and broad (δλ≈96nm) emission at 1.5 μm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hybrid planar waveguides were prepared from Ti4+-acetylacetone (acac)-Ureasil sols deposited on glass substrates. Structural features have been investigated by spectroscopic measurements (Fourier Transform Infrared Spectroscopy (FTIR), X-ray Photoelectron Spectroscopy (XPS) and Raman scattering) and Small Angle X-ray Scattering (SAXS). Addition of Ti 4+-acac to the ureasil (Ti:Si molar ratio 1:1) leads to the formation of bonds between the Ti complex and the siloxane groups, whereas further addition of Ti4+ (Ti:Si molar ratio 5:1) leads to the additional formation of titanium-rich nanoclusters. The optical parameters of the waveguides such as refractive index, thickness, propagating modes and attenuation coefficient were measured at 632.8, 543.5 and 1550 nm by the prism coupling technique. The refractive index can be tuned by the Ti4+ relative content. The few microns thick planar waveguides support well confined propagating modes with low attenuation loss for all compositions. ©2006 Sociedade Brasileira de Química.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The radiopacity of esthetic restorative materials has been established as an important requirement, improving the radiographic diagnosis. The aim of this study was to evaluate the radiopacity of six restorative materials using a direct digital image system, comparing them to the dental tissues (enamel-dentin), expressed as equivalent thickness of aluminum (millimeters of aluminum). Five specimens of each material were made. Three 2-mm thick longitudinal sections were cut from an intact extracted permanent molar tooth (including enamel and dentin). An aluminum step wedge with 9 steps was used. The samples of different materials were placed on a phosphor plate together with a tooth section, aluminum step wedge and metal code letter, and were exposed using a dental x-ray unit. Five measurements of radiographic density were obtained from each image of each item assessed (restorative material, enamel, dentin, each step of the aluminum step wedge) and the mean of these values was calculated. Radiopacity values were subsequently calculated as equivalents of aluminum thickness. Analysis of variance (ANOVA) indicated significant differences in radiopacity values among the materials (P<0.0001). The radiopacity values of the restorative materials evaluated were, in decreasing order: TPH, F2000, Synergy, Prisma Flow, Degufill, Luxat. Only Luxat had significantly lower radiopacity values than dentin. One material (Degufill) had similar radiopacity values to enamel and four (TPH, F2000, Synergy and Prisma Flow) had significantly higher radiopacity values than enamel. In conclusion, to assess the adequacy of posterior composite restorations it is important that the restorative material to be used has enough radiopacity, in order to be easily distinguished from the tooth structure in the radiographic image. Knowledge on the radiopacity of different materials helps professionals to select the most suitable material, along with other properties such as biocompatibility, adhesion and esthetic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this paper is to study the mechanical behavior of concrete blocks and prisms when performing axial compression tests within the Brazilian base of knowledge, intending to foment data of this kind for a world-based network. The blocks were built using five different mixtures in which the quantity of cement and the compacting ratio (density) were varied (during the fabrication process). The three-course-high prisms were assembled using 1 cm (0.39 in.) thick full-bedded joints, always trying to leave the mortar's characteristics constant. The axial compression tests were conducted according to Brazilian practice code recommendations, because most of these standards are very similar to international practice codes. The compressive strength, strains, and rupture form of each mixture studied were recorded. Attempts were made to correlate the strength, efficiency ratio (block strength/prism strength) of the prisms, strains, and rupture form; with the quantity of cement and compacting ratio. The data are presented in tables and figures, and the obtained results are discussed throughout the text. Copyright © 2007, American Concrete Institute. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The microsatellite loci FCA045, FCA077, FCA008, and FCA096 are highly variable molecular markers which were used to determine the genetic diversity in 148 captive Leopardus sp. The PCR-amplified products of microsatellite loci were characterized in ABI Prism 310 Genetic Analyzer. Allele numbers, heterozygosity, polymorphism information content, exclusive allele number, and shared alleles were calculated. Sixty-five alleles were found and their sizes ranged from 116 to 216 bp in four microsatellite loci. The heterozygosity ranged from 0.36 to 0.81 in Leopardus pardalis, 0.57 to 0.67 in L. tigrinus and 0.80 to 0.92 in L. wiedii. The polymorphism information content was from 0.80 to 0.88 in L. pardalis, 0.76 to 0.88 in L. tigrinus and 0.77 to 0.90 in L. wiedii. The margay (L. wiedii) showed the highest index of polymorphism among the three species in this study. These results imply that microsatellite DNA markers can help in the study of the genetic diversity of Leopardus specimens. ©FUNPEC-RP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In spontaneously breathing cardiac patients, pulmonary artery pressure (PAP) can be accurately estimated from the transthoracic Doppler study of pulmonary artery and tricuspid regurgitation blood flows. In critically ill patients on mechanical ventilation for acute lung injury, the interposition of gas between the probe and the heart renders the transthoracic approach problematic. This study was aimed at determining whether the transesophageal approach could offer an alternative. METHODS: Fifty-one consecutive sedated and ventilated patients with severe hypoxemia (arterial oxygen tension/fraction of inspired oxygen < 300) were prospectively studied. Mean PAP measured from the pulmonary artery catheter was compared with several indices characterizing pulmonary artery blood flow assessed using transesophageal echocardiography: preejection time, acceleration time, ejection duration, preejection time on ejection duration ratio, and acceleration time on ejection duration ratio. In a subgroup of 20 patients, systolic PAP measured from the pulmonary artery catheter immediately before withdrawal was compared with Doppler study of regurgitation tricuspid flow performed immediately after pulmonary artery catheter withdrawal using either the transthoracic or the transesophageal approach. RESULTS: Weak and clinically irrelevant correlations were found between mean PAP and indices of pulmonary artery flow. A statistically significant and clinically relevant correlation was found between systolic PAP and regurgitation tricuspid flow. In 3 patients (14%), pulmonary artery pressure could not be assessed echocardiographically. CONCLUSIONS: In hypoxemic patients on mechanical ventilation, mean PAP cannot be reliably estimated from indices characterizing pulmonary artery blood flow. Systolic PAP can be estimated from regurgitation tricuspid flow using either transthoracic or transesophageal approach. © 2008 American Society of Anesthesiologists, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in situ study investigated, using scanning electron microscopy, the effect of stimulated saliva on the enamel surface of bovine and human substrates submitted to erosion followed by brushing abrasion immediately or after one hour. During 2 experimental 7-day crossover phases, 9 previously selected volunteers wore intraoral palatal devices, with 12 enamel specimens (6 human and 6 bovine). In the first phase, the volunteers immersed the device for 5 minutes in 150 ml of a cola drink, 4 times a day (8h00, 12h00, 16h00 and 20h00). Immediately after the immersions, no treatment was performed in 4 specimens (ERO), 4 other specimens were immediately brushed (0 min) using a fluoride dentifrice and the device was replaced into the mouth. After 60 min, the other 4 specimens were brushed. In the second phase, the procedures were repeated but, after the immersions, the volunteers stimulated the salivary flow rate by chewing a sugar-free gum for 30 min. Enamel superficial alterations of all specimens were then evaluated using a scanning electron microscope. Enamel prism core dissolution was seen on the surfaces submitted to erosion, while on those submitted to erosion and to abrasion (both at 0 and 60 min) a more homogeneous enamel surface was observed, probably due to the removal of the altered superficial prism layer. For all the other variables - enamel substrate and salivary stimulation the microscopic pattern of the enamel specimens was similar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of the type of rotary cutting instrument on bone repair after osteotomy in swine jaw, was evaluated using digital and densitometric radiographic examinations, at controlled times. Two cross-sectional dissections were made through the base of the right jaw, one using a high speed rotary instrument and the other using low speed, both with liquid cooling. After established periods the animals were sacrificed and their jaws removed for direct and indirect digital radiographic and densitometric studies using the CROMOX, DIGORA and ODR systems. In the initial periods (7 and 28 days) the bone density was higher in osteotomy areas performed with high rotation speeds, and in the final periods (60 and 90 days) the bone density was higher in the osteotomies performed with low rotation, indicating a better final bone repair with the use of low rotation. The qualitative analysis of the repair process was made by the ODR system which obtained three-dimensional and coloured digital images, which enable the bone thickness to be measured using an aluminium wedge. This showed that by twenty-eight days the bone repair was already apparently complete. © 2010 SECOM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Calculated indexes from laboratory measurements and the determination of plasma markers are commonly used in cardiovascular risk assessment. Objective: To use triglycerides/high-density lipoprotein cholesterol (HDL-C) ratio, estimate of low-density lipoprotein (LDL) particle size and high sensitive C-reactive protein (hs-CRP) levels to the clinical and laboratorial assessment of coronary risk among patients with coronary disease. Material and methods: Sixty patients were chosen accordingly, 36 female (F) (65 ± 9 years of age) and 24 male (M) (55 ± 10 years of age) diagnosed with stable ischemic cardiopathy at Ana Neri Hospital, Salvador, Bahia, Brazil. The investigation was carried out at the Clinical Biochemistry Laboratory of the College of Pharmacy at Federal University of Bahia (UFBA). Blood samples were collected after a 12-hour fast to determine hs-CRP, lipid profile and risk indicators. All data were assessed through Syncron LX®20 Beckman Coulter. The inferential analysis results were considered significant when p ≤ 5%. Data analysis was carried out with GraphPad Prism® (4.03 version) software. Results: Data analysis showed a positive correlation between hs-CRP and triglycerides/HDL-C ratio only among women (r = 0.4; p = 0.0442), n = 36. The analysis of other parameters did not show any significance. Conclusion: The triglycerides/HDL-C ratio and hs-CRP may be used as indicators of increase in cardiovascular risk among women with coronary artery disease (CAD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Metabolic and morphological changes associated with excessive abdominal fat, after the introduction of Antiretroviral Therapy, increase the risk of cardiovascular disease in people living with HIV/AIDS(PLWHA). Accurate methods for body composition analysis are expensive and the use of anthropometric indices is an alternative. However the investigations about this subject in PLWHA are rare, making this research very important for clinical purpose and to advance scientific knowledge. The aim of this study is to correlate results of anthropometric indices of evaluation of body fat distribution with the results obtained by Dual-energy X-Ray Absorptiometry(DEXA) , in people living with HIV/AIDS. Methods. The sample was of 67 PLWHA(39 male and 28 female), aged 43.6+7.9 years. Body mass index, conicity index, waist/hip ratio, waist/height ratio and waist/thigh were calculated. Separated by sex, each index/ratio was plotted in a scatter chart with linear regression fit and their respective Pearson correlation coefficients. Analyses were performed using Prism statistical program and significance was set at 5%. Results: The waist/height ratio presented the highest correlation coefficient, for both male (r=0.80, p<0.001) and female (r=0.87, p <001), while the lowest were in the waist/thigh also for both: male group (r=0.58, p<0.001) and female group (r=0.03, p=0.86). The other indices also showed significant positive correlation with DEXA. Conclusion: Anthropometric indices, especially waist/height ratio may be a good alternative way to be used for evaluating the distribution of fat in the abdominal region of adults living with HIV/ADIS. © 2012 Segatto et al.; licensee BioMed Central Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Includes bibliography