992 resultados para thermal radiation
Resumo:
PURPOSE: In this study, we investigated the mechanisms by which temozolomide enhances radiation response in glioblastoma cells. EXPERIMENTAL DESIGN: Using a panel of four primary human glioblastoma cell lines with heterogeneous O(6)-methylguanine-DNA methyltransferase (MGMT) protein expression, normal human astrocytes, and U87 xenografts, we investigated (a) the relationship of MGMT status with efficacy of temozolomide-based chemoradiation using a panel of in vitro and in vivo assays; (b) underlying mechanisms by which temozolomide enhances radiation effect in glioblastoma cells; and (c) strategies to overcome resistance to radiation + temozolomide. RESULTS: Temozolomide enhances radiation response most effectively in glioblastomas without detectable MGMT expression. On concurrent radiation + temozolomide administration in MGMT-negative glioblastomas, there seems to be decreased double-strand DNA (dsDNA) repair capacity and enhanced dsDNA damage compared either with radiation alone or with sequentially administered temozolomide. Our data suggest that O(6)-benzylguanine can enhance the antitumor effects of concurrent radiation + temozolomide in MGMT-positive cells by enhancing apoptosis and the degree of dsDNA damage. O(6)-Benzylguanine was most effective when administered concurrently with radiation + temozolomide and had less of an effect when administered with temozolomide in the absence of radiation or when administered sequentially with radiation. Our in vivo data using U87 xenografts confirmed our in vitro findings. CONCLUSIONS: The present study shows that temozolomide enhances radiation response most effectively in MGMT-negative glioblastomas by increasing the degree of radiation-induced double-strand DNA damage. In MGMT-positive glioblastomas, depletion of MGMT by the addition of O(6)-benzylguanine significantly enhances the antitumor effect of concurrent radiation + temozolomide. These are among the first data showing mechanisms of synergy between radiation and temozolomide and the effect of MGMT.
Resumo:
Aim: 125I-iododeoxyuridine is a potential Auger radiation therapy agent. Its incorporation in DNA of proliferating cells is enhanced by fluorodeoxyuridine. Here, we evaluated therapeutic activities of 125I-iododeoxyuridine in an optimized fluorodeoxyuridine pre-treatment inducing S-phase synchronization. Methods: After S-phase synchronization by fluorodeoxyuridine, cells were treated with 125I-iododeoxyuridine. Apoptosis analysis and S-phase synchronization were studied by flow cytometry. Cell survival was determined by colony-forming assay. Based on measured growth parameters, the number of decays per cell that induced killing was extrapolated. Results: Treatment experiments showed that 72 to 91% of synchronized cells were killed after 0.8 and 8 kBq/ml 125I-iododeoxyuridine incubation, respectively. In controls, only 8 to 38% of cells were killed by corresponding 125I-iododeoxyuridine activities alone and even increasing the activity to 80 kBq/ml gave only 42 % killing. Duplicated treatment cycles or repeated fluorodeoxyuridine pre-treatment allowed enhancing cell killing to >95 % at 8 kBq/ml 125I-iododeoxyuridine. About 50 and 160 decays per S-phase cells in controls and S-phase synchronization, respectively, were responsible for the observed cell killing at 0.8 kBq/ml radio-iododeoxyuridine. Conclusion: These data show the successful application of fluorodeoxyuridine that provided increased 125I-iododeoxyuridine Auger radiation cell killing efficacy through S-phase synchronization and high DNA incorporation of radio-iododeoxyuridine.
Resumo:
OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."
Resumo:
Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).
Resumo:
The objective of this work was to develop neural network models of backpropagation type to estimate solar radiation based on extraterrestrial radiation data, daily temperature range, precipitation, cloudiness and relative sunshine duration. Data from Córdoba, Argentina, were used for development and validation. The behaviour and adjustment between values observed and estimates obtained by neural networks for different combinations of input were assessed. These estimations showed root mean square error between 3.15 and 3.88 MJ m-2 d-1 . The latter corresponds to the model that calculates radiation using only precipitation and daily temperature range. In all models, results show good adjustment to seasonal solar radiation. These results allow inferring the adequate performance and pertinence of this methodology to estimate complex phenomena, such as solar radiation.
Resumo:
The aim of this study was to investigate the radiation exposure of the Swiss population to interventional procedures. A nationwide survey was conducted in Switzerland. The annual effective dose per capita due to interventional procedures was found to be 0.14 mSv, corresponding to 12% of the total dose. Coronary angiography and percutaneous coronary interventions were found to be the most frequent and the most irradiating interventional procedures, accounting for 52% of the total examination frequency and 64% of the dose delivered to the population. Switzerland stands at the same level as other countries in terms of effective dose per capita due to interventional radiology.
Resumo:
The major objective of this research project was to use thermal analysis techniques in conjunction with x-ray analysis methods to identify and explain chemical reactions that promote aggregate related deterioration in portland cement concrete. Twenty-two different carbonate aggregate samples were subjected to a chemical testing scheme that included: • bulk chemistry (major, minor and selected trace elements) • bulk mineralogy (minor phases concentrated by acid extraction) • solid-solution in the major carbonate phases • crystallite size determinations for the major carbonate phases • a salt treatment study to evaluate the impact of deicer salts Test results from these different studies were then compared to information that had been obtained using thermogravimetric analysis techniques. Since many of the limestones and dolomites that were used in the study had extensive field service records it was possible to correlate many of the variables with service life. The results of this study have indicated that thermogravimetric analysis can play an important role in categorizing carbonate aggregates. In fact, with modern automated thermal analysis systems it should be possible to utilize such methods on a quality control basis. Strong correlations were found between several of the variables that were monitored in this study. In fact, several of the variables exhibited significant correlations to concrete service life. When the full data set was utilized (n = 18), the significant correlations to service life can be summarized as follows ( a = 5% level): • Correlation coefficient, r, = -0.73 for premature TG loss versus service life. • Correlation coefficient, r, = 0.74 for relative crystallite size versus service life. • Correlation coefficient, r, = 0.53 for ASTM C666 durability factor versus service life. • Correlation coefficient, r, = -0.52 for acid-insoluble residue versus service life. Separation of the carbonate aggregates into their mineralogical categories (i.e., calcites and dolomites) tended to increase the correlation coefficients for some specific variables (r sometimes approached 0.90); however, the reliability of such correlations was questionable because of the small number of samples that were present in this study.
Resumo:
This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDI(vol)) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDI(vol): 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.
Resumo:
The most extensively studied Heusler alloys are those based on the Ni-Mn-Ga system. However, to overcome the high cost of Gallium and the usually low martensitic transformation temperature, the search for Ga-free alloys has been recently attempted, particularly, by introducing In, Sn or Sb. In this work, two alloys (Mn50Ni35.5In14.5 and Ni50Mn35In15) have been obtained by melt spinning. We outline their structural and thermal behaviour. Mn50Ni35.5In14.5 alloy has the transformation above room temperature whereas Ni50Mn35In15 does not have this transformation in the temperature range here analyzed
Resumo:
A discussion on the importance and pathogenesis of radiation-induced pneumonitis and fibrosis is provided, with a special focus on the role of the immune system. The need to understand this interaction is highlighted in view of emerging therapeutic potential.
Resumo:
The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.