925 resultados para support surface functional group influence


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of surface treatment on the shear bond strength between a Co-Cr alloy and two ceramics.Materials and Methods: Forty-eight metal cylinders were made (thickness: 4 mm, height: 3.7 mm) according ISO TR 11405. The 48 metallic cylinders were divided into four groups (n = 12), according to the veneering ceramic (StarLight Ceram and Duceram Kiss) and surface treatments: air-particle abrasion with Al(2)O(3) or tungsten drill (W). Gr1: StarLight + Al(2)O(3); Gr2: StarLight + W; Gr3: Duceram + Al(2)O(3); and Gr4: Duceram + W. The specimens were aged using thermal cycling (3000 x, 5 to 55 degrees C, dwell time: 30 seconds, transfer time: 2 seconds). The shear test was performed with a universal testing machine, using a load cell of 100 kg (speed: 0.5 mm/min) and a specific device. The bond strength data were analyzed using ANOVA and Tukey's test (5%), and the failure modes were analyzed using an optical microscope (30x).Results: The means and standard deviations of the shear bond strengths were (MPa): G1 (57.97 +/- 11.34); G2 (40.62 +/- 12.96); G3 (47.09 +/- 13.19); and G4 (36.80 +/- 8.86). Ceramic (p = 0.03252) and surface treatment (p = 0.0002) significantly affected the mean bond strength values.Conclusions: Air-particle abrasion with Al(2)O(3) improved the shear bond strength between metal and ceramics used.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: the purpose of the present study was to investigate the effects of ND:YLF laser irradiation (1.31 J/cm(2); 250 mJ per pulse), acid etching, and hypermineralization on the shear bond strength (SBS) of the Scotchbond Multi-Purpose Plus (3M Dental Products) bonding system. Summary Background Data: Previous studies had shown that the pretreatment of the dentin substrate with laser irradiation can influence the SBS, Methods: Sixty bovine incisors were selected and stored at -18 degrees C, Dentinal buccal surface was exposed and radiographs were taken to control dentin thickness, the specimens were separated into 2 groups: (1) the control, which was kept in distilled water at 4 degrees C; (2) the hypermineralized, which was kept in hypermineralizing solution at 4 degrees C for 14 days, Each group was divided into 3 subgroups according to the type of dentin pretreatment used: M (acid etching + primer + bond); AL (acid etching + primer + bond + laser); and LA (laser + acid etching + primer + bond). A standard composite resin cylinder (Z100-3M) was bonded to the dentinal surface and the SBS performed on an Instron machine (500 Kg load cell at 0.5 mm/min), followed by scanning electron microscopy (SEM) and x-ray diffraction analysis. Results: Analysis of variance (ANOVA) determined that the pretreatments influenced the SBS values (p < 0.05): AL (9.96 MPa), M (7.28 MPa), and LA (4.87 MPa), the interaction between the group and pretreatment factors also influenced the SBS (p < 0.05). The highest values were obtained for the interaction control/AL (11.64 MPa), Conclusion: the results suggested that dentin treatment with laser after the application of the adhesive system is efficient in achieving higher bond strength and is promising as a possible new adhesive substrate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pb0.91Ca0.1TiO3 powders (PCT) were prepared by mechanochemical synthesis from high-energy ball milling process. The influence of milling time on the phase formation, crystal structure, specific surface area, density and powder morphology was observed. We adopted the Rietveld refinement technique to investigate the crystal structure of the PCT powders. Scanning electron microscopy (SEM) analysis revealed that PCT powders milled for 5 h showed a wide distribution of particle agglomerates while milled for 35 h showed a decrease in agglomerates size. Further prolongation of milling time resulted in the agglomerates growth. (C) 2006 Elsevier Ltd and Techna Group S.r.l. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The properties of edible films are influenced by several factors, including thickness. The purpose of this paper was to study the influence of thickness on the viscoelasticity properties, water vapor permeability, color and opacity of cassava starch edible films. These films were prepared by a casting technique, the film-forming solutions were 1, 2, 3 and 4% (w/v) of starch, heated to 70degreesC. Different thicknesses were obtained by putting 15 to 70 g of each solution on plexiglass plates. After drying at 30degreesC and ambient relative humidity, these samples were placed for 6 days at RH of 75%, at 22degreesC. The sample thicknesses were determined by a digital micrometer (+/-0.001 mm), as the average of nine different points. The viscoelasticity properties were determined by stress relaxation tests with a texture analyser TA.XT2i (SMS), being applied the Burgers model of four parameters. The water vapor permeability was determined with a gravimetric method, and color and opacity were determined using a Miniscan XE colorimeter, operated according to the Hunterlab method. All the tests were carried out in duplicate at 22degreesC. Practically, the four visco-elasticity properties calculated by the Burgers model had the same behavior, increasing with the thickness of all films, according to a power law model. The water vapor permeability and the color difference increased linearly with the thickness (0.013-0.144 mm) of all films prepared with solution of 1 to 4% of starch. on the other hand, the effect of the variation of the thickness over the opacity, was more important in the films with 1 and 2% of starch. It can be concluded that the control of the thickness in the elaboration of starch films by the casting technique is of extreme importance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Brazil is a wide country with huge contrasts. Its peculiarities can highlight environmental factors that could influence the frequencies of different cancers. The standard treatment and results achieved from several different areas of the country may not be found in others. The establishment of a national cooperative group has the potential to improve outcomes. The The Brazilian Cooperative Group on Pediatric Patients with Myelodysplastic Syndrome (BCG-MDS-PED) was first organized in January 1997 as a working group of hematologists, pediatric oncologists, pediatric-hematologists, molecular biologists and other professionals in order to study pediatric (age < 18 years) MDS. Six distinct subcommittees constituted with members from several universities: cytology, histopathology, clinical, cytogenetics, molecular biology and epidemiology. The goals of the BCG-MDS-PED were: (i) to offer support for diagnosis and orientation for treatment; (ii) educational Support for the colleagues all over the country and (iii) research on pathogenesis and new approaches for pediatric MDS patients. There are socio-economical differences among the five regions of the country. The BCG-MDS-PED believes that it is absolutely necessary to Study the clinical, cellular, molecular and epidemiological aspects of MDS, taking in account these peculiar differences among populations and regions. Since 1997, 114 pediatric cases were referred to the BCG-MDS-PED from 21 centres. Seven Brazilian states have sent cases to the group, 31 patients were referred from universities, 73 patients from pediatric oncology units (foundations) and 10 patients came from private clinics. Some of these patients have been followed up and/or treated by the physician who referred them to the BCG-MDS-PED for confirmation of the initial diagnosis. The majority of these physicians have required orientation on diagnostic and treatment issues, as well as to complete cytogenetic and molecular studies. From these 114 patients, 64 patients were confirmed as MDS. We believe that, the more numerous the MDS-studied cases, the more experienced will be the referee group on clinical and laboratory features on childhood MDS in Brazil. (C) 2002 Published by Elsevier B.V. Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Unlike the muscle protein, alpha-tropomyosin expressed in Escherichia coli does not bind actin, does not exhibit head-to-tail polymerization, and does not inhibit actomyosin ATPase activity in the absence of troponin. The only chemical difference between recombinant and muscle tropomyosins is that the first methionine is not acetylated in the recombinant protein (Hitchcock-DeGregori, S. E., and Heald, R. W. (1987) J. Biol. Chem. 262, 9730-9735). We expressed three fusion tropomyosins in E. coli with 2, 3, and 17 amino acids fused to its amino terminus. Ah three fusions restored actin binding, head-to-tail polymerization, and the capacity to inhibit the actomyosin ATPase to these unacetylated tropomyosins. Unlike larger fusions, the small fusions of 2 and 3 amino acids do not interfere with regulatory function. Therefore the presence of a fused dipeptide at the amino terminus of unacetylated tropomyosin is sufficient to replace the function of the N-acetyl group present in muscle tropomyosin. A structural interpretation for the function of the acetyl group, based on our results and the coiled coil structure of tropomyosin, is presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

THE INFLUENCE OF CHEMICAL PLAQUE CONTROL, using topically applied 0.12% chlorhexidine, on the severity of cyclosporin A (CsA)-induced gingival overgrowth (GO) was evaluated. Forty Holtzman rats were divided into four groups: 1) control; 2) cyclosporin A: a 10mg/kg/day subcutaneous dose of CsA; 3) chlorhexidine: 0.12% chlorhexidine (CHX) was applied to the buccal surface of the right mandibular molars; and 4) cyclosporin A/chlorhexidine: a combination of the treatment described for cyclosporin A and chlorhexidine groups. The animals were fed a high sucrose diet during the experiment and were sacrificed after 14 and 21 days. The histometric analysis revealed a significant increase in buccal gingival area in the cyclosporin A group compared to other groups (P < 0.01) after 21 days. The epithelium thickness of the buccal gingiva was significantly increased in the cyclosporin A group, compared to the control group (P < 0.05). The cyclosporin A/chlorhexidine group exhibited statistically significantly lower gingival overgrowth than the cyclosporin A group. These findings, if replicated in human studies, suggest that topically applied 0.12% chlorhexidine may be a valuable measure in the management of cyclosporin-induced gingival overgrowth.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To determine the influence of different dentin treatments on the microtensile bond strengths of adhesive resins to dentin. Methods: Fifteen human molars were ground to 600-grit to obtain flat root-dentin surfaces. Five different dentin treatments were evaluated: Group 1 - 10% phosphoric acid for 30 seconds; Group 2 - 37% phosphoric acid for 15 seconds; Group 3 - air-abrasion for 10 seconds followed by 10% phosphoric acid for 30 seconds; Group 4 - air-abasion for 10 seconds followed by 37% phosphoric acid for 15 seconds. The dental adhesive (OptiBond Solo Plus) was applied according to manufacturer's instructions and followed by composite (Z100) application to provide sufficient bulk for microtensile bond testing. All samples were placed in distilled water for 24 hours at 37degreesC, thermocycled for 500 cycles in distilled water at 10degreesC and 50degreesC, and serially sliced perpendicular to the adhesive surface and subjected to tensile forces (0.5 mm/minute). Additional samples were prepared for SEM to observe the adhesive interface. Results: Group 2 exhibited significantly (P< 0.05) lower bond strength values than all other treatments. The bond strengths of the different conditions were (in MPa): Group 1: 43.0 +/- 16.1; Group 2: 29.2 +/- 8.3; Group 3: 48.1 +/- 14.2; Group 4: 41.0 +/- 9.3. The dentin treated with phosphoric acid 37% for 15 seconds showed the lowest values of microtensile bond strength. The results obtained with Groups 1, 3 and 4 were statistically similar.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: the purpose of this study was to evaluate, histologically and radiographically, the effect of photodynamic therapy on the progression of experimentally induced periodontal disease in rats.Methods: Ligatures were placed at the first mandibular molar in rats. The animals were divided into four groups: group 1 (C) received no treatment; group 2 was treated topically with methylene blue (MB; 100 mu g/ml); group 3 was treated with low-level laser therapy (LLLT); and group 4 was treated topically with methylene blue followed by LLLT (4.5 J/cm(2)) (photodynamic therapy; PDT). Rats were sacrificed 5, 15, or 30 days postoperatively. Standardized radiographs were taken to measure bone loss around the mesial root surface of the first molar. Data were analyzed statistically (analysis of variance and Tukey test; P < 0.05). A scoring system was used to evaluate the connective tissue, periodontal ligament, and alveolar bone histologically. Data were analyzed statistically (Kruskal-Wallis test; P < 0.05).Results: Radiographic examination showed that there was significantly less bone loss in Group PDT compared to Group C at 5 and 15 days postoperatively. There was no significant difference in bone loss at 30 days. At 15 days, the histologic results showed significant differences in the extent of inflammatory reaction in the gingival tissue, with a greater extent of chronic inflammatory reaction in Group LLLT.Conclusion: PDT transiently reduced the periodontal tissue destruction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Statement of the Problem: the ceramic composition and surface microstructure of all-ceramic restorations are important components of an effective bonding substrate. Hydrofluoric acid and sandblasting are well-known procedures for surface treatment; however, surface treatment for high alumina-containing and lithium disilicate ceramics have not been fully investigated.Purpose: This in vitro study evaluated the tensile bond strength of resin cement to two types of ceramic systems with different surface treatments.Methods and Materials: Thirty specimens of each ceramic system were made according to the manufacturer's instructions and embedded in polyester resin. Specimens of In-Ceram Alumina [1] and IPS Empress 2 [E] were distributed to three groups with differing surface treatments (n=10): sandblasting with 50 jam aluminum oxide (APA); sandblasting with 110 pm aluminum oxide modified with silica particles (ROCATEC System-RS); a combination of sandblasting with APA and 10% hydrofluoric acid etching (HA) for two minutes on In-Ceram and for 20 seconds for IPS Empress 2. After the respective surface treatments, all the specimens were silanated, and Rely-X resin cement was injected onto the ceramic surface and light polymerized. The specimens were stored in distilled water at 37 degrees C for 24 hours and thermally cycled 1,100 times (5 degrees C/55 degrees C). The tensile bond strength test was performed in a universal testing machine at a 0.5 mm/minute crosshead speed.Results: the mean bond strength values (AWa) for IPS Empress 2 were 12.01 +/- 5.93 (EAPA), 10.34 +/- 1.77 (ERS) and 14.49 +/- 3.04 (EHA). The mean bond strength values for In-Ceram Alumina were 9.87 +/- 2.40 JAPA) and 20.40 +/- 6.27 (IRS). All In-Ceram specimens treated with 10% hydrofluoric acid failed during thermal cycling.Conclusion: the Rocatec system was the most effective surface treatment for In-Ceram Alumina ceramics; whereas, the combination of aluminum oxide sandblasting and hydrofluoric acid etching for 20 seconds worked more effectively for Empress 2 ceramics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Immunosuppressive agents may induce severe changes on bone metabolism and may impair the osseointegration process during the implant healing. No data are available concerning the influence of cyclosporin A on dental implants previously integrated to the bone. The aim of this study was to evaluate the influence of cyclosporin A administration on the mechanical retention of bone previously integrated to dental implants.Methods: Eighteen female New Zealand rabbits were submitted to an implant surgery. Each animal received one commercial dental implant of 10 x 3.75 mm. After 12 weeks of an undisturbed healing period, six animals were randomly sacrificed and the removal torque test was performed (group A). In addition, six animals were submitted to a daily injection of cyclosporin A in a dosage of 10 mg/kg (group C), and six animals received saline solution as a control (group B). After 12 weeks of cyclosporin A administration, groups B and C were sacrificed and submitted to a removal torque test in which higher values can be interpreted as higher mechanical bone retention to the implant surface or higher osseointegration.Results: the removal torque results were 30.5 (+/- 9.8) Ncm for group A, 50.17 (+/- 17.5) Ncm for group B, and 26 (+/- 7.8) Ncm for group C. The statistical analysis showed significant differences between groups A and B (P < 0.05) and groups B and C (P < 0.01).Conclusion: Cyclosporin A administration may impair the mechanical retention of dental implants previously integrated to the bone.