967 resultados para restraint installation
Resumo:
Often, road construction causes the need to create a work zone. In these scenarios, portable concrete barriers (PCBs) are typically installed to shield workers and equipment from errant vehicles as well as prevent motorists from striking other roadside hazards. For an existing W-beam guardrail system installed adjacent to the roadway and near the work zone, guardrail sections are removed in order to place the portable concrete barrier system. The focus of this research study was to develop a proper stiffness transition between W-beam guardrail and portable concrete barrier systems. This research effort was accomplished through development and refinement of design concepts using computer simulation with LS-DYNA. Several design concepts were simulated, and design metrics were used to evaluate and refine each concept. These concepts were then analyzed and ranked based on feasibility, likelihood of success, and ease of installation. The rankings were presented to the Technical Advisory Committee (TAC) for selection of a preferred design alternative. Next, a Critical Impact Point (CIP) study was conducted, while additional analyses were performed to determine the critical attachment location and a reduced installation length for the portable concrete barriers. Finally, an additional simulation effort was conducted in order to evaluate the safety performance of the transition system under reverse-direction impact scenarios as well as to select the CIP. Recommendations were also provided for conducting a Phase II study and evaluating the nested Midwest Guardrail System (MGS) configuration using three Test Level 3 (TL-3) full-scale crash tests according to the criteria provided in the Manual for Assessing Safety Hardware, as published by the American Association of Safety Highway and Transportation Officials (AASHTO).
Resumo:
Photodynamic therapy (PDT) has been used as an adjunct to cytoreductive surgery in patients with malignant pleura mesothelioma (MPM). However, it was associated with substantial side effects and found to be only of modest clinical benefit. In contrast, Visudyne®-mediated low-dose PDT has been shown to selectively increase the concentration of macromolecular cytostatic compounds in various tumors grown subpleurally on rodent lungs. Consequently, it was thought that PDT-assisted enhanced tumor penetration for cytostatic agents might be better suited to achieve additional tumor control after cytoreductive surgery for mesothelioma. This effect seems to be mainly related to PDT-mediated modulations of tumor vessels which improve the distribution of circulating, systemically administered chemotherapeutic macromolecular agents. However, the mechanisms involved and the optimization of this effect for therapeutic implications remain to be solved. By using the dorsal skin fold chamber method we demonstrated that both angiogenesis and microcirculation of human mesothelioma xenografts can be continuously assessed in vivo by intravital microscopy. We described a new, simple, reproducible and reliable scoring system for the assessment of tumor angiogenesis and microcirculation in this model, thereby allowing the quantitative description of the neo-vascular network development while avoiding a complicated technical setup. This method can serve as a useful tool for the assessment of novel vessel-targeted therapies against MPM. We then applied this newly established model so as to elucidate the underlying mechanisms of PDT-induced extravasation of macromolecular compounds across the endothelial barrier in tumors and surrounding normal tissue. We found that low-dose PDT selectively enhanced the uptake of macromolecular compounds in human mesothelioma xenografts compared to surrounding normal tissue. Interestingly, this increase of effective permeability of tumor vasculature was not related to the inflammatory stimuli generated by PDT such as the mobilization of leucocytes and their adhesion and penetration of the injured vessel wall. We then used the model for optimizing the drug-light conditions of low- dose PDT in order to obtain maximal leakage of the macromolecular compounds in the tumor with minimal uptake in normal surrounding tissue and we were able to identify such a therapeutic window. With these optimized PDT treatment conditions, we assessed the therapeutic effect of this new treatment concept in vivo by measuring tumor growth rates on subcutaneously grown mesothelioma xenografts in nude mice after low-dose PDT of the tumors following systemically administered liposomal (macromolecular) cisplatin, a cytostatic compound commonly used in clinical practice. We were able to demonstrate that low-dose PDT with optimized drug-light conditions combined with systemic chemotherapy indeed resulted in a reduction in tumor growth compared to chemotherapy or PDT alone. In conclusion, our work demonstrates that low-dose PDT may selectively enhance the uptake of macromolecular cytostatic drugs in superficially growing tumors such as mesotheliomas and opens new perspectives for the treatment of these diseases. - Les effets cytotoxiques de la thérapie photodynamique (PDT) sur le mésothéliome pleural malin (MPM) n'ont pas apporté de bénéfice clinique significatif. Toutefois, une application innovante non cytotoxique de la PDT serait la bienvenue en supplément des chimiothérapies pour améliorer le contrôle local de la tumeur. Le prétraitement des néovaisseaux tumoraux par une PDT à bas régime, qui améliorerait la distribution d'une chimiothérapie administrée par voie systémique de façon concomitante, a attiré une attention particulière pour de futures applications cliniques. Toutefois, les mécanismes impliqués dans cet événement et les implications thérapeutiques de ces changements physiopathologiques restent non résolus. Dans cette thèse, nous avons observé en premier que l'angiogenèse et la microcirculation dans les xénogreffes de mésothéliomes humains peuvent être observées et analysées in vivo par microscopie intravitale. Le nouveau système de score appliqué pour l'évaluation de l'angiogenèse et de la microcirculation tumorale dans cette étude est une méthode simple, reproductible et fiable servant à décrire de manière quantitative le réseau néo-vasculaire en développement, tout en évitant d'utiliser une installation technique compliquée. Ce modèle sert de nouvel outil pour l'évaluation des thérapies anti-vasculaires dirigées contre le MPM. Le modèle animal nouvellement établi a alors été utilisé pour élucider les mécanismes sous-jacents de Γ extravasation d'agents macromoléculaires induite par PDT dans les vaisseaux tumoraux et normaux. Nous avons trouvé que la PDT à fable dose améliore la distribution ciblée de drogues macromoléculaires dans des greffes de mésothéliome humain, de manière sélective pour la tumeur. La perméabilité vasculaire tumorale n'est pas influencée par les stimuli inflammatoires générés par la PDT, ce qui joue un rôle important dans la sélectivité de notre photodynamic drug delivery. Ensuite, nous avons recherché la fenêtre thérapeutique optimale de la PDT pour obtenir une accumulation sélective du colorant macromoléculaire dans le tissu tumoral ainsi qu'une efficacité de la PDT combinée avec une chimiothérapie macromoléculaire sur la croissance tumorale. Nous avons démontré que la PDT à faible dose combinée avec une administration systémique de cisplatine liposomale mène à un ralentissement de la croissance tumorale dans notre modèle de mésothéliome malin humain. En conclusion, l'utilisation de la PDT comme prétraitement pour améliorer sélectivement la distribution d'agents thérapeutiques dans des tumeurs poussant superficiellement est prometteuse. Cette observation fourni une preuve du concept remarquable et garanti la suite des investigations, éventuellement ayant pour but de développer de nouveaux concepts de thérapie pour les patients atteints de mésothéliome. Une PDT intra cavitaire à faible dose après pleuro- pneumonectomie pourrait améliorer la pénétration des agents cytostatiques administrés de façon concomitante par voie systémique dans les îlots tumoraux résiduels, et ainsi améliorer le contrôle local.
Resumo:
L’objectiu d’aquest estudi és crear un programa de prevenció de la demència a partir d’activitats i ocupacions significatives. S’utilitzarà la metodologia quantitativa i es realitzarà un estudi experimental i seqüencial. L’estudi es realitzarà al medi rural, concretament a Ripoll (Sant Bernabé). Per tal de poder obtenir la els participants per la realització de l’estudi s’utilitzarà el mostreig aleatori estratificat amb el qual s’obtindrà dos grups de 16 persones de 50 a 55 anys. Els instruments que s’utilitzaran per tal de poder obtenir les dades de l’estudi són el “Qüestionari internacional d’activitat física” (2002), la bateria neuropsicològica anomenada “Test de Barcelona abreviat” (1997), “L’escala de qualitat de vida” (2008), i per acabar s’utilitzarà el “Test KIMED” (2004). Una primera limitació pot ser que l’ajuntament no ens faciliti les dades per tal de poder realitzar el mostreig aleatori estratificat per tal de poder aconseguir la mostra. També pot ser que l’ajuntament no cedeixi el lloc per tal de poder realitzar la intervenció. Un altre possible limitació pot ser el temps atmosfèric. I per acabar també ens podem torbar amb l’abandonament del programa per part d’un o més participants.
Resumo:
Dans cette thèse, nous étudions les aspects comportementaux d'agents qui interagissent dans des systèmes de files d'attente à l'aide de modèles de simulation et de méthodologies expérimentales. Chaque période les clients doivent choisir un prestataire de servivce. L'objectif est d'analyser l'impact des décisions des clients et des prestataires sur la formation des files d'attente. Dans un premier cas nous considérons des clients ayant un certain degré d'aversion au risque. Sur la base de leur perception de l'attente moyenne et de la variabilité de cette attente, ils forment une estimation de la limite supérieure de l'attente chez chacun des prestataires. Chaque période, ils choisissent le prestataire pour lequel cette estimation est la plus basse. Nos résultats indiquent qu'il n'y a pas de relation monotone entre le degré d'aversion au risque et la performance globale. En effet, une population de clients ayant un degré d'aversion au risque intermédiaire encoure généralement une attente moyenne plus élevée qu'une population d'agents indifférents au risque ou très averses au risque. Ensuite, nous incorporons les décisions des prestataires en leur permettant d'ajuster leur capacité de service sur la base de leur perception de la fréquence moyenne d'arrivées. Les résultats montrent que le comportement des clients et les décisions des prestataires présentent une forte "dépendance au sentier". En outre, nous montrons que les décisions des prestataires font converger l'attente moyenne pondérée vers l'attente de référence du marché. Finalement, une expérience de laboratoire dans laquelle des sujets jouent le rôle de prestataire de service nous a permis de conclure que les délais d'installation et de démantèlement de capacité affectent de manière significative la performance et les décisions des sujets. En particulier, les décisions du prestataire, sont influencées par ses commandes en carnet, sa capacité de service actuellement disponible et les décisions d'ajustement de capacité qu'il a prises, mais pas encore implémentées. - Queuing is a fact of life that we witness daily. We all have had the experience of waiting in line for some reason and we also know that it is an annoying situation. As the adage says "time is money"; this is perhaps the best way of stating what queuing problems mean for customers. Human beings are not very tolerant, but they are even less so when having to wait in line for service. Banks, roads, post offices and restaurants are just some examples where people must wait for service. Studies of queuing phenomena have typically addressed the optimisation of performance measures (e.g. average waiting time, queue length and server utilisation rates) and the analysis of equilibrium solutions. The individual behaviour of the agents involved in queueing systems and their decision making process have received little attention. Although this work has been useful to improve the efficiency of many queueing systems, or to design new processes in social and physical systems, it has only provided us with a limited ability to explain the behaviour observed in many real queues. In this dissertation we differ from this traditional research by analysing how the agents involved in the system make decisions instead of focusing on optimising performance measures or analysing an equilibrium solution. This dissertation builds on and extends the framework proposed by van Ackere and Larsen (2004) and van Ackere et al. (2010). We focus on studying behavioural aspects in queueing systems and incorporate this still underdeveloped framework into the operations management field. In the first chapter of this thesis we provide a general introduction to the area, as well as an overview of the results. In Chapters 2 and 3, we use Cellular Automata (CA) to model service systems where captive interacting customers must decide each period which facility to join for service. They base this decision on their expectations of sojourn times. Each period, customers use new information (their most recent experience and that of their best performing neighbour) to form expectations of sojourn time at the different facilities. Customers update their expectations using an adaptive expectations process to combine their memory and their new information. We label "conservative" those customers who give more weight to their memory than to the xiv Summary new information. In contrast, when they give more weight to new information, we call them "reactive". In Chapter 2, we consider customers with different degree of risk-aversion who take into account uncertainty. They choose which facility to join based on an estimated upper-bound of the sojourn time which they compute using their perceptions of the average sojourn time and the level of uncertainty. We assume the same exogenous service capacity for all facilities, which remains constant throughout. We first analyse the collective behaviour generated by the customers' decisions. We show that the system achieves low weighted average sojourn times when the collective behaviour results in neighbourhoods of customers loyal to a facility and the customers are approximately equally split among all facilities. The lowest weighted average sojourn time is achieved when exactly the same number of customers patronises each facility, implying that they do not wish to switch facility. In this case, the system has achieved the Nash equilibrium. We show that there is a non-monotonic relationship between the degree of risk-aversion and system performance. Customers with an intermediate degree of riskaversion typically achieve higher sojourn times; in particular they rarely achieve the Nash equilibrium. Risk-neutral customers have the highest probability of achieving the Nash Equilibrium. Chapter 3 considers a service system similar to the previous one but with risk-neutral customers, and relaxes the assumption of exogenous service rates. In this sense, we model a queueing system with endogenous service rates by enabling managers to adjust the service capacity of the facilities. We assume that managers do so based on their perceptions of the arrival rates and use the same principle of adaptive expectations to model these perceptions. We consider service systems in which the managers' decisions take time to be implemented. Managers are characterised by a profile which is determined by the speed at which they update their perceptions, the speed at which they take decisions, and how coherent they are when accounting for their previous decisions still to be implemented when taking their next decision. We find that the managers' decisions exhibit a strong path-dependence: owing to the initial conditions of the model, the facilities of managers with identical profiles can evolve completely differently. In some cases the system becomes "locked-in" into a monopoly or duopoly situation. The competition between managers causes the weighted average sojourn time of the system to converge to the exogenous benchmark value which they use to estimate their desired capacity. Concerning the managers' profile, we found that the more conservative Summary xv a manager is regarding new information, the larger the market share his facility achieves. Additionally, the faster he takes decisions, the higher the probability that he achieves a monopoly position. In Chapter 4 we consider a one-server queueing system with non-captive customers. We carry out an experiment aimed at analysing the way human subjects, taking on the role of the manager, take decisions in a laboratory regarding the capacity of a service facility. We adapt the model proposed by van Ackere et al (2010). This model relaxes the assumption of a captive market and allows current customers to decide whether or not to use the facility. Additionally the facility also has potential customers who currently do not patronise it, but might consider doing so in the future. We identify three groups of subjects whose decisions cause similar behavioural patterns. These groups are labelled: gradual investors, lumpy investors, and random investor. Using an autocorrelation analysis of the subjects' decisions, we illustrate that these decisions are positively correlated to the decisions taken one period early. Subsequently we formulate a heuristic to model the decision rule considered by subjects in the laboratory. We found that this decision rule fits very well for those subjects who gradually adjust capacity, but it does not capture the behaviour of the subjects of the other two groups. In Chapter 5 we summarise the results and provide suggestions for further work. Our main contribution is the use of simulation and experimental methodologies to explain the collective behaviour generated by customers' and managers' decisions in queueing systems as well as the analysis of the individual behaviour of these agents. In this way, we differ from the typical literature related to queueing systems which focuses on optimising performance measures and the analysis of equilibrium solutions. Our work can be seen as a first step towards understanding the interaction between customer behaviour and the capacity adjustment process in queueing systems. This framework is still in its early stages and accordingly there is a large potential for further work that spans several research topics. Interesting extensions to this work include incorporating other characteristics of queueing systems which affect the customers' experience (e.g. balking, reneging and jockeying); providing customers and managers with additional information to take their decisions (e.g. service price, quality, customers' profile); analysing different decision rules and studying other characteristics which determine the profile of customers and managers.
Resumo:
Remote monitoring through the use of cameras is widely utilized for traffic operation, but has not been utilized widely for roadway maintenance operations. The Utah Department of Transportation (UDOT) has implemented a new remote monitoring system, referred to as a Cloud-enabled Remote Video Streaming (CRVS) camera system for snow removal-related maintenance operations in the winter. The purpose of this study was to evaluate the effectiveness of the use of the CRVS camera system in snow removal-related maintenance operations. This study was conducted in two parts: opinion surveys of maintenance station supervisors and an analysis on snow removal-related maintenance costs. The responses to the opinion surveys mostly displayed positive reviews of the use of the CRVS cameras. On a scale of 1 (least effective) to 5 (most effective), the average overall effectiveness given by the station supervisors was 4.3. An expedition trip for this study was defined as a trip that was made to just check the roadways if snow-removal was necessary. The average of the responses received from surveys was calculated to be a 33 percent reduction in expedition trips. For the second part of this study, an analysis was performed on the snow removal-related maintenance cost data provided by UDOT to see if the installation of a CRVS camera had an effect in reducing expedition trips. This expedition cost comparison was performed for 10 sets of maintenance stations within Utah. It was difficult to make any definitive inferences from the comparison of expedition costs over the years for which precipitation and expedition cost data were available; hence a statistical analysis was performed using the Mixed Model ANOVA. This analysis resulted in an average of 14 percent higher ratio of expedition costs at maintenance stations with a CRVS camera before the installation of the camera compared to the ratio of expedition costs after the installation of the camera. This difference was not proven to be statistically significant at the 95 percent confident level, but indicated that the installation of CRVS cameras was on the average helpful in reducing expedition costs and may be considered practically significant. It is recommended that more detailed and consistent maintenance cost records be prepared for accurate analysis of cost records for this type of study in the future.
Resumo:
Red light running continues to be a serious safety concern for many communities in the United States. The Federal Highway Administration reported that in 2011, red light running accounted for 676 fatalities nationwide. Red light running crashes at a signalized intersections are more serious, especially in high speed corridors where speeds are above 35 mph. Many communities have invested in red light countermeasures including low-cost strategies (e.g. signal backplates, targeted enforcement, signal timing adjustments and improvement with signage) to high-cost strategies (e.g. automated enforcement and intersection geometric improvements). This research study investigated intersection confirmation lights as a low-cost strategy to reduce red light running violations. Two intersections in Altoona and Waterloo, Iowa were equipped with confirmation lights which targeted the through and left turning movements. Confirmation lights enable a single police officer to monitor a specific lane of traffic downstream of the intersection. A before-after analysis was conducted in which a change in red light running violations prior to- and 1 and 3 months after installation were evaluated. A test of proportions was used to determine if the change in red light running violation rates were statistically significant at the 90 and 95 percent levels of confidence. The two treatment intersections were then compared to the changes of red light running violation rates at spillover intersections (directly adjacent to the treatment intersections) and control intersections. The results of the analysis indicated a 10 percent reduction of red light running violations in Altoona and a 299 percent increase in Waterloo at the treatment locations. Finally, the research team investigated the time into red for each observed red light running violation. The analysis indicated that many of the violations occurred less than one second into the red phase and that most of the violation occurred during or shortly after the all-red phase.
Resumo:
Single-vehicle run-off-road crashes are the most common crash type on rural two-lane Iowa roads. Rumble strips have been proven effective in mitigating these crashes, but these strips are commonly installed in paved shoulders adjacent to higher-volume roads owned by the State of Iowa. Lower-volume paved rural roads owned by local agencies do not commonly feature paved shoulders but frequently experience run-off-road crashes. This project involved installing “rumble stripes,” which are a combination of conventional rumble strips with a painted edge line placed on the surface of the milled area, along the edge of the travel lanes but at a narrow width to avoid possible intrusion into the normal vehicle travel paths. Candidate locations were selected from a list of paved local rural roads that were most recently listed in the top 5% of roads for run-off-road crashes in Iowa. Horizontal curves were the most favored locations for rumble stripe installation because they commonly experience roadway departure crashes. The research described in this report was part of a project funded by the Federal Highway Administration, Iowa Highway Research Board, and Iowa Department of Transportation to evaluate the effectiveness of edge line rumble strips in Iowa. The project evaluated the effectiveness of “rumble stripes” in reducing run-off-road crashes and in improving the longevity and wet weather visibility of edge line markings. This project consists of two phases. The first phase was to select pilot study locations, select a set of test sites, install rumble stripes, summarize lessons learned during installation, and provide a preliminary assessment of the rumble stripes’ performance. This information is summarized in this report. The purpose of the second phase is to provide a more long-term assessment of the performance of the pavement markings, conduct preliminary crash assessments, and evaluate lane keeping. This will result in a forthcoming second report.
Resumo:
La Universitat de Vic disposa, entre altres equips, d’una cèl·lula flexible de fabricació, del fabricant Festo, que simula un procés de formació de palets amb els productes que es disposen en un magatzem intermedi. Aquesta cèl·lula està composta de quatre estacions de muntatge diferenciades (càrrega de palets, càrrega de plaques, magatzem intermedi i transport). Cada una disposa d'un PLC SIEMENS S7-300 per la seva automatització, i tots aquests es troben interconnectats amb una xarxa industrial Profibus. L'objectiu d'aquest projecte és implantar el sistema SCADA Vijeo Citect pel control i supervisió de l'estació magatzem d'aquesta cèl·lula flexible de fabricació, establint també un intercanvi de dades entre l'SCADA i el Microsoft Access, per poder ser utilitzat per la docència. Aquest projecte s'ha desenvolupat en cinc fases diferents: 1. La primera fase s'ha dedicat a l'automatització pròpiament de l'estació magatzem a partir de l'autòmat programable Siemens S7-300 i complint amb les necessitats plantejades. 2. En la segona fase s'ha programat i establert la comunicació per l'intercanvi de dades (lectura i escriptura) entre el sistema SCADA Vijeo Citect i la base de dades de Microsoft Access. 3. En la tercera fase s'ha elaborat i programat l'entorn gràfic de supervisió i control del procés a partir del sistema SCADA Vijeo Citect. 4. En la quarta fase s'ha instal·lat un OPC Server en el PC i s'ha establert la comunicació entre el PLC i el sistema SCADA. 5. Finalment s'ha anat revisant i depurant les diferents programacions i comunicacions per tal de que el sistema funcioni com a un conjunt.
Resumo:
Avui en dia s’ha convertit en una necessitat tenir cura del medi ambient i optimitzar els recursos naturals. En el camp per estalviar energia s’han fet grans progressos i disposem d’un gran ventall de dispositius que ens ajuden i ens faciliten l’optimització del consum d’energia. Però és una realitat que en l’estalvi del consum d’aigua el progrés ha estat molt menor i es limita molt a donar consells i repartir dosificadors d’aigua. Qui no ha vist carrers o jardins o cases inundades amb milers de litres d’aigua? Aquesta realitat m’ha portat a dissenyar i desenvolupar un prototip que em permeti tenir un millor control del consum d’aigua. El prototip, a trets principals, consta d’un sensor, una electrovàlvula i una placa Arduino Atmega. El sensor ens permet mesurar els litres consumits durant un cert període de temps. Passat aquest temps de mostreig es compara els litres consumits amb el consum habitual, en aquell període de temps. En cas de sobrepassar el volum programat es tancarà l’electrovàlvula de forma automàtica i rebrem un SMS al telèfon. L’activació de l’alarma es pot ajustar que sigui al igualar-se els dos valors, litres programats i litres consumits. També es pot programar el percentatge que cal sobrepassar de litres consumits per activar l’alarma, com el temps de mostreig. El fet de poder programar tots aquests valors ens permet fer un ajust ideal per a la instal·lació que es vol tenir controlada. A més, el prototip es pot utilitzar per enviar a la companyia d’aigua el valor del comptador de forma automàtica. D’aquesta forma la companyia d’aigua també optimitza recursos estalviant-se el desplaçament de personal a la instal·lació per fer la lectura corresponent. El prototip està basat amb un Arduino Atmega que ens permet el processament de les dades programades i capturades pel sensor. També s’ha incorporat una pantalla TFT Touch 2’8”, que permet visualitzar i programar els valors d’una forma molt més intuïtiva. Per enviar els SMS s’utilitza una placa d’Arduino Cel·lular Shield - SM5100B, a la qual només cal afegir una targeta SIM. A priori, el prototip té un elevat cost al fabricar una sola unitat i pot semblar poc útil. Però ens pot estalviar alguna sorpresa en les factures d’aigua si tenim una fuita i no ens n’adonem fins a veure el rebut de la companyia. Si es fabriqués a grans quantitats es podria abaratir el preu i fer-lo encara més engrescador.
Resumo:
In 1982, Iowa's crossing warning identification system and signage at rail crossings were outdated, inconsistent and inadequate. Iowa's railroad system had been reduced and reorganized during the 1970's and many of the surviving railroad companies were unable to install new signs or devote staff to updating information. The preliminary engineering part of this project improved the information inventory about each crossing, provided for installation of identification tags and resulted in a comprehensive list of posts and signs eligible for replacement. The sign installation portion of this project resulted in erection of nearly 10,000 new crossbuck signs and 10,000 advance warning signs with high intensity reflectorization. In addition, new posts and multiple track signs were replaced where appropriate. Increased visibility of crossings for the motoring public has resulted from proper sign placement and use of high intensity reflectorization. The tagging has provided a consistent correct identification of crossings for accident reporting. The computer inventory of information about the crossings is now correct and provides for informed decision making to administrators of Federal and State crossing safety funds.
Resumo:
Questionnaires were sent to transportation agencies in all 50 states in the U.S., to Puerto Rico, and all provinces in Canada asking about their experiences with uplift problems of - corrugated metal pipe (CMP). Responses were received from 52 agencies who reported 9 failures within the last 5 years. Some agencies also provided design standards for tiedowns to resist uplift. There was a wide variety in restraining forces used; for example for a pipe 6 feet in diameter, the resisting force ranged from 10 kips to 66 kips. These responses verified the earlier conclusion based on responses from Iowa county engineers that a potential uplift danger exists.when end restraint is not provided for CMP and that existing designs have an unclear theoretical or experimental basis. In an effort to develop more rational design standards, the longitudinal stiffness of three CMP ranging from 4 to 8 feet in diameter were measured in the laboratory. Because only three tests were conducted, a theoretical model to evaluate the stiffness of pipes of a variety of gages and corrugation geometries was also developed. The experimental results indicated a "stiffness" EI in the range of 9.11 x 10^5 k-in^2 to 34.43 x 10^5 k-in^2 for the three pipes with the larger diameter pipes having greater stiffness. The theoretical model developed conservatively estimates these stiffnesses.
Resumo:
This investigation is the final phase of a three part study whose overall objectives were to determine if a restraining force is required to prevent inlet uplift failures in corrugated metal pipe (CMP) installations, and to develop a procedure for calculating the required force when restraint is required. In the initial phase of the study (HR-306), the extent of the uplift problem in Iowa was determined and the forces acting on a CMP were quantified. In the second phase of the study (HR- 332), laboratory and field tests were conducted. Laboratory tests measured the longitudinal stiffness ofCMP and a full scale field test on a 3.05 m (10 ft) diameter CMP with 0.612 m (2 ft) of cover determined the soil-structure interaction in response to uplift forces. Reported herein are the tasks that were completed in the final phase of the study. In this phase, a buried 2.44 m (8 ft) CMP was tested with and without end-restraint and with various configurations of soil at the inlet end of the pipe. A total of four different soil configurations were tested; in all tests the soil cover was constant at 0.61 m (2 ft). Data from these tests were used to verify the finite element analysis model (FEA) that was developed in this phase of the research. Both experiments and analyses indicate that the primary soil contribution to uplift resistance occurs in the foreslope and that depth of soil cover does not affect the required tiedown force. Using the FEA, design charts were developed with which engineers can determine for a given situation if restraint force is required to prevent an uplift failure. If an engineer determines restraint is needed, the design charts provide the magnitude of the required force. The design charts are applicable to six gages of CMP for four flow conditions and two types of soil.
Resumo:
It is generally accepted that high density polyethylene pipe (HDPE) performs well under live loads with shallow cover, provided the backfill is well compacted. Although industry standards require carefully compacted backfill, poor inspection and/or faulty construction may result in soils that provide inadequate restraint at the springlines of the pipes thereby causing failure. The objectives of this study were: 1) to experimentally define a lower limit of compaction under which the pipes perform satisfactorily, 2) to quantify the increase in soil support as compaction effort increases, 3) to evaluate pipe response for loads applied near the ends of the buried pipes, 4) to determine minimum depths of cover for a variety of pipes and soil conditions by analytically expanding the experimental results through the use of the finite element program CANDE. The test procedures used here are conservative especially for low-density fills loaded to high contact stresses. The failures observed in these tests were the combined effect of soil bearing capacity at the soil surface and localized wall bending of the pipes. Under a pavement system, the pipes' performance would be expected to be considerably better. With those caveats, the following conclusions are drawn from this study. Glacial till compacted to 50% and 80% provides insufficient support; pipe failureoccurs at surface contact stresses lower than those induced by highway trucks. On the other hand, sand backfill compacted to more than 110 pcf (17.3 kN/m3) is satisfactory. The failure mode for all pipes with all backfills is localized wall bending. At moderate tire pressures, i.e. contact stresses, deflections are reduced significantly when backfill density is increased from about 50 pcf (7.9 kN/m^3) to 90 pcf (14.1 kN/m^3). Above that unit weight, little improvement in the soil-pipe system is observed. Although pipe stiffness may vary as much as 16%, analyses show that backfill density is more important than pipe stiffness in controlling both deflections at low pipe stresses and at the ultimate capacity of the soil-pipe system. The rate of increase in ultimate strength of the system increases nearly linearly with increasing backfill density. When loads equivalent to moderate tire pressures are applied near the ends of the pipes, pipe deflections are slighly higher than when loaded at the center. Except for low density glacial till, the deflections near the ends are not excessive and the pipes perform satisfactorily. For contact stresses near the upper limit of truck tire pressures and when loaded near the end, pipes fail with localized wall bending. For flowable fill backfill, the ultimate capacity of the pipes is nearly doubled and at the upper limit of highway truck tire pressures, deflections are negligible. All pipe specimens tested at ambient laboratory room temperatures satisfied AASHTO minimum pipe stiffness requirements at 5% deflection. However, nearly all specimens tested at elevated pipe surface temperatures, approximately 122°F (50°C), failed to meet these requirements. Some HDPE pipe installations may not meet AASHTO minimum pipe stiffness requirements when installed in the summer months (i.e. if pipe surface temperatures are allowed to attain temperatures similar to those tested here). Heating of any portion of the pipe circumference reduced the load carrying capacity of specimens. The minimum soil cover depths, determined from the CANOE analysis, are controlled by the 5% deflection criterion. The minimum soil cover height is 12 in. (305 mm). Pipes with the poor silt and clay backfills with less than 85% compaction require a minimum soil cover height of 24 in. (610 mm). For the sand at 80% compaction, the A36 HDPE pipe with the lowest moment of inertia requires a minimum of 24 in. (610 mm) soil cover. The C48 HDPE pipe with the largest moment of inertia and all other pipes require a 12 in. (305 mm) minimum soil cover.
Resumo:
In the past, culvert pipes were made only of corrugated metal or reinforced concrete. In recent years, several manufacturers have made pipe of lightweight plastic - for example, high density polyethylene (HDPE) - which is considered to be viscoelastic in its structural behavior. It appears that there are several highway applications in which HDPE pipe would be an economically favorable alternative. However, the newness of plastic pipe requires the evaluation of its performance, integrity, and durability; A review of the Iowa Department of Transportation Standard Specifications for Highway and Bridge Construction reveals limited information on the use of plastic pipe for state projects. The objective of this study was to review and evaluate the use of HDPE pipe in roadway applications. Structural performance, soil-structure interaction, and the sensitivity of the pipe to installation was investigated. Comprehensive computerized literature searches were undertaken to define the state-of-the-art in the design and use of HDPE pipe in highway applications. A questionnaire was developed and sent to all Iowa county engineers to learn of their use of HDPE pipe. Responses indicated that the majority of county engineers were aware of the product but were not confident in its ability to perform as well as conventional materials. Counties currently using HDPE pipe in general only use it in driveway crossings. Originally, we intended to survey states as to their usage of HDPE pipe. However, a few weeks after initiation of the project, it was learned that the Tennessee DOT was in the process of making a similar survey of state DOT's. Results of the Tennessee survey of states have been obtained and included in this report. In an effort to develop more confidence in the pipe's performance parameters, this research included laboratory tests to determine the ring and flexural stiffness of HDPE pipe provided by various manufacturers. Parallel plate tests verified all specimens were in compliance with ASTM specifications. Flexural testing revealed that pipe profile had a significant effect on the longitudinal stiffness and that strength could not be accurately predicted on the basis of diameter alone. Realizing that the soil around a buried HDPE pipe contributes to the pipe stiffness, the research team completed a limited series of tests on buried 3 ft-diameter HDPE pipe. The tests simulated the effects of truck wheel loads above the pipe and were conducted with two feet of cover. These tests indicated that the type and quality of backfill significantly influences the performance of HDPE pipe. The tests revealed that the soil envelope does significantly affect the performance of HDPE pipe in situ, and after a certain point, no additional strength is realized by increasing the quality of the backfill.
Resumo:
Innovative Rail Ltd. of Cedar Rapids, Iowa produced a new rail/highway crossing gate arm that shows promise in two areas: a. Minimizing arm breakage, and b. Added target value to motorists. The new gate was demonstrated to the Chicago and North Western Transportation Company, and that railroad has requested its use at two crossings on an "experimental basis" to determine if its installation provides relief in those areas. On April 18, 1986, the Department observed a test of the material under field conditions with the Transportation Company. The gate received four mid-center strikes at 5 MPH by a company truck while in the lowered position, and showed no damage. In a fifth mid-center strike at 15 MPH, the gate was visibly damaged at the connection to its raising mechanism, but continued to function though at a 5-10 degree drop. Several pictures of the gate and its saddle mechanism are shown in Appendix A of this report. Innovative Rail established distributorships in the United States and Canada, and has since gone out of business.