847 resultados para reserve requirements
Resumo:
Objective To perform systematic assessment of ovarian reserve markers using a combination of tests in juvenile systemic lupus erythematosus (JSLE) patients without amenorrhoea. Methods Twenty-seven consecutive JSLE female patients and 13 healthy controls without amenorrhoea were evaluated for 6 months. Ovarian reserve was assessed during early follicular phase by serum levels of follicle stimulating hormone (FSH), luteinising hormone (LH), estradiol, inhibin A, inhibin B and anti-Mullerian hormone (AMH). Ovarian size was measured by abdominal ultrasonography. Demographic data, disease activity, damage and treatment were also analysed. Results The median of current age was similar in ISLE patients and controls (16.5 vs. 15years, p=0.31) with a significantly higher age at menarche (13 vs. 12years, p=0.03). A trend of lower median total antral follicle count was observed in JSLE compared to controls (9 vs. 14.5, p=0.062) with similar median of other ovarian reserve parameters (p>0.05). Further evaluation of patients treated with cyclophosphamide and those without this treatment revealed a higher median FSH levels (6.4 vs. 4.6 IU/L, p=0.023). Inhibin B, AMH levels and ovarian volume were also lower but did not reach statistical significance (10.8 vs. 27.6 pg/mL, p=0.175; 0.6 vs. 1.5 ng/mL, p=0.276; 3.4 vs. 5 cm(3), p=0.133; respectively). LH (2.7 vs. 2.9 IU/L, p=0.43), estradiol (50 vs. 38 pg/mL, p=0.337) and inhibin A (1.1 vs. 0 pg/mL, p=0.489) levels were comparable in both groups. Conclusions Our study suggests that ovarian reserve after cyclophosphamide treatment may be hampered in spite of the presence of menstrual cycles emphasising the relevance of gonadal protection during the use of this alkylating agent.
Resumo:
Abstract Background In patients with advanced non-ischemic cardiomyopathy (NIC), right-sided cardiac disturbances has prognostic implications. Right coronary artery (RCA) flow pattern and flow reserve (CFR) are not well known in this setting. The purpose of this study was to assess, in human advanced NIC, the RCA phasic flow pattern and CFR, also under right-sided cardiac disturbances, and compare with left coronary circulation. As well as to investigate any correlation between the cardiac structural, mechanical and hemodynamic parameters with RCA phasic flow pattern or CFR. Methods Twenty four patients with dilated severe NIC were evaluated non-invasively, even by echocardiography, and also by cardiac catheterization, inclusive with Swan-Ganz catheter. Intracoronary Doppler (Flowire) data was obtained in RCA and left anterior descendent coronary artery (LAD) before and after adenosine. Resting RCA phasic pattern (diastolic/systolic) was compared between subgroups with and without pulmonary hypertension, and with and without right ventricular (RV) dysfunction; and also with LAD. RCA-CFR was compared with LAD, as well as in those subgroups. Pearson's correlation analysis was accomplished among echocardiographic (including LV fractional shortening, mass index, end systolic wall stress) more hemodynamic parameters with RCA phasic flow pattern or RCA-CFR. Results LV fractional shortening and end diastolic diameter were 15.3 ± 3.5 % and 69.4 ± 12.2 mm. Resting RCA phasic pattern had no difference comparing subgroups with vs. without pulmonary hypertension (1.45 vs. 1.29, p = NS) either with vs. without RV dysfunction (1.47 vs. 1.23, p = NS); RCA vs. LAD was 1.35 vs. 2.85 (p < 0.001). It had no significant correlation among any cardiac mechanical or hemodynamic parameter with RCA-CFR or RCA flow pattern. RCA-CFR had no difference compared with LAD (3.38 vs. 3.34, p = NS), as well as in pulmonary hypertension (3.09 vs. 3.10, p = NS) either in RV dysfunction (3.06 vs. 3.22, p = NS) subgroups. Conclusion In patients with chronic advanced NIC, RCA phasic flow pattern has a mild diastolic predominance, less marked than in LAD, with no effects from pulmonary artery hypertension or RV dysfunction. There is no significant correlation between any cardiac mechanical-structural or hemodynamic parameter with RCA-CFR or RCA phasic flow pattern. RCA flow reserve is still similar to LAD, independently of those right-sided cardiac disturbances.
Resumo:
Chlorophyll determination with a portable chlorophyll meter can indicate the period of highest N demand of plants and whether sidedressing is required or not. In this sense, defining the optimal timing of N application to common bean is fundamental to increase N use efficiency, increase yields and reduce the cost of fertilization. The objectives of this study were to evaluate the efficiency of N sufficiency index (NSI) calculated based on the relative chlorophyll index (RCI) in leaves, measured with a portable chlorophyll meter, as an indicator of time of N sidedressing fertilization and to verify which NSI (90 and 95 %) value is the most appropriate to indicate the moment of N fertilization of common bean cultivar Perola. The experiment was carried out in the rainy and dry growing seasons of the agricultural year 2009/10 on a dystroferric Red Nitosol, in Botucatu, São Paulo State, Brazil. The experiment was arranged in a randomized complete block design with five treatments, consisting of N managements (M1: 200 kg ha-1 N (40 kg at sowing + 80 kg 15 days after emergence (DAE) + 80 kg 30 DAE); M2: 100 kg ha-1 N (20 kg at sowing + 40 kg 15 DAE + 40 kg 30 DAE); M3: 20 kg ha-1 N at sowing + 30 kg ha-1 when chlorophyll meter readings indicated NSI < 95 %; M4: 20 kg ha-1 N at sowing + 30 kg ha-1 N when chlorophyll meter readings indicated NSI < 90 % and, M5: control (without N application)) and four replications. The variables RCI, aboveground dry matter, total leaf N concentration, production components, grain yield, relative yield, and N use efficiency were evaluated. The RCI correlated with leaf N concentrations. By monitoring the RCI with the chlorophyll meter, the period of N sidedressing of common bean could be defined, improving N use efficiency and avoiding unnecessary N supply to common bean. The NSI 90 % of the reference area was more efficient to define the moment of N sidedressing of common bean, to increase N use efficiency.
Resumo:
Skeletal muscle is the major deposit of protein molecules. As for any cell or tissue, total muscle protein reflects a dynamic turnover between net protein synthesis and degradation. Noninvasive and invasive techniques have been applied to determine amino acid catabolism and muscle protein building at rest, during exercise and during the recovery period after a single experiment or training sessions. Stable isotopic tracers (13C-lysine, 15N-glycine, ²H5-phenylalanine) and arteriovenous differences have been used in studies of skeletal muscle and collagen tissues under resting and exercise conditions. There are different fractional synthesis rates in skeletal muscle and tendon tissues, but there is no major difference between collagen and myofibrillar protein synthesis. Strenuous exercise provokes increased proteolysis and decreased protein synthesis, the opposite occurring during the recovery period. Individuals who exercise respond differently when resistance and endurance types of contractions are compared. Endurance exercise induces a greater oxidative capacity (enzymes) compared to resistance exercise, which induces fiber hypertrophy (myofibrils). Nitrogen balance (difference between protein intake and protein degradation) for athletes is usually balanced when the intake of protein reaches 1.2 g·kg-1·day-1 compared to 0.8 g·kg-1·day-1 in resting individuals. Muscular activities promote a cascade of signals leading to the stimulation of eukaryotic initiation of myofibrillar protein synthesis. As suggested in several publications, a bolus of 15-20 g protein (from skimmed milk or whey proteins) and carbohydrate (± 30 g maltodextrine) drinks is needed immediately after stopping exercise to stimulate muscle protein and tendon collagen turnover within 1 h.
Resumo:
Communication and coordination are two key-aspects in open distributed agent system, being both responsible for the system’s behaviour integrity. An infrastructure capable to handling these issues, like TuCSoN, should to be able to exploit modern technologies and tools provided by fast software engineering contexts. Thesis aims to demonstrate TuCSoN infrastructure’s abilities to cope new possibilities, hardware and software, offered by mobile technology. The scenarios are going to configure, are related to the distributed nature of multi-agent systems where an agent should be located and runned just on a mobile device. We deal new mobile technology frontiers concerned with smartphones using Android operating system by Google. Analysis and deployment of a distributed agent-based system so described go first to impact with quality and quantity considerations about available resources. Engineering issue at the base of our research is to use TuCSoN against to reduced memory and computing capability of a smartphone, without the loss of functionality, efficiency and integrity for the infrastructure. Thesis work is organized on two fronts simultaneously: the former is the rationalization process of the available hardware and software resources, the latter, totally orthogonal, is the adaptation and optimization process about TuCSoN architecture for an ad-hoc client side release.
Resumo:
EUMETSAT (www.eumetsat.int) e’ l’agenzia europea per operazioni su satelliti per monitorare clima, meteo e ambiente terrestre. Dal centro operativo situato a Darmstadt (Germania), si controllano satelliti meteorologici su orbite geostazionarie e polari che raccolgono dati per l’osservazione dell’atmosfera, degli oceani e della superficie terrestre per un servizio continuo di 24/7. Un sistema di monitoraggio centralizzato per programmi diversi all’interno dell’ambiente operazionale di EUMETSAT, e’ dato da GEMS (Generic Event Monitoring System). Il software garantisce il controllo di diverse piattaforme, cross-monitoring di diverse sezioni operative, ed ha le caratteristiche per potere essere esteso a future missioni. L’attuale versione della GEMS MMI (Multi Media Interface), v. 3.6, utilizza standard Java Server Pages (JSP) e fa uso pesante di codici Java; utilizza inoltre files ASCII per filtri e display dei dati. Conseguenza diretta e’ ad esempio, il fatto che le informazioni non sono automaticamente aggiornate, ma hanno bisogno di ricaricare la pagina. Ulteriori inputs per una nuova versione della GEMS MMI vengono da diversi comportamenti anomali riportati durante l’uso quotidiano del software. La tesi si concentra sulla definizione di nuovi requisiti per una nuova versione della GEMS MMI (v. 4.4) da parte della divisione ingegneristica e di manutenzione di operazioni di EUMETSAT. Per le attivita’ di supporto, i test sono stati condotti presso Solenix. Il nuovo software permettera’ una migliore applicazione web, con tempi di risposta piu’ rapidi, aggiornamento delle informazioni automatico, utilizzo totale del database di GEMS e le capacita’ di filtri, insieme ad applicazioni per telefoni cellulari per il supporto delle attivita’ di reperibilita’. La nuova versione di GEMS avra’ una nuova Graphical User Interface (GUI) che utilizza tecnologie moderne. Per un ambiente di operazioni come e’ quello di EUMETSAT, dove l’affidabilita’ delle tecnologie e la longevita’ dell’approccio scelto sono di vitale importanza, non tutti gli attuali strumenti a disposizione sono adatti e hanno bisogno di essere migliorati. Allo stesso tempo, un’ interfaccia moderna, in termini di visual design, interattivita’ e funzionalita’, e’ importante per la nuova GEMS MMI.
Night Vision Imaging System (NVIS) certification requirements analysis of an Airbus Helicopters H135
Resumo:
The safe operation of nighttime flight missions would be enhanced using Night Vision Imaging Systems (NVIS) equipment. This has been clear to the military since 1970s and to the civil helicopters since 1990s. In these last months, even Italian Emergency Medical Service (EMS) operators require Night Vision Goggles (NVG) devices that therefore amplify the ambient light. In order to fly with this technology, helicopters have to be NVIS-approved. The author have supported a company, to quantify the potentiality of undertaking the certification activity, through a feasibility study. Even before, NVG description and working principles have been done, then specifications analysis about the processes to make a helicopter NVIS-approved has been addressed. The noteworthy difference between military specifications and the civilian ones highlights non-irrevelant lacks in the latter. The activity of NVIS certification could be a good investment because the following targets have been achieved: Reductions of the certification cost, of the operating time and of the number of non-compliance.