993 resultados para quantum well electrodes
Resumo:
Results of experiments recently performed are reported, in which two optical parametric amplifiers were set up to generate two independently quadrature squeezed continuous wave laser beams. The transformation of quadrature squeezed states into polarization squeezed states and into states with spatial quantum correlations is demonstrated. By utilizing two squeezed laser beams, a polarization squeezed state exhibiting three simultaneously squeezed Stokes operator variances was generated. Continuous variable polarization entanglement was generated and the Einstein-Podolsky-Rosen paradox was observed. A pair of Stokes operators satisfied both the inseparability criterion and the conditional variance criterion. Values of 0.49 and 0.77, respectively, were observed, with entanglement requiring values below unity. The inseparability measure of the observed quadrature entanglement was 0.44. This value is sufficient for a demonstration of quantum teleportation, which is the next experimental goal of the authors.
Resumo:
We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump pump, Stokes signal, and Raman coherence idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions.
Resumo:
We introduce a refinement of the standard continuous variable teleportation measurement and displacement strategies. This refinement makes use of prior knowledge about the target state and the partial information carried by the classical channel when entanglement is nonmaximal. This gives an improvement in the output quality of the protocol. The strategies we introduce could be used in current continuous variable teleportation experiments.
Resumo:
We investigate coherent electron transport through a parallel circuit of two quantum dots (QDs), each of which has a single tunable. energy level. Electrons tunnelling via each dot from the left lead interfere with each other at the right lead. It is shown that due to the quantum interference of tunnelling electrons the double QD device is magnetically polarized by coherent circulation of electrons on the closed path through the dots and the leads. By varying the energy level of each dot one can make the magnetic states of the device be up-, non- or down-polarized. It is shown that for experimentally accessible temperatures and applied biases the magnetic polarization currents Should be sufficiently large to observe with current nanotechnology.
Resumo:
Os ataques de pânico (AP) podem ser precipitados pela inalação de dióxido de carbono (CO2 5%) ou pela infusão de lactato de sódio 0,5 mol/L (LAC) em pacientes predispostos, mas não nos indivíduos sadios ou pacientes com outros transtornos psiquiátricos. Estas e outras observações sugeriram que os AP sejam "alarmes falsos de sufocamento". O TP também caracteriza-se pela alta comorbidade com ansiedade de separação da infância (ASI). De fato, a ASI tem sido considerada como um fator predisponente tanto do pânico como da resistência aos panicolíticos. Estudos pré-clínicos do nosso laboratório mostraram, por outro lado, que a fluoxetina (FLX) atenua o pânico experimental à estimulação elétrica da matéria cinzenta periaquedutal dorsal (MCPAd) e à injeção de cianeto de potássio (KCN) em doses e regimes similares aos empregados na clínica. Adicionalmente, estes estudos mostraram que o isolamento social neonatal (ISN), um modelo de ASI, abole os efeitos panicolíticos da fluoxetina (1-2 mg.kg-1.dia-1, 21 dias) no modelo de pânico por estimulação da MCPAd. Portanto, o presente trabalho avaliou os efeitos da administração de 4 mg/kg de FLX (Estudo-1) e da infusão de uma solução 0,5 mol/L de LAC (Estudo-2) sobre as respostas de pânico à estimulação da MCPAd ou à injeção de KCN, respectivamente, em ratos submetidos ao isolamento social neonatal tanto efetivo (ISN) quanto fictício (ISF). No Estudo-1, ratos Wistar machos adultos submetidos ao ISN (3 h diárias) ou ao ISF (somente manipulação), ao longo da lactação, foram implantados com eletrodos na MCPAd e tratados com salina (0,9%, SAL) ou FLX (4 mg.kg-1.dia-1) ao longo de 21 dias. Nos ratos tratados com SAL, enquanto os limiares das respostas de pânico mantiveram-se praticamente inalterados no grupo ISF, eles foram progressivamente aumentados no grupo ISN. Os ratos tratados com FLX4 apresentaram limiares mais elevados que aqueles dos ratos tratados com SAL. A comparação aos limiares basais mostrou que a FLX4 teve efeitos diferenciados nos grupos ISF e ISN, aumentando ou reduzindo seus limiares, respectivamente. Embora não tenhamos observado diferenças dos efeitos da FLX4 sobre os limiares de pânico dos grupos ISN e ISF, as variações percentuais em relação à sessão de triagem indicam que a FLX4 teve efeitos até mesmo facilitadores. Estes resultados estendem observações anteriores da ausência de efeitos de doses menores de FLX nos ratos submetidos ao ISN. Por sua vez, o Estudo-2 mostrou que a infusão endovenosa de uma concentração clinicamente eficaz de LAC (0,5 mol/L) não tem efeito algum sobre o pânico induzido pelo KCN em ratos tanto virgens quanto submetidos ao ISF ou ISN. Embora os últimos resultados sugiram que os AP ao KCN (em ratos) e LAC (em humanos) envolvam mecanismos distintos, a conclusão definitiva requer experimentos adicionais com concentrações maiores de LAC.
Resumo:
The ability to monitor fetal heart rate is vital during late pregnancy and labor in order to evaluate fetal well-being. Current monitoring practice is essentially based on external cardiotocography and, less frequently, during labor, invasive fetal scalp electrocardiography. Many current and envisaged applications could benefi t from simpler devices using a 3-lead ECG confi guration. We are designing a maternity support belt with an embedded wireless 3-lead ECG sensor, and have investigated the infl uence of the ground electrode position on signal quality. Data from over 100 pregnant women was collected with the ground electrode placed in 3 locations in order to determine optimum electrode placement and belt form factor.
Resumo:
1 – Summary of the decision taken by the Portuguese Constitutional Court, of January 13, 2011; 2 – Complete text of the decision of the Portuguese Constitutional Court, of January 13, 2011, Judge Maria João ANTUNES (Reporter), Judge Carlos Pamplona de OLIVEIRA, Judge José Borges SOEIRO, Judge Gil GALVÃO, Judge Rui Manuel Moura RAMOS (President) –in terms of the tribunalconstitucional.pt, August 1, 2011; 3 – Brief annotation to the problem of the “medical act”; 3.1 – Plus some conclusions on the brief annotation to the problem of the “medical act”; 3.2 – Brief annotation to the problem of “consent”– continuation of the previous comments; 4 – Conclusions. It must never be forgotten that “consent” does not stand as the only cause of exclusion of unlawfulness.
Resumo:
The subject matter of this book is about piano methodology, including technical, musical, artistic, ethical and philosophical issues and reflections. The purpose of this work is to share a personal professional experience insight in the field of piano performance. This text assumes a certain continuity to the major contributions of artists like Ludwig Deppe, Tobias Matthay, Grigory Kogan, Heinrich Neuhaus and George Kochevitsky. At the same time, it tries to integrate and complement this selected literature, bringing new ideas and hints to specific professional issues.
Resumo:
OBJECTIVE: To carry out a survey data collection from health care workers in Brazil, Croatia, Poland, Ukraine and the USA with two primary goals: (1) to provide information about which aspects of well-being are most likely to need attention when shiftwork management solutions are being developed, and (2) to explore whether nations are likely to differ with respect to the impacts of night work on the well-being of workers involved in health care work. METHODS: The respondents from each nation were sorted into night worker and non-night worker groups. Worker perceptions of being physically tired, mentally tired, and tense at the end of the workday were examined. Subjective reports of perceived felt age were also studied. For each of these four dependent variables, an ANCOVA analysis was carried out. Hours worked per week, stability of weekly work schedule, and chronological age were the covariates for these analyses. RESULTS: The results clearly support the general proposal that nations differ significantly in worker perceptions of well-being. In addition, perceptions of physical and mental tiredness at the end of the workday were higher for night workers. For the perception of being physically tired at the end of a workday, the manner and degree to which the night shift impacts the workers varies by nation. CONCLUSIONS: Additional research is needed to determine if the nation and work schedule differences observed are related to differences in job tasks, work schedule structure, off-the-job variables, and/or other worker demographic variables.
Resumo:
The impact of shift and night work on health shows a high inter- and intra-individual variability, both in terms of kind of troubles and temporal occurrence, related to various intervening factors dealing with individual characteristics, lifestyles, work demands, company organisation, family relations and social conditions. The way we define "health" and "well-being" can significantly influence appraisals, outcomes and interventions. As the goal is the optimisation of shiftworkers' health, it is necessary to go beyond the health protection and to act for health promotion. In this perspective, not only people related to medical sciences, but many other actors (ergonomists, psychologists, sociologists, educators, legislators), as well as shiftworkers themselves. Many models have been proposed aimed at describing the intervening variables mediating and/or moderating the effects; they try to define the interactions and the pathways connecting risk factors and outcomes through several human dimensions, which refer to physiology, psychology, pathology, sociology, ergonomics, economics, politics, and ethics. So, different criteria can be used to evaluate shiftworkers' health and well-being, starting from biological rhythms and ending in severe health disorders, passing through psychological strain, job dissatisfaction, family perturbation and social dis-adaptation, both in the short- and long-term. Consequently, it appears rather arbitrary to focus the problem of shiftworkers' health and tolerance only on specific aspects (e.g. individual characteristics), but a systemic approach appears more appropriate, able to match as many variables as possible, and aimed at defining which factors are the most relevant for those specific work and social conditions. This can support a more effective and profitable (for individuals, companies, and society) adoption of preventive and compensative measures, that must refer more to "countervalues" rather than to "counterweights".
Resumo:
Celiac disease is a gluten-induced autoimmune enteropathy characterized by the presence of tissue tranglutaminase (tTG) autoantibodies. A disposable electrochemical immunosensor (EI) for the detection of IgA and IgG type anti-tTG autoantibodies in real patient’s samples is presented. Screen-printed carbon electrodes (SPCE) nanostructurized with carbon nanotubes and gold nanoparticles were used as the transducer surface. This transducer exhibits the excellent characteristics of carbon–metal nanoparticle hybrid conjugation and led to the amplification of the immunological interaction. The immunosensing strategy consisted of the immobilization of tTG on the nanostructured electrode surface followed by the electrochemical detection of the autoantibodies present in the samples using an alkaline phosphatase (AP) labelled anti-human IgA or IgG antibody. The analytical signal was based on the anodic redissolution of enzymatically generated silver by cyclic voltammetry. The results obtained were corroborated with a commercial ELISA kit indicating that the electrochemical immunosensor is a trustful analytical screening tool.
Resumo:
Nickel-copper metallic foams were electrodeposited from an acidic electrolyte, using hydrogen bubble evolution as a dynamic template. Their morphology and chemical composition was studied by scanning electron microscopy and related to the deposition parameters (applied current density and deposition time). For high currents densities (above 1 A cm(-2)) the nickel-copper deposits have a three-dimensional foam-like morphology with randomly distributed nearly-circular pores whose walls present an open dendritic structure. The nickel-copper foams are crystalline and composed of pure nickel and a copper-rich phase containing nickel in solid solution. The electrochemical behaviour of the material was studied by cyclic voltammetry and chronopotentiometry (charge-discharge curves) aiming at its application as a positive electrode for supercapacitors. Cyclic voltammograms showed that the Ni-Cu foams have a pseudocapacitive behaviour. The specific capacitance was calculated from charge-discharge data and the best value (105 F g(-1) at 1 mA cm(-2)) was obtained for nickel-copper foams deposited at 1.8 A cm(-2) for 180 s. Cycling stability of these foams was also assessed and they present a 90 % capacitance retention after 10,000 cycles at 10 mA cm(-2).
Resumo:
A flow injection analysis (FIA) system comprising a tartrate- (TAT) selective electrode has been developed for determination of tartaric acid in wines. Several electrodes constructed for this purpose had a PVC membrane with a complex of quaternary ammonium and TAT as anion exchanger, a phenol derivative as additive, and a more or less polar mediator solvent. Characterization of the electrodes showed behavior was best for membranes with o-nitrophenyl octyl ether as solvent. On injection of 500 μL into a phosphate buffer carrier (pH = 3.1; ionic strength 10–2 mol/L) flowing at 3 mL/min, the slope was 58.06 ± 0.6 with a lower limit of linear range of 5.0 × 10–4 mol/L TAT and R2 = 0.9989. The interference of several species, e.g. chloride, bromide, iodide, nitrate, gallic acid, tannin, sucrose, glucose, fructose, acetate, and citrate, was evaluated in terms of potentiometric selectivity coefficients. The Hofmeister series was followed for inorganic species and the most interfering organic ion was citrate. When red and white wines were analyzed and the results compared with those from an independent method they were found to be accurate, with relative standard deviations below 5.0%.