912 resultados para muscular fatigue
Resumo:
Application of high temperature superconductor Bi2Sr2Ca2Cu3Ox. (Bi-2223) compound embedded in an Ag matrix requires the knowledge of critical current as a function of mechanical properties. Commercial tapes available in different types have been developed in industrial production scale in which a combination of small diameter filaments, long tape lengths and a ductile matrix results in a conductor with low crack formation and good tolerance against strain. The measurement of critical current and the evaluation of n-index from V-I characteristic curves of Bi-2223/Ag composite tapes subjected to an initial bending strain as a function of number of thermal cycles were done for two types of Bi-2223/Ag composite tapes: with and without steel tape reinforcement. The results showed that tapes with reinforcement presented small critical current degradation as a function of the number of thermal cycles whereas tapes without reinforcement exhibited steadily critical current degradation caused by the propagation of cracks. The n-index followed the same critical current behavior.
Resumo:
Fatigue is an important problem to be considered if a ferroelectric film is used for non-volatile memory devices. In this phenomena, the remanent polarization and coercive field properties degrades in cycles which increase in hysteresis loops. The reasons have been attributed to different mechanisms such as a large voltage applied on ferroelectric film in every reading process in Ferroelectric Random Access Memory (FeRAM) or memories for digital storage in computer, grain size effects and others. The aim of this work is to investigate the influence of the crystallization kinetics on dielectric and ferroelectric properties of the Pb(Zr0.53Ti0.47)O-3 thin films prepared by an alternative chemical method. Films were crystallized in air on Pt/Ti/SiO2/Si substrates at 700 degrees C for 1 hour, in conventional thermal annealing (CTA), and at 700 degrees C for 1 min and 700 degrees C 5 min, using a rapid thermal annealing (RTA) process. Final films were crack free and presented an average of 750 nm in thickness. Dielectric properties were studied in the frequency range of 100 Hz - 1 MHz. All films showed a dielectric dispersion at low frequency. Ferroelectric properties were measured from hysteresis loops at 10 kHz. The obtained remanent polarization (P-r) and coercive field (E-c) were 3.7 mu C/cm(2) and 71.9 kV/cm respectively for film crystallized by CTA while in films crystallized by RTA these parameters were essentially the same. In the fatigue process, the P, value decreased to 14% from the initial value after 1.3 x 10(9) switching cycles, for film by CTA, while for film crystallized by RTA for 5 min, P, decreased to 47% from initial value after 1.7 x 10(9) switching cycles.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The tension-tension fatigue behavior of metal/fiber laminates (MFLs) has been investigated. These MFLs were produced with carbon fiber and by treating the aluminum foil to promote adhesion bonding by two methods: sulfuric-boric-oxalic acid anodization (SBOA) and chromic acid anodization (CAA). The surface treatments were evaluated by scanning electron microscopy (SEM) techniques and roughness measurements. It was observed that MFL specimens produced with SBOA treatments presents comparable mechanical results when compared with MFLs produced with CAA treatment. Microstructural observations of the fracture surfaces by SEM show hackle formation is the predominant damage mechanism.
Resumo:
OBJETIVO: Comparar a atividade muscular antes e após o contato com o solo entre as aterrissagens unilateral (AU) e bilateral (AB) em atletas do sexo masculino. PARTICIPANTES: Quinze atletas masculinos de voleibol sem sinais e sintomas de lesões nas extremidades inferiores (13 ± 1 ano, 1,70 ± 0,12m, 60 ± 12kg). MENSURAÇÕES:Os participantes realizaram dois saltos verticais, aterrissando unilateralmente e bilateralmente. A atividade mioelétrica do reto femoral (RF), bíceps femoral (BF), adutores de quadril (AQ) e a relação BF/RF foram comparados entre as duas aterrissagens e entre as fases caracterizadas por 100ms antes (PRE) e 100ms após (POS) o contato com o solo. RESULTADOS: Em ambas as aterrissagens, a ativação do RF foi maior na fase POS em relação à PRE. Na comparação entre as aterrissagens dentro da mesma fase não encontramos diferenças estatísticas. Apesar de o BF não ter apresentado diferenças entre as fases PRE e POS em cada aterrissagem, sua ativação foi maior na AU. Os AQ apresentaram maior ativação na fase POS durante a AU, no entanto não houve diferenças quando comparadas as duas aterrissagens. A relação BF/RF apresentou valores maiores em ambas as aterrissagens na fase PRE. No entanto, não encontramos diferenças entre as aterrissagens. CONCLUSÃO: Os resultados sugerem que cada músculo apresenta um papel diferente durante a fase de aterrissagem em homens. Enquanto que o RF possui como principal função a frenagem da articulação do joelho e do movimento descendente, caracterizada pelo aumento da ativação na fase pós-contato, o BF parece atenuar a tensão articular do joelho em atividades de maior impacto, mantendo-se mais ativo durante todo o ciclo da AU. Já a maior ativação dos AQ após o contato com solo na AU evidencia a importância da região lombo-pélvica na estabilização pélvica em situações de grande instabilidade. Estudos futuros são necessários para determinar os efeitos da ativação muscular apresentada na imposição de cargas mecânicas potencialmente lesivas no joelho em atletas do sexo masculino.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In variable-amplitude loading there are interaction effects between the loading history and the crack propagation rate. The most important of these effects is the retardation in the crack propagation, which may raise the life of the cracked structureconsiderably. The main objective of this research is to analyse and quantify the retardation of crack propagation in a thin plate of the high-resistance aluminium alloy 2024-T3, comparing the results obtained from the mathematical models proposed to account for the retardation effect. The specimens were tested under high-low loading sequences, for different crack sizes and overload ratios. A simplified model was developed, based on crack closure theory, that could represent the crack behaviour during retardation very well. © 1991.
Resumo:
The use of anthropometric measurements of triceps (TSF) and subscapular skinfolds (SSF) and mid-upper arm muscle circumference (MAMC) was examined as far as the diagnosis of energy-protein malnutrition (EPM) is concerned. The study was undertaken in five groups of patients (n = 231): arterial hypertension (AH, n = 63), chronic obstructive pulmonary disease (COPD, n = 17), hemodialyzed chronic renal failure (CRF, n = 19), critically ill patients with an acute event (CA, n = 42) and critically ill patients with chronic diseases (CCD, n = 90). The results were compared to those obtained in a group of healthy individuals (control group, n = 102). The control group and the group of patients were allocated in subgroups according to sex and age (less than 50 and more than 50 years). It was expected that significant differences would be found for the anthropometric values between the control subgroups and the COPD, the CRF and the CCD subgroups of patients. For the skinfold thicknesses (TSF and SSF), significant differences were found between CRF, CCD subgroups and the control subgroups under fifty years of age; however, the differences were not significant when the subgroups over fifty were analyzed. Concerning the MAMC, significant differences were found: 1 degree) between the CRF subgroups (males and females) and the control subgroups under fifty years of age; 2 degrees) between the CCD male subgroups (younger and older subgroups) and the respective control subgroups and 3 degrees) between the COPD and the control subgroups.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
Fatigue crack initiation occurs at the surface, although sub surface nucleation has also been reported. Localized imperfections like inclusions close to surface and surface small pits can result in crack sources. Coatings are not always beneficial by fatigue point of view too. Mechanical properties of the covering material can change considerably the fatigue behavior of base metal due to residual surface stresses, to micro cracks or to hydrogen embrittlement. This paper is concerned with analysis of electrolytic etch on the fatigue resistance of a 35NCD16 high strength steel in a mechanical condition of (1760 - 1960) MPa, and analysis of electroplated hard chromium effects on the fatigue resistance in a strength condition of 989 MPa. Hardness impression was used as a reference parameter in case of electrolytic etch. In both cases, experimental data showed that fatigue strength of 35NCD16 steel was considerably reduced. Copyright © 2001 Society of Automotive Engineers, Inc.
Resumo:
The objective of this study was to analyze the relationship of maximal aerobic power and the muscular strength (maximal isotonic strength and vertical jump explosive power) with the running economy (RE) in endurance athletes. Twenty-six male runners (27.9 ± 6.4 years; 62.7 ± 4.3 kg; 168.6 ± 6.1 cm; 6.6 ± 3.1% of body fat) performed in different days the following tests: a) incremental test to determine the maximal oxygen uptake (V̇O2max) and the intensity corresponding to the V̇O2max (IV̇O2max); b) constant-velocity treadmill run to determine RE; c) 1-RM test in the leg press and; d) maximal vertical jump test (VJ). V̇O2max (63.8 ± 8.3 ml/kg/min) was significantly correlated (r = 0.63; p < 0.05) with RE (48.0 ± 6.6 ml/kg/min). However, the IV̇O2max (18.7 ± 1.1 km/h), the maximal isotonic strength (230.3 ± 41.2 kg) and the VJ (30.8 ± 3.8 cm) were not significantly correlated with RE. One concludes that the maximal aerobic power can explain in part the inter-individual RE variability in endurance athletes. However, maximal isotonic strength and explosive strength seem not to be associated with RE values observed in this group of athletes.
Resumo:
The purpose of this study was to identify the Electromyographic Fatigue Threshold (EMG FT) of the biceps brachii muscle bilaterally during the elbow flexion in tests performed in different times: 30 second test, 1 minute test and fatiguing test, in concentric (CC) and eccentric (EC) phases. Nine healthy young men performed the elbow flexion with loads corresponding at 25%, 35% and 45% of the one repetition maximum (1-RM) in separate days. The results indicated that the test applied for the biceps brachii muscle during elbow flexion induced a progressive increment of EMG activity with time indicating muscle fatigue and allowed the identification of the EMG FT. The three tests presented no difference of EMG FT between CC and EC phases bilaterally.
Resumo:
It is well known that fatigue behaviour is an important parameter to be considered in mechanical components subjected to constant and variable amplitude loadings. In combination with corrosion phenomenon, fatigue effects were responsible for proximally 64% of fails that occur in metallic parts of aeronautical accidents in the last 30 years. Recovered substrates have been extensively used in the aerospace field. Cadmium electroplating has been widely applied to promote protective coatings in aeronautical components, resulting in excellent corrosion protection combined with a good performance in cyclic loading. Ecological considerations allied to the increasing demands for corrosion resistance, resulted in the search for possible alternatives. Zinc-nickel alloys received considerable interest recently, since these coatings showed some advantages such as a good resistance to white and red rust, high plating rates and acceptation in the market. In this study the effects of zinc-nickel coatings electroplated on AISI 4340 high strength steel were analysed on rotating bending and axial fatigue strength, corrosion and adhesion resistance. Compressive residual stress field was measured by a X-ray tensometry prior to fatigue tests. Optical microscopy images showed coating thicknesses, adhesion and the existence of an uniform coverage of nearly all substrates. The fractured fatigue specimens were investigated using a scanning electron microscope. Three different zinc-nickel coating thicknesses were tested and comparison with rotating bending fatigue data from specimens cadmium electroplated and heat treated at 190°C for 3, 8 and 24 hours to avoid the diffusion of hydrogen in the substrate, was performed. Experimental results showed effect of coatings on the AISI 4340 steel behaviour when submitted to fatigue testing and the existence of coating thickness influence on the fatigue strength.
Resumo:
The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.
Resumo:
Purpose: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. Materials and Methods: The null hypothesis is that the fatigue resistance varies with the luting strategy. Forty blocks of In-Ceram Alumina were prepared, and one surface of each block was abraded with 110-μm aluminum oxide particles. Then, the blocks were luted to flat dentin surfaces of 40 human third molars, using 4 different luting strategies (luting system [LS]/ceramic surface conditioning [CSC]) (n=10): (G1) [LS] RelyX-Unicem/[CSC] airborne abrasion with 110-μm Al2O3 particles; (G2) [LS] One-Step + Duo-Link (bis-GMA-based resin)/[CSC] etching with 4% hydrofluoric acid + silane agent; (G3) [LS] ED-Primer + Panavia F (MDP-based resin)/[CSC] Al2O 3; (G4) [LS] Scotchbond1+RelyX-ARC (bis-GMA-based resin)/[CSC] chairside tribochemical silica coating (air abrasion with 30-μm SiO x particles + silane). After 24 h of water storage at 37°C, the specimens were subjected to 106 fatigue cycles in shear with a sinusoidal load (0 to 21 N, 8 Hz frequency, 37°C water). A fatigue survivor score was given, considering the number of the fatigue cycles until fracture. The failure modes of failed specimens were observed in a SEM. Results: G3 (score = 5.9, 1 failure) and G4 (score = 6, no failures) were statistically similar (p = 0.33) and had significantly higher fatigue resistance than G1 (score = 3.9, 5 failures) and G2 (score = 3.7, 6 failures) (p < 0.03). SEM analysis of fractured specimens of G1 and G2 showed that almost all the failures were between ceramic and cement. Conclusion: The MDP-based resin cement + sandblasting with Al2O3 particles (G3) and bis-GMA-based resin cement + tribochemical silica coating (G4), both using the respective dentin bonding systems, were the best luting protocols for the alumina ceramic. The null hypothesis was confirmed.