986 resultados para modulation index
Gigabit/s modulation of twin-electrode high-brightness tapered laser with high modulation efficiency
Resumo:
Simultaneous high modulation speed and high modulation efficiency operation of a two-electrode tapered laser is reported. 1Gb/s direct data modulation is achieved with 68mA applied current swing for a 0.95W output optical modulation amplitude. © 2009 Optical Society of America.
Resumo:
Although long chain alkenones (LCKs) occur widely in lacustrine sediments, their origin is not clear. Here, we report a lacustrine source, the non-calcifying species Chrysotila lamellosa Anand (Haptophyceae), collected and isolated from an inland saline water body, Lake Xiarinur (Inner Mongolia, China). Its alketione pattern is similar to those of coastal marine strains of C lamellosa,but the relationship between U-37(K') index and culture temperature for the lacustrine species is quite different from that of the coastal species. A significant feature of the alkenones in this strain of C lamellosa is a lack of C-38 methyl alkenones, which might be used to distinguish the species from the marine haptophyte species Emiliania huxleyi and Gephyrocapsa oceanica. The higher C-38 tetraunsaturated compound abundance might be another important feature for distinguishing the C lamellosa alkenone producer from the coastal species Isochrysis galbana. This alkenone distribution pattern has been detected in many lakes, which suggests that C lamellosa or a closely related species might be a very common alkenone precursor in lacustrine systems. We examined U-37(K') and U-37(K) values for C lamellosa as a function of culture temperature in a batch culture experiment. The calibration for U-37(K') vs. culture temperature (T) was U-37(K') = 0.0011 x T-2 - 0.0157 x T + 0.1057(n = 14, r(2) = 0.99) from 10 degrees C to 22 degrees C or U-37(K') = 0.0257 x T - 0.2608(n = 9, r(2) = 0.97) from 14 degrees C to 22 degrees C. U-37(K) vs. culture temperature was U-37(K) = 0 0377 x T - 0.5992(n = 14, r(2) = 0.98) from 10 degrees C to 22 degrees C. Our experiments show that the alkenone unsaturation index (U-37(K')) is strongly controlled by culture temperature and can be used for palaeoclimate reconstruction. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The first known experimental demonstrations of a 10 Gb/s hybrid CAP-2/QAM-2 and a 20 Gb/s hybrid CAP-4/QAM-4 transmitter/receiver-based optical data link are performed. Successful transmission over 4.3 km of standard single-mode fiber (SMF) is achieved, with a link power penalty ∼0.4 dBo for CAP-2/QAM-2 and ∼1.5 dBo for CAP-4/QAM-4 at BER=10(-9).
Resumo:
We propose a new practical multimode fiber optical launch scheme, providing near single mode group excitation for >5 times transmission bandwidth improvement. Equalization-free transmission of a 10-Gb/s signal over 220-m fiber is achieved in experimental demonstrations. © 2010 Optical Society of America.
Resumo:
We demonstrate an on-chip all-optical broadband modulation of light in submicron silicon waveguide based on linear free carriers' absorption using side coupling configuration of a pump signal. © 2010 Optical Society of America.
Resumo:
100 Gb/s PAM4-CAP2 modulation is demonstrated for next-generation datacommunication links. Simulation studies indicate a power budget advantage of 2.5 dBo relative to PAM8 modulation. A real-time experimental demonstration is performed. © OSA 2014.
Resumo:
Protozoan were collected from 16 stations in water system of Changde City (China) using the PFU method. Sampling programs were conduced on a yearly basis, with seasonal frequency at diverse sites in the water system and 488 species of protozoa was identified. At the same time, Water sampling from these stations was conducted and various water chemical parameters, including DO, COD, BOD5, NH3, TP, and Volatile Phenol, were analyzed. The aim of the research was, on one hand, using chemical method to take an investigation to the water pollution status of Changde City; on the other hand, using protozoan to make an evaluation to the water quality. With the chemical water parameters and protozoa data, a biotic index was derived for the investigated region. The species pollution value (SPV) of 469 protozoa species was established, and the community pollution value (CPV) calculated from SPV was used to evaluate water quality. The method of the biotic index was tested and the result showed that CPV calculated from SPV had a close correlation with the degree of water pollution (p < 0.00001). This indicated that the method of the biotic index is reliable. The water quality degrees divided by CPV were suggested. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
A new class of 16-ary Amplitude Phase Shift Keying (APSK) coded modulations deemed double-ring PSK modulations best suited for (satellite) nonlinear channels is proposed. Constellation parameters optimization has been based on geometric and information-theoretic considerations. Furthermore, pre- and post-compensation techniques to reduce the nonlinearity impact have been examined. Digital timing clock and carrier phase have been derived and analyzed for a Turbo coded version of the same new modulation scheme. Finally, the performance of state-of the art Turbo coded modulation for this new 16-ary digital modulation has been investigated and compared to the known TCM schemes. It is shown that for the same coding scheme, double-ring APSK modulation outperforms classical 16-QAM and 16-PSK over a typical satellite nonlinear channel due to its intrinsic robustness against the High Power Amplifier (HPA) nonlinear characteristics. The new modulation is shown to be power- and spectrally-efficient, with interesting applications to satellite communications. © 2002 by the American Institute of Aeronautics and Astronautics, Inc.
Resumo:
A method of comparing data on protozoan communities with chemical parameters is presented. Using data from an extensive survey of the River Hanjiang in China, each species of protozoa has been given a species pollution value (SPV) related to its occurrence in waters with different degrees of pollution. A comprehensive chemical index is calculated for each site based on water quality standards for eight chemical parameters. The index is calculated from the relationship between the observed levels of each chemical at a site, compared with the limits of the drinking water quality standards of the People's Republic of China. From the distribution of each species at sites with differing chemical index values, a SPV is calculated. The SPV for each species is obtained by summing the logarithmic value of 10 times the chemical pollution divided by the number of chemical parameters, then divided by the stations where the species occurs. The community pollution value (CPV), which is the average SPVs of all protozoa at a site, is used to evaluate water quality. The CPV has been shown to have a close correlation with the degree of water pollution. It is not necessary for all the protozoa in a sample to have SPVs listed in this paper, provided at least 56% of the protozoa in a sample have an SPV value, the CPV will be applicable.
Resumo:
Protozoans of Lake Donghu were collected from five stations using the PFU method. The sampling was conducted for one year and two times a month. The aim of this research was to test the applicability of a new protozoa biotic index, species pollution value (SPV) and community pollution value (CPV), established by the authors using data from the River Hanjiang. Each station's CPV was calculated from the SPV and the correlation analysis between the CPV and the comprehensive chemical index of stations I, II, III showed a significant correlation between them. The pollution status of the five stations was correctly evaluated by the CPV. These results suggested that the biotic index could be applied in water systems other than the River Hanjiang. The SPV of some protozoa species in Lake Donghu, not observed in the River Hanjiang were established. In order to further test the applicability of the biotic index, protozoan and chemistry data from the Rivers Torrente Stirone and Parma of Italy were used. The results showed that the CPV for the two rivers had a close relationship with the chemical water quality, which indicated that the biotic index could be applied in other parts of the world for the monitoring and estimating of water quality. Since the results of testing and verifying the biotic index in some other water systems in China were also satisfactory, this indicated that the biotic index has an extensive suitability for freshwater ecosystems. As long as more than 50% of the species in a sample have a SPV, the CPV calculated from the SPV is reliable for monitoring and evaluating water quality.
Resumo:
Transmission properties of data amplitude modulation (AM) and frequency modulation (FM) in radio-over-fiber (RoF) system are studied numerically. The influences of fiber dispersion and nonlinearity on different microwave modulation schemes, including double side band (DSB), single side band (SSB) and optical carrier suppression (OCS), are investigated and compared. The power penalties at the base station (BS) and the eye opening penalties of the recovered data at the end users are both calculated and analyzed. Numerical simulation results reveal that the power penalty of FM can be drastically decreased due to the larger modulation depth it can achieve than that of AM. The local spectrum broadening around subcarrier microwave frequency of AM due to fiber nonlinearity can also be eliminated with FM. It is demonstrated for the first time that the eye openings of the FM recovered data can be controlled by its modulation depths and the coding formats. Negative voltage encoding format was used to further decrease the RF frequency thus increase the fluctuation period considering their inverse relationship.
Resumo:
Variations in optical spectrum and modulation band-width of a modulated Fabry-Perot (FP) semiconductor laser subject to the external light injection from another FP Laser is investigated in this paper. Optimal wavelength matching conditions for two FP lasers are discussed. A series of experiments show that two FP lasers should have a central wavelength overlapping and a mode spacing difference of several gigahertz. Under these conditions both the magnitude and phase frequency responses can be improved significantly.
Resumo:
In this letter, the power spectrum of a cooled distributed feedback laser module is measured using the self-heterodyne technique. Periodical oscillation peaks have been observed in the measurement. Further investigation shows that the additional modulation signal is coupled from the thermal electric cooler (TEC) controller to the laser driver, and then applied to the laser diode. The additional modulation can be eliminated by properly isolating the laser driving source from the TEC controller.
Resumo:
The interface dipole and its role in the effective work function (EWF) modulation by Al incorporation are investigated. Our study shows that the interface dipole located at the high-k/SiO2 interface causes an electrostatic potential difference across the metal/high-k interface, which significantly shifts the band alignment between the metal and high-k, consequently modulating the EWF. The electrochemical potential equalization and electrostatic potential methods are used to evaluate the interface dipole and its contribution. The calculated EWF modulation agrees with experimental data and can provide insight to the control of EWF in future pMOS technology.
Resumo:
A 1.55 mu m InGaAsP-InP index-coupled two-section DFB self-pulsation laser (SPL) with a varied ridge width has been fabricated. A record wide self-pulsation tuning range above 450 GHz has been achieved for this index-coupled DFB SPL. Furthermore, frequency locking to an optically injected modulated signal is successfully demonstrated.