913 resultados para high-resistant material
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Innate and acquired resistance to rabies infection was investigated in mice genetically selected for high (H) or low (L) antibody responsiveness from selections I, III and IV and in mice selected for maximal (AIRmax) or minimal (AIRmin) acute inflammatory reaction. These mouse lines were infected intramuscularly with different virus dilutions and the LD50 was determined. The HIII and HIV mouse lines were more susceptible than the LIII and LIV lines and the HI line showed a discrete but higher resistance than the LI line. Analysis of the interline (H x L) F1 hybrids from selections III and IV indicated different dominance effects on the resistant and susceptible phenotypes when the route of vaccination was changed. No differences were observed between the AIRmax and AIRmin mice, suggesting that inflammation plays a minor role in the resistance to rabies virus. The comparison of LD50 in mice vaccinated by distinct routes showed that the highest interline difference occurred after intramuscular vaccination (250-fold between H and L and 800-fold between F1 and L). These results indicate that different mechanisms may participate in acquired antirabies resistance
Resumo:
OBJETIVO: Avaliar a atividade in vitro da cefalosporina de quarta geração, cefpiroma em comparação com ceftazidima, ceftriaxona, cefotaxima e imipenem em um estudo multicêntrico envolvendo nove hospitais de seis cidades em quatro estados. MATERIAL E MÉTODOS: Foram estudadas 804 amostras clínicas isoladas em pacientes internados em unidades de terapia intensiva ou unidades de oncohematologia. As amostras foram coletadas no período de junho a novembro de 1995, isto é, antes da cefpiroma estar disponível comercialmente no Brasil, e testadas através do método de microdiluição em placas conforme descrito pelo National Committee for Clinical Laboratory Standards (NCCLS). Todas as amostras resistentes à cefpiroma foram retestadas utilizando-se o E-test. RESULTADOS: Contra as amostras de enterobactérias (n= 344), a cefpiroma apresentou atividade de 2 a 32 vezes superior àquela apresentada pelas cefalosporinas de terceira geração (CTGs) e semelhante àquela apresentada pelo imipenem. As porcentagens de enterobactérias sensíveis foram: 88% para a cefpiroma, 69% para as CTGs e 96% para o imipenem. O espectro de ação da cefpiroma foi maior ou igual ao do imipenem contra as espécies Citrobacter freundii, E. aerogenes, Morganella morganii e Serratia marcescens. Contra Acinetobacter sp. (n=77), a cefpiroma foi ligeiramente mais ativa que a ceftazidima, porém as porcentagens de resistência foram muito altas para esses compostos (84% e 88% respectivamente). As atividades da cefpiroma, ceftazidima e imipenem foram semelhantes contra Pseudomonas aeruginosa (n=128), com MIC50/porcentagem de sensibilidade de 8/59%, 8/62% e 4/62% respectivamente. Contra bactérias aeróbias gram-positivas, a cefpiroma foi de 4 a 16 vezes mais ativa que as CTGs. Contra S. epidermidis e outras espécies de estafilococos coagulase-negativos a cefpiroma foi ligeiramente superior ao imipenem, porém, contra as outras espécies de bactérias gram-positivas avaliadas, o imipenem apresentou atividade um pouco superior. CONCLUSÃO: Os resultados desse estudo sugerem que, no Brasil, a cefpiroma apresenta espectro de ação superior ao das CTGs contra bactérias gram-negativas (Enterobacteriaceae e não-fermentadares) e gram-positivas e semelhante ao do imipenem contra algumas espécies de enterobactérias e contra P. aeruginosa.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
SnO2 ceramics doped with ZnO and WO3 were prepared by mixed oxide method. The effect of ZnO and WO3 additives could be explained by the substitution of Sn4+ by Zn2+ and W6+. The addition of WO3 inhibits the grain growth due to the segregation of SnZnWO8 and ZnWO6 at the grain boundaries without strong influence on the densification process. The electrical characterization (log E x log J) shows that the ternary system SnO2-ZnO-WO3 exhibits a very high resistivity of around 10(14) Omega M. Independently of the WO3 concentration, the electrical conductivity of the Sn02-ZnO-WO3 system is always lower than that of the undoped tin dioxide. (C) 2005 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Resumo:
Bending fatigue tests were carried out to clarify the effects of heat treatment parameters: temperature and time after cadmium electroplating on a high strength steel, to avoid hydrogen embrittlement. Temperatures heat of 190 degrees C, 230 degrees C, 250 degrees C and 300 degrees C at 3, 8 and 24 hours together with the base material electroplated, with and without heat treatment, resulted in 14 conditions studied with respect to fatigue behaviour. Statistical data analysis was performed to identify the best combination temperature/time regarding fatigue strength of the ABNT 4340 steel and the results obtained revealed that the fatigue strength depend on temperature/time conditions.
Resumo:
The preparation of the ZrO(2):8 mol % Y(2)O(3)/NiO (YSZ/NiO) composites by a modified liquid mixture technique is reported. Nanometric NiO particles dispersed over the yttria-stabilized zirconia (YSZ) were prepared, resulting in dense sintered specimens with no solid solution formation between the oxides. Such a feature allowed for the electrical characterization of the composites in a wide range of relative volume fraction, temperature, and oxygen partial pressure. The main results indicate that the composites have high electrical conductivity, and the transport properties in these mixed ionic-electronic (MIEC) composites are strongly dependent on the relative volume fraction of the phases, microstructure, and temperature. These parameters should hence be taken into consideration for the optimized design of MIEC composites for electrochemical applications. In this context, the composite was reduced under H(2) for the preparation of high-conductivity YSZ/Ni cermets for use as solid oxide fuel cell anode material with relatively low metal content. (c) 2005 the Electrochemical Society. [DOI:10.1149/1.2149312] All rights reserved.
Resumo:
Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis.Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser.Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05).Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively).Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.
Resumo:
Nitrogen implantation into Ti alloys at higher temperatures improves their mechanical and corrosion resistance properties by forming a thicker nitride layer. In this paper, two different sets of Ti-6Al-4V samples were plasma immersion ion implantation (PIII)-treated using nitrogen plasma, varying the treatment time from 30 to 150 min (800 degrees C) and the process temperature from 400 degrees C to 800 degrees C (t = 60 min). Nanoindentation measurements of the PIII-treated samples at 800 C during 150 min showed the highest hardness value, 24 GPa, which is about four times bigger than untreated sample hardness. The N penetration at these conditions reached approximately 150 nm as analyzed by Auger spectroscopy. on the other hand, the lowest passive current density (3 x 10(-7) A. cm(-2)) was obtained for a PIII-treated sample during 30 min at higher temperature (800 degrees C). The corrosion resistance of this sample is almost the same as for the untreated specimen. Corrosion behavior evidenced that in strong oxidizing media, all PIII-treated samples are more corrosion resistant than the untreated one. PIII processing at higher temperatures promotes smoothing of the sample surface as observed by scanning electron microscopy (SEM). Grazing incidence X-ray diffraction analyses of the untreated samples identified the two typical Ti phases, Ti alpha and Ti beta. After the implantation, Ti2N and TiO2 phases were also detected.
Resumo:
Reduced susceptibility or resistance to vancomycin has been reported among clinical isolates of staphylococci in previous studies. In the present study we report on the isolation of four vancomycin-resistant staphylococcal strains from healthy carriers inside and outside the hospital environment. These carriers did not receive treatment with any antibiotic. All coagulase-negative staphylococcal strains showed variable levels of resistance to several antimicrobial agents, including oxacillin, and unstable resistance to vancomycin, with decreased vancomycin MICs (<4 mg/liter) after 10 days of passage in a nonselective medium. However, exposure of these revertants to vancomycin selected staphylococcal strains resistant to vancomycin at very high frequencies (10(-2) and 10(-3)). The vancomycin resistance in these staphylococcal strains was not mediated by the van gene. The cell wall of the staphylococcal strains studied became thickest after culture in medium containing vancomycin, and the differences in cell wall thickness were statistically significant (P < 0.001). Thus, the thickening of the cell wall in these staphylococcal strains may be an important contributor to vancomycin resistance.
Resumo:
A specific and sensitive high-performance liquid chromatographic procedure was developed for the assay of sparfloxacin in raw material and tablets. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The method validation yielded good results and included the range, linearity, precision, accuracy, specificity and recovery. This method can also be applied to stability studies. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
We describe the design, manufacturing, and testing results of a Nb3Sn superconducting coil in which TiAIV alloys were used instead of stainless steel to reduce the magnetization contribution caused by the heat treatment for the A-15 Nb-3 Sn phase formation that affects the magnetic field homogeneity. Prior to the coil manufacturing several structural materials were studied and evaluated in terms of their mechanical and magnetic properties in as-worked, welded, and heat-treated conditions. The manufacturing process employed the wind-and-react technique followed by vacuum-pressure impregnation(VPI) at 1 MPa atm. The critical steps of the manufacturing process, besides the heat treatment and impregnation, are the wire splicing and joint manufacturing in which copper posts supported by Si3N4 ceramic were used. The coil was tested with and without a background NbTi coil and the results have shown performance exceeding the design quench current confirming the successful coil construction.