899 resultados para determination of value


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article aims to discuss the needs and problems of marolo value chain, as well as to evaluate the rehydration process of this fruit as a possibility of using it as a by-product during the interharvest growth periods. The study of the value chain included interviews with producers, handlers, and fruit and by-product sellers. In order to evaluate the rehydration process of this fruit, marolo was dehydrated using a conventional procedure and freeze-drying. The experiments were conducted in a completely randomized design and a triple factorial scheme (2 × 2 × 6). ANOVA was performed, followed by the Tukey's test (p < 0.05). Regression models were generated and adjusted for the time factor. The precariousness of the value chain of marolo was observed. The best procedure for marolo dehydration should be determined according to the intended use of the dehydrated product since the water-absorption capacity of the flour is higher and convective hot-air-drying is more effective in retaining soluble solids and reducing damage to the fruit. These results aim at contributing to the marolo value chain and to the preservation of native trees in the Brazilian savanna biome and can be used to analyze other underutilized crops.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sugars in apple juice prove its authenticity and its sensory and nutritional properties. The aim of this study was to develop and validate a simple analytical method using high performance liquid chromatography with refractive index detection (HPLC-RI) to determinate and quantify the sugars sucrose, D-glucose, D-fructose, and D-sorbitol polyol in apple juices, as well as to analyze the juices from the Fuji suprema and Lis Gala cultivars at three ripening stages. The analytical performance parameters evaluated indicated that the method was specific for the compounds analyzed, and the linearity of the calibration curves of sugars showed high correlation coefficients (close to 1.0). The limits of detection and quantification are consistent with recommendations available in the literature for this type of matrix. Sample preparation is simple and generates small amount of residues. Over 70% of the sugars were determined in the juices of apples at the pre-ripe stage, with an increase during senescence. This method is applicable for the determination of sugars in juices and evaluation of apple ripening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Celery (Apium graveolens L. var. secalinum Alef) leaves with 50±0.07 g weight and 91.75±0.15% humidity (~11.21 db) were dried using 8 different microwave power densities ranging between 1.8-20 W g-1, until the humidity fell down to 8.95±0.23% (~0.1 db). Microwave drying processes were completed between 5.5 and 77 min depending on the microwave power densities. In this study, measured values were compared with predicted values obtained from twenty thin layer drying theoretical, semi-empirical and empirical equations with a new thin layer drying equation. Within applied microwave power density; models whose coefficient and correlation (R²) values are highest were chosen as the best models. Weibull distribution model gave the most suitable predictions at all power density. At increasing microwave power densities, the effective moisture diffusivity values ranged from 1.595 10-10 to 6.377 10-12 m2 s-1. The activation energy was calculated using an exponential expression based on Arrhenius equation. The linear relationship between the drying rate constant and effective moisture diffusivity gave the best fit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to precool cauliflower using forced-air, vacuum and high and low flow hydro cooling methods. The weight of the precooled cauliflower heads (5000±5 g) was measured before they were placed in standard plastic crates. Cauliflower heads, whose initial temperature was 23.5 ± 0.5 ºC, were cooled until the temperature reached at 1 ºC. During the precooling process, time-dependent temperature and energy consumption were measured, and during vacuum precooling, the decreasing pressure values were recorded, and a curve of time-dependent pressure decrease (vacuum) was built. The most suitable cooling method to precool cauliflower in terms of cooling time and energy consumption was vacuum, followed by the high and low flow hydro and forced-air precooling methods, respectively. The highest weight loss was observed in the vacuum precooling method, followed by the forced-air method. However, there was an increase in the weight of the cauliflower heads in the high and low flow hydro precooling method. The best colour and hardness values were found in the vacuum precooling method. Among all methods tested, the most suitable method to precool cauliflower in terms of cooling and quality parameters was the vacuum precooling method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cauliflower heads, which were precooled using four different methods including vacuum, forced-air, and high and low flow hydro precooling, were stored under controlled atmosphere and room conditions. Controlled atmosphere conditions (CA) were as follows: 1°C temperature, 90 ± 5% relative humidity, and 0:21 [(%CO2:%O2) – (0:21) control] atmosphere composition. Room conditions (RC) were: 22±1°C temperature and 55-60% humidity. Various quality parameters of the cauliflower heads were assessed during storage (days 0, 7, 14, 21, 28, and 35) under controlled atmosphere and room conditions (days 0, 5, and 10). During storage, weight loss, deterioration rate, overall sensory quality score, hardness, and colour (L, a, b, C and α) were evaluated. In the present study, the strength and quality parameters of cauliflower under CA and RC conditions were obtained. Vacuum precooling was found to be most suitable method before cauliflower was submitted to cold storage and sent to market. Furthermore, the storage of cauliflower without precooling resulted in a significant decrease in quality parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract An accurate, reliable and fast multianalyte/multiclass ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed and validated for the simultaneous analysis of 23 pharmaceuticals, belonging to different classes amphenicols, sulfonamides, tetracyclines, in honey samples. The method developed consists of ultrasonic extraction followed by UPLC–ESI–MS/MS with electrospray ionization in both positive mode and negative mode. The influence of the extraction solvents and mobile phase composition on the sensitivity of the method, and the optimum conditions for sample weight and extraction temperature in terms of analyte recovery were extensively studied. The identification of antibiotics is fulfilled by simultaneous use of chromatographic separation using an Acquity BEH C18 (100 mm x 2.1 mm, 1.7 µm) analytical column with a gradient elution of mobile phases and tandem mass spectrometry with an electrospray ionization. Finally, the method developed was applied to the determination of target analytes in honey samples obtained from the local markets and several beekeepers in Muğla, Turkey. Ultrasonic-extraction of pharmaceuticals from honey samples is a well-established technique by UPLC–ESI–MS/MS, the uniqueness of this study lies in the simultaneous determination of a remarkable number of compounds belonging to 23 drug at the sub-nanogram per kilogram level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach to the determination of the thermal parameters of high-power batteries is introduced here. Application of local heat flux measurement with a gradient heat flux sensor (GHFS) allows determination of the cell thermal parameters in di_erent surface points of the cell. The suggested methodology is not cell destructive as it does not require deep discharge of the cell or application of any charge/discharge cycles during measurements of the thermal parameters of the cell. The complete procedure is demonstrated on a high-power Li-ion pouch cell, and it is verified on a sample with well-known thermal parameters. A comparison of the experimental results with conventional thermal characterization methods shows an acceptably low error. The dependence of the cell thermal parameters on state of charge (SoC) and measurement points on the surface was studied by the proposed measurement approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis investigates the performance of value and momentum strategies in the Swedish stock market during the 2000-2015 sample period. In addition the performance of some value and value-momentum combination is examined. The data consists of all the publicly traded companies in the Swedish stock market between 2000-2015. P/E, P/B, P/S, EV/EBITDA, EV/S ratios and 3, 6 and 12 months value criteria are used in the portfolio formation. In addition to single selection criteria, combination of P/E and P/B (aka. Graham number), the average ranking of the five value criteria and EV/EBIT – 3 month momentum combination is used as a portfolio-formation criterion. The stocks are divided into quintile portfolios based on each selection criterion. The portfolios are reformed once a year using the April’s price information and previous year’s financial information. The performance of the portfolios is examined based on average annual return, the Sharpe ratio and the Jensen alpha. The results show that the value-momentum combination is the best-performing portfolio both during the whole sample period and during the sub-period that started after the 2007-financial crisis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents an understanding of how a U.S. based, international MBA school has been able to achieve competitive advantage within a relatively short period of time. A framework is built to comprehend how the dynamic capability and value co-creation theories are connected and to understand how the dynamic capabilities have enabled value co-creation to happen between the school and its students, leading to such competitive advantage for the school. The data collection method followed a qualitative single-case study with a process perspective. Seven semi-structured interviews were made in September and October of 2015; one current employee of the MBA school was interviewed, with the other six being graduates and/or former employees of the MBA school. In addition, the researcher has worked as a recruiter at the MBA school, enabling to build bridges and a coherent whole of the empirical findings. Data analysis was conducted by first identifying themes from interviews, after which a narrative was written and a causal network model was built. Thus, a combination of thematic analysis, narrative and grounded theory were used as data analysis methods. This study finds that value co-creation is enabled by the dynamic capabilities of the MBA school; also capabilities would not be dynamic if value co-creation did not take place. Thus, this study presents that even though the two theories represent different level analyses, they are intertwined and together they can help to explain competitive advantage. The MBA case school’s dynamic capabilities are identified to be the sales & marketing capabilities and international market creation capabilities, thus the study finds that the MBA school does not only co-create value with existing students (customers) in the school setting, but instead, most of the value co-creation happens between the school and the student cohorts (network) already in the recruiting phase. Therefore, as a theoretical implication, the network should be considered as part of the context. The main value created seem to lie in the MBA case school’s international setting & networks. MBA schools around the world can learn from this study; schools should try to find their own niche and specialize, based on their own values and capabilities. With a differentiating focus and a unique and practical content, the schools can and should be well-marketed and proactively sold in order to receive more student applications and enhance competitive advantage. Even though an MBA school can effectively be treated as a business, as the study shows, the main emphasis should still be on providing quality education. Good content with efficient marketing can be the winning combination for an MBA school.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml"* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h"^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l'l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml'l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An efficient way of synthesizing the deuterium labelled analogues of three methoxypyrazine compounds: 2-d3-methoxy-3-isopropylpyrazine, 2-d3-methoxy-3- isobutylpyrazine, and 2-d3-methoxy-3-secbutylpyrazine, has been developed. To confirm that the deuterium labels had been incorporated into the expected positions in the molecules synthesized, the relevant characterization by NMR, HRMS and GC/MS analysis was conducted. Another part of this work involved quantitative determination of methoxypyrazines in water and wines. Solid-phase extraction (SPE) proved to be a suitable means for the sample separation and concentration prior to GC/MS analysis.Such factors as the presence of ethanol, salt, and acid have been investigated which can influence the recovery by SPE for the pyrazines from the water matrix. Significantly, in this work comparatively simple fractional distillation was attempted to replace the conventional steam distillation for pre-concentrating a sample with a relatively large volume prior to SPE. Finally, a real wine sample spiked with the relevant isotope-labelled methoxypyrazines was quantitatively analyzed, revealing that the wine with 10 beetles per litre contained 138 ppt of 2-methoxy-3-isopropylpyrazine. Interestingly, we have also found that 2-methoxy-3-secbutylpyrazine exhibits an extremely low detection limit in GC/MS analysis compared with the detection limit of the other two methoxypyrazines: 2- methoxy-3-isopropylpyrazine and 2-methoxy-3-isobutylpyrazine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple High Performance Liquid Chromatograph (HPLC) method has been developed to identify benamyl (methyl 1- (butylcarbamoyl)-2-benzimidazole carbamate) and MBC (methyl 2-benzimidazole carbamat~ residues on apple leaves without cleanup. Sample leaves are freeze dried in a Mason jar and residues are then extracted by tumbling them in chloroform containing 5,000 microgram per milliliter of n-propyl isocyanate (PIC) at 10 C. To the extract, n-butyl isocyanate (BIC) was added at 5,000 microgram per milliliter and 20 microliter of this mixture injected onto the HPLC system. Separation is accomplished by the use of a Brownlee LiChrosorb silica gel column with a guard column and' operated with a mixed mobile phase consisting of chloroform and hexane (4:1) saturated with water. MBC, a degradation product of benomyl is identified if present as methyl l-(npropyl carbamoyl)-2-benzimidazole carbamate (MBC-n-PIC). Both benomyl and MBC-n-PIC can be detected with aKUltraviolet (UV) detector (280nm) at a concentration as low as 0.2 microgram per milliliter in apple leaves. The fate of benomyl on apple foliage after spray application of benomyl (Ben late 50 per cent wettable powder) was investigated by the method thus described. Benomyl quickly dissipated during the first 3-7 days, but the dissipatio'n sltowed down thereafter. In contrast, the concentration of MBC in leaves gradually increased after repeated applications of Benlate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arsenic, bismuth, germanium, antimony and tin were simultaneously determined by continuous hydride generation and inductively coupled plasma-atomic emission spectrometry . I Hydrides were introduced into four different types of gas-liquid separators. Two of the gas-liquid separators were available in-house. A third was developed for this project and a fourth was based on a design used by CET AC. The best signal intensity was achieved by the type II frit-based gas-liquid separator, but the modified Cetac design gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained between experimental values and certified values for arsenic, bismuth, antimony and tin. The method was developed to provide the analyst with the opportunity to determine the analytes by using simple aqueous standards to prepare calibration lines. Within the limits of the samples analyzed, the method developed is independent of matrix.