996 resultados para coronal dentin
Resumo:
Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth
Resumo:
PURPOSE: To describe the anatomical characteristics and patterns of neurovascular compression in patients suffering classic trigeminal neuralgia (CTN), using high-resolution magnetic resonance imaging (MRI). MATERIALS AND METHODS: The analysis of the anatomy of the trigeminal nerve, brain stem and the vascular structures related to this nerve was made in 100 consecutive patients treated with a Gamma Knife radiosurgery for CTN between December 1999 and September 2004. MRI studies (T1, T1 enhanced and T2-SPIR) with axial, coronal and sagital simultaneous visualization were dynamically assessed using the software GammaPlan?. Three-dimensional reconstructions were also developed in some representative cases. RESULTS: In 93 patients (93%), there were one or several vascular structures in contact, either, with the trigeminal nerve, or close to its origin in the pons. The superior cerebellar artery was involved in 71 cases (76%). Other vessels identified were the antero-inferior cerebellar artery, the basilar artery, the vertebral artery, and some venous structures. Vascular compression was found anywhere along the trigeminal nerve. The mean distance between the nerve compression and the origin of the nerve in the brainstem was 3.76±2.9mm (range 0-9.8mm). In 39 patients (42%), the vascular compression was located proximally and in 42 (45%) the compression was located distally. Nerve dislocation or distortion by the vessel was observed in 30 cases (32%). CONCLUSIONS: The findings of this study are similar to those reported in surgical and autopsy series. This non-invasive MRI-based approach could be useful for diagnostic and therapeutic decisions in CTN, and it could help to understand its pathogenesis.
Resumo:
OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.
Resumo:
Fibre-reinforced composite (FRC) root canal posts are suggested to have biomechanical benefits over traditional metallic posts, but they lack good adhesion to resin composites. The aim of this series of studies was to evaluate the adhesion of individually formed fibre-reinforced composite material to composite resin and dentin, as well as some mechanical properties. Flexural properties were evaluated and compared between individually formed FRC post material and different prefabricated posts. The depth of polymerization of the individually formed FRC post material was evaluated with IR spectrophotometry and microhardness measurements, and compared to that of resin without fibres. Bonding properties of the individually formed FRC post to resin cements and dentin were tested using Pull-out- and Push-out-force tests, evaluated with scanning electron microscopy, and compared to those of prefabricated FRC and metal posts. Load-bearing capacity and microstrain were evaluated and failure mode assessment was made on incisors restored with individually formed FRC posts of different structures and prefabricated posts. The results of these studies show that the individually polymerized and formed FRC post material had higher flexural properties compared to the commercial prefabricated FRC posts. The individually polymerized FRC material showed almost the same degree of conversion after light polymerization as monomer resin without fibres. Moreover, it was found that the individually formed FRC post material with a semiinterpenetrating polymer network (IPN) polymer matrix bonded better to composite resin luting cement, than did the prefabricated posts with a cross-linked polymer matrix. Furthermore, it was found that, contrary to the other posts, there were no adhesive failures between the individually formed FRC posts and composite resin luting cement. This suggests better interfacial adhesion of cements to these posts. Although no differences in load-bearing capacity or microstrain could be seen, the incisors restored with individually formed FRC posts with a hollow structure showed more favourable failures compared to other prefabricated posts. These studies suggest that it is possible to use individually formed FRC material with semi-IPN polymer matrix as root canal post material. They also indicate that there are benefits especially regarding the bonding properties to composite resin and dentin with this material compared to prefabricated FRC post material with a cross-linked matrix. Furthermore, clinically more repairable failures were found with this material compared to those of prefabricated posts.
Resumo:
Trinta e três pacientes esquizofrênicos crônicos e 21 indivíduos normais foram submetidos a exames de ressonância magnética em aparelho de 1,5 T, sendo realizadas imagens ponderadas em T2 nos planos axial e coronal. Foram analisados, por métodos morfométricos semi-automáticos, os volumes intracraniano, supratentorial, infratentorial, do líquido cefalorraquiano total, ventricular e subaracnóide e do encéfalo. Foram ainda medidos os volumes do complexo amígdala-hipocampo, córtex do giro para-hipocampal, putâmen, globo pálido, lobo temporal e substâncias branca e cinzenta do lobo temporal. Foram calculados os volumes relativos dessas estruturas, corrigidos pelo volume intracraniano. As alterações mais relevantes observadas nos esquizofrênicos, em comparação com os controles, foram de redução do volume relativo do encéfalo, aumento do volume relativo do líquido cefalorraquiano ventricular, subaracnóide e total. Foi ainda observada redução do volume dos complexos amígdala-hipocampo, dos lobos temporais e da substância branca dos lobos temporais, e aumento de volume dos putâmens.
Resumo:
We present a sample of three large near-relativistic (>50 keV) electron events observed in 2001 by both the ACE and the Ulysses spacecraft, when Ulysses was at high-northern latitudes (>60◦) and close to 2 AU. Despite the large latitudinal distance between the two spacecraft, electrons injected near the Sun reached both heliospheric locations. All three events were associated with large solar flares, strong decametric type II radio bursts and accompanied by wide (>212◦) and fast (>1400 km s−1) coronal mass ejections (CMEs). We use advanced interplanetary transport simulations and make use of the directional intensities observed in situ by the spacecraft to infer the electron injection profile close to the Sun and the interplanetary transport conditions at both low and high latitudes. For the three selected events, we find similar interplanetary transport conditions at different heliolatitudes for a given event, with values of the mean free path ranging from 0.04 AU to 0.27 AU. We find differences in the injection profiles inferred for each spacecraft. We investigate the role that sector boundaries of the heliospheric current sheet (HCS) have on determining the characteristics of the electron injection profiles. Extended injection profiles, associated with coronal shocks, are found if the magnetic footpoints of the spacecraft lay in the same magnetic sector as the associated flare, while intermittent sparse injection episodes appear when the spacecraft footpoints are in the opposite sector or a wrap in the HCS bounded the CME structure.
Resumo:
Objective: An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. Study design: Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA)(impacted and threaded, respectively), a machined titanium surface implant (TI mach), a titanium plasma spray surface implant (TPS), and a sandblasted, acid-etched surface implant (SBAE). A 0.5-mm diameter bone defect was made in the implant apical zone, and a type-K thermocouple (Termopar)® was placed in contact with the implant. The implants were irradiated in the coronal zone of each implant with a CO2 (4 W continuous mode) and an ErCr:YSGG laser (1.5 W, pulsed mode) first without and then with refrigeration. The temperature variations at the implant apical surface were recorded. Results: An apical temperature increase was recorded in all cases during CO2 and ErCr:YSGG laser irradiation without refrigeration. However, when the ErCr:YSGG was used with a water spray, a decrease in temperature was observed in all implants. The acid-etched and sandblasted surfaces were those most affected by the thermal changes. Conclusions: The ErCr:YSGG laser with a water spray applied to the sealing cap or coronal zone of the implants does not generate thermal increments in the apical surface capable of adversely affecting osseointegration and the integrity of the peri-implant bone tissue
Resumo:
PURPOSE: To meta-analyze the literature on the clinical performance of Class V restorations to assess the factors that influence retention, marginal integrity, and marginal discoloration of cervical lesions restored with composite resins, glass-ionomer-cement-based materials [glass-ionomer cement (GIC) and resin-modified glass ionomers (RMGICs)], and polyacid-modified resin composites (PMRC). MATERIALS AND METHODS: The English literature was searched (MEDLINE and SCOPUS) for prospective clinical trials on cervical restorations with an observation period of at least 18 months. The studies had to report about retention, marginal discoloration, marginal integrity, and marginal caries and include a description of the operative technique (beveling of enamel, roughening of dentin, type of isolation). Eighty-one studies involving 185 experiments for 47 adhesives matched the inclusion criteria. The statistical analysis was carried out by using the following linear mixed model: log (-log (Y /100)) = β + α log(T ) + error with β = log(λ), where β is a summary measure of the non-linear deterioration occurring in each experiment, including a random study effect. RESULTS: On average, 12.3% of the cervical restorations were lost, 27.9% exhibited marginal discoloration, and 34.6% exhibited deterioration of marginal integrity after 5 years. The calculation of the clinical index was 17.4% of failures after 5 years and 32.3% after 8 years. A higher variability was found for retention loss and marginal discoloration. Hardly any secondary caries lesions were detected, even in the experiments with a follow-up time longer than 8 years. Restorations placed using rubber-dam in teeth whose dentin was roughened showed a statistically significantly higher retention rate than those placed in teeth with unprepared dentin or without rubber-dam (p < 0.05). However, enamel beveling had no influence on any of the examined variables. Significant differences were found between pairs of adhesive systems and also between pairs of classes of adhesive systems. One-step self-etching had a significantly worse clinically index than two-step self-etching and three-step etch-and-rinse (p = 0.026 and p = 0.002, respectively). CONCLUSION: The clinical performance is significantly influenced by the type of adhesive system and/or the adhesive class to which the system belongs. Whether the dentin/enamel is roughened or not and whether rubberdam isolation is used or not also significantly influenced the clinical performance. Composite resin restorations placed with two-step self-etching and three-step etch-and-rinse adhesive systems should be preferred over onestep self-etching adhesive systems, GIC-based materials, and PMRCs.
Resumo:
OBJETIVO: Analisar a reprodutibilidade intra-observador da ultra-sonografia tridimensional (US3D) real com a US virtual, nas modalidades multiplanar e volumétrica. MATERIAIS E MÉTODOS: Foram examinados, prospectivamente, 132 blocos provenientes de 44 avaliações de 26 conceptos. Dezoito conceptos tinham idade gestacional ecográfica de oito semanas a oito semanas e seis dias, e 26 tinham de dez semanas a dez semanas e seis dias. Realizou-se a US3D, analisando-se: comprimento cabeça-nádega, saco gestacional, saco amniótico, translucência nucal, conduto onfalomesentérico, vesícula vitelínica, membros superiores, membros inferiores, distinção cabeça-tórax, perfil da face, coronal da face, implantação das orelhas, perfil da coluna, coronal da coluna, parede abdominal fechada. Foram obtidos três blocos por concepto para posterior realização da US virtual. A análise estatística foi feita utilizando-se o teste t de Student, o teste de McNemar e o kappa. RESULTADOS: No grupo I, a avaliação ultra-sonográfica 3D real multiplanar versus 3D virtual multiplanar, na análise das variáveis contínuas, evidenciou diferença significativa para todas. Na avaliação das variáveis categóricas, evidenciou-se que todas não apresentaram diferença significativa. No grupo II, a avaliação ultra-sonográfica 3D real volumétrica versus 3D virtual volumétrica demonstrou diferença significativa apenas para a variável implantação de orelhas. Os resultados das análises das variáveis categóricas evidenciaram concordância para a maioria das variáveis analisadas em ambos os grupos. CONCLUSÃO: Há reprodutibilidade intra-observador da US3D com a modalidade virtual, multiplanar e volumétrica.
Resumo:
A medida do comprimento cervical por ultra-sonografia transvaginal é útil no rastreamento do parto prematuro, sendo o encurtamento do colo fator preditor do trabalho de parto pré-termo. Os métodos tradicionais para avaliar a cérvice na gestação são limitados e insatisfatórios. O exame de toque digital, considerado método padrão, demonstra variação entre diferentes examinadores, entretanto, a ultra-sonografia transvaginal é exame eficiente durante a gravidez. Recentemente, o exame ultra-sonográfico tridimensional tem sido utilizado na prática clínica, incluindo o estudo do colo. Grande volume de informações pode ser obtido e armazenado utilizando-se a tecnologia tridimensional. A informação armazenada permite ser manipulada e analisada por número infinito de planos. O exame ultra-sonográfico transvaginal tridimensional é o único capaz de obter o plano coronal pela visualização da imagem em organização multiplanar. Este método aparenta oferecer potencial diagnóstico no aumento da acurácia da ultra-sonografia cervical.
Resumo:
Nicotine (NIC), the main psychostimulant compound of smoked tobacco, exerts its effects through activation of central nicotinic acetylcholine receptors (nAChR), which become up-regulated after chronic administration. Recent work has demonstrated that the recreational drug 3,4-methylenedioxymethamphetamine (MDMA) has affinity for nAChR and also induces up-regulation of nAChR in PC 12 cells. Tobacco and MDMA are often consumed together. In the present work we studied the in vivo effect of a classic chronic dosing schedule of MDMA in rats, alone or combined with a chronic schedule of NIC, on the density of nAChR and on serotonin reuptake transporters. MDMA induced significant decreases in [3H]paroxetine binding in the cortex and hippocampus measured 24 h after the last dose and these decreases were not modified by the association with NIC. In the prefrontal cortex, NIC and MDMA each induced significant increases in [3H]epibatidine binding (29.5 and 34.6%, respectively) with respect to saline-treated rats, and these increases were significantly potentiated (up to 72.1%) when the two drugs were associated. Also in this area, [3H]methyllycaconitine binding was increased a 42.1% with NIC + MDMA but not when they were given alone. In the hippocampus, MDMA potentiated the a7 regulatory effects of NIC (raising a 25.5% increase to 52.5%) but alone was devoid of effect. MDMA had no effect on heteromeric nAChR in striatum and a coronal section of the midbrain containing superior colliculi, geniculate nuclei, substantia nigra and ventral tegmental area. Specific immunoprecipitation of solubilised receptors suggests that the up-regulated heteromeric nAChRs contain a4 and b2 subunits. Western blots with specific a4 and a7 antibodies showed no significant differences between the groups, indicating that, as reported for nicotine, up-regulation caused by MDMA is due to post-translational events rather than increased receptor synthesis.
Resumo:
OBJETIVO: Verificar a relação entre sinais e sintomas observados no exame clínico de pacientes com diagnóstico de disfunção temporomandibular, conforme os resultados fornecidos pelo exame de ressonância magnética. MATERIAIS E MÉTODOS: Trinta pacientes que apresentavam sinais e sintomas de disfunção temporomandibular foram submetidos a exame clínico e de ressonância magnética. Cada exame de ressonância magnética de articulação temporomandibular foi interpretado, independentemente, por dois radiologistas experientes. Os exames de ressonância magnética foram realizados com 12 cortes de 3 mm de espessura, em orientação coronal (T1) em posição de boca fechada, cortes sagitais em posição de boca aberta e fechada (T1 e T2) e em abertura e fechamento progressivos, com intervalo de 5 mm, para reproduzir toda a extensão do movimento mandibular. A significância estatística entre a análise clínica dos pacientes com disfunção temporomandibular e os resultados obtidos no exame de ressonância magnética foi avaliada pelo teste kappa. RESULTADOS: Obteve-se, na análise interobservadores de imagens, concordância bruta do lado esquerdo e direito, respectivamente, de 56,7% (kappa = 0,1) e 56,7 (kappa = 0). CONCLUSÃO: Não foi encontrada correlação entre o diagnóstico clínico da luxação discal e imagens de ressonância magnética.
Resumo:
Relata-se, aqui, caso de uma adolescente de 14 anos de idade que apresentou episódio isolado de síncope, sem outros sintomas. No exame de ressonância magnética observou-se, nos cortes nos planos axial e coronal ponderados em T2, ausência do flow void da artéria carótida interna direita na sua porção intracavernosa. Realizou-se, então, angiorressonância magnética técnica time-of-flight, que mostrou ausência da artéria carótida interna direita, o que foi comprovado com a angiorressonância magnética de vasos cervicais e com angiotomografia computadorizada, que mostrou, nos cortes axiais, agenesia do canal carotídeo direito. Tal achado é relatado na literatura, em associação com outras anomalias, como encefaloceles transesfenoidais e aneurismas do polígono de Willis. No presente caso, não foram observadas tais associações. A paciente permaneceu assintomática.
Resumo:
OBJETIVO: Avaliar a profundidade das fossas olfatórias e a freqüência de assimetria na altura e na inclinação lateral do contorno do teto etmoidal. MATERIAIS E MÉTODOS: Estudo retrospectivo de 200 tomografias computadorizadas dos seios da face no plano coronal realizadas no período de agosto a dezembro de 2006. As profundidades das fossas olfatórias foram classificadas segundo Keros. O teto etmoidal foi avaliado quanto à simetria entre os lados. RESULTADOS: O tipo de Keros mais encontrado foi o tipo II (73,3%), seguido do tipo I (26,3%) e do tipo III (0,5%). Em 12% (24 exames) havia assimetria entre os lados quanto à altura do teto etmoidal, e em 48,5% (97 exames) observou-se assimetria do contorno do teto, com inclinação lateral da lâmina crivosa de um dos lados. CONCLUSÃO: Em relação à profundidade das fossas olfatórias, o tipo II de Keros foi o mais freqüente. Verificou-se que a assimetria do teto do seio etmoidal, na maioria dos casos, estava relacionada com a inclinação lateral da lamela lateral da lâmina crivosa.
Resumo:
Objectives: To correlate the chronic stimulated electrode position on postoperative MRI with the clinical response obtained in PD patients. Material and Method: We retrospectively reviewed 14 consecutive parkinsonian patients who were selected for STN-DBS surgery. Coordinates were determined on an IR T2 MRI coronal section per pendicular to AC-PC plane 3 mm posterior to midcommissural point (MCP) and 12 mm lateral to the midline the inferior aspect of subthalamic region. A CRW stereotactic frame was used for the surgical procedure. A 3D IR T2 MRI was performed postoperatively to determine the location of the stimulated contact in each patient. The clinical results were assessed independently by the neurological team. Results: All but 2 patients had monopolar stimulation. The mean coordinates of the stimulated contacts were: AP ^ ÿ4:23G1:4, Lat ^ 1:12G0:15, Vert ^ ÿ4:1 G2:7 to the MCP. With a mean follow-up of 8 months, all stimulated patients had a significant clinical improvement (preop/postop «ON» UPDRS: 25:8G7:0= 23:3 G8:6; preop/postop «OFF» UPDRS: 50:2G11:4=26:0 G7:8), 60% of them without any antiparkinsonian drug. Conclusion: According to the stereotactic atlas of Schaltenbrand and Warren and the 3D shape of the STN, our results show that our targetting is accurate and almost all the stimulated contacts are comprised in the STN volume. This indicates that MRI is a safe, precise and reproducible procedure for targetting the STN. The location of the stimulated contact within the STN volume is a good predictor of the clinical results.