990 resultados para compact dual-band antenna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tool center point calibration is a known problem in industrial robotics. The major focus of academic research is to enhance the accuracy and repeatability of next generation robots. However, operators of currently available robots are working within the limits of the robot´s repeatability and require calibration methods suitable for these basic applications. This study was conducted in association with Stresstech Oy, which provides solutions for manufacturing quality control. Their sensor, based on the Barkhausen noise effect, requires accurate positioning. The accuracy requirement admits a tool center point calibration problem if measurements are executed with an industrial robot. Multiple possibilities are available in the market for automatic tool center point calibration. Manufacturers provide customized calibrators to most robot types and tools. With the handmade sensors and multiple robot types that Stresstech uses, this would require great deal of labor. This thesis introduces a calibration method that is suitable for all robots which have two digital input ports free. It functions with the traditional method of using a light barrier to detect the tool in the robot coordinate system. However, this method utilizes two parallel light barriers to simultaneously measure and detect the center axis of the tool. Rotations about two axes are defined with the center axis. The last rotation about the Z-axis is calculated for tools that have different width of X- and Y-axes. The results indicate that this method is suitable for calibrating the geometric tool center point of a Barkhausen noise sensor. In the repeatability tests, a standard deviation inside robot repeatability was acquired. The Barkhausen noise signal was also evaluated after recalibration and the results indicate correct calibration. However, future studies should be conducted using a more accurate manipulator, since the method employs the robot itself as a measuring device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the framework of the working memory model proposed by A. Baddeley and G. Hitch, a dual-task paradigm has been suggested to evaluate the capacity to perform simultaneously two concurrent tasks. This capacity is assumed to reflect the functioning of the central executive component, which appears to be impaired in patients with dysexecutive syndrome. The present study extends the investigation of an index ("mu"), which is supposed to indicate the capacity of coordination of concurrent auditory digit span and tracking tasks, by testing the influence of training on the performance in the dual task. The presentation of the same digit sequence lists or always-different lists did not differently affect the performance. The span length affected the mu values. The improved performance in the tasks under the dual condition closely resembled the improvement in the single-task performance. So, although training improved performance in the single and dual conditions, especially for the tracking component, the mu values remained stable throughout the sessions when the single tasks were performed first. Conversely, training improved the capacity of dual-task coordination throughout the sessions when dual task was performed first, addressing the issue of the contribution of the within-session practice to the mu index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measure "mu", proposed as an index of the ability to coordinate concurrent box-crossing (BC) and digit-span (DS) tasks in the dual task (DT), should reflect the capacity of the executive component of the working memory system. We investigated the effect of practice in BC and of a change in the digit span on mu by adding previous practice trials in BC and diminishing, maintaining or increasing the digit sequence length. The mu behavior was evaluated throughout three trials of the test. Reported strategies in digit tasks were also analyzed. Subjects with diminished span showed the best performance in DT due to a stable performance in DS and BC in the single- and dual-task conditions. These subjects also showed a more stable performance throughout trials. Subjects with diminished span tended to employ effortless strategies, whereas subjects with increased span employed effort-requiring strategies and showed the lowest means of mu. Subjects with initial practice trials showed the best performance in BC and the most differentiated performance between the single- and dual-task conditions in BC. The correlation coefficient between the mu values obtained in the first and second trials was 0.814 for subjects with diminished span and practice trials in BC. It seems that the within-session practice in BC and the performance variability in DS affect the reliability of the index mu. To control these factors we propose the introduction of previous practice trials in BC and a modification of the current method to determine the digit sequence length. This proposal should contribute to the development of a more reliable method to evaluate the executive capacity of coordination in the dual-task paradigm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kirjallisuusarvostelu

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We measured human frequency response functions for seven angular frequency filters whose test frequencies were centered at 1, 2, 3, 4, 8, 16 or 24 cycles/360º using a supra-threshold summation method. The seven functions of 17 experimental conditions each were measured nine times for five observers. For the arbitrarily selected filter phases, the maximum summation effect occurred at test frequency for filters at 1, 2, 3, 4 and 8 cycles/360º. For both 16 and 24 cycles/360º test frequencies, maximum summation occurred at the lower harmonics. These results allow us to conclude that there are narrow-band angular frequency filters operating somehow in the human visual system either through summation or inhibition of specific frequency ranges. Furthermore, as a general result, it appears that addition of higher angular frequencies to lower ones disturbs low angular frequency perception (i.e., 1, 2, 3 and 4 cycles/360º), whereas addition of lower harmonics to higher ones seems to improve detection of high angular frequency harmonics (i.e., 8, 16 and 24 cycles/360º). Finally, we discuss the possible involvement of coupled radial and angular frequency filters in face perception using an example where narrow-band low angular frequency filters could have a major role.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty micrograms red blood cell (RBC) ghosts from patients who had previously exhibited the cutaneous form of loxoscelism (presenting localized dermonecrosis) and the viscerocutaneous form of loxoscelism (presenting dermonecrosis, hemoglobinuria, hematuria, and jaundice) and from controls were incubated with 2.5 µg crude Loxosceles gaucho venom in 5 mM phosphate buffer, pH 7.4, at 37ºC. Among all membrane proteins, quantitative proteolysis of the important integral transmembrane protein 3 increased with venom dose and with incubation time from 30 to 120 min, as demonstrated by gel densitometry. Similar quantitative data were obtained for RBC ghosts from patients and from control subjects, a fact that argues against the possibility of genetic factors favoring the hemolytic viscerocutaneous form. These data suggest that the clinical forms may be different types of the same disease, with the viscerocutaneous form being the result of large amounts of intravascularly injected venom and the superficial form being the result of in situ venom action. Since protein 3 is a housekeeping integral membrane protein, whose genetic deficiency leads to hemolytic anemia, it is reasonable to relate it to the hemolysis which occurs in the viscerocutaneous form of loxoscelism. The venom protease responsible for the process was not inhibited after 120-min incubation by 0.2 mM paramethylsulfonyl fluoride or by 0.2 mM N-ethylmaleimide but was inhibited by 25 mM ethylenediaminetetraacetic acid (a calcium-chelating agent) in 5 mM phosphate buffer at pH 7.4, which suggests that the enzyme is a calcium-dependent metalloprotease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54) or infrared coagulation (N = 46). Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years). The mean duration of disease was 17.5 months (range 12 to 34 months). The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale). Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059). The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03), but also had a higher recurrence or failure rate (P = 0.03). Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study proposes to apply magnitude-squared coherence (MSC) to the somatosensory evoked potential for identifying the maximum driving response band. EEG signals, leads [Fpz'-Cz'] and [C3'-C4'], were collected from two groups of normal volunteers, stimulated at the rate of 4.91 (G1: 26 volunteers) and 5.13 Hz (G2: 18 volunteers). About 1400 stimuli were applied to the right tibial nerve at the motor threshold level. After applying the anti-aliasing filter, the signals were digitized and then further low-pass filtered (200 Hz, 6th order Butterworth and zero-phase). Based on the rejection of the null hypothesis of response absence (MSC(f) > 0.0060 with 500 epochs and the level of significance set at a = 0.05), the beta and gamma bands, 15-66 Hz, were identified as the maximum driving response band. Taking both leads together ("logical-OR detector", with a false-alarm rate of a = 0.05, and hence a = 0.0253 for each derivation), the detection exceeded 70% for all multiples of the stimulation frequency within this range. Similar performance was achieved for MSC of both leads but at 15, 25, 35, and 40 Hz. Moreover, the response was detected in [C3'-C4'] at 35.9 Hz and in [Fpz'-Cz'] at 46.2 Hz for all members of G2. Using the "logical-OR detector" procedure, the response was detected at the 7th multiple of the stimulation frequency for the series as a whole (considering both groups). Based on these findings, the MSC technique may be used for monitoring purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is about development broadband feed for two-mirror antenna system that match following requirements: beamwidth from 45 to 90 degrees at -3 dB level, circular polarization, absence of radiation to the lower hemisphere area. Literature review was done in the areas of the UWB antennas creation. During the work attempts were made to create a feed in a form of the quad ridged horn and "eleven" antennas. The latter is introduced as the most effective feed among all antennas discussed in thesis. Radiation patterns and other results for "eleven" antenna were obtained. Results were saved as far field sources and placed slightly below focal point into the two-mirror antenna system, because phase center of the “eleven” antenna is predominantly shifted upwards. Directivity patterns for the two-mirror system were obtained and the conclusions about the work results have been made

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The removal of organics from copper electrolyte solutions after solvent extraction by dual media filtration is one of the most efficient ways to ensure the clean electrolyte flow into the electrowinning. The clean electrolyte will ensure the good quality cathode plate production. Dual media filtration uses two layers of filter media for filtration as anthracite and garnet respectively. The anthracite layer will help the coalescing of the entrained organic droplets which will then float to the top of the filter, and back to the solvent extraction process. The garnet layer will catch any solids left in the electrolyte traveling through the filter media. This thesis will concentrate on characterization of five different anthracites in order to find some differences using specific surface area analysis, particle size analysis, and morphology analysis. These results are compared to the pressure loss values obtained from lab column tests and bed expansion behavior. The goal of the thesis was to find out if there were any differences in the anthracite which would make the one perform better than the other. There were no big differences found on any aspect of the particle characterization, but some found differences should be further studied in order to confirm the meaning of the porosity, surface area, intensity mean and intensity SD (Standard Deviation) on anthracites and their use in dual media filtration. The thesis work analyzed anthracite samples the way that is not found on any public literature sources, and further studies on the issue would bring more knowledge to the electrolyte process.