1000 resultados para análise química da terra
Resumo:
A on-line thermostatization system that use simples materials, for flow injection and continuous flow analysis is described. The proposed system showed good performance between 10 to 40ºC.
Resumo:
Four naphthoquinones, lapachol, a-lapachone, dehydro-a-lapachone and 4-hydroxy-a-lapachone were isolated from the ethanol extract of Zeyheria montana M. roots (Bignoniaceae) and were identified by spectroscopic methods. These naphthoquinones, except 4-hydroxy-a-lapachone, were quantified by HPLC, in the crude ethanol extracts of Z. montana roots. The separation of lapachol, a-lapachone and dehydro-a-lapachone was achieved and these compounds were identified in the chromatograms by their retention times and by their on line UV-spectra. The quantification of the three naphthoquinones, in four different samples showed medium contents of 11,0 mg of lapachol, 6,1 mg of a-lapachone and 4,3 mg of dehydro-a-lapachone, in 100 mg of Z.montana roots.
Resumo:
An on-line electrodissolution procedure implemented in a flow injection system for determination of copper, zinc and lead in brasses alloys by ICP-AES is described. Sample dissolution procedure was carried out by using a PTFE chamber and a DC power supply with constant current. Solid sample was attached to chamber as anode and a gold tubing coupled in the chamber was used as cathode. An electrolytic solution flowing through the gold tubing closed the electric circuit with sample, in order to provide condition for electric dissolution when the DC power supply was switched on. The best results were achieved by using a 1.5 mol l-1 nitric acid solution as electrolyte and a 2.5 A current intensity. The procedure presented a good performance characterized by a relative standard deviation better than < 5% (n=5) and a sample throughput of 180 determinations per hour for Cu, Zn and Pb. Results were in agreement with those obtained by conventional acid dissolution (99% confidence level).
Resumo:
The infrared (IR) spectra of the four distict conformers located on the multidimensional potential energy surface (PES) for the 3-phenyl-1,2,3-oxathiazolidine 2-oxide compound have been calculated using the semiempirical quantum-mechanical method PM3. The band spectra are reported and compared directly with the experimental spectrum. The IR intensities are shown to be much more sensitive to conformational changes than the vibrational frequencies and so, the theoretical analysis of the IR spectrum can be used as a tool for helping in the elucidation of the structure of heterocyclic compounds.
Análise de cabelo: uma revisão dos procedimentos para a determinação de elementos traço e aplicações
Resumo:
Aspects related to the quality of human hair analysis are presented, such as sample collection, sample preparation, determination of trace elements and application examples. Also the hair morphology, the importance of this analysis and its uses and meanings are discussed.
Resumo:
This review presents the evolution of simultaneous multicomponent analysis by absorption spectrophotometry in the ultraviolet and visual regions in terms of some qualitative and quantitative analysis techniques, otimization methods, as well as applications and modern trends.
Resumo:
Little is known about the amount of water and ash in brazilian foodstuffs and plants. The relationships between fresh, dry and ash weight were determined in 40 different biological samples. It could be an important tool when one studies biological material containing low concentration of the chemical elements. This study address to determine these relationships and to provide the amount of biological material that one needs to collect. It aims to supply information that could be used to improve the detection limit, precision and accuracy of the analytical methodology utilized.
Resumo:
This work discusses sample preparation processes for gas chromatography (GC) based on the technique of extraction through membrane permeation (MPE). The MPE technique may be easily coupled to GC via a relatively simple device, which is a module that holds the membrane and is directly connected to the GC column. The possibility of operational errors due to sample handling is substantially reduced in an MPE-GC system because the sample preparation and the chemical analysis are accomplished as a one-step process. The MPE technique is of relatively wide application as it can be used for aqueous samples, solid samples and gaseous samples. Depending on the type of sample the extraction is performed with the membrane in direct contact with the sample or in contact with its headspace. The MPE-GC technique is very useful in trace analysis, due to the time-dependent enrichment of the analyte. A typical application of MPE-GC is the analysis of VOCs present in water that may be accomplished with detection limits at the low ppb (mugL-1) level.
Resumo:
Didactic experiments are proposed in order to demonstrate the characteristics of flow injection analysis and to extend the applications of FIA to the determination of physical chemistry parameters in undergraduate labs. All experiments can be performed with the same flow manifold by employing usual FIA devices. Analytical characteristics are presented by means of the determination of iron in river water, employing 1,10-phenantroline as chromogenic reagent. Physical chemistry applications were the determination of reaction stoichiometries by continuous variation and mole-ratio methods and the evaluation of the pH and ionic strength effects on the kinetic of the reduction of hexacianoferrate(III) by ascorbic acid.
Resumo:
One of the major interests in soil analysis is the evaluation of its chemical, physical and biological parameters, which are indicators of soil quality (the most important is the organic matter). Besides there is a great interest in the study of humic substances and on the assessment of pollutants, such as pesticides and heavy metals, in soils. Chemometrics is a powerful tool to deal with these problems and can help soil researchers to extract much more information from their data. In spite of this, the presence of these kinds of strategies in the literature has obtained projection only recently. The utilization of chemometric methods in soil analysis is evaluated in this article. The applications will be divided in four parts (with emphasis in the first two): (i) descriptive and exploratory methods based on Principal Component Analysis (PCA); (ii) multivariate calibration methods (MLR, PCR and PLS); (iii) methods such as Evolving Factor Analysis and SIMPLISMA; and (iv) artificial intelligence methods, such as Artificial Neural Networks.
Resumo:
The objective of this study was to evaluate a flow injection system for determination of residual CO3(2-) in soil amended with lime material. It was used a closed system were the CO2 released from soil sample acidified with 0.5 mol L-1 HCl was capted in a 0.2 mol L-1 NaOH solution. After 16h the capted CO2 was determined by conductivimetry using a flow injection system. The results obtained by the proposed method were significantly correlated with those reported in soil samples used by the International Soil Analytical Exchange Programe. The regression equation was: y = 0.987x -- 0.075 r = 0.996, P > 0.01. For acid soils amended with CaCO3 the method showed a deviation error of 2.7%, detection limit was 0.077 mmol kg-1 of CO3(2-), and a recovery of 99.7% of the total CO3(2-) added in soil sample. The method was easily adapted for routine determination of residual CO3(2-) in soil samples with an analytical frequency of 40 samples per hour.
Resumo:
Independent of the sample form (powder or film), XRD analysis of Ir0,3Ti(0,7-x)Ce xO2, (nominal) mixtures, for x=0, shows the formation of a solid solution phase between IrO2 and TiO2, as well as the rutile phases of IrO2 and TiO2. The presence of the anatase phase of TiO2 is also confirmed. The introduction of 30 mol% CeO2 in the mixture reveals the presence of the CeO2 and Ce2O3 phases, besides the already mentioned ones, in the powder. In the film form, however, an amorphous phase is identified. When all of the TiO2 is substituded by CeO2, for both sample forms, the only phases found are IrO2, CeO2 and Ce2O3. This result suggests cerium oxides are not capable of forming solid solutions with either IrO2 or (Ir,Ti)O2 acting solely as a dispersant matrix for these phases. These results are consistent with the much higher electrochemically active surface area when CeO2 is introduced in the binary Ti/Ir0,3Ti0,7O2 mixture. It was possible to establish a relationship between the electrochemical stability of the supported films and their crystalline structure. The unexpected presence of TiO2 and Ti2O3 in the Ti/Ir0,3Ce0,7O2 (film sample) is attributed to oxidation of the Ti support during the calcination step.
Resumo:
The field of flow injection potentiometry (FIP) is reviewed and its current status assessed. The research development and application of electrodes in flow injection systems are presented and discussed.
Resumo:
Analysis of alcohols, esters and carbonyl compounds were performed using HRGC and HPLC techniques in samples of fusel oils from three different Brazilian alcohol distilleries. High content of isoamyl alcohol (390 g.L-1), isobutyl alcohol (158 g.L-1), ethyl alcohol (28,4 g.L-1), methyl alcohol (16,6 g.L-1) and n-propyl alcohol (11,9 g.L-1) were found. These compounds represent 77 ± 8 % of the approximated weight of a liter of fusel oils. The obtained results show the feasibility of using fusel oils as low-cost raw material for the synthesis of chemicals.
Resumo:
A preliminary analyses of the possible contamination of superficial and underground water by the active ingredients of the pesticide products used in the surroundings of the urban area of Primavera do Leste, Mato Grosso, Brazil, was carried out. A description of the study region and of its environmental characteristics, which can favor the contamination of the local aquatic environment, was presented. The EPA screening criteria, the groundwater ubiquity score (GUS) and the criteria proposed by Goss were used to evaluate which pesticides might contaminate the local waters. Among the active ingredients studied, several present risks to the local aquatic environment.