723 resultados para aluminium casting alloys
Resumo:
STATEMENT OF PROBLEM: AuTi alloys with 1.6% to 1.7% (wt%) Ti provide sufficient bond strength to veneering ceramics, but the strength of entire metal-ceramic restorations fabricated from these alloys is not known. However, this information is important to assess the clinical performance of such materials. PURPOSE: This in vitro study evaluated the fracture strength and thermal shock resistance of metal-ceramic crowns with AuTi frameworks produced by milling or casting. MATERIAL AND METHODS: Frameworks of the alloy Au-1.7Ti-0.1Ir (wt%) (Esteticor Vision) were produced by milling or casting (test groups). A high-gold alloy (Esteticor Special) was used as the control. The frameworks were veneered with ceramic (VMK 95). Specimens (n=7) were loaded until fracture. Loads at failure (N) were recorded and the mean values statistically evaluated using 1-way analysis of variance and a post hoc Dunnett test (alpha=.05). To assess the crazing resistance of the veneering ceramic, 6 additional crowns of each group were subjected to a thermal shock test. Fractured surfaces were documented by scanning electron microscopy. Coefficients of thermal expansion of the materials used were measured (n=2) to assess the thermal compatibility between alloys and ceramic. RESULTS: The mean fracture strength of the crowns with machined AuTi frameworks (1294 +/- 236 N) was significantly lower (P=.012) than that of the cast AuTi frameworks (1680 +/- 150 N), but statistically not different than the high-gold alloy (1449 +/- 159 N). Bonding failure to the AuTi alloy predominantly occurred at the alloy-oxide interface. For the high-gold alloy, more ceramic residues were observed. In the thermal shock test, crowns with milled AuTi frameworks showed significantly higher thermal shock resistance compared to the other groups. The coefficients of thermal expansion (Esteticor Vision cast: 14.5 microm/m.K; Esteticor Vision milled: 14.3 microm/m.K; Esteticor Special cast: 13.7 microm/m.K) did not correlate with the results of the thermal shock test. CONCLUSION: The in vitro fracture strength of crowns with milled AuTi frameworks is lower than that obtained with cast AuTi frameworks, but comparable to those crowns produced with a high-gold alloy.
Resumo:
Objective: To assess in vitro the bond strength of a machined surface of a Au-Ti alloy to a veneering ceramic. Method and Materials: Metal strips of the alloy Au 1.7-Ti 0.1-Ir were milled from a semiproduct fabricated by continuous casting and cold forming. For comparison, the same alloy as well as a traditional Au-Pt-Pd-In alloy were used in the as-cast state. Six samples of each group were fabricated for the crack initiation test, according to ISO 9693:1999, by preparing appropriate metal strips that were veneered with ceramic using a standard firing procedure. The crack initiation test was performed in a universal testing machine. Load at fracture was recorded. Means of bond strength were calculated for each group and the results compared by use of a 1-sided Student t test (P < .05). Fracture sites were documented by means of SEM. Results: Bond strength in the 3 groups was in the same order of magnitude. Failure mode was different for both alloys. Failure of the bonding to the Au-Ti alloy predominantly occurred at the alloy-oxide interface, no matter which fabrication process was used. On the Au-Pt-Pd-In alloy, more ceramic residues were observed. Conclusion: The machined alloy Au 1.7-Ti 0.1-Ir provides sufficient bond strength to veneering ceramics, but this has to be proven by a clinical study. (Quintessence Int 2007;38:867-872).
Resumo:
Different types of titanium-alloys instead of CoCr-alloys have been tested as material for the framework of removable partial dentures (RPD). Adequate casting and processing techniques have been developed which enable to fabricate frameworks of complex designs and the problem limits porosity. This opened new possibilities for the use of titanium-alloys with improved properties (E-module). The aim of this study was to summarise the use of titanium in removable prosthodontics and to evaluate prospectively the use of the Ti6A17Nb-alloy for RPDs in a small group of patients. Two identically designed RPDs from CoCr-alloy (remanium GM 800+) and Ti6A17Nb-alloy (girotan L) were produced for ten patients. They had to wear each RPD during six months, first the CoCr-RPD and then the Ti6A17Nb-RPD. A questionnaire (visual analogue scale = VAS) was completed by the patients after one, three and six months of function for each RPD. Prosthetic complications and service needed were recorded. After the end of the entire observation period of twelve months, the patients remained with the Ti6A17Nb-RPD and answered the questionnaire after another six months. All parameters regarding the design of the RPDs were positively estimated by the dentist. Minimal, not significant differences were noted by the patients concerning comfort, stability and retention (VAS). Clinically, no differences in technical aspects or regarding biological complications were observed after six-months periods. The Ti6A17Nb-alloy (girotan L) for the framework of RPDs was judged by patients and professionals to be equivalent to RPDs made from CoCr-alloy. No differences in material aspects could objectively be observed. The Ti6A17Nb-alloy can be beneficial for patients with allergies or incompatibility with one or several components of the CoCr-alloy.
Resumo:
It is known that the electrical resistance of annealed metals is usually smaller than that of metals in their cold worked state. The curve showing the relation between electrical resistance and annealing temperature reaches a minimum; continued annealing at higher temperature produces an increase in the electrical resistance. In the case of alloys it has been noted that a second decrease occurs at higher annealing temperature. The following work corroborates the observance of previous investigations. The electrical resistance of cold worked copper, gold, nickel, and iron decreased with annealing and then increased, the minimum being around 300° C. or 400° C. Monel metal showed a minimum resistance followed by an increase which in turn was followed by a second decrease.
Resumo:
This paper presents some experimental data on the size and position of pipes steel ingots as exemp1ified by casting wax under various conditions and noting the size and location of the pipes formed. The results tend to show that the length of the pipe is decreased by: 1. Slow casting 2. By casting large end up instead of down 3. By retarding the cooling of the top
Resumo:
In order to determine the best annealing temperature at which to age-harden the alloys, hardness tests on specimen annealed for different lengths of time at different temperatures were made.
Resumo:
Prior to the last few years little practical use was made of the element tellurium, which is obtained from gold and silver tellurides and from the slimes of electrolytic copper refineries. Lately, however, more study has been made of its properties when alloyed with other metals. It was the purpose of this thesis to study the effects of the addition of tellurium to lead, particularly in small amounts.
Resumo:
Although there is no standardized list of alloys, most investigators have, to avoid confusion, concurred in at least grouping the metals under several general heads. Precious metals: gold, silver and the platinum group; the light metals: aluminum and magnesium; the non-ferrous metals (excluding all steels and iron-base alloys); and the antifriction metals.
Resumo:
Among the many aluminum alloys which have been studied are the binary copper-aluminum alloys. These have proven to be among the most useful of the aluminum alloys thus far worked upon.
Resumo:
The alloy system selected for study was the binary alloy of platinum and silver. An examination of the various silver alloy diagrams revealed that of several possible alloys, the silver platinum was the most suitable with regard to solubility.
Some Preliminary Investiagtions of the Magnetic Permeabilities of Alloys of the Ferromagnetic Metals
Resumo:
The problem presented for this thesis was an investigation of the magnetic properties of the alloys produced by the methods of powder metallurgy. The question behind this was the correlation of the magnetic properties with the bonding properties and with the diffusion of the constituents.
Resumo:
An attempt was made to make lead-lithium alloys by electrodeposition of lithium using a molten bath and a molten lead cathode.The variables taken into consideration were: composition of the melt, temperature of the melt, and current density. The purpose of changing these factors was to determine what effect each had on the current efficiency.
Resumo:
From the standpoint of its practical usefulness, the most important characteristics of metallic lead are its cheapness, resistance to corrosion, plasticity, high specific gravity, low melting point, and its ability to form alloys in which some properties are modified by the addition of other elements, while other properties remain the same.
Resumo:
Various electrolytes were experimented with in an attempt to deposit an iron-manganese alloy. An Alloy was obtained from a solution containing ferrous ammonium sulfate, manganous sulfate, and ammonium sulfate. Further experimentation was done in an effort to determine the optimum conditions of deposition and the highest manganese alloy which could be produced.