994 resultados para Waste valorization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Waste produced during the service life of automobiles has received much less attention than end-of-life vehicles themselves. In this paper, we deal with the set up of a reverse logistics system for the collection and treatment of use-phase residues. First, the type of waste arising during vehicles? service life is characterized. Data were collected in collaboration with SIGRAUTO, the product stewardship organization in charge of vehicles? recovery in Spain. Next, three organizational models are proposed. The three alternatives are benchmarked and assessed from a double organizational and operational perspective for the particular case of the Madrid region in Spain

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquaponics is the science of integrating intensive fish aquaculture with plant production in recirculating water systems. Although ion waste production by fish cannot satisfy all plant requirements, less is known about the relationship between total feed provided for fish and the production of milliequivalents (mEq) of different macronutrients for plants, especially for nutrient flow hydroponics used for strawberry production in Spain. That knowledge is essential to consider the amount of macronutrients available in aquaculture systems so that farmers can estimate how much nutrient needs to be supplemented in the waste water from fish, to produce viable plant growth. In the present experiment, tilapia (Oreochromis niloticus L.) were grown in a small-scale recirculating system at two different densities while growth and feed consumption were noted every week for five weeks. At the same time points, water samples were taken to measure pH, EC25, HCO3 – , Cl – , NH4 + , NO2 – , NO3 – , H2PO4 – , SO4 2– , Na + , K+ , Ca 2+ and Mg 2+ build up. The total increase in mEq of each ion per kg of feed provided to the fish was highest for NO3 - , followed, in decreasing order, by Ca 2+ , H2PO4 – , K+ , Mg 2+ and SO4 2– . The total amount of feed required per mEq ranged from 1.61- 13.1 kg for the four most abundant ions (NO3 – , Ca 2+ , H2PO4 – and K+ ) at a density of 2 kg fish m–3 , suggesting that it would be rather easy to maintain small populations of fish to reduce the cost of hydroponic solution supplementation for strawberries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this research is to study the feasibility of recycling fibres from construction and demolition waste (C&DW) as an alternative material to chopped glass fibres which are used today as reinforcing elements in the prefabricated plaster. To do this, sets of samples are made with rockwool and different percentages of combinations between water / plaster. These series are repeated by changing the additive E glass fibre length of 25mm to make a comparative analysis with respect to the series infused with rockwool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of mineral wool is becoming more widespread due to increased acoustic and thermal demands of Spanish Technical Building Code. This increase affects both in rehabilitation and new construction projects. Therefore, waste generation of this type of insulating material is having more importance. The main objective of this research is to study the possibility of recycling fiber obtained from mineral wool of the C&DW as an alternative material to chopped glass fibers that are currently used as reinforcing elements in the prefabricated plaster. To achieve this objective, series are made of plaster E-35 additived with rock wool residue and glass wool residue at different rates of addition. These series are repeated by changing the additive by E fiberglass (length of 25mm) to make a comparative analysis with respect to the series additived with mineral wool waste. All the series are subjected to the test to determine Shore C surface hardness and mechanical testing to determine the compressive and flexural strength. From the results it can be concluded that: with rock wool residue, increases Shore C hardness up to 15% with respect to the glass fiber and 9% with respect to the glass wool, with a percentage of addition 2%. With rock wool residue, weight is decreased by 5% with respect to the glass fiber and 4% with respect to the glass wool waste, with an addition percentage of 4%. For an addition rate of 4%, results in the flexural strength test with fiberglass are 85% higher than those obtained with glass wool residue. However, for a percentage of 1% addition, the results obtained with glass wool residue are 35% higher than those obtained with fiberglass. For an addition rate of 3% results in the compressive strength test with fiberglass are 54% lower than those obtained with rock wool waste and 70% lower than those obtained with glass wool waste. Comparing the two mineral wools, it can be concluded that up to 3% of the addition, the glass wool series results obtained are 10% higher than those additived with rock wool. However, higher percentages of addition show that the results obtained with rock wool are 35% higher than those obtained with glass wool. The general conclusion is that the series additived with mineral wool from C&DW show better results in tests than the ones used nowadays as plaster reinforcement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The difficulty of dealing with construction and demolition waste (CDW) on construction sites is not new and continues to be a significant environmental problem. Currently the CDW collection system in Spain is done in a decentralized manner by each sub-contracted company, being necessary to implement effective waste management measures ensuring a correct management and minimization. During the last years several measures have been launched in order to improve and encourage the reuse and recycling of CDW. A widespread solution for CDW recovery is using them as a landscaping aggregate or for road bases and sub-bases. However, measures encouraging onsite prevention still need to be enhanced. This paper studies the major work stage generating CDW and analyses the categories of CDW produced during its execution. For this, several real building sites have been analysed in order to quantify the estimation of CDW generated. Results of this study show that a significant contributor to the CDW generation on building construction sites in Spain are the masonry works. Finally, a Best Practices Manual (BPM) is proposed containing several strategies on masonry works aimed not only at CDW prevention, but also at improving their management and minimization. The use of this BPM together with the Study and Plan of CDW management --required by law--, promotes the environmental management of the company, favouring the cohesion of the construction process organization at all stages giving rise to establishing responsibilities in the field of waste and providing a greater control over the process. Keywords: construction and demolition waste, management, masonry works, good practice measures, prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New European directives have proposed the direct application of compost and digestate produced from municipal solid wastes as organic matter sources in agricultural soils. Therefore information about phosphorus leaching from these residues when they are applied to the soil is increasingly mportant. Leaching experiments were conducted to determine the P mobility in compost and digestate mixtures, supplying equivalent amounts to 100 kg P ha?1 to three different types of soils. The tests were performed in accordance with CEN/TS 14405:2004 analyzing the maximum dissolved reactive P and the kinetic rate in the leachate. P biowaste fractionation indicated that digestate has a higher level of available P than compost has. In contrast, P losses in leaching experiments with soil-compost mixtureswere higher than in soil-digestate mixtures. For bothwastes, therewas no correlation between disolved reactive P lost and the water soluble P.The interaction between soil and waste, the long experimentation time, and the volume of leachate obtained caused the waste?s wettability to become an influential parameter in P leaching behavior. The overall conclusion is that kinetic data analysis provides valuable information concerning the sorption mechanism that can be used for predicting the large-scale behavior of soil systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Spain, large quantities of wine are produced every year (3,339,700 tonnes in 2011) (FAO, 2011) with the consequent waste generation. During the winemaking process, solid residues like grape stalks are generated, as well as grape marc and wine lees as by-products. According to the Council Regulation (EC) 1493/1999 on the common organization of the wine market, by-products coming from the winery industry must be sent to alcohol-distilleries to generate exhausted grape marc and vinasses. With an adequate composting treatment, these wastes can be applied to soils as a source of nutrients and organic matter. A three-year field experiment (2011, 2012 and 2013) was carried out in Ciudad Real (central Spain) to study the effects of wine-distillery waste compost application in a melon crop (Cucumis melo L.). Melon crop has been traditionally cultivated in this area with high inputs of water and fertilizers, but no antecedents of application of winery wastes are known. In a randomized complete block design, four treatments were compared: three compost doses consisted of 6.7 (D1), 13.3 (D2) and 20 t compost ha-1 (D3), and a control treatment without compost addition (D0). The soil was a shallow sandy-loam (Petrocalcic Palexeralfs) with a depth of 0.60 m and a discontinuous petrocalcic horizon between 0.60 and 0.70 m, slightly basic (pH 8.4), poor in organic matter (0.24%), rich in potassium (410 ppm) and with a medium level of phosphorus (22.1 ppm). During each growing period four harvests were carried out and total and marketable yield (fruits weighting <1 kg or visually rotten were not considered), fruit average weight and fruit number per plant were determined. At the end of the crop cycle, four plants per treatment were sampled and the nutrient content (N, P and K) was determined. Soil samplings (0-30 cm depth) were carried before the application of compost and at the end of each growing season and available N and P, as well as exchangeable K content were analyzed. With this information, an integrated analysis was carried out with the aim to evaluate the suitability of this compost as organic amendment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulphur compounds remaining in petroleum fractions from topping, hydroskimming or deep conversion processes are a growing concern for oil refiners since in the lapse of a few years the sulphur specification for motor fuels has dropped from 500 mg/kg to 10 mg/kg in most European countries. This increasingly stringent regulation has forced refineries to greatly improve their hydrodesulfurization units, increasing the desulfurization rates and thus consuming huge amounts of hydrogen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tesis presenta los resultados de la investigación realizada sobre la inertización de cenizas volantes procedentes de residuos sólidos urbanos y su posterior encapsulación en distintas matrices de mortero. Durante el proceso de inertización, se ha logrado la inertización de éste residuo tóxico y peligroso (RTP) y también su valorización como subproducto. De esta forma se dispone de nueva “materia prima” a bajo coste y la eliminación de un residuo tóxico y peligroso con la consiguiente conservación de recursos naturales alternativos. La caracterización química de las cenizas analizadas refleja que éstas presentan altas concentraciones de cloruros, Zn y Pb. Durante la investigación se ha desarrollado un proceso de inertización de las cenizas volantes con bicarbonato sódico (NaHCO3) que reduce en un 99% el contenido en cloruros y mantiene el pH en valores óptimos para que la concentración de los metales pesados en el lixiviado sea mínima debido a su estabilización en forma de carbonatos insolubles. Se han elaborado morteros con cuatro tipos distintos de cementos (CEM-I, CEM-II, CAC y CSA) incorporando cenizas volantes inertizadas en una proporción igual a un 10% en peso del árido utilizado. Los morteros ensayados abarcan distintas dosificaciones tanto en la utilización de áridos con distintos diámetros (0/2 y 0/4), como en la relación cemento/árido (1/1 y 1/3). Se han obtenido las propiedades físicas y mecánicas de estos morteros mediante ensayos de Trabajabilidad, Estabilidad Dimensional, Carbonatación, Porosidad y Resistencias Mecánicas. De igual forma, se presentan resultados de ensayos de lixiviación de Zn, Pb, Cu y Cd, sobre probetas monolíticas de los morteros con los mejores comportamientos físico/mecánicos, donde se ha analizado el contenido en iones de dichos metales pesados lixiviados mediante determinación voltamperométrica de redisolución anódica Se concluye que todos los morteros ensayados son técnicamente aceptables, siendo los más favorables los elaborados con Cemento de Sulfoaluminato de Calcio (CSA) y con Cemento de Aluminato de Calcio (CAC). En este último caso, se mejoran las resistencias a compresión de los morteros de referencia en más de un 48%, y las resistencias a flexión en más de un 67%. De igual forma, los ensayos de lixiviado revelan la completa encapsulación de los iones de Zn y la mitigación en el lixiviado de los iones de Pb. Ambos morteros podrían ser perfectamente validos en actuaciones en las que se necesitase un producto de fraguado rápido, altas resistencias iniciales y compensación de las retracciones con una elevada estabilidad dimensional. En base a esto, el material podría ser utilizado como mortero de reparación en viales y pavimentos que requiriesen altas prestaciones, tales como: soleras industriales, pistas de aterrizaje, aparcamientos, etc. O bien, para la confección de elementos prefabricados sin armaduras estructurales, dada su elevada resistencia a flexión. ABSTRACT This dissertation presents the results of a research on inerting fly ash from urban solid waste and its subsequent encapsulation in mortar matrixes. The inerting of this hazardous toxic waste, as well as its valorization as a by-product has been achieved. In this way, a new "raw material" is available through a simple process and the toxic and hazardous waste is eliminated, and consequently, conservation of alternative natural resources is strengthened. Chemical analysis of the ashes analyzed shows high concentrations of soluble chlorides, Zn and Pb. An inerting process of fly ash with sodium bicarbonate (NaHCO3) has been developed which reduces 99% the content of chlorides and maintains pH at optimal values, so that the concentration of heavy metals in the leachate is minimum, due to its stabilization in the form of insoluble carbonates. Mortars with four different types of cements (CEM-I, CEM-II, CAC and CSA) have been developed by the addition of inertized fly ash in the form of carbonates, in the proportion of 10% in weight of the aggregates used. The samples tested include different proportions in the use of aggregates with different sizes (0/2 and 0/4), and in the cement/aggregate ratio (1/1 and 1/3). Physical/mechanical properties of these mortars have been studied through workability, dimensional stability, carbonation, porosity and mechanic strength tests. Leaching tests of Zn, Pb, Cu and Cd ions are also being performed on monolithic samples of the best behavioral mortars. The content in leachated heavy metal ions is being analyzed through stripping voltammetry determination. Conclusions drawn are that the tested CAC and CSA cement mortars present much better behavior than those of CEM-I and CEM-II cement. The results are especially remarkable for the CAC cement mortars, improving reference mortars compression strengths in more than 48%, and also bending strengths in more than 67%. Leaching tests confirm that the encapsulation of Zn and Pb is achieved and leachate of both ions is mitigated within the mortar matrixes. For the above stated reasons, it might be concluded that mortars made with calcium aluminate cements or calcium sulfoaluminate with the incorporation of treated fly ash, may be perfectly valid for uses in which a fast-curing product, with high initial strength and drying shrinkage compensation with a high dimensional stability is required. Based on this, the material could be used as repair mortar for structures, roads and industrial pavements requiring high performance, such as: industrial floorings, landing tracks, parking lots, etc. Alternatively, it could also be used in the manufacture of prefabricated elements without structural reinforcement, given its high bending strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En un mundo altamente urbanizado, la gestión de residuos sólidos es un problema primordial en toda ciudad. Las ciudades de paises en desarrollo deben además afrontar retos que no afectan a las ciudades de paises desarrollados. En los paises en desarrollo muchas municipalidades sufren un crecimiento descontrolado de los asentamientos informales sin planificación urbana que hace muy complicada una adecuada gestión de los residuos sólidos urbanos, situación que se agrava al no contar estas con suficientes recursos económicos para llevar a cabo su responsabilidad en cuanto a provisión del sevicio básico de recogida de residuos. La provisión de servicio de recogida de residuos por parte de SHGs (grupos de ayuda comunitarios) en estos asentamientos informales puede ayudar a resolver algunos de estos problemas. Para que esta oportunidad sea completamente explotada, los ingresos de estos grupos deben ser garantizados, teniendo en cuenta que la sostenibilidad de estos grupos depende enteramente de ello. Este estudio pretende averiguar cómo un enfoque de cadena de valor puede mejorar la sostenibilidad de la gestión de residuos sólidos, permitiendo asegurar los ingresos de los recolectores informales de residuos. El estudio propondrá después de analizado el actual sistema, mejoras que permitan desarrollar un medio ambiente saludable en los asentamientos informales donde se desarrolla el estudio. Para alcanzar este objetivo, se ha desarrollado una investigación específica en Nairobi (Kenia) en el asentamiento precario de Mukuru Kwa Njenga, analizando los distintos aspectos relevantes que tienen influencia en una gestión integrada de residuos sólidos y las relaciones entre los distintos actores que tienen influencia en la misma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biochar is a carbon-rich solid obtained by the thermal decomposition of organic matter under a limited supply of oxygen and at relatively low temperatures. Biochar can be prepared from the pyrolysis of different organic feed- stocks, such as wood and biomass crops, agricultural by-products, different types of waste or paper industry waste materials . The pyrolysis procedure of waste, i.e. sewage sludge, has mainly two advantages, firstly, it removes pathogens from waste and, secondly, biochar can reduce the leaching of heavy metals present in raw sewage sludge. This trend of the use of waste material as feedstocks to the preparation of biochar is increasing in the last years due to industrial development and economic growth imply an increase in waste generation. The application of biochar may have positive effects on soil physical properties as water holding capacity and structure or on soil biological activity and soil quality. Also, biochar can be used to remove water pollutants and can be used in multiple ways in soil remediation due to its adsorption of pesticides or metals. Also, biochar contribute to carbon sequestration due to carbon stability of biochar materials. The objective of this presentation is to review the positive effects of the biochar prepared from organic waste on soil properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current EU Directives force the Member States to assure by 2020 that 70% of the Construction and Demolition (C&D) waste is recovered instead of landfilled. While some countries have largely achieved this target, others still have a long way to go. For better understanding the differences arising from local disparities, six factors related to technical, economic, legislative and environmental aspects have been identified as crucial influences in the market share of C&D waste recycling solutions. These factors are able to identify the causes that limit the recycling rate of a certain region. Moreover, progress towards an efficient waste management can vary through the improvement of a single factor. This study provides the background for further fine-tuning the factors and their combination into a mathematical model for assessing the market share of C&D recycling solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La edificación residencial existente en España y en Europa se encuentra abocada a una rehabilitación profunda para cumplir los objetivos marcados en la estrategia europea para el año 2050. Estos, para el sector de la edificación, se proponen una reducción del 90% de emisiones de gases de efecto invernadero (GEI) respecto a niveles del año 1990. Este plan a largo plazo establece hitos intermedios de control, con objetivos parciales para el año 2020 y 2030. El objetivo último es aprovechar el potencial de reducción de demanda energética del sector de la edificación, del cual la edificación residencial supone el 85% en España. Dentro de estos requerimientos, de reducción de demanda energética en la edificación, la ventilación en la edificación residencial se convierte en uno de los retos a resolver por su vinculación directa a la salud y el confort de los ocupantes de la misma, y al mismo tiempo su relación proporcional con la demanda energética que presenta el edificio asociada al acondicionamiento térmico. Gran parte de las pérdidas térmicas de la edificación residencial se producen por el aire de renovación y la infiltración de aire a través de la envolvente. La directiva europea de eficiencia energética de la edificación (EPBD), que establece las directrices necesarias para alcanzar los objetivos de este sector en cuanto a emisiones de CO2 y gases de efecto invernadero (GEI), contempla la ventilación con aire limpio como un requisito fundamental a tener en cuenta de cara a las nuevas construcciones y a la rehabilitación energética de los edificios existentes. El síndrome del edificio enfermo, un conjunto de molestias y síntomas asociados a la baja calidad del aire de edificios no residenciales que surgió a raíz de la crisis del petróleo de 1973, tuvo su origen en una ventilación deficiente y una renovación del aire interior insuficiente de estos edificios, producto del intento de ahorro en la factura energética. Teniendo en cuenta que, de media, pasamos un 58% de nuestro tiempo en las viviendas, es fundamental cuidar la calidad del aire interior y no empeorarla aplicando medidas de “eficiencia energética” con efectos no esperados. Para conseguir esto es fundamental conocer en profundidad cómo se produce la ventilación en la edificación en bloque en España en sus aspectos de calidad del aire interior y demanda energética asociada a la ventilación. El objetivo de esta tesis es establecer una metodología de caracterización y de optimización de las necesidades de ventilación para los espacios residenciales existentes en España que aúne el doble objetivo de garantizar la calidad ambiental y reducir la demanda energética de los mismos. La caracterización del parque edificatorio residencial español en cuanto a ventilación es concluyente: La vivienda en España se distribuye principalmente en tres periodos en los que se encuentran más del 80% del total de las viviendas construidas. El periodo anterior a las normas básicas de la edificación (NBE), de 1960 a 1980, el periodo desde 1980 al año 2005, con el mayor número total de viviendas construidas, guiado por la NTE ISV 75, y el periodo correspondiente a la edificación construida a partir del Código Técnico de la Edificación, en 2006, cuyo documento básico de condiciones de salubridad (DB HS3) es la primera norma de obligado cumplimiento en diseño y dimensionamiento de ventilación residencial en España. La selección de un modelo de bloque de viviendas de referencia, un valor medio y representativo, seleccionado de entre estos periodos, pero con cualidades que se extienden más allá de uno de ellos, nos permite realizar un intensivo análisis comparativo de las condiciones de calidad de aire interior y la demanda energética del mismo, aplicando las distintas configuraciones que presenta la ventilación en viviendas dependiendo del escenario o época constructiva (o normativa) en que esta fuera construida. Este análisis se lleva a cabo apoyándose en un doble enfoque: el modelado numérico de simulaciones y el análisis de datos experimentales, para comprobar y afinar los modelos y observar la situación real de las viviendas en estos dos aspectos. Gracias a las conclusiones del análisis previo, se define una estrategia de optimización de la ventilación basada fundamentalmente en dos medidas: 1) La introducción de un sistema de extracción mecánica y recuperación de calor que permita reducir la demanda energética debida a la renovación del aire y a la vez diluir los contaminantes interiores más eficazmente para mejorar, de esta forma, la calidad del ambiente interior. 2) La racionalización del horario de utilización de estos sistemas, no malgastando la energía en periodos de no ocupación, permitiendo una leve ventilación de fondo, debida a la infiltración, que no incida en pérdidas energéticas cuantiosas. A esta optimización, además de aplicar la metodología de análisis previo, en cuanto a demanda energética y calidad del aire, se aplica una valoración económica integradora y comparativa basada en el reglamento delegado EU244/2012 de coste óptimo (Cost Optimal Methodology). Los resultados principales de esta tesis son: • Un diagnóstico de la calidad del aire interior de la edificación residencial en España y su demanda energética asociada, imprescindible para lograr una rehabilitación energética profunda garantizando la calidad del aire interior. • Un indicador de la relación directa entre calidad de aire y demanda energética, para evaluar la adecuación de los sistemas de ventilación, respecto de las nuevas normativas de eficiencia energética y ventilación. • Una estrategia de optimización, que ofrece una alternativa de intervención, y la aplicación de un método de valoración que permite evaluar la amortización comparada de la instalación de los sistemas. ABSTRACT The housing building stock already built in Spain and Europe faces a deep renovation in the present and near future to accomplish with the objectives agreed in the European strategy for 2050. These objectives, for the building sector, are set in a 90% of Green House Gases (GHG) reduction compared to levels in 1990. This long‐term plan has set milestones to control the correct advance of achievement in 2020 and 2030. The main objective is to take advantage of the great potential to reduce energy demand from the building sector, in which housing represents 85% share in Spain. Among this reduction on building energy demand requirements, ventilation of dwellings becomes one of the challenges to solve as it’s directly connected to the indoor air quality (IAQ) and comfort conditions for the users, as well as proportional to the building energy demand on thermal conditioning. A big share of thermal losses in housing is caused by air renovation and infiltration through the envelope leaks. The European Directive on Building energy performance (EPBD), establishes the roots needed to reach the building sector objectives in terms of CO2 and GHG emissions. This directive sets the ventilation and renovation with clean air of the new and existing buildings as a fundamental requirement. The Sick Building Syndrome (SBS), an aggregation of symptoms and annoys associated to low air quality in non residential buildings, appeared as common after the 1973 oil crisis. It is originated in defective ventilation systems and deficient air renovation rates, as a consequence of trying to lower the energy bill. Accounting that we spend 58% of our time in dwellings, it becomes crucial to look after the indoor air quality and focus in not worsening it by applying “energy efficient” measures, with not expected side effects. To do so, it is primary to research in deep how the ventilation takes place in the housing blocks in Spain, in the aspects related to IAQ and ventilation energy demand. This thesis main objective is to establish a characterization and optimization methodology regarding the ventilation needs for existing housing in Spain, considering the twofold objective of guaranteeing the air quality as reducing the energy demand. The characterization of the existing housing building stock in Spain regarding ventilation is conclusive. More of 80% of the housing stock is distributed in 3 main periods: before the implementation of the firsts regulations on building comfort conditions (Normas Básicas de la Edificación), from 1960 to 1980; the period after the first recommendations on ventilation (NTE ISV 75) for housing were set, around 1980 until 2005 and; the period corresponding to the housing built after the existing mandatory regulation in terms of indoor sanity conditions and ventilation (Spanish Building Code, DB HS3) was set, in 2006. Selecting a representative blueprint of a housing block in Spain, which has medium characteristics not just within the 3 periods mention, but which qualities extent beyond the 3 of them, allows the next step, analyzing. This comparative and intense analyzing phase is focused on the air indoor conditions and the related energy demand, applying different configurations to the ventilation systems according to the different constructive or regulation period in which the building is built. This analysis is also twofold: 1) Numerical modeling with computer simulations and 2) experimental data collection from existing housing in real conditions to check and refine the models to be tested. Thanks to the analyzing phase conclusions, an optimization strategy on the ventilation of the housing stock is set, based on two actions to take: 1) To introduce a mechanical exhaust and intake ventilation system with heat recovery that allows reducing energy demand, as improves the capacity of the system to dilute the pollutant load. This way, the environmental quality is improved. 2) To optimize the schedule of the system use, avoids waste of energy in no occupancy periods, relying ventilation during this time in a light infiltration ventilation, intended not to become large and not causing extra energy losses. Apart from applying the previous analyzing methodology to the optimization strategy, regarding energy demand and air quality, a ROI valorization is performed, based on the cost optimal methodology (delegated regulation EU244/2012). The main results from the thesis are: • To obtain a through diagnose regarding air quality and energy demand for the existing housing stock in Spain, unavoidable to reach a energy deep retrofitting scheme with no air quality worsening. • To obtain a marker to relate air quality and energy demand and evaluate adequateness of ventilation systems, for the new regulations to come. • To establish an optimization strategy to improve both air quality and energy demand, applying a compared valorization methodology to obtain the Return On Investment (ROI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The disposition of actinides, most recently 239Pu from dismantled nuclear weapons, requires effective containment of waste generated by the nuclear fuel cycle. Because actinides (e.g., 239Pu and 237Np) are long-lived, they have a major impact on risk assessments of geologic repositories. Thus, demonstrable, long-term chemical and mechanical durability are essential properties of waste forms for the immobilization of actinides. Mineralogic and geologic studies provide excellent candidate phases for immobilization and a unique database that cannot be duplicated by a purely materials science approach. The “mineralogic approach” is illustrated by a discussion of zircon as a phase for the immobilization of excess weapons plutonium.