950 resultados para VENTILATORY RATE
Resumo:
The prevalence of obesity has increased to epidemic status worldwide. Thousands of morbidly obese individuals undergo bariatric surgery for sustained weight loss; however, mid- and long-term outcomes of this surgery are still uncertain. Our objective was to estimate the 10-year mortality rate, and determine risk factors associated with death in young morbidly obese adults who underwent bariatric surgery. All patients who underwent open Roux-in-Y gastric bypass surgery between 2001 and 2010, covered by an insurance company, were analyzed to determine possible associations between risk factors present at the time of surgery and deaths related and unrelated to the surgery. Among the 4344 patients included in the study, 79% were female with a median age of 34.9 years and median body mass index (BMI) of 42 kg/m2. The 30-day and 10-year mortality rates were 0.55 and 3.34%, respectively, and 53.7% of deaths were related to early or late complications following bariatric surgery. Among these, 42.7% of the deaths were due to sepsis and 24.3% to cardiovascular complications. Male gender, age ≥50 years, BMI ≥50 kg/m2, and hypertension significantly increased the hazard for all deaths (P<0.001). Age ≥50 years, BMI ≥50 kg/m2, and surgeon inexperience elevated the hazard of death from causes related to surgery. Male gender and age ≥50 years were the factors associated with increased mortality from death not related to surgery. The overall risk of death after bariatric surgery was quite low, and half of the deaths were related to the surgery. Older patients and superobese patients were at greater risk of surgery-related deaths, as were patients operated on by less experienced surgeons.
Resumo:
The main purpose of this study was to investigate the level of agreement between the gas exchange threshold (GET) and heart rate variability threshold (HRVT) during maximal cardiopulmonary exercise testing (CPET) using three different exercise modalities. A further aim was to establish whether there was a 1:1 relationship between the percentage heart rate reserve (%HRR) and percentage oxygen uptake reserve (%V˙O2R) at intensities corresponding to GET and HRVT. Sixteen apparently healthy men 17 to 28 years of age performed three maximal CPETs (cycling, walking, and running). Mean heart rate and V˙O2 at GET and HRVT were 16 bpm (P<0.001) and 5.2 mL·kg-1·min-1 (P=0.001) higher in running than cycling, but no significant differences were observed between running and walking, or cycling and walking (P>0.05). There was a strong relationship between GET and HRVT, with R2 ranging from 0.69 to 0.90. A 1:1 relationship between %HRR and %V˙O2R was not observed at GET and HRVT. The %HRR was higher during cycling (GET mean difference=7%; HRVT mean difference=11%; both P<0.001), walking (GET mean difference=13%; HRVT mean difference=13%; both P<0.001), or running (GET mean difference=11%; HRVT mean difference=10%; both P<0.001). Therefore, using HRVT to prescribe aerobic exercise intensity appears to be valid. However, to assume a 1:1 relationship between %HRR and %V˙O2R at HRVT would probably result in overestimation of the energy expenditure during the bout of exercise.
Resumo:
Few studies evaluate the amount of particulate matter less than 2.5 mm in diameter (PM2.5) in relation to a change in lung function among adults in a population. The aim of this study was to assess the association of coal as a domestic energy source to pulmonary function in an adult population in inner-city areas of Zunyi city in China where coal use is common. In a cross-sectional study of 104 households, pulmonary function measurements were assessed and compared in 110 coal users and 121 non-coal users (≥18 years old) who were all nonsmokers. Several sociodemographic factors were assessed by questionnaire, and ventilatory function measurements including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), the FEV1/FVC ratio, and peak expiratory flow rate (PEFR) were compared between the 2 groups. The amount of PM2.5 was also measured in all residences. There was a significant increase in the relative concentration of PM2.5 in the indoor kitchens and living rooms of the coal-exposed group compared to the non-coal-exposed group. In multivariate analysis, current exposure to coal smoke was associated with a 31.7% decrease in FVC, a 42.0% decrease in FEV1, a 7.46% decrease in the FEV1/FVC ratio, and a 23.1% decrease in PEFR in adult residents. The slope of lung function decrease for Chinese adults is approximately a 2-L decrease in FVC, a 3-L decrease in FEV1, and an 8 L/s decrease in PEFR per count per minute of PM2.5 exposure. These results demonstrate the harmful effects of indoor air pollution from coal smoke on the lung function of adult residents and emphasize the need for public health efforts to decrease exposure to coal smoke.
Resumo:
In anurans, changes in ambient temperature influence body temperature and, therefore, energy consumption. These changes ultimately affect energy supply and, consequently, heart rate (HR). Typically, anurans living in different thermal environments have different thermal sensitivities, and these cannot be distinguished by changes in HR. We hypothesized that Rhinella jimi (a toad from a xeric environment that lives in a wide range of temperatures) would have a lower thermal sensitivity regarding cardiac control than R. icterica (originally from a tropical forest environment with a more restricted range of ambient temperatures). Thermal sensitivity was assessed by comparing animals housed at 15° and 25°C. Cardiac control was estimated by heart rate variability (HRV) and heart rate complexity (HRC). Differences in HRV between the two temperatures were not significant (P=0.214 for R. icterica and P=0.328 for R. jimi), whereas HRC differences were. All specimens but one R. jimi had a lower HRC at 15°C (all P<0.01). These results indicate that R. jimi has a lower thermal sensitivity and that cardiac control is not completely dependent on the thermal environment because HRC was not consistently different between temperatures in all R. jimi specimens. This result indicates a lack of evolutive trade-offs among temperatures given that heart rate control at 25°C is potentially not a constraint to heart rate control at 15°C.
Resumo:
The autonomic nervous system maintains homeostasis, which is the state of balance in the body. That balance can be determined simply and noninvasively by evaluating heart rate variability (HRV). However, independently of autonomic control of the heart, HRV can be influenced by other factors, such as respiratory parameters. Little is known about the relationship between HRV and spirometric indices. In this study, our objective was to determine whether HRV correlates with spirometric indices in adults without cardiopulmonary disease, considering the main confounders (e.g., smoking and physical inactivity). In a sample of 119 asymptomatic adults (age 20-80 years), we evaluated forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). We evaluated resting HRV indices within a 5-min window in the middle of a 10-min recording period, thereafter analyzing time and frequency domains. To evaluate daily physical activity, we instructed participants to use a triaxial accelerometer for 7 days. Physical inactivity was defined as <150 min/week of moderate to intense physical activity. We found that FVC and FEV1, respectively, correlated significantly with the following aspects of the RR interval: standard deviation of the RR intervals (r =0.31 and 0.35), low-frequency component (r =0.38 and 0.40), and Poincaré plot SD2 (r =0.34 and 0.36). Multivariate regression analysis, adjusted for age, sex, smoking, physical inactivity, and cardiovascular risk, identified the SD2 and dyslipidemia as independent predictors of FVC and FEV1 (R2=0.125 and 0.180, respectively, for both). We conclude that pulmonary function is influenced by autonomic control of cardiovascular function, independently of the main confounders.
Resumo:
Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.
Resumo:
The objective of this work was to study the influence of temperature on the respiration rate of minimally processed organic carrots (Daucus Carota L. cv. Brasília) with and without the application of a gelatin film. The samples were packed in flexible bags and stored at 1, 5 and 10 °C. During the five days of storage, the CO2 and O2 concentrations in the headspace of the package were monitored by gas chromatography, and the mathematical model based on enzymatic kinetics was used to estimate the respiration rate of minimally processed organic carrots. The effect of temperature on the respiration rate was evaluated by the Arrhenius equation. The results showed that the O2 concentration decreased during the storage period and the CO2 concentration increased. The lowest O2 concentrations of 2.59 and 2.66% were found for the samples stored at 10 °C with and without the film, respectively. For the CO2 concentration, the highest concentrations of 16.25 and 16.32% were again found for the temperature of 10 °C with and without the application of the film, respectively. At the temperature of 1 °C, the maximum respiratory rates for the samples without and with the film were 10.82 and 10.44 mL CO2.kg-1/hour, respectively, after 72 hours of storage. The greatest respiratory rate was obtained at 10 °C, the maximum peak being reached after 50 hours. Activation energy values were of 50.59 kJ.mol-1, for the samples with the film, and 51.88 kJ.mol-1 for the samples without the film.
Resumo:
In this study, the influence of storage temperature and passive modified packaging (PMP) on the respiration rate and physicochemical properties of fresh-cut Gala apples (Malus domestica B.) was investigated. The samples were packed in flexible multilayer bags and stored at 2 °C, 5 °C, and 7 °C for eleven days. Respiration rate as a function of CO2 and O2 concentrations was determined using gas chromatography. The inhibition parameters were estimated using a mathematical model based on Michaelis-Menten equation. The following physicochemical properties were evaluated: total soluble solids, pH, titratable acidity, and reducing sugars. At 2 °C, the maximum respiration rate was observed after 150 hours. At 5 °C and 7 °C the maximum respiration rates were observed after 100 and 50 hours of storage, respectively. The inhibition model results obtained showed a clear effect of CO2 on O2 consumption. The soluble solids decreased, although not significantly, during storage at the three temperatures studied. Reducing sugars and titratable acidity decreased during storage and the pH increased. These results indicate that the respiration rate influenced the physicochemical properties.
Resumo:
Abstract Bread is one of the most consumed foods in the world, and alternatives have been sought to extend its shell life, and freezing is one of the most popular methods. The purpose of this study was to evaluate the effect of freezing rate and trehalose concentration on the fermentative and viscoelastic properties of dough and bread quality. Dough was prepared and trehalose was added at three concentrations (0, 400, 800 ppm); dough was pre fermented and frozen at two freezing rates then stored for 42 days. Frozen dough samples were thawed every two weeks. CO2 production and elastic and viscous modulus were determined. In addition, bread was elaborated and specific volume and firmness were evaluated. High trehalose concentrations (400 and 800 ppm) produced dough with the best viscoelastic and fermentative properties. Greater bread volume and less firmness were observed when a slow freezing rate (-.14 °C/min) was employed.
Resumo:
INTRODUCTION: Chronic kidney disease (CKD) and obesity are both associated with reduced physical capacity. The potential benefit of aerobic training on physical capacity has been recognized. The exercise intensity can be established using different methods mostly subjective or indirect. Ventilatory threshold (VT) is a direct and objective method that allows prescribing exercise intensity according to individual capacity. OBJECTIVES: To evaluate the impact of aerobic training at VT intensity on cardiopulmonary and functional capacities in CKD patients with excess of body weight. METHODS: Ten CKD patients (eight men, 49.7 ± 10.1 years; BMI 30.4 ± 3.5 kg/m², creatinine clearance 39.4 ± 9.8 mL/min/1.73 m²) underwent training on a treadmill three times per week during 12 weeks. Cardiopulmonary capacity (ergoespirometry), functional capacity and clinical parameters were evaluated. RESULTS: At the end of 12 weeks, VO2PEAK increased by 20%, and the speed at VO2PEAK increased by 16%. The training resulted in improvement in functional capacity tests, such as six-minute walk test (9.2%), two-minute step test (20.3%), arm curl test (16.3%), sit and stand test (35.7%), and time up and go test (15.3%). In addition, a decrease in systolic and diastolic blood pressures was observed despite no change in body weight, sodium intake and antihypertensive medication. CONCLUSION: Aerobic exercise performed at VT intensity improved cardipulmonary and functional capacities of overweight CKD patients. Additional benefit on blood pressure was observed. These results suggest that VT can be effectively applied for prescribing exercise intensity in this particular group of patients.
Resumo:
This paper examines how exchange rate policies and IMF Stand-By Arrangements affect debt crises using econometrics and a comparison between Argentina and Brazil. It refines an existing diagram outlining crisis development to propose crisis prevention strategies. Flexible exchange rate policies reduce a country's probability of default by over 4%, but Stand-By Arrangements increase it by an inconsequential percentage. Unlike Argentina, Brazil avoided a default via a freely-floating exchange rate system, fiscal deficit reduction, and a cooperative and coordinated relationship with the IMF. The results provide policymakers from developing countries with lessons to manage their countries' default risks more effectively.
Resumo:
In the last two decades an entirely new set of rules governing the foreign exchange transactions was established in Brazil, substituting for the framework inherited from the 1930s. Foreign exchange controls were dismantled and a floating exchange rate regime replaced different forms of peg. In this paper we argue that although successful by comparison to previous experiences, the current arrangement has important flaws that should be addressed. We discuss how it first led to high volatility and extremely high interest rates, which, when overcome, gave way to a long lasting appreciation of the real exchange rate with adverse consequences to industry.