938 resultados para ULTRASOUND-GUIDED BIOPSY
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose of reviewLung ultrasound at the bedside can provide accurate information on lung status in critically ill patients with acute respiratory distress syndrome.Recent findingsLung ultrasound can replace bedside chest radiography and lung computed tomography for assessment of pleural effusion, pneumothorax, alveolar- interstitial syndrome, lung consolidation, pulmonary abscess and lung recruitment/de-recruitment. It can also accurately determine the type of lung morphology at the bedside (focal or diffuse aeration loss), and therefore it is useful for optimizing positive end-expiratory pressure. The learning curve is brief, so most intensive care physicians will be able to use it after a few weeks of training.SummaryLung ultrasound is noninvasive, easily repeatable and allows assessment of changes in lung aeration induced by the various therapies. It is among the most promising bedside techniques for monitoring patients with acute respiratory distress syndrome.
Resumo:
To assess the accuracy of a multiplane ultrasound approach to measure pleural effusion volume (PEV), considering pleural effusion (PE) extension along the cephalocaudal axis and PE area.Prospective study performed on 58 critically ill patients with 102 PEs. Thoracic drainage was performed in 46 patients (59 PEs) and lung computed tomography (CT) in 24 patients (43 PEs). PE was assessed using bedside lung ultrasound. Adjacent paravertebral intercostal spaces were examined, and ultrasound PEV was calculated by multiplying the paravertebral PE length by its area, measured at half the distance between the apical and caudal limits of the PE.Ultrasound PEV was compared to either the volume of the drained PE (59 PE) or PEV assessed on lung CT (43 PE). In patients with lung CT, the accuracy of this new method was compared to the accuracy of previous methods proposed for PEV measurement. Ultrasound PEV was tightly correlated with drained PEV (r = 0.84, p < 0.001) and with CT PEV (r = 0.90, p < 0.001). The mean biases between ultrasound and actual volumes of PE were -33 ml when compared to drainage (limits of agreement -292 to +227 ml) and -53 ml when compared to CT (limits of agreement -303 to +198 ml). This new method was more accurate than previous methods to measure PEV.Using a multiplane approach increases the accuracy of lung ultrasound to measure the volume of large to small pleural effusions in critically ill patients.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this work is to prospectively study the value of thoracic ultrasound (US) before pleural drainage in children with parapneumonic effusion (PPE). All children hospitalized for PPE, identified by thoracic radiography, underwent US to assess pleural loculation, echogenicity, and pleural fluid quantity. From August 2001 to July 2003, 52 children were examined. US was performed on 48 of these children, of whom 35 received chest tube drainage and 13 only received clinical treatment. US identified 38 patients with free flowing and 10 with loculated pleural fluid. About 25 of the free flowing (65.8%) and 10 (100%) of the loculated patients received chest tube drainage. Echogenicity was anechoic in 13, echoic without septations in 17 and echoic with septations in 18. Chest tube drainage was required in 6 anechoic (46.15%), 14 echoic without septations (82.35%), and 15 echoic with septations (83.33%). Quantity of fluid estimated by US varied from 20 to 860 ml. Effusion volume was higher in patients that were echoic with septations and loculated effusions. Pleural glucose and pH were lower, and LDH was higher in loculated PPE patients. In conclusion, US is an auxiliary exam for determining whether thoracic drainage is needed in parapneumonic effusion; loculated or echoic effusion should be drained, and free anechoic fluid needs further investigation.
Resumo:
Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.
Resumo:
OBJECTIVE: To measure thyroid cell proliferation in patients with Graves' disease (GD) before and during treatment with antithyroid drugs.STUDY DESIGN: Patients were assessed by fine needle aspiration biopsy before (n=20) and after 4 (n=19) and 12 months of treatment (n=15) with propylthiouracil or methimazole. Cell proliferation index (CPI) was estimated by immunocytochemistry using MIB-1. CPI was studied in relation to the cytologic parameters of the smears; clinical parameters, such as Wayne's Clinical Index (WCI) and time without treatment; laboratory parameters, such as (131)Iuptake and dosage of serum free thyroxin and thyroid-stimulating hormone; and thyroid ultrasound.RESULTS: CPI varied from 0.00% to 25.00% before treatment, 0.00% to 23.00% at 4 months and 0.00% to 14.84% at 12 months. CPI median values were 6.50%, 4.30% and 3.30%, respectively (before and after 4 months and 12 months of treatment). CPI had a positive correlation with WCI and FT4 at 12 months of treatment.CONCLUSION: Thyroid CPI in GD varies from case to case. However, due to its decreasing pattern during follow-up and its positive correlation with thyrotoxicosis severity, CPI may indicate the functional status of the gland and contribute to a better understanding of GD.
Resumo:
BACKGROUND: the objective of the present study was to determine the importance of the site of embryo transfer (upper or lower half endometrial cavity) on implantation and clinical pregnancy rates. METHODS: A total of 400 transfers guided by ultrasound were randomly assigned to two groups according to the distance between the uterine fundus and the catheter tip at the time of embryo placement. Group I (n=200) consisted of transfers corresponding to a distance of <50% of the endometrial cavity length (ECL), i.e. transfer in upper half of the cavity; and group II (n=200) consisted of transfers corresponding to a distance of greater than or equal to50%, of the ECL, i.e. transfer in lower half of cavity. The Student's t-test, Mann-Whitney test and Fisher's exact test were used where appropriate. RESULTS: the general characteristics of the study population and the main transfer cycle characteristics had an equal distribution (P>0.05) between groups I and II. No significant difference in implantation or pregnancy rates was observed between groups I and II. CONCLUSION: the implantation or pregnancy rates were similar whether the embryos were deposited in the upper or lower half of the endometrial cavity.
Resumo:
Background Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules.Methods In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into ultrasound'' and control'' groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light.Results Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization.Conclusion The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.
Resumo:
AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,
Resumo:
Objetivo: descrever caso clínico de um lactente com insuficiência renal crônica terminal, causada por hiperoxalúria primária.Método: após revisão da literatura, verifica-se a raridade da doença; na França, a prevalência é de 1,05/milhão, com taxa de incidência de 0,12/milhão/ano. Pesquisa abordando centros especializados mundiais detectou, em 1999, 78 casos em lactentes; destes, em 14% o quadro inicial foi de uremia. A gravidade e a raridade da doença sugerem o relato deste caso.Resultados: criança de sexo feminino, com quadro de vômitos e baixo ganho de peso desde os primeiros meses de vida, desenvolveu insuficiência renal terminal aos 6 meses de idade, sendo mantida em tratamento dialítico desde então. Aos 8 meses, foi encaminhada para esclarecimento diagnóstico, apresentando déficit pôndero-estatural grave e os seguintes exames laboratoriais: uréia= 69 mg/dl, creatinina=2,2 mg/dl e clearance de creatinina= 12,5 ml/min/1.73m²SC. O exame de urina foi normal, a ultra-sonografia renal revelou tamanho normal e hiperecogenicidade de ambos os rins. A dosagem de oxalato urinário foi de 9,2mg/kg/dia ou 0,55 mmol/1.73m²SC, e a relação oxalato:creatinina, de 0,42. A biópsia renal diagnosticou presença de grande quantidade de depósitos de cristais de oxalato de cálcio no parênquima renal. A radiografia de ossos longos evidenciou sinais sugestivos de osteopatia oxalótica, e a fundoscopia indireta, sinais de retinopatia por oxalato. A criança foi mantida em diálise peritoneal ambulatorial contínua, tendo sido iniciado tratamento com piridoxina.Conclusões: a hiperoxalúria primária deve ser considerada como um dos diagnósticos diferenciais de insuficiência renal crônica em lactentes, especialmente na ausência de história sugestiva de outras patologias.
Resumo:
Background: Barrier materials as cellulose membranes are used for guided tissue repair. However, it is essential that the surrounding tissues accept the device. The present study histologically evaluated tissue reaction to a microbial cellulose membrane after subcutaneous implantation in mice. Furthermore, the interaction between mesenchymal stem cells and the biomaterial was studied in vitro to evaluate its ability to act as cellular scaffold for tissue engineering.Methods: Twenty-five Swiss Albino mice were used. A 10 x 10 mm cellulose membrane obtained through biosynthesis using Acetobacter xylinum bacteria was implanted into the lumbar subcutaneous tissue of each mouse. The mice were euthanatized at seven, 15, 30, 60, and 90 days, and the membrane and surrounding tissues were collected and examined by histology.Results: A mild inflammatory response without foreign body reaction was observed until 30 days post-surgery around the implanted membrane. Polarized microscopy revealed that the membrane remained intact at all evaluation points. Scanning electron microscopy of the cellulose membrane surface showed absence of pores. The in vitro evaluation of the interaction between cells and biomaterial was performed through viability staining analysis of the cells over the biomaterial, which showed that 95% of the mesenchymal stem cells aggregating to the cellulose membrane were alive and that 5% were necrotic. Scanning electron microscopy showed mesenchymal stem cells with normal morphology and attached to the cellulose membrane surface.Conclusion: The microbial cellulose membrane evaluated was found to be nonresorbable, induced a mild inflammatory response and may prove useful as a scaffold for mesenchymal stem cells.
Resumo:
The aim of the present study was to examine the impact of polymorphisms in prostate-specific antigen (PSA) and androgen-related genes (AR, CYP17, and CYP19) on prostate cancer (PCa) risk in selected high-risk patients who underwent prostate biopsy. Blood samples and prostate tissues were obtained for DNA analysis. Single-nucleotide polymorphisms in the 50-untranslated regions (UTRs) of the PSA (substitution A > G at position -158) and CYP17 (substitution T > C at 50-UTR) genes were detected by polymerase chain reaction (PCR)-restriction fragment length polymorphism assays. The CAG and TTTA repeats in the AR and CYP19 genes, respectively, were genotyped by PCR-based GeneScan analysis. Patients with the GG genotype of the PSA gene had a higher risk of PCa than those with the AG or AA genotype (OR = 3.79, p = 0.00138). The AA genotype was associated with lower PSA levels (6.44 +/- 1.64 ng/mL) compared with genotypes having at least one G allele (10.44 +/- 10.06 ng/mL) (p = 0.0687, 95% CI - 0.3146 to 8.315, unpaired t-test). The multivariate analysis confirmed the association between PSA levels and PSA genotypes (AA vs. AG+GG; chi(2) = 0.0482) and CYP19 (short alleles homozygous vs. at least one long allele; chi(2) = 0.0110) genotypes. Genetic instability at the AR locus leading to somatic mosaicism was detected in one PCa patient by comparing the length of AR CAG repeats in matched peripheral blood and prostate biopsy cores. Taken together, these findings suggest that the PSA genotype should be a clinically relevant biomarker to predict the PCa risk.