994 resultados para Total correlations
Resumo:
A theoretical density-functional study has been carried out to analyze the exchange coupling in the chains of CuGeO3 using discrete models. The results show a good agreement with the experimental exchange coupling constant (J) together with a strong dependence of J with the Cu-O-Cu angle. The calculation of the J values for a distorted model indicates a larger degree of dimerization than those reported previously.
Resumo:
A theoretical density-functional study has been carried out to analyze the exchange coupling in the chains of CuGeO3 using discrete models. The results show a good agreement with the experimental exchange coupling constant (J) together with a strong dependence of J with the Cu-O-Cu angle. The calculation of the J values for a distorted model indicates a larger degree of dimerization than those reported previously.
Resumo:
BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
Resumo:
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
This prospective study addresses early results of the treatment of acute acetabular fractures in elderly patients by total hip arthroplasty and cerclage wiring.Fifteen patients with an average age of 81 years were treated at our institution between February 1998 and December 2000. There were two transverse fractures, eight T-shaped fractures, two transverse fractures with associated posterior wall fracture, two posterior column fractures with associated posterior wall fracture, and one fracture of both columns. Treatment consisted of cerclage wiring of the fracture and primary non-cemented total hip replacement.All of the patients were followed for a mean of 36 months. Although there was one patient with three hip dislocations during the first 10 months after the operation, we found an excellent or good result for the entire group. During this relatively short follow-up period, we have not found a radiological loss of fracture reduction of more than 1 mm or a cup migration of more than 3.2 mm. All of the fractures healed and no loosening of the implant was evident.Primary total hip arthroplasty combined with internal fixation is a valid treatment option for acetabular fractures in the elderly. Preliminary results are convincing, but a bigger patient population and a longer follow-up time are necessary before we are able to draw final conclusions.
Resumo:
The purpose of this project was to investigate the potential for collecting and using data from mobile terrestrial laser scanning (MTLS) technology that would reduce the need for traditional survey methods for the development of highway improvement projects at the Iowa Department of Transportation (Iowa DOT). The primary interest in investigating mobile scanning technology is to minimize the exposure of field surveyors to dangerous high volume traffic situations. Issues investigated were cost, timeframe, accuracy, contracting specifications, data capture extents, data extraction capabilities and data storage issues associated with mobile scanning. The project area selected for evaluation was the I-35/IA 92 interchange in Warren County, Iowa. This project covers approximately one mile of I-35, one mile of IA 92, 4 interchange ramps, and bridges within these limits. Delivered LAS and image files for this project totaled almost 31GB. There is nearly a 6-fold increase in the size of the scan data after post-processing. Camera data, when enabled, produced approximately 900MB of imagery data per mile using a 2- camera, 5 megapixel system. A comparison was done between 1823 points on the pavement that were surveyed by Iowa DOT staff using a total station and the same points generated through the MTLS process. The data acquired through the MTLS and data processing met the Iowa DOT specifications for engineering survey. A list of benefits and challenges is included in the detailed report. With the success of this project, it is anticipate[d] that additional projects will be scanned for the Iowa DOT for use in the development of highway improvement projects.
Resumo:
We conducted a genome-wide scan using variance components linkage analysis to localize quantitative-trait loci (QTLs) influencing triglyceride (TG), high density lipoprotein-cholesterol (HDL-C), low density lipoprotein-cholesterol, and total cholesterol (TC) levels in 3,071 subjects from 459 families with atherogenic dyslipidemia. The most significant evidence for linkage to TG levels was found in a subset of Turkish families at 11q22 [logarithm of the odds ratio (LOD)=3.34] and at 17q12 (LOD=3.44). We performed sequential oligogenic linkage analysis to examine whether multiple QTLs jointly influence TG levels in the Turkish families. These analyses revealed loci at 20q13 that showed strong epistatic effects with 11q22 (conditional LOD=3.15) and at 7q36 that showed strong epistatic effects with 17q12 (conditional LOD=3.21). We also found linkage on the 8p21 region for TG in the entire group of families (LOD=3.08). For HDL-C levels, evidence of linkage was identified on chromosome 15 in the Turkish families (LOD=3.05) and on chromosome 5 in the entire group of families (LOD=2.83). Linkage to QTLs for TC was found at 8p23 in the entire group of families (LOD=4.05) and at 5q13 in a subset of Turkish and Mediterranean families (LOD=3.72). These QTLs provide important clues for the further investigation of genes responsible for these complex lipid phenotypes. These data also indicate that a large proportion of the variance of TG levels in the Turkish population is explained by the interaction of multiple genetic loci.
Resumo:
Este trabalho teve por objetivo estudar sistemas de informação para gerenciamento de pequenas empresas participantes do Programa de Qualidade Total, do Sebrae, na região de Campinas. Na elaboração de um proposta de modelo de sistema de informações para o executivo de empresas de pequeno porte, foi necessário identificar não apenas as características relacionadas às áreas de negócios, mas também as específicas em relação aos setores industrial, comercial e serviços. Para o conhecimento dessas características, foi realizado um diagnóstico para identificação dos recursos de informática, fontes, produtos e serviços de informação utilizados em pequenas empresas. Foram propostos indicadores de informação para o gerenciamento de programa de qualidade total, tendo como suporte o Executive Informations Systems (EIS).
Resumo:
Selostus: Luonnonvarojen kokonaiskäyttö sovellettuna maatalouteen: esimerkki Suomesta
Resumo:
Objectives: Total ankle replacement (TAR) is increasingly used for treatment of primary or posttraumatic arthritis of the ankle joint, if joint movement is intended to be preserved. Data on characteristics and treatment of ankle prosthetic joint infection (PJI) is limited and no validated therapeutic algorithm exist. Therefore, we analyzed all infections, which occurred in a cohort of implanted ankle prostheses during a 5-year-period.Methods: Between 06/2004 and 12/2008, all patients with an implanted ankle prosthesis at our institution were retrospectively reviewed. All patients were operated by the same surgical team. Ankle PJI was defined as visible purulence, acute inflammation on histopathology, sinus tract, or microbial growth in periprosthetic tissue or sonication fluid of the removed prosthesis. The surgery on the infected ankle prosthesis and the follow-up were performed by the surgical team, who implanted the prosthesis. A specialized septic team consisting of an orthopaedic surgeon and infectious diseases consultant were included in the treatment.Results: During the study period, 92 total ankle prostheses were implanted in 90 patients (mean age 61 years, range 28-80 years). 78 patients had posttraumatic arthritis, 11 rheumatoid arthritis and 3 other degenerative disorder. Ankle PJI occurred in 3 of 92 TAR (3.3%), occurring 1, 2 and 24 months after implantation; the causative organisms were Enterobacter cloacae, Streptococcus pyogenes and Staphylococcus epidermidis, respectively. The ankle prosthesis was removed in all infected patients, including debridement of the surrounding tissue was debrided and insertion of an antibiotic loaded spacer. Provisional arthrodesis was performed by external fixation in two patients and by plaster cast in one. A definitive ankle arthrodesis with a retrograde nail was performed 6 to 8 weeks after prosthesis removal. One patient needed a flap coverage. All 3 patients received intravenous antibiotic treatment for 2 weeks, followed by oral antibiotics for 4-6 weeks. At follow-up visit up to 18 months after start of treatment, all patients were without clinical or laboratory signs of infection.Conclusions: The infection incidence after TAR was 3.3%, which is slightly higher than reported after hip (<1%) or knee arthroplasty (<2%). A two-step approach consisting of removal of the infected prosthesis, combined with local and systemic antibiotic treatment, followed by definitive ankle arthrodesis shows good results. Larger patient cohort and longer follow-up evaluation is needed to define the optimal treatment approach for ankle PJI.
Resumo:
Macroscopic features such as volume, surface estimate, thickness and caudorostral length of the human primary visual cortex (Brodman's area 17) of 46 human brains between midgestation and 93 years were studied by means of camera lucida drawings from serial frontal sections. Individual values were best fitted by a logistic function from midgestation to adulthood and by a regression line between adulthood and old age. Allometric functions were calculated to study developmental relationships between all the features. The three-dimensional shape of area 17 was also reconstructed from the serial sections in 15 cases and correlated with the sequence of morphological events. The sulcal pattern of area 17 begins to develop around 21 weeks of gestation but remains rather simple until birth, while it becomes more convoluted, particularly in the caudal part, during the postnatal period. Until birth, a large increase in cortical thickness (about 83% of its mean adult value) and caudorostral length (69%) produces a moderate increase in cortical volume (31%) and surface estimate (40%) of area 17. After birth, the cortical volume and surface undergo their maximum growth rate, in spite of a rather small increase in cortical thickness and caudorostral length. This is due to the development of the pattern of gyrification within and around the calcarine fissure. All macroscopic features have reached the mean adult value by the end of the first postnatal year. With aging, the only features to undergo significant regression are the cortical surface estimate and the caudorostral length. The total number of neurons in area 17 shows great interindividual variability at all ages. No decrease in the postnatal period or in aging could be demonstrated.
Resumo:
Visual scuba diving censuses were used to assess the effects of fishing prohibition on abundance and size structure of littoral fish populations by comparing the same benthic communities inside and outside the protected area of Medes Islands (NE Catalonia, Spain). The total number of species found was 43 in the reserve and 44 outside, but the mean value of species richness per sampling station was significantly higher in the protected area. However, diversity, heavily affected by the presence or absence of large schools of pelagic species, showed no significant differences between sites. The prohibition of fishing for 6 years is the first factor affecting the qualitative and quantitative structure of fish populations ('reserve effect'), and depth is the second factor. Thus, except in the cases of Serranus cabrilla and Mullus surmuletus, all other vulnerable species are highly sensitive to the protection measures. The size structure of all vulnerable species was found to be absolutely different at the reserve sites than in the unprotected zones, and the modal size classes of size frequency distributions were always higher in the reserve than outside. The reserve effect was significantly responsible of the differences observed in this change on size structure. Some highly vulnerable species, such as Epinephelus guaza and Sciaena umbra, have only been found in the protected area. Others, such as Sparus aurata, Diplodus cervinus and Dicentrarchus labrax, were much more frequent inside the reserve.
Resumo:
Este trabalho foi conduzido para avaliar o efeito da germinação sobre os constituintes antinutricionais da soja, ácido fítico, P total e inibidores de tripsina, que interferem na utilização de proteínas e outras substâncias. A diminuição no aproveitamento de nutrientes resulta em inibição de crescimento, hipoglicemia ou danos a tecidos animais. Para os ensaios foram utilizadas as cultivares de soja (Glycine max (L.) Merrill ) BR-13 e Paraná. As sementes foram incubadas em câmara de germinação a 25°C e 100% de umidade, de 0 a 72 horas, com coleta de amostras em intervalos eqüidistantes de seis horas. A cultivar Paraná apresentou teores superiores de ácido fítico, P total e inibidores de tripsina, em relação à cultivar BR-13. As análises de variância e comparações entre médias indicaram que houve aumentos significativos (p < 0,05) nos teores de P total (8,5% e 3,6% nas cultivares BR-13 e Paraná, respectivamente) e nos níveis de inibidores de tripsina (22,05% e 17,10% nas cultivares BR-13 e Paraná, respectivamente), e reduções nos teores de ácido fítico (15,96% e 9,46% nas cultivares BR-13 e Paraná, respectivamente), em 72 horas de germinação.
Resumo:
Background Obesity may have an impact on key aspects of health-related quality of life (HRQOL). In this context, the Impact of Weight Quality of Life (IWQOL) questionnaire was the first scale designed to assess HRQOL. The aim of the present study was twofold: to assess HRQOL in a sample of Spanish patients awaiting bariatric surgery and to determine the psychometric properties of the IWQOL-Lite and its sensitivity to detect differences in HRQOL across groups. Methods Participants were 109 obese adult patients (BMI¿ 35 kg/m2) from Barcelona, to whom the following measurement instruments were applied: IWQOL-Lite, Depression Anxiety Stress Scales, Brief Symptom Inventory, and self-perception items. Results Descriptive data regarding the IWQOL-Lite scores obtained by these patients are reported. Principal components analysis revealed a five-factor model accounting for 72.05% of the total variance, with factor loadings being adequate for all items. Corrected itemtotal correlations were acceptable for all items. Cronbach"s alpha coefficients were excellent both for the subscales (0.880.93) and the total scale (0.95). The relationship between the IWQOLLite and other variables supports the construct validity of the scale. Finally, sensitivity analysis revealed large effect sizes when comparing scores obtained by extreme BMI groups. Conclusions This is the first study to report the application of the IWQOL-Lite to a sample of Spanish patients awaiting bariatric surgery and to confirm that the Spanish version of the instrument has adequate psychometric properties.
Resumo:
Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to develop instruments to quantitatively assess the soft-tissue balance since excessive imbalance can accelerate prosthesis wear and lead to early surgical revision. The instrumented distractor proposed in this study can assist surgeons on performing ligament balance by measuring the distraction gap and applied load. Also the device allows the determination of the ligament stiffness which can contribute a better understanding of the intrinsic mechanical behavior of the knee joint. Instrumentation of the device involved the use of hall-sensors for measuring the distractor displacement and strain gauges to transduce the force. The sensors were calibrated and tested to demonstrate their suitability for surgical use. Results show the distraction gap can be measured reliably with 0.1mm accuracy and the distractive loads could be assessed with an accuracy in the range of 4N. These characteristics are consistent with those have been proposed, in this work, for a device that could assist on performing ligament balance while permitting surgeons evaluation based on his experience. Preliminary results from in vitro tests were in accordance with expected stiffness values for medial collateral ligament (MCL) and lateral collateral ligament (LCL).