986 resultados para Structural determination


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of serological markers for hepatitis B virus (HBsAg, anti-HBc IgM and Anti-HBc total) was investigated in the serum of 1,396 individuals who had clinical suspect of hepatitis. It was observed that 50.7% of the individuals were positive and, from the total of the studied individuals, 14.5% were positive for HBsAg. From these, 8.5% were also positive for anti-HBc IgM. The analysis in relation to gender showed a higher seroprevalence index among male individuals (p < 0.0001). It was observed the occurrence of subtypes adw2 (62.7%), ayw3 (23.5%), ayw2 (9.8%) and adw4 (3.9%). The viral DNA was detected in 61 (33.9%) HBsAg positive samples and in one sample positive only for anti-HBc total. These results indicate an important incidence of the HBV infection in this population, and reinforce previous studies regarding this virus in the central west region of Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, α-cyclodextrin, β-cyclodextrin, or γ-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade−1 and detection limits of 3.91 × 10−5 mol L−1. The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7–62.0 mV decade−1 and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2–7. The sensors displayed fast response, always <15 s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seroprevalence of HCMV in Costa Rica is greater than 95% in adults; primary infections occur early in life and is the most frequent congenital infection in newborns. The objectives of this study were to determine the genetic variability and genotypes of HCMV gB gene in Costa Rica. Samples were collected from alcoholics, pregnant women, blood donors, AIDS patients, hematology-oncology (HO) children and HCMV isolates from neonates with cytomegalic inclusion disease. A semi-nested PCR system was used to obtain a product of 293-296 bp of the gB gene to be analyzed by Single Stranded Conformational Polymorphism (SSCP) and sequencing to determine the genetic polymorphic pattern and genotypes, respectively. AIDS patients showed the highest polymorphic diversity with 14 different patterns while fifty-six percent of HO children samples showed the same polymorphic pattern, suggesting in this group a possible nosocomial infection. In neonates three genotypes (gB1, gB2 and gB3), were determined while AIDS patients and blood donors only showed one (gB2). Of all samples analyzed only genotypes gB1, 2 and 3 were determined, genotype gB2 was the most frequent (73%) and mixed infections were not detected. The results of the study indicate that SSCP could be an important tool to detect HCMV intra-hospital infections and suggests a need to include additional study populations to better determine the genotype diversity and prevalence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente relatório versa sobre a análise e dimensionamento de estruturas de aço enformadas a frio. Devido a serem estruturas de elevada esbelteza, frequentemente denominadas “estruturas de aço leve”, apresentam fenómenos de instabilidade tanto a nível local como global, sendo da perspetiva regulamentar abrangidas pelo Eurocódigo 3, nomeadamente pelas Partes 1-1, 1-3 e 1-5. A Parte 1-3 do Eurocódigo 3 diz respeito às regras suplementares de elementos de aço enformados a frio, na qual estão presentes as regras de dimensionamento, bem como as verificações de segurança que deverão ser aplicadas. Nesta, é possível ainda “fazer a ponte” com a Parte 1-1 do Eurocódigo 3, respetiva às regras gerais de projeto de estruturas de aço e com a Parte 1-5 do Eurocódigo 3 relativa a elementos estruturais constituídos por placas. Inicialmente, será realizado um estado da arte, onde será efetuado um enquadramento histórico, apresentando o processo de fabrico destes elementos e o tipo de elementos estruturais originados, concluindo-se com as vantagens/desvantagens dos perfis em aço enformados a frio. Os conceitos teóricos de estabilidade estrutural, os tipos de instabilidade mais comuns nestes elementos, bem como os tipos de análise destes fenómenos farão a ponte com o capítulo que se segue. Relativamente ao dimensionamento destes elementos, será dado enfâse às metodologias preconizadas pelo Eurocódigo 3, Parte 1-3. Este capítulo incidirá, entre outos, nas propriedades das secções transversais, na determinação da resistência destas, onde se contabilizará os efeitos das instabilidades locais de placa e distorcionais, na instabilidade global dos perfis e nas ligações entre os mesmos. Será analisada, posteriormente, a abordagem apresentada pela ECCS relativamente ao dimensionamento de madres travadas por painéis de cobertura. Neste capítulo será apresentada a metodologia para o dimensionamento de vigas com restrição à torção e à translação, bem como a resistência da secção transversal da madre e do seu banzo livre à encurvadura. Finalmente, e ao encontro do que foi proposto pela empresa CCAD-Serviços de Engenharia, Lda, efetuar-se-á o dimensionamento de uma cobertura de um edifício de distribuição, cobertura esta constituída por asnas treliçadas e madres simples. Neste dimensionamento foram consideradas as ações segundo o Regulamento de Segurança e Ações Para Estruturas de Edifícios e Pontes e o Eurocódigo 1, Parte 1-1 que diz respeito às Ações Gerais em Estruturas e Parte 1-4 respeitante às Ações do vento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basidiomycetous yeast Cryptococcus neoformans is an important fungal pathogen mainly in immunocompromised patients. In this study, 47 clinical isolates of C. neoformans from regions of São Paulo State were studied serologically by using the Crypto Check Iatron RM 304-K kit, their genetic diversity was estimated by PCR-fingerprinting with a microsatellite-specific sequence (GACA)4, RAPD with primer 6 (Amersham Pharmacia Biotech), PCR-restriction fragment length polymorphism (RFLP) analysis of the phospholipase B gene (PLB1) digested with AvaI and mating type analysis by PCR. All 47 strains isolated from HIV positive patients included in this study were serotype A and MATalpha. The majority of the isolates (45/47) were VNI and only two were VNII by PCR-fingerprinting and PCR-RFLP analysis. High degree of homogeneity was observed when (GACA)4 was used, being highly correlated (> 0.9). In contrast, the RAPD analysis was more heterogeneous with higher number of molecular profiles. By PCR-RFLP, no new molecular type was found, enhancing the suggestion that the differences based on conserved gene as PLB1, can be resultant of ongoing divergent evolution within the C. neoformans complex, into the current eight subtypes. Our results furnish new information on the molecular epidemiology of C. neoformans in the southeast region of Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time, a glassy carbon electrode (GCE) modified with novel N-doped carbon nanotubes (CNT-N) functionalized with MnFe2O4 nanoparticles (MnFe2O4@CNT-N) has been prepared and applied for the electrochemical determination of caffeine (CF), acetaminophen (AC) and ascorbic acid (AA). The electrochemical behaviour of CF, AC and AA on the bare GCE, CNT-N/GCE and MnFe2O4@CNT-N/GCE were carefully investigated using cyclic voltammetry (CV) and square-wave voltammetry (SWV). Compared to bare GCE and CNT-N modified electrode, the MnFe2O4@CNT-N modified electrode can remarkably improve the electrocatalytic activity towards the oxidation of CF, AC and AA with an increase in the anodic peak currents of 52%, 50% and 55%, respectively. Also, the SWV anodic peaks of these molecules could be distinguished from each other at the MnFe2O4@CNT-N modified electrode with enhanced oxidation currents. The linear response ranges for the square wave voltammetric determination of CF, AC and AA were 1.0 × 10−6 to 1.1 × 10−3 mol dm−3, 1.0 × 10−6 to 1.0 × 10−3 mol dm−3 and 2.0 × 10−6 to 1.0 × 10−4 mol dm−3 with detection limit (S/N = 3) of 0.83 × 10−6, 0.83 × 10−6 and 1.8 × 10−6 mol dm−3, respectively. The sensitivity values at the MnFe2O4@CNT-N/GCE for the individual determination of AC, AA and CF and in the presence of the other molecules showed that the quantification of AA and CF show no interferences from the other molecules; however, AA and CF interfered in the determination of AC, with the latter molecule showing the strongest interference. Nevertheless, the obtained results show that MnFe2O4@CNT-N composite material acted as an efficient electrochemical sensor towards the selected biomolecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One parameter that influences the adhesively bonded joints performance is the adhesive layer thickness. Hence, its effect has to be investigated experimentally and should be taken into consideration in the design of adhesive joints. Most of the results from literature are for typical structural epoxy adhesives which are generally formulated to perform in thin sections. However, polyurethane adhesives are designed to perform in thicker sections and might have a different behavior as a function of adhesive thickness. In this study, the effect of adhesive thickness on the mechanical behavior of a structural polyurethane adhesive was investigated. The mode I fracture toughness of the adhesive was measured using double-cantilever beam (DCB) tests with various thicknesses of the adhesive layer ranging from 0.2 to 2 mm. In addition, single lap joints (SLJs) were fabricated and tested to assess the influence of adhesive thickness on the lap-shear strength of the adhesive. An increasing fracture toughness with increasing adhesive thickness was found. The lap-shear strength decreases as the adhesive layer gets thicker, but in contrast to joints with brittle adhesives the decrease trend was less pronounced.