948 resultados para Speckle tracking liver motion correction contrast-enhanced ultrasound


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the prevalence and risk factors of non-alcoholic fatty liver disease (NAFLD) in postmenopausal women.Methods A cross-sectional study was carried involving 188 women (age >= 45 years and amenorrhea >= 12 months) attending the outpatient unit in south-eastern Brazil. Exclusion criteria were liver disease (hepatitis B and C, cholestatic disease, liver insufficiency), use of drugs that affect liver metabolism; alcoholics; AIDS or cancer history; and morbid obesity. NAFLD was diagnosed by abdominal ultrasound. Clinical, anthropometric (body mass index, waist circumference) and biochemical variables were measured.Results Of the 188 women, 73 (38.8%) had NAFLD. Blood pressure, waist circumference, body mass index, LDL cholesterol, triglycerides and glucose were significantly higher in NAFLD patients when compared with women without NAFLD (control group) (p < 0.05). HOMA-IR values indicated insulin resistance only in the NAFLD group (6.1 +/- 4.6 vs. 2.4 +/- 1.4 in control group, p < 0.05). Metabolic syndrome was detected in 93.1% of the women affected by NAFLD, and 46.1% of the control group (p < 0.05). In multivariate analysis, adjusted for age and weight, the variables considered at risk for the development of NAFLD, were: high waist circumference (odds ratio (OR) 1.07, 95% confidence interval (CI) 1.01-1.13), insulin resistance (OR 3.81, 95% CI 2.01-7.13), and presence of metabolic syndrome (OR 8.68, 95% CI 3.3-24.1).Conclusion NAFLD showed a high prevalence among postmenopausal women. The presence of metabolic syndrome, abdominal obesity and IR were indicators of risk for the development of NAFLD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate abdominal ultrasound images of dogs diagnosed with lymphoma. Seventy cases of dogs with lymphoma were analyzed. The animals selected were diagnosed with lymphoma which was confirmed by citology or histopathology. The most common sonographic alterations were abdominal lymphadenopathy (57.1%), hepatomegaly (54.2%) and splenomegaly (51.4%). Of the animals that had a cytology done of superficial lymph nodes, 82,8% showed diffuse sonographic changes in the liver, 54.5% had normal sonographic appearance in the spleen and enlargement of the medial iliac lymph nodes. Considering the results, we conclude that canine lymphoma is a complex disease and that it requires several laboratory tests for a correct diagnosis and prognosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transient visual evoked cortical potentials (VECP) were recorded from the scalp of healthy normal trichromats (n = 12). VECPs were elicited by onset/offset presentation of patterned stimuli of two kinds: isochromatic luminance-modulated, and equiluminant red-green modulated, sine wave gratings. The amplitude and latency of the major onset components of the onset/offset VECP were measured and plotted as a function of the logarithm of pooled cone contrast. The early onset components, achromatic C1 and chromatic N1, increase linearly with log contrast, but N1 has a higher contrast gain than C1. The late onset components, achromatic C2 and chromatic N2, have similar contrast gain, and similar response as a function of contrast level: both increase in the low-to-medium range of contrasts and saturate at high contrast levels. In the range of pooled cone contrast tested, C1 and N1 show similar latencies, whilst C2 shows shorter latencies than N2. We suggest that C1 and N1 are generated by the same visual mechanism with high red-green contrast gain and low luminance contrast gain, whilst C2 and N2 are generated by different visual mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CLN is a frequent histological finding in biopsies after pediatric: LT, and its pathogenesis has not yet been fully clarified and has different causes. Among the vascular causes, VOB is sometimes difficult to diagnose, especially when technical variants such as split-liver, reduced-liver, or living-related LT are utilized. Three liver-transplanted malnourished children (ages 12, 20, and 28 months) developed altered LFTs and post-operative ascites with right pleural effusion (two cases) and jaundice (one case). Doppler ultrasound examinations were normal and liver biopsies showed CLN interpreted as severe ACR. There were no responses to the medical treatment. Additional investigation with CT angiography suggested obstructed hepatic vein drainage, which was confirmed by interventional radiology and angioplasty of the anastomosis between the hepatic vein and the inferior vena cava, with clinical and histological resolution. It is concluded that in malnourished children undergoing LT with technical variations, in which the occurrence of severe ACR is usually less common because of the severity of the patient condition, the finding of CLN should raise the possibility of VOB, so that excessive immunosuppression and its consequences can be avoided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intravascular ultrasound (IVUS) phantoms are important to calibrate and evaluate many IVUS imaging processing tasks. However, phantom generation is never the primary focus of related works; hence, it cannot be well covered, and is usually based on more than one platform, which may not be accessible to investigators. Therefore, we present a framework for creating representative IVUS phantoms, for different intraluminal pressures, based on the finite element method and Field II. First, a coronary cross-section model is selected. Second, the coronary regions are identified to apply the properties. Third, the corresponding mesh is generated. Fourth, the intraluminal force is applied and the deformation computed. Finally, the speckle noise is incorporated. The framework was tested taking into account IVUS contrast, noise and strains. The outcomes are in line with related studies and expected values. Moreover, the framework toolbox is freely accessible and fully implemented in a single platform. (E-mail: fernando.okara@gmail.com) (c) 2012 World Federation for Ultrasound in Medicine & Biology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. This study evaluated the influence of circulating anti-HLA antibodies on outcomes of 97 liver allografts from deceased donors. Methods. Human leukocyte antigen (HLA) antibody screening was performed by both complement-dependent cytotoxicity (CDC) and multiparameter Luminex microsphere-based assays (Luminex assay). Results. The agreements between T- and B- cell CDC and Luminex assays were 67% and 77% for pre- and posttransplant specimens, respectively. Graft dysfunction was not associated with either positive pretransplant CDC or Luminex panel-reactive antibody (PRA) values. Likewise, positive posttransplant T- or B- cell CDC PRA values were not associated with graft dysfunction. In contrast, posttransplant Luminex PRA values were significantly higher among patients with graft dysfunction compared with subjects with good outcomes (P = .017). Conclusion. Posttransplant monitoring of HLA antibodies with Luminex methodology allowed identification of patients at high-risk for poor graft outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective The aim of the present study was to investigate the lipid profiles of the hepatic and adipose tissues of Wistar rats treated for 21 days with a diet high in saturated fat (high saturated fat, n=6) or high in hydrogenated fat, that is, having 50% partially hydrogenated vegetable oil in its composition (high hydrogenated fat, n=6), and compare them to those of a control group (control group, n=6). Methods Adipose tissue and total hepatic fat were higher in the saturated fat group than in the hydrogenated fat group. Hepatic lipid peroxidation was greatest in the saturated fat group, with consequent lower hepatic vitamin E and A levels. In contrast, serum vitamin A was highest in the saturated fat group. Analysis of hepatic lipid fractions found more cholesterol and less high density lipoprotein-cholesterol in the hydrogenated fat group. The hydrogenated fat group had the highest levels of triacylglycerols, followed by the saturated fat group. Results Significant amounts of trans fatty acids were detected in the hepatic and adipose tissues of the hydrogenated fat group. Among the identified fatty acids, 18:1n9 had a higher positive association with hepatic cholesterol and triacylglycerols, and a higher negative association with high density lipoprotein-cholesterol. Partially hydrogenated vegetable oil promotes greater accumulation of cholesterol and triacylglycerols in the liver than saturated fats. Conclusion Trans fatty acids were incorporated into hepatocytes and adipocytes in a highly efficient manner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasonography has an inherent noise pattern, called speckle, which is known to hamper object recognition for both humans and computers. Speckle noise is produced by the mutual interference of a set of scattered wavefronts. Depending on the phase of the wavefronts, the interference may be constructive or destructive, which results in brighter or darker pixels, respectively. We propose a filter that minimizes noise fluctuation while simultaneously preserving local gray level information. It is based on steps to attenuate the destructive and constructive interference present in ultrasound images. This filter, called interference-based speckle filter followed by anisotropic diffusion (ISFAD), was developed to remove speckle texture from B-mode ultrasound images, while preserving the edges and the gray level of the region. The ISFAD performance was compared with 10 other filters. The evaluation was based on their application to images simulated by Field II (developed by Jensen et al.) and the proposed filter presented the greatest structural similarity, 0.95. Functional improvement of the segmentation task was also measured, comparing rates of true positive, false positive and accuracy. Using three different segmentation techniques, ISFAD also presented the best accuracy rate (greater than 90% for structures with well-defined borders). (E-mail: fernando.okara@gmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ability to induce apoptosis is an important marker for cytotoxic antitumor agents. Some natural compounds have been shown to modulate apoptosis pathways that are frequently blocked in human cancers, and therefore, these compounds provide novel opportunities for cancer drug development. Phyllanthus, a plant genus of the family Euphorbiaceae, exhibits multiple pharmacological actions. Of these, Phyllanthus niruri extracts exhibit significant antitumor activity, which is consistent with the traditional medicinal use of this plant. To examine the apoptotic effects of a spray-dried extract of P. niruri (SDEPN), human hepatocellular carcinoma cells (HepG2, Huh-7), colorectal carcinoma cells (Ht29) and keratinocytes (HaCaT) were exposed to the extract for 4, 8 and 24 h. Flow cytometry and caspase-3 immunostaining were used to detect apoptosis, while analysis of variance was applied to identify significant differences between groups (P < 0.05). At all timepoints, the SDEPN induced significantly different cytotoxic effects for HepG2 and Huh-7 cells compared with control cells (P < 0.001). In contrast, the SDEPN had a protective effect on HaCaT cells compared with control cells at all timepoints (P < 0.001). In caspase-3 assays, activation was detected after cell death was induced in Huh-7 and HepG2 cancer cells by the SDEPN. In combination, these results indicate that the SDEPN is selectively toxic towards cancer cell lines, yet is protective towards normal cells.