956 resultados para Solar heating.
Resumo:
Studies on the quality assessments of three traditional, rotary and solar tunnel dried SIS products were conducted. Organoleptic quality of traditional dried SIS products available in the markets was poor compared to those produced in rotary and solar tunnel dryer. Reconstitution of samples were in the range of 54.26% to 75.24%, 69.37% to 83.73% and 55.08% to 80.24% when soaked at 80°C for traditional, rotary and solar tunnel dried products, respectively. The percentage of reconstitution increased with the increase of soaking time and the uptake of water was maximum after 60 min of soaking. The moisture contents of traditional, rotary and solar tunnel dried products were in the range of 26.02% to 27.33%, 16.23% to 22.84% and 13.71% to 19.30%, respectively. The protein contents were in the range of 60.78% to 72.59%, 62.17% to 76.27% and 61.11% to 76.00%, respectively; lipid contents were in the range of 12.26% to 22.60%, 14.00% to 24.71% and 13.92% to 22.39%, respectively and ash contents in the range of 15.11% to 16.59%, 8.32% to 13.51% and 8.71% to 16.45%, respectively on dry matter basis. The TVB-N content of rotary and solar tunnel dried products was low compared to traditional one ranging from 10.64 to 17.52 mg/100g and 14.34 to 15.68 mg/100g, respectively whereas the TVB-N content of traditional samples was in the range of 15.46 to 20.36 mg/100g. The bacterial load of traditional, rotary and solar tunnel dried products were in the range of 1.43x10 super(8) CFU/g to 2.89 x10 super(80 CFU/g, 1.91x10 super(8) CFU/g to 2.84x10 super(8) CFU/g and 1.95x10 super(8) CFU/g to 2.59x10 super(8) CFU/g, respectively. The results of the study indicated that dried fish products from rotary dryer and solar tunnel dryer were found to be of better quality in nutritional and food quality aspects than those of traditional dried products.
Resumo:
A study was conducted on the shelf-life of rotary and solar tunnel dried SIS products under different packaging and storage conditions. Organoleptically dried products were found in good condition after a storage period of 60 days in ambient and chilled conditions. The moisture content, TVB-N value and bacterial load slightly increased during 60 days of storage in ambient and chilled conditions. The changes in moisture content and bacterial load were faster in ambient temperature than in chilled storage condition whereas changes in TVB-N value was higher in chilled condition than in ambient temperature. The initial moisture content was in the range of 13.71% to 22.84%. After 60 days of storage in ambient and chilled condition the moisture content of dried products was in the range of 15.09% to 25.11% and 14.49% to 25.01%, respectively. The initial TVB-N value was in the range of 10.64 to 17.52 mg/100g and after 60 days of storage in ambient and chilled condition, TVB-N value was in the range of 29.00 to 34.82 mg/100g and 31.41 to 39.11 mg/100g, respectively. The initial bacterial load was in the range of 1.91x10 super(8) to 2.84x10 super(8) and after 60 days of storage in ambient and chilled condition, the bacterial load was in the range of 6.2x10 super(8) to 1.8x10 super(9) and 5.75x10 super(7) to 5.05x10 super(8) CFU/g, respectively. The results of the present study indicated that it is necessary to store high quality dried products in sealed packed in chilled condition to ensure good quality up to a certain period of time.
Production of quality dried small indigenous fish species products using low cost solar tunnel drier
Resumo:
A low cost solar drier was constructed using locally available materials. The size of the drier was 20x3.6x3 having drying capacity of 80 kg of SIS (w/w). Optimization of moisture content was observed for mola, dhela, chapila, chanda and puti at temperature ranges between 40-45°C and 50-55°C in solar tunnel drier. There was little or no change in moisture content at temperature below 40°C during the first 3 hours. Then the moisture content declined gradually with the increase of drying period. On the other hand, at temperature between 50-55°C, moisture content started to decline after 2 hours of drying. The moisture content of the sample reached at about 16% after 26 hours of sun drying at 40-45°C and 20 hours at 50-55°C. The optimum temperature for producing high quality dried products was 45-50°C in solar tunnel drier. The temperature and relative humidity outside and inside the dryers (with fish) at various locations were recorded from 8.00am to 4.00pm. The normal atmospheric ambient temperature was recorded in the range of 25-37°C from at 8:00am to 4:00pm. During the same period the atmospheric relative humidity recorded was in the range of 30-58%. On the other hand, the maximum temperature inside the dryers was recorded in the range of 28-65°C. The lowest temperature recorded was 28°C in the morning and at 13.00pm the highest temperature 65°C was recorded. The maximum relative humidity 58% found in the afternoon and minimum of 28% at noon. There was inverse relationship between temperature intensity of sunshine and humidity which decreased as sunshine increased. In total, it took around 26 hours of drying to reduce the moisture level to about 16%.
Resumo:
The basic types of hybrid PV/thermal solar system and their performance were analyzed comparatively. The research method and recent developments of PV/T system were described. This paper gave some examples of PV/T products and demonstration project. Finally, some main problems, which should be solved in R&D of PV/T system, were presented and the outlook of PV/T technology was briefly discussed.
Resumo:
Building integrated photovoltaics (BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influence on the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. Four different roofs are used to assess the impacts of BIPV on the building's heating-and-cooling loads; namely ventilated air-gap BIPV, non-ventilated (closed) air-gap BIPV, closeroof mounted BIPV, and the conventional roof with no PV and no air gap. One-dimensional transient models of four cases are derived to evaluate the PV performances and building cooling-and-heating loads across the different roofs in order to select the appropriate PV building integration method in Tianjin, China. The simulation results show that the PV roof with ventilated air-gap is suitable for the application in summer because this integration leads to the low cooling load and high PV conversion efficiency. The PV roof with ventilation air-gap has a high time lag and small decrement factor in comparison with other three roofs and has the same heat gain as the cool roof of absorptance 0.4. In winter, BIPV of non-ventilated air gap is more appropriate due to the combination of the low heating-load through the PV roof and high PV electrical output. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
With the emergence of transparent electronics, there has been considerable advancement in n-type transparent semiconducting oxide (TSO) materials, such as ZnO, InGaZnO, and InSnO. Comparatively, the availability of p-type TSO materials is more scarce and the available materials are less mature. The development of p-type semiconductors is one of the key technologies needed to push transparent electronics and systems to the next frontier, particularly for implementing p-n junctions for solar cells and p-type transistors for complementary logic/circuits applications. Cuprous oxide (Cu2O) is one of the most promising candidates for p-type TSO materials. This paper reports the deposition of Cu2O thin films without substrate heating using a high deposition rate reactive sputtering technique, called high target utilisation sputtering (HiTUS). This technique allows independent control of the remote plasma density and the ion energy, thus providing finer control of the film properties and microstructure as well as reducing film stress. The effect of deposition parameters, including oxygen flow rate, plasma power and target power, on the properties of Cu2O films are reported. It is known from previously published work that the formation of pure Cu2O film is often difficult, due to the more ready formation or co-formation of cupric oxide (CuO). From our investigation, we established two key concurrent criteria needed for attaining Cu2O thin films (as opposed to CuO or mixed phase CuO/Cu2O films). First, the oxygen flow rate must be kept low to avoid over-oxidation of Cu2O to CuO and to ensure a non-oxidised/non-poisoned metallic copper target in the reactive sputtering environment. Secondly, the energy of the sputtered copper species must be kept low as higher reaction energy tends to favour the formation of CuO. The unique design of the HiTUS system enables the provision of a high density of low energy sputtered copper radicals/ions, and when combined with a controlled amount of oxygen, can produce good quality p-type transparent Cu2O films with electrical resistivity ranging from 102 to 104 Ω-cm, hole mobility of 1-10 cm2/V-s, and optical band-gap of 2.0-2.6 eV. These material properties make this low temperature deposited HiTUS Cu 2O film suitable for fabrication of p-type metal oxide thin film transistors. Furthermore, the capability to deposit Cu2O films with low film stress at low temperatures on plastic substrates renders this approach favourable for fabrication of flexible p-n junction solar cells. © 2011 Elsevier B.V. All rights reserved.
Resumo:
This paper describes a new strategy to make a full solid-state, flexible, dye-sensitized solar cell (DSSC) based on novel ionic liquid gel, organic dye, ZnO nanoparticles and carbon nanotube (CNT) thin film stamped onto a polyethylene terephthalate (PET) substrate. The CNTs serve both as the charge collector and as scaffolds for the growth of ZnO nanoparticles, where the black dye molecules are anchored. It opens up the possibility of developing a continuous roll to roll processing for THE mass production of DSSCs.
Resumo:
A voltage sensing buck converter-based technique for maximum solar power delivery to a load is presented. While retaining the features and advantages of the incremental conductance algorithm, this technique is more desirable because of single sensor use. The technique operates by maximising power at the buck converter output instead of the input.