816 resultados para Smart devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a distribution feeder simulation using VHDL-AMS, considering the standard IEEE 13 node test feeder admitted as an example. In an electronic spreadsheet all calculations are performed in order to develop the modeling in VHDL-AMS. The simulation results are compared in relation to the results from the well knowing MatLab/Simulink environment, in order to verify the feasibility of the VHDL-AMS modeling for a standard electrical distribution feeder, using the software SystemVision™. This paper aims to present the first major developments for a future Real-Time Digital Simulator applied to Electrical Power Distribution Systems. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we described for the first time the construction of a 25 μL electrochemical cell from low temperature co-fired ceramic (LTCC) material and carbon screen-printed electrode applicable in portable devices. Firstly, a carbon screen-printed electrode was prepared and characterized by cyclic voltammetry and scanning electron microscopy. Afterwards carbon polymeric film and metal pastes were dropped into the LTCC cell cavities in order to determine the device electrodes, and this arrangement was also electrochemically characterized. The great advantage of this promising device is the simple construction method and its widespread applicability in reusable portable devices. © 2013 The Royal Society of Chemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In dealing with computer networks, these allow the flow of information through the resources of various equipment's. This work describes the implementation through the encapsulation of Protocol DNP3, usually employed in Smart Grid communication, in a simulator of discrete events. The NS-2 is a simulator in open source of network events, that facilitate the development of communication networks scenarios considering the protocols involved, in wireless or wired technologies. The objective of this work is to develop the DNP3 protocol encapsulation over a TCP/IP in the in the discrete event Simulator NS-2, allowing an analysis of behavior of a middle or large network sized in Smart Grid applications. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Demand response has gained increasing importance in the context of competitive electricity markets and smart grid environments. In addition to the importance that has been given to the development of business models for integrating demand response, several methods have been developed to evaluate the consumers' performance after the participation in a demand response event. The present paper uses those performance evaluation methods, namely customer baseline load calculation methods, to determine the expected consumption in each period of the consumer historic data. In the cases in which there is a certain difference between the actual consumption and the estimated consumption, the consumer is identified as a potential cause of non-technical losses. A case study demonstrates the application of the proposed method to real consumption data. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents simulation results of the DNP3 communication protocol over a TCP/IP network, for Smart Grid applications. The simulation was performed using the NS-2 network simulator. This study aimed to use the simulation to verify the performance of the DNP3 protocol in a heterogeneous LAN. Analyzing the results it was possible to verify that the DNP3 over a heterogeneous traffic network, with communication channel capacity between 60 and 85 percent, it works well with low packet loss and low delay, however, with traffic values upper 85 percent, the DNP3 usage becomes unfeasible because the information lost, re-transmissions and latency are significantly increased. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acid mine drainage (AMD) is a serious environmental problem that creates acidic solution with high Mn concentrations. The speciation of residual Mn from AMD after an active treatment involving the addition of a neutralizing agent can reliably evaluate the treatment efficiency and provide knowledge of the Mn species being inputted into the environment. The aim of this study was to evaluate the in situ lability and speciation of Mn using the diffusive gradients in thin films (DGT) technique with treated drainage water from a uranium mine (TAMD). DGT devices with different binding phases (Chelex-100 and P81 and DE81membranes) were used to perform the in situ speciation of Mn. A comparison of the results from deploying DGT in the laboratory and in situ shows that the speciation of Mn in TAMD should be performed in situ. Linear deployment curves (from in situ experiments) indicate that the DGT device containing the Chelex-100 binding phase can be used to evaluate Mn lability in TAMD. The labile Mn fraction (from in situ measurements) obtained using the device containing the Chelex-100 resin ranged from 63 to 81% of the total Mn concentration and, when compared to the speciation obtained using the CHEAQS software, indicated that this device was capable of uptaking the free Mn2+ and a portion of the MnSO4(aq). The values obtained using the DGT technique were compared to those from on site solid phase extraction, and a good agreement was found between the results. The amount of negative Mn species sampled by DE81 device was insignificant (<1.5%) for all of the sites. Sites containing a relatively small amount of Ca (<40mgL-1) and measured using devices containing the P81 membrane agreed with the concentration predicted by the CHEAQS software for positive Mn species (Mn2+ and Mn(OH)+). Nevertheless, the speciation obtained using the CHEAQS software indicated that the concentrations of positive Mn species were underestimated for sites with relatively high Ca concentrations (>150mgL-1), which take place due to the saturation of binding sites in the P81 membrane. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Comunicação - FAAC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Smart Grids, a variety of new applications are available to users of the electrical system (from consumers to the electric system operators and market operators). Some applications such as the SCADA systems, which control generators or substations, have consequences, for example, with a communication delay. The result of a failure to deliver a control message due to noncompliance of the time constraint can be catastrophic. On the other hand, applications such as smart metering of consumption have fewer restrictions. Since each type of application has different quality of service requirements (importance, delay, and amount of data to transmit) to transmit its messages, the policy to control and share the resources of the data communication network must consider them. In this paper Markov Decision Process Theory is employed to determine optimal policies to explore as much as possible the availability of throughput in order to transmit all kinds of messages, considering the quality of service requirements defined to each kind of message. First a non-preemptive model is formulated and after that a preemptive model is derived. Numerical results are used to compare FIFO, non-preemptive and preemptive policies.