988 resultados para Sheppard, Jack, 1702-1724


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Collection : Les archives de la Révolution française ; 8.68

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. We describe an atypical case of a patient with Coats disease that re-emerged after 30 years, illustrating a previously poorly understood long-term evolution of the disease. Methods. A 20-year-old man consulted for visual acuity (VA) decrease in the left eye (LE) to 0.3. Fundus examination revealed an exudative lesion with telangiectasias in the superior peripheral retina compatible with the diagnosis of Coats disease. Results. The patient was treated with cryotherapy and argon laser. Visual acuity improved to 0.5 and remained stable during a 1-year follow-up. The patient did not seek further clinical follow-up. Thirty years later, he returned complaining of a progressive VA decrease in the LE. Snellen VA was measured to counting fingers. Fundus examination revealed stage 3A Coats disease with macular exudation and a serous retinal detachment in the inferior quadrants requiring the placement of an encircling band, external drainage, and cryotherapy of the vascular lesions. After 10 additional sessions of argon laser on the vascular malformations, exudation regressed further and best-corrected VA increased to 0.1 at the end of the follow-up period. Conclusions. Coats disease must be considered as a chronic disease, which necessitates a very long-term follow-up even in the absence of subjective visual loss. The disease can reawaken and recur with force in previously unaffected areas of the retina several decades later. The gold standard treatment consists of cryotherapy and argon laser. However, in cases of very important retinal exudation, surgical management with subretinal drainage may be necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Acte. 1724-04-03]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wild-type A75/17-Canine distemper virus (CDV) is a highly virulent strain, which induces a persistent infection in the central nervous system (CNS) with demyelinating disease. Wild-type A75/17-CDV, which is unable to replicate in cell lines to detectable levels, was adapted to grow in Vero cells and was designated A75/17-V. Sequence comparison between the two genomes revealed seven nucleotide differences located in the phosphoprotein (P), the matrix (M) and the large (L) genes. The P gene is polycistronic and encodes two auxiliary proteins, V and C, besides the P protein. The mutations resulted in amino acid changes in the P and V, but not in the C protein, as well as in the M and L proteins. Here, a rescue system was developed for the A75/17-V strain, which was shown to be attenuated in vivo, but retains a persistent infection phenotype in Vero cells. In order to track the recombinant virus, an additional transcription unit coding for the enhanced green fluorescent protein (eGFP) was inserted at the 3' proximal position in the A75/17-V cDNA clone. Reverse genetics technology will allow us to characterize the genetic determinants of A75/17-V CDV persistent infection in cell culture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer-aided diagnosis. This work proposes a fully-automatic method for measuring image quality of three-dimensional (3D) structural MRI. Quality measures are derived by analyzing the air background of magnitude images and are capable of detecting image degradation from several sources, including bulk motion, residual magnetization from incomplete spoiling, blurring, and ghosting. The method has been validated on 749 3D T(1)-weighted 1.5T and 3T head scans acquired at 36 Alzheimer's Disease Neuroimaging Initiative (ADNI) study sites operating with various software and hardware combinations. Results are compared against qualitative grades assigned by the ADNI quality control center (taken as the reference standard). The derived quality indices are independent of the MRI system used and agree with the reference standard quality ratings with high sensitivity and specificity (>85%). The proposed procedures for quality assessment could be of great value for both research and routine clinical imaging. It could greatly improve workflow through its ability to rule out the need for a repeat scan while the patient is still in the magnet bore.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although prosthetic joint infection (PJI) is a rare event after arthroplasty, it represents a significant complication that is associated with high morbidity, need for complex treatment, and substantial healthcare costs. An accurate and rapid diagnosis of PJI is crucial for treatment success. Current diagnostic methods in PJI are insufficient with 10-30% false-negative cultures. Consequently, there is a need for research and development into new methods aimed at improving diagnostic accuracy and speed of detection. In this article, we review available conventional diagnostic methods for the diagnosis of PJI (laboratory markers, histopathology, synovial fluid and periprosthetic tissue cultures), new diagnostic methods (sonication of implants, specific and multiplex PCR, mass spectrometry) and innovative techniques under development (new laboratory markers, microcalorimetry, electrical method, reverse transcription [RT]-PCR, fluorescence in situ hybridization [FISH], biofilm microscopy, microarray identification, and serological tests). The results of highly sensitive diagnostic techniques with unknown specificity should be interpreted with caution. The organism identified by a new method may represent a real pathogen that was unrecognized by conventional diagnostic methods or contamination during specimen sampling, transportation, or processing. For accurate interpretation, additional studies are needed, which would evaluate the long-term outcome (usually >2 years) with or without antimicrobial treatment. It is expected that new rapid, accurate, and fully automatic diagnostic tests will be developed soon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sens dubte la 'idea de progés', tot i els precedents més o menys llunyans que puguin assenyalar-se, té la seva formulació filosòfica definitiva en el marc del projecte reformador, educador i culturitzador del segle XVIII i, per tant, constituieix una idea genuïnament i tòpicament 'il·lustrada'. En aquest punt, com en altres, Kant ocupa una posició peculiar en l'època: la seva assumpicó radical del principi crític de sotmetre tot fet o creença al 'tribunal de la raó' per tal de mostrar els límits de les nostres facultats, el portà no sols a qüestionar molts dels supòsits i tòpics metafísics del pensament tradicional, sino també dels seus mateixos contemporànis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present communication is to emphasize that some variations of the measured delta(13)C and delta(18)O values are apparent, and due to analytical interferences caused by the presence of sulfur and organosulfur compounds in the analyzed carbonates. This is particularly relevant for isotopic studies on carbonate-hosted mineral deposits, where the nearly ubiquitous association of the host carbonates with organic matter and sulfides can certainly affect the metallogenetic interpretations. In this work two methods were used to overcome the disturbing effects of sulfides and organic matter: (1) sample pretreatment following the method proposed by Charef and Sheppard (1984), combining the oxidation of organic matter with sodium hypochlorite and trapping of the sulfur species with silver phosphate; and (2) laser-based microprobe extraction. Apparent isotopic variations in sparry dolomite from a single hand sample of zebra ore from the MVT Zn-Pb deposit, San Vicente, central Peru, are as large as 6 parts per thousand delta(13)C and 4 parts per thousand delta(18)O. These variations are reduced to several tenths of a per mil when the samples are pretreated. A careful examination of the effects of treatment with NaOCl and/or Ag3PO4 in relation to the concentration of sulfide inclusions indicates that the main disturbing effects for delta(13)C values are the presence of sulfur species and organic matter, whereas the delta(18)O values are mainly affected by the presence of sulfides. Fine- and medium-grained replacement carbonates from MVT and other sediment-hosted base metal deposits are potentially the most affected during isotope analysis, due to the common presence of organic matter and sulfides. Using in situ laser microprobe techniques, it is possible to determine isotopic variations at a sub-millimeter scale. Our results show that laser extraction analysis allows a more precise sampling of the carbonate minerals, and minimizes contamination of the sample with sulfides and to some extent with intergrown organic matter. However, there is an isotopic shift associated with the laser extraction technique, of the order of 0.5-1 parts per thousand for delta(13)C and delta(18)O values.