900 resultados para SERUM-AMYLOID-A
Resumo:
The influence of fetal calf serum alone (FCS) or associated with proestrous (FCS+PCS), estrous (FCS+ECS) or metaestrous (FCS+MCS) cow serum added to the culture medium and of the steroids produced by co-cultured granulosa cells were evaluated in terms of the in vitro maturation (TVM) and fertilization (IVF) of bovine oocytes. Supplementation of the medium with FCS+ECS and FCS+MCS resulted in higher proportions of oocytes that reached metaphase II (96.0% and 93.3%, respectively) and in higher proportions of embryos that reached the four- and eight-cell/morula stages (51.9% and 65.6%, respectively), whereas the supplementation with FCS and FCS+PCS resulted in only 79.2% and 67.5%, respectively, of matured oocytes and 26.7% and 34.3%, respectively, of cleaved embryos. These findings show that the best IVM and IVF were obtained at lower concentrations of estradiol produced by co-cultured granulosa cells (supplementation with FCS+ECS: 10.3 ng/ml and FCS+MCS: 2.1 ng/ml), whereas the worst-results in IVM and IVF occurred at higher concentrations of estradiol that were obtained with FCS (33.1 ng/ml) and FCS+PCS (19.9 ng/ml) supplementation. These data suggest an inhibitory effect of estradiol on resumption of oocyte meiosis in vitro.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Nobiletin (NOB) and tangeretin (TAN), two of the main polymethoxylated flavones (PMFs) in citrus, influence a number of key biological pathways in mammalian cells. Although the impacts of NOB and TAN on glucose homeostasis and cholesterol regulation have been investigated in human clinical trials, much information is still lacking about the metabolism and oral bioavailability of these compounds in animals. In this study, NOB and TAN were administered to rats by gavage and intraperitoneal (ip) injection, and the blood serum concentrations of these compounds and their main metabolites were monitored by high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS). In addition to the administered compounds, two metabolites of TAN and eight metabolites of NOB were detected and measured over 24 h. With identical oral doses, nearly 10-fold higher absorption of NOB occurred compared to TAN. For both compounds, maximum levels of glucuronidated metabolites occurred in the blood serum at later time points (similar to 5-8 h) compared to the earlier T(max) a values for NOB and TAN. In most cases the glucuronides occurred at substantially higher concentrations than the aglycone metabolites. Low levels of NOB and TAN and their metabolites were detectable in rat blood serum even at 24 h after treatment.
Resumo:
Sodium monofluoroacetate (NAFAc) has been widely used for vertebrate pest control, such as rabbits in Australia. However NAFAc is extremely toxic to all vertebrates and its use is restricted. Although this compound is stringently restricted, the occurrence of accidental and homicidal poisoning is no ever-present possibility.The method developed in this work shows the applicability of SPE with alumina cartridges for the extraction of NAFAc from serum samples. The method is efficient with recoveries of at least 96.8% from spiked serum. The samples were subsequently derivatized with dicyclohexylcabodiimide (DCC), using 2,4-dichloroaniline (DCA), to make the product volatile for GC analysis.
Resumo:
An on-line dialysis flow system coupled to inductively coupled plasma mass spectrometry to determine trace elements in serum samples by isotope dilution is presented. Isotope dilution was performed on samples incubated with enriched Cu-65, Zn-66, Se-77 and Pb-206 for 24 h at 36degreesC prior to dialysis to quantified total element concentrations. The sample and acceptor solutions flowed through the dialysis unit with cellophane membrane placed in between the compartments. The serum sample (1 mL) was left to recycle in a closed path while the acceptor solution was continuously pumped along the dialyzer channel and through a cationic AG50W X-8 resin column. After 10 min, around 70% of Na, K and Cl migrate from the sample. Three replicate injections of 0.1 mL were performed for the clean sample after each separation step. The on-line coupling of the dialyzer to ICP-MS allowed isotope dilution for total element determination either in the cleaned sample or by eluting the cations retained in the resin to be carried out. Results demonstrated no matrix effects from alkaline elements or spectral interference from ArNa+ on Cu-63, ArCl+ on Se-77 and (SO2+)-S-34 on Zn-66. The precision of isotope ratio measurements for Cu and Zn was around 1% and for Se and Pb was around 2.5%. The values found for the reference serum sample IMEP-17 were in good agreement with the certified values for Cu, Zn and Se.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)