893 resultados para Rapid assessment method
Resumo:
An Iowa D.O.T. Laboratory built machine was constructed for the chloride permeability testing of concrete by measuring electric current through a specimen between a salt solution and a base solution. This study had two purposes. The first was to evaluate the machine's performance. To do this, three concrete mixes were made consisting of different cement factors and water/cement ratios. Each mix was tested for chloride ion content by the 90- day salt ponding method and for chloride permeability at a 28-day cure by the permeability machine. The results from each test were evaluated to see if there was correlation between chloride ion content and the chloride permeability. It was determined that there was a correlation and that the permeability machine was satisfactory for determining chloride permeability in concrete. The second purpose of this study was to examine the effects that pozzolans have on the chloride permeability of concrete. Four mixes were made: one without any pozzolans as a control, one with class C fly ash, one with class F fly ash, and one with silica fume. Specimens from each mix were evaluated for chloride ion content by the 90-day salt ponding test and by the laboratory built machine for chloride permeability after curing 28 days. Specimens from these mixes were also taken from the salt ponding slabs after completion of the ponding test to examine the effect chloride ion content has on the operation of the chloride permeability machine. Specimens containing pozzolans were also examined for chloride permeability after a cure of 180 days. It was determined that the addition of pozzolans to concrete lowers the chloride permeability as measured by the permeability machine. Class F fly ash and silica fume in the concrete had a major effect in lowering the chloride permeability in concrete as measured by the permeability machine.
Resumo:
Introduction: Growth is a central process in paediatrics. Weight and height evaluation are therefore routine exams for every child but in some situation, particularly inflammatory bowel disease (IBD), a wider evaluation of nutritional status needs to be performed. The assessment of body composition is essential in order to maintain acceptable growth using the following techniques: Dual-energy X-ray absorptiometry (DEXA), bio-impedance-analysis (BIA) and anthropometric measurements (skinfold thickness skin), the latter being most easily available and most cost effective. Objectives: To assess the accuracy of skinfold equations in estimating percentage body fat (%BF) in children with inflammatory bowel disease (IBD), compared with assessment of body fat dual energy X-ray absorptiometry (DEXA). Methods: Twenty-one patients (11 females, 10 males; mean age: 14.3 years, range 12 - 16 years) with IBD (Crohn's disease n = 15, ulcerative colitis n = 6)). Estimated%BF was computed using 6 established equations based on the triceps, biceps, subscapular and suprailiac skinfolds (Deurenberg, Weststrate, Slaughter, Durnin & Rahaman, Johnston, Brook) and compared to DEXA. Concordance analysis was performed using Lin's concordance correlation and the Bland-Altman limits of agreement method. Results: Durnin & Rahaman's equation shows a higher Lin's concordance coefficient with a small difference amongst raw values for skinfolds and DEXA compared to the other equations. Correlation coefficient between mean and difference is close to zero with a non-significant Bradley-Blackwood test. Conclusion: Body composition in paediatric IBD patients using the Durnin & Rahaman skinfold-equation adequately reflects values obtained by DEXA.
Resumo:
Assessing the total energy expenditure (TEE) and the levels of physical activity in free-living conditions with non-invasive techniques remains a challenge. The purpose of the present study was to investigate the accuracy of a new uniaxial accelerometer for assessing TEE and physical-activity-related energy expenditure (PAEE) over a 24 h period in a respiratory chamber, and to establish activity levels based on the accelerometry ranges corresponding to the operationally defined metabolic equivalent (MET) categories. In study 1, measurement of the 24 h energy expenditure of seventy-nine Japanese subjects (40 (SD 12) years old) was performed in a large respiratory chamber. During the measurements, the subjects wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd, Nagoya, Japan) on their belt. Two moderate walking exercises of 30 min each were performed on a horizontal treadmill. In study 2, ten male subjects walked at six different speeds and ran at three different speeds on a treadmill for 4 min, with the same accelerometer. O2 consumption was measured during the last minute of each stage and was expressed in MET. The measured TEE was 8447 (SD 1337) kJ/d. The accelerometer significantly underestimated TEE and PAEE (91.9 (SD 5.4) and 92.7 (SD 17.8) % chamber value respectively); however, there was a significant correlation between the two values (r 0.928 and 0.564 respectively; P<0.001). There was a strong correlation between the activity levels and the measured MET while walking (r(2) 0.93; P<0.001). Although TEE and PAEE were systematically underestimated during the 24 h period, the accelerometer assessed energy expenditure well during both the exercise period and the non-structured activities. Individual calibration factors may help to improve the accuracy of TEE estimation, but the average calibration factor for the group is probably sufficient for epidemiological research. This method is also important for assessing the diurnal profile of physical activity.
Resumo:
Purpose: Despite the fundamental role of ecosystem goods and services in sustaining human activities, there is no harmonized and internationally agreed method for including them in life cycle assessment (LCA). The main goal of this study was to develop a globally applicable and spatially resolved method for assessing land-use impacts on the erosion regulation ecosystem service.Methods: Soil erosion depends much on location. Thus, unlike conventional LCA, the endpoint method was regionalized at the grid-cell level (5 arc-minutes, approximately 10×10 km2) to reflect the spatial conditions of the site. Spatially explicit characterization factors were not further aggregated at broader spatial scales. Results and discussion: Life cycle inventory data of topsoil and topsoil organic carbon (SOC) losses were interpreted at the endpoint level in terms of the ultimate damage to soil resources and ecosystem quality. Human health damages were excluded from the assessment. The method was tested on a case study of five three-year agricultural rotations, two of them with energy crops, grown in several locations in Spain. A large variation in soil and SOC losses was recorded in the inventory step, depending on climatic and edaphic conditions. The importance of using a spatially explicit model and characterization factors is shown in the case study.Conclusions and outlook: The regionalized assessment takes into account the differences in soil erosion-related environmental impacts caused by the great variability of soils. Taking this regionalized framework as the starting point, further research should focus on testing the applicability of the method trough the complete life cycle of a product and on determining an appropriate spatial scale at which to aggregate characterization factors, in order to deal with data gaps on location of processes, especially in the background system. Additional research should also focus on improving reliability of the method by quantifying and, insofar as it is possible, reducing uncertainty.
Resumo:
BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.
Resumo:
A comprehensive field detection method is proposed that is aimed at developing advanced capability for reliable monitoring, inspection and life estimation of bridge infrastructure. The goal is to utilize Motion-Sensing Radio Transponders (RFIDS) on fully adaptive bridge monitoring to minimize the problems inherent in human inspections of bridges. We developed a novel integrated condition-based maintenance (CBM) framework integrating transformative research in RFID sensors and sensing architecture, for in-situ scour monitoring, state-of-the-art computationally efficient multiscale modeling for scour assessment.
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
The ability of a PCR-based restriction fragment length polymorphism (RFLP) analysis of the cytochrome b (mtDNA) to distinguish Apodemus alpicola from two other Apodemus species was investigated. The partial sequencing of the cytochrome b allowed the identification of one enzyme as being potentially diagnostic. This was supported by an analysis of 131 specimens previously identified using morphometric and/or allozymic data, indicating that the PCR-based RFLP method provides a rapid and reliable tool for distinguishing A. alpicola from its two co-occurring congenerics. The method is applicable to samples taken in the field for ecological studies, and could easily be adapted to the identification of museum samples.
Resumo:
OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.
Resumo:
The value of various indexes to characterize the stimulus-response curve of human motor nerves was assessed in 40 healthy subjects recruited from four European centers of investigation (Créteil, Lausanne, Liège, Marseille). Stimulus-response curves were established by stimulating the right median and ulnar motor nerves at the wrist, with stimulus durations of 0.05 and 0.5 ms. The following parameters were studied: the threshold intensity of stimulation to obtain 10% (I 10), 50% (I 50), and 90% (I 90) of the maximal compound muscle action potential, the ratios I 10/I 50, I 90/I 50, (I 90 - I 10)/I 10, (I 90-I 50)/I 50, and (I 50 - I 10)/I 10, and the slopes of the stimulus-response curves with or without normalization to I 50. For each parameter, within-center variability and reproducibility (in a test-retest study) were assessed and between-center comparisons were made. For most of the parameters, the results varied significantly within and between the centers. Within the centers, only the ratios I 10/I 50 and I 90/I 50 were found constant and reproducible. Between the centers, the absolute intensity thresholds (I 10, I 50, I 90) and the ratio I 90/I 50 did not show significant differences at stimulus duration of 0.5 ms, whatever the stimulated nerve. The reduced variability and good reproducibility of the ratios I 10/I 50 and I 90/I 50 open perspectives in neurophysiological practice for the use of these indexes of the stimulus-response curve, a rapid and noninvasive test.
Resumo:
The Learning Affect Monitor (LAM) is a new computer-based assessment system integrating basic dimensional evaluation and discrete description of affective states in daily life, based on an autonomous adapting system. Subjects evaluate their affective states according to a tridimensional space (valence and activation circumplex as well as global intensity) and then qualify it using up to 30 adjective descriptors chosen from a list. The system gradually adapts to the user, enabling the affect descriptors it presents to be increasingly relevant. An initial study with 51 subjects, using a 1 week time-sampling with 8 to 10 randomized signals per day, produced n = 2,813 records with good reliability measures (e.g., response rate of 88.8%, mean split-half reliability of .86), user acceptance, and usability. Multilevel analyses show circadian and hebdomadal patterns, and significant individual and situational variance components of the basic dimension evaluations. Validity analyses indicate sound assignment of qualitative affect descriptors in the bidimensional semantic space according to the circumplex model of basic affect dimensions. The LAM assessment module can be implemented on different platforms (palm, desk, mobile phone) and provides very rapid and meaningful data collection, preserving complex and interindividually comparable information in the domain of emotion and well-being.
Resumo:
The use of herbicides in agriculture may lead to environmental problems, such as surface water pollution, with a potential risk for aquatic organisms. The herbicide glyphosate is the most used active ingredient in the world and in Switzerland. In the Lavaux vineyards it is nearly the only molecule applied. This work aimed at studying its fate in soils and its transfer to surface waters, using a multi-scale approach: from molecular (10-9 m) and microscopic scales (10-6 m), to macroscopic (m) and landscape ones (103 m). First of all, an analytical method was developed for the trace level quantification of this widely used herbicide and its main by-product, aminomethylphosphonic acid (AMPA). Due to their polar nature, their derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was done prior to their concentration and purification by solid phase extraction. They were then analyzed by ultra performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS). The method was tested in different aqueous matrices with spiking tests and validated for the matrix effect correction in relevant environmental samples. Calibration curves established between 10 and 1000ng/l showed r2 values above 0.989, mean recoveries varied between 86 and 133% and limits of detection and quantification of the method were as low as 5 and 10ng/l respectively. At the parcel scale, two parcels of the Lavaux vineyard area, located near the Lutrive River at 6km to the east of Lausanne, were monitored to assess to which extent glyphosate and AMPA were retained in the soil or exported to surface waters. They were equipped at their bottom with porous ceramic cups and runoff collectors, which allowed retrieving water samples for the growing seasons 2010 and 2011. Results revealed that the mobility of glyphosate and AMPA in the unsaturated zone was likely driven by the precipitation regime and the soil characteristics, such as slope, porosity structure and layer permeability discrepancy. Elevated glyphosate and AMPA concentrations were measured at 60 and 80 cm depth at parcel bottoms, suggesting their infiltration in the upper parts of the parcels and the presence of preferential flow in the studied parcels. Indeed, the succession of rainy days induced the gradual saturation of the soil porosity, leading to rapid infiltration through macropores, as well as surface runoff formation. Furthermore, the presence of more impervious weathered marls at 100 cm depth induced throughflows, the importance of which for the lateral transport of the herbicide molecules was determined by the slope steepness. Important rainfall events (>10 mm/day) were clearly exporting molecules from the soil top layer, as indicated by important concentrations in runoff samples. A mass balance showed that total loss (10-20%) mainly occurred through surface runoff (96%) and, to a minor extent, by throughflows in soils (4%), with subsequent exfiltration to surface waters. Observations made in the Lutrive River revealed interesting details of glyphosate and AMPA dynamics in urbanized landscapes, such as the Lavaux vineyards. Indeed, besides their physical and chemical properties, herbicide dynamics at the catchment level strongly depend on application rates, precipitation regime, land use and also on the presence of drains or constructed channels. Elevated concentrations, up to 4970 ng/l, observed just after the application, confirmed the diffuse export of these compounds from the vineyard area by surface runoff during main rain events. From April to September 2011, a total load of 7.1 kg was calculated, with 85% coming from vineyards and minor urban sources and 15% from arable crops. Small vineyard surfaces could generate high concentrations of herbicides and contribute considerably to the total load calculated at the outlet, due to their steep slopes (~10%). The extrapolated total amount transferred yearly from the Lavaux vineyards to the Lake of Geneva was of 190kg. At the molecular scale, the possible involvement of dissolved organic matter (DOM) in glyphosate and copper transport was studied using UV/Vis fluorescence spectroscopy. Combined with parallel factor (PARAFAC) analysis, this technique allowed characterizing DOM of soil and surface water samples from the studied vineyard area. Glyphosate concentrations were linked to the fulvic-like spectroscopic signature of DOM in soil water samples, as well as to copper, suggesting the formation of ternary complexes. In surface water samples, its concentrations were also correlated to copper ones, but not in a significant way to the fulvic-like signature. Quenching experiments with standards confirmed field tendencies in the laboratory, with a stronger decrease in fluorescence intensity for fulvic-like fluorophore than for more aromatic ones. Lastly, based on maximum concentrations measured in the river, an environmental risk for these compounds was assessed, using laboratory tests and ecotoxicity data from the literature. In our case and with the methodology applied, the risk towards aquatic species was found negligible (RF<1).
Resumo:
MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer-aided diagnosis. This work proposes a fully-automatic method for measuring image quality of three-dimensional (3D) structural MRI. Quality measures are derived by analyzing the air background of magnitude images and are capable of detecting image degradation from several sources, including bulk motion, residual magnetization from incomplete spoiling, blurring, and ghosting. The method has been validated on 749 3D T(1)-weighted 1.5T and 3T head scans acquired at 36 Alzheimer's Disease Neuroimaging Initiative (ADNI) study sites operating with various software and hardware combinations. Results are compared against qualitative grades assigned by the ADNI quality control center (taken as the reference standard). The derived quality indices are independent of the MRI system used and agree with the reference standard quality ratings with high sensitivity and specificity (>85%). The proposed procedures for quality assessment could be of great value for both research and routine clinical imaging. It could greatly improve workflow through its ability to rule out the need for a repeat scan while the patient is still in the magnet bore.
Resumo:
RESUME : Valganciclovir (Valcyte®) is an orally administered ester prodrug of the standard anticytomegalovirus (CMV) drug ganciclovir. This drug enabled an important reduction of the burden of CMV morbidity and mortality in solid organ transplant recipients. Prevention of CMV infection and treatment of CMV disease requires drug administration during many weeks. Oral drug administration is therefore convenient. Valganciclovir has been developed to overcome the poor oral availability of ganciclovir, which limits its concentration exposure after oral administration and thus its efficacy. This prodrug crosses efficiently the intestinal barrier, is then hydrolyzed into ganciclovir, providing exposure similar to intravenous ganciclovir. Valganciclovir is now preferred for the prophylaxis and treatment of CMV infection in solid organ transplant recipients. Nevertheless, adequate dosage adjustment is necessary to optimize its use, avoiding either insufficient or exaggerate exposure related to differences in its pharmacokinetic profile between patients. The main goal of this thesis was to better describe the pharmacokinetic and pharmacodynamic profile of valganciclovir in solid organ transplant recipients, to assess their reproducibility and their predictability, and thus to evaluate the current recommendations for valganciclovir dosage adjustment and the potential contribution of routine therapeutic drug monitoring (TDM) to patients' management. A total of 437 ganciclovir plasma concentration data from 65 transplant patients (41 kidney, 12 lung, 10 heart and 2 liver recipients, 58 under oral valganciclovir prophylaxis, 8 under oral valganciclovir treatment and 2 under intravenous ganciclovir) were measured using a validated chromatographic method (HPLC) developed for this study. The results were analyzed by non-linear mixed effect modeling (NONMEM). A two-compartment model with first-order absorption appropriately described the data. Systemic clearance was markedly influenced by GFR, with further differences between graft types and sex (CL/GFR = 1.7 in kidney, 0.9 in heart and 1.2 in lung and liver recipients) with interpatient variability (CV%) of 26% and interoccasion variability of 12%. Body weight and sex influenced central volume of distribution (V1 = 0.34 l/kg in males and 0.27 l/kg in females) with an interpatient variability of 20%. Residual intrapatient variability was 21 %. No significant drug interaction influenced GCV disposition. VGC prophylactic efficacy and tolerability were good, without detectable dependence on GCV profile. In conclusion, this analysis highlights the importance of thorough adjustment of VGC dosage to renal function and body weight. Considering the good predictability and reproducibility of GCV profile after oral VGC in solid organ transplant recipients, routine TDM does not appear to be clinically indicated. However, GCV plasma measurement may still be helpful in specific clinical situations such as documentation of appropriate exposure in patients with potentially compromised absorption, or lack of response to CMV disease treatment, or under renal replacement therapy. RESUME : Le valganciclovir (Valcyte®) est un promédicament oral du ganciclovir qui est un anti-infectieux de référence contre les infections à cytomegalovirus (CMV). Cet antiviral a permis de réduire les effets délétères de cette infection jusqu'ici responsable d'une importante morbidité et mortalité chez les transplantés d'organe. La prévention et le traitement de l'infection à CMV sont donc nécessaires mais requièrent l'administration d'un agent antiviral sur une longue période. Un médicament administré par voie orale représente donc un avantage évident. Le valganciclovir a été développé dans le but d'améliorer la faible absorption orale du ganciclovir, et donc son efficacité. Cet ester valylique du ganciclovir traverse plus facilement la barrière gastro-intestinale, puis est hydrolysé en ganciclovir dans la circulation sanguine, produisant une exposition comparable à celle d'une perfusion intraveineuse de ganciclovir. De ce fait, le valganciclovir est devenu largement utilisé pour la prophylaxie mais aussi le traitement de l'infection à CMV. Néanmoins une utilisation optimale de ce nouveau médicament nécessite de bonnes connaissances sur son profil pharmacocinétique afin d'établir un schéma de dose adapté pour éviter tant une surexposition qu'une sous-exposition résultant des différences d'élimination entre les patients. Le but de cette thèse a été d'étudier le profil pharmacocinétique et pharmacodynamique du valganciclovir chez les transplantés d'organe ainsi que sa reproductibilité et sa prédictibilité. Il s'agissait d'apprécier de manière critique le schéma actuellement recommandé pour l'adaptation des doses de valganciclovir, mais aussi la contribution éventuelle d'un suivi des concentrations sanguines en routine. Un total de 437 taux sanguins de ganciclovir ont été mesurés, provenant de 65 patients transplantés d'organe (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques, 58 sous une prophylaxie orale de valganciclovir, 8 sous un traitement de valganciclovir et 2 sous un traitement intraveineux). Une méthode de chromatographie liquide à haute performance a été développée et validée pour cette étude. Les résultats ont été ensuite analysés par modélisation non linéaire à effets mixtes (NONMEM). Un modèle à deux compartiments avec absorption de premier ordre a permis de décrire les données. La clairance systémique était principalement influencée par le débit de filtration glomérulaire (GFR), avec une différence entre les types de greffe et les sexes (CL/GFR = 1.7 chez les greffés rénaux, 0.9 pour les greffés cardiaques et 1.2 pour le groupe des greffés pulmonaires et hépatiques) avec un variabilité inter-individuelle de 26% (CV%) et une variabilité inter-occasion de 12%. Le poids corporel ainsi que le sexe avaient une influence sur le volume central de distribution (V1 = 0.34 l/kg chez les hommes et 0.27 l/kg chez les femmes) avec une variabilité inter-individuelle de 20%. La variabilité intra-individuelle résiduelle était de 21 %. Aucune interaction médicamenteuse n'a montré d'influence sur le profil du ganciclovir. La prophylaxie avec le valganciclovir s'est révélée efficace et bien tolérée. En conclusion, cette analyse souligne l'importance d'une adaptation de la dose du valganciclovir à la fonction rénale et au poids du patient. Au vu de la bonne reproductibilité et prédictibilité du profil pharmacocinétique du ganciclovir chez les patients transplantés recevant du valganciclovir, un suivi des concentrations sanguines en routine ne semble pas cliniquement indiqué. Néanmoins, la mesure des taux plasmatiques de ganciclovir peut être utile dans certaines situations particulières, comme la vérification d'une exposition appropriée chez des patients susceptibles d'absorption insuffisante, ou ne répondant pas au traitement d'une infection à CMV ou encore sous épuration extra-rénale. RESUME LARGE PUBLIC : Le valganciclovir est un précurseur capable de libérer du ganciclovir, récemment développé pour améliorer la faible absorption orale de ce dernier. Une fois le valganciclovir absorbé, le ganciclovir libéré dans la circulation sanguine devient efficace contre les infections à cytomégalovirus. Ce virus largement répandu est responsable de maladies insidieuses et parfois graves chez les personnes présentant une baisse des défenses immunitaires, comme les greffés d'organe recevant un traitement anti-rejet. Le ganciclovir est administré pendant plusieurs mois consécutifs soit pour prévenir une infection après la transplantation, soit pour traiter une infection déclarée. La facilité d'administration du valganciclovir par voie orale représente un avantage sur une administration du ganciclovir par perfusion, qui nécessite une hospitalisation. Toutefois, la voie orale peut être une source supplémentaire de variabilité chez les patients, avec un impact potentiel sur l'efficacité ou la toxicité du médicament. Le but de cette étude a été - de décrire le devenir de ce médicament dans le corps humain (dont l'étude relève de la discipline de la pharmacocinétique) - de définir les facteurs cliniques pouvant expliquer les différences de concentration sanguine observées entre les patients sous une posologie donnée - d'explorer les relations entre les concentrations du médicament dans le sang et son efficacité ou la survenue d'effets indésirables (dont l'étude relève de la discipline de la pharmacodynamie). Cette étude a nécessité le développement et la validation, d'une méthode d'analyse pour mesurer la concentration sanguine du ganciclovir, puis son application à 437 échantillons provenant de 65 patients transplantés d'organe solide (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques) recevant du valganciclovir. Les résultats des mesures effectuées ont été analysés à l'aide d'un outil mathématique afin d'élaborer un modèle du devenir du médicament dans le sang chez chaque patient et à chaque occasion. Cette étude a permis d'évaluer chez des patients recevant le valganciclovir, la vitesse à laquelle l'organisme absorbe, distribue, puis élimine le médicament. La vitesse d'élimination dépendait étroitement de la fonction rénale, du type de greffe et du sexe alors que la distribution dépendait du poids et du sexe du patient. La variabilité non expliquée par ces facteurs cliniques était modérée et vraisemblablement sans conséquence clinique évidente soit sur l'efficacité ou la tolérance, qui se révèlent très satisfaisantes chez les patients de l'étude. Les observations n'ont pas révélé de relation entre les concentrations de médicament et l'efficacité thérapeutique ou la survenue d'effets indésirables, confirmant que les doses relativement faibles utilisées dans notre collectif de patients suffisaient à produire une exposition reproductible à des concentrations adéquates. En conclusion, le profil (et par conséquent l'absorption) du valganciclovir chez les patients transplantés semble bien prédictible après une adaptation de la dose à la fonction rénale et au poids du patient. Un contrôle systématique des concentrations sanguines n'est probablement pas indiqué en routine, mais cette mesure peut présenter un intérêt dans certaines conditions particulières.
Resumo:
Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative method based on the detectability index (d') calculated for a non-prewhitened model observer with an eye filter (NPWE). The detectability index was calculated from the normalized noise power spectrum and image contrast, both measured from an image of a 5 cm poly(methyl methacrylate) phantom containing a 0.2 mm thick aluminium square, and the pre-sampling modulation transfer function. This was performed as a function of air kerma at the detector for 11 different digital mammography systems. These calculated d' values were compared against threshold gold thickness (T) results measured with the CDMAM test object and against derived theoretical relationships. A simple relationship was found between T and d', as a function of detector air kerma; a linear relationship was found between d' and contrast-to-noise ratio. The values of threshold thickness used to specify acceptable performance in the European Guidelines for 0.10 and 0.25 mm diameter discs were equivalent to threshold calculated detectability indices of 1.05 and 6.30, respectively. The NPWE method is a validated alternative to CDMAM scoring for use in the image quality specification, quality control and optimization of digital x-ray systems for screening mammography.