969 resultados para Radiology technician procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grafting of the maxillary sinus in both one- and two-stage protocols has become a highly predictable surgical technique for site development and for the placement of implants to support dentures. However, despite the predictability and high success rates reported for dental implants placed either simultaneously with or after a sinus floor elevation (SFE) procedure, complications have been reported. The aim of the following case report is to present an uncommon complication in a staged SFE procedure: the displacement of a dental implant into the maxillary sinus during insertion. As implant dentistry is becoming more and more popular among practitioners, and ever more demanding procedures for initial site development in jaws with bony deficiencies are being introduced into daily practice, the displacement of dental implants into the maxillary sinus during implant placement may become a more frequent complication. Management of this complication is presented, discussed, and evaluated in light of the current literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing evidence in animal models and clinical trials for stroke, hypoxic encephalopathy for children, and traumatic brain injury have shown that mild hypothermia may attenuate ischemic damage and improve neurological outcome. However, it is less clear if mild intraoperative hypothermia during vascular neurosurgical procedures results in improved outcomes for patients. This review examines the scientific evidence behind hypothermia as a treatment and discusses factors that may be important for the use of this adjuvant technique, including cooling temperature, duration of hypothermia, and rate of rewarming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying bronchopleural fistula along the coagulated former electrode track was diagnosed in two patients. In conclusion, delayed development of pneumothorax after pulmonary RF ablation can occur and is probably due to underlying bronchopleural fistula, potentially leading to tension pneumothorax. Patients and interventionalists should be prepared for delayed onset of this complication, and extensive track ablation following pulmonary RF ablation should be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Multiple organ failure is a common complication of acute circulatory and respiratory failure. We hypothesized that therapeutic interventions used routinely in intensive care can interfere with the perfusion of the gut and the liver, and thereby increase the risk of mismatch between oxygen supply and demand. DESIGN: Prospective, observational study. SETTING: Interdisciplinary intensive care unit (ICU) of a university hospital. PATIENTS: Thirty-six patients on mechanical ventilation with acute respiratory or circulatory failure or severe infection were included. INTERVENTIONS: Insertion of a hepatic venous catheter. MEASUREMENTS AND MAIN RESULTS: Daily nursing procedures were recorded. A decrease of >or=5% in hepatic venous oxygen saturation (Sho2) was considered relevant. Observation time was 64 (29-104) hours (median [interquartile range]). The ICU stay was 11 (8-15) days, and hospital mortality was 35%. The number of periods with procedures/patient was 170 (98-268), the number of procedure-related decreases in Sho2 was 29 (13-41), and the number of decreases in Sho2 unrelated to procedures was 9 (4-19). Accordingly, procedure-related Sho2 decreases occurred 11 (7-17) times per day. Median Sho2 decrease during the procedures was 7 (5-10)%, and median increase in the gradient between mixed and hepatic venous oxygen saturation was 6 (4-9)%. Procedures that caused most Sho2 decreases were airway suctioning, assessment of level of sedation, and changing patients' position. Sho2 decreases were associated with small but significant increases in heart rate and intravascular pressures. Maximal Sequential Organ Failure Assessment scores in the ICU correlated with the number of Sho2 decreases (r: .56; p < 0.001) and with the number of procedure-related Sho2 decreases (r: .60; p < 0.001). CONCLUSIONS: Patients are exposed to repeated episodes of impaired splanchnic perfusion during routine nursing procedures. More research is needed to examine the correlation, if any, between nursing procedures and hepatic venous desaturation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Along with the growing complexity of logistic chains the demand for transparency of informations has increased. The use of intelligent RFID-Technology offers the possibility to optimize and control all capacities in use, since it enables the identification and tracking of goods alongside the entire supply chain. Every single product can be located at any given time and a multitude of current and historical data can be transferred. The interaction of the flow of material and the flow of information between the various process steps can be optimized by using RFID-Technology since it guarantees that all required data is available at the right time and at the right place. The local accessibility and convertibility of data allows a flexible, decentralised control of logistic systems. As additional advantages of RFID-Components can be considered that they are individually writable and that their identification can be achieved over considerable distances even if there is no intervisibility between tag and reader. The use of RFID-Transponder opens up new potentials regarding process security, reduction of logistic costs or availability of products. These advantages depend on reliability of the identification processes. The undisputed potentials that are made accessible by the use of RFID-Elements can only be beneficial when the informations that are decentralised and attached to goods and loading equipment can be reliably retrieved at the required points. The communication between tag and reader can be influenced by different materials such as metal, that can disturbed or complicate the radio contact. The communications reliability is subject of various tests and experiments that analyse the effects of different filling materials as well as different alignments of tags on the loading equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND -Cardiac tamponade is the most dramatic complication observed during atrial fibrillation (AF) ablation and the leading cause of procedure-related mortality. Female gender is a known risk factor for complications during AF ablation; however, it is unknown whether women have a higher risk of tamponade. METHODS AND RESULTS -A systematic Medline search was used to locate academic electrophysiologic (EP) centers that reported cases of tamponade occurring during AF ablation. Centers were asked to provide information on cases of acute tamponade according to gender and their mode of management including any case of related mortality. Nineteen EP centers provided information on 34,943 ablation procedures involving 25,261 (72%) males. Overall 289 (0.9%) cases of tamponade were reported: 120 (1.24%) in females and 169 (0.67%) in males (odds ratio 1.83, P<0.001). There was a reciprocal association between center volume and the occurrence of tamponade with substantial lower risk in high volume centers. Most cases of tamponade occurred during catheter manipulation or ablation; females tended to develop more tamponades during transseptal catheterization. No gender difference in the mode of management was observed. However, 16% cases of tamponade required surgery with lower rates in high volume centers. Three cases of tamponade (1%) culminated in death. CONCLUSIONS -Tamponade during AF ablation procedures is relatively rare. Women have an almost twofold higher risk for developing this complication. The risk of tamponade among women decreases substantially in high volume centers. Surgical back-up and acute management skills for treating tamponade are important in centers performing AF ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large body of published work shows that proton (hydrogen 1 [(1)H]) magnetic resonance (MR) spectroscopy has evolved from a research tool into a clinical neuroimaging modality. Herein, the authors present a summary of brain disorders in which MR spectroscopy has an impact on patient management, together with a critical consideration of common data acquisition and processing procedures. The article documents the impact of (1)H MR spectroscopy in the clinical evaluation of disorders of the central nervous system. The clinical usefulness of (1)H MR spectroscopy has been established for brain neoplasms, neonatal and pediatric disorders (hypoxia-ischemia, inherited metabolic diseases, and traumatic brain injury), demyelinating disorders, and infectious brain lesions. The growing list of disorders for which (1)H MR spectroscopy may contribute to patient management extends to neurodegenerative diseases, epilepsy, and stroke. To facilitate expanded clinical acceptance and standardization of MR spectroscopy methodology, guidelines are provided for data acquisition and analysis, quality assessment, and interpretation. Finally, the authors offer recommendations to expedite the use of robust MR spectroscopy methodology in the clinical setting, including incorporation of technical advances on clinical units. © RSNA, 2014 Online supplemental material is available for this article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human face is a vital component of our identity and many people undergo medical aesthetics procedures in order to achieve an ideal or desired look. However, communication between physician and patient is fundamental to understand the patient’s wishes and to achieve the desired results. To date, most plastic surgeons rely on either “free hand” 2D drawings on picture printouts or computerized picture morphing. Alternatively, hardware dependent solutions allow facial shapes to be created and planned in 3D, but they are usually expensive or complex to handle. To offer a simple and hardware independent solution, we propose a web-based application that uses 3 standard 2D pictures to create a 3D representation of the patient’s face on which facial aesthetic procedures such as filling, skin clearing or rejuvenation, and rhinoplasty are planned in 3D. The proposed application couples a set of well-established methods together in a novel manner to optimize 3D reconstructions for clinical use. Face reconstructions performed with the application were evaluated by two plastic surgeons and also compared to ground truth data. Results showed the application can provide accurate 3D face representations to be used in clinics (within an average of 2 mm error) in less than 5 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Medical schools are charged with providing both a strong basic science and clinical curriculum for their students. In most institutions instruction in performing the core clinical procedures is part of the curriculum, but because of many constraints do medical students practice these procedures as many times as medical students in the past? Several studies have concluded that medical students today feel incompetent to perform basic clinical procedures at the time of graduation. [See PDF for complete abstract]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 3%. A pelvis phantom originally designed for use with photon treatments was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was measured. Hounsfield Units (HU) for each phantom material were measured with a CT scanner and compared to the relative stopping power calibration curve. The tissue equivalency for each material was calculated. Two proton treatment plans were created; one which did not correct for material SP differences (Plan 1) and one plan which did correct for SP differences (Plan 2). Film and TLD were loaded into the phantom and the phantom was irradiated 3 times per plan. The measured values were compared to the HU-SP calibration curve and it was found that the stopping powers for the materials could be underestimated by 5-10%. Plan 1 passed the criteria for the TLD and film margins with reproducibility under 3% between the 3 trials. Plan 2 failed because the right-left film dose profile average displacement was -9.0 mm on the left side and 6.0 mm on the right side. Plan 2 was intended to improve the agreements and instead introduced large displacements along the path of the beam. Plan 2 more closely represented the actual phantom composition with corrected stopping powers and should have shown an agreement between the measured and calculated dose within 5%/3mm. The hypothesis was rejected and the pelvis phantom was found to be not suitable to evaluate proton therapy treatment procedures.