998 resultados para Pulse repetition frequency
Resumo:
Optimization of the main parameters of SWASV using boron-doped diamond electrode was described for the simultaneous determination of Zn, Cd, Pb and Cu free in coconut water. The values of electroanalytical parameters studied were optimized with the factorial design and center composite design. The optimized parameters for the preconcentration of metals were -1.50 V for potential, and 240 s for deposition time. For SWV, the optimized value was 11.56 mV for step potential. In addition, frequency and pulse height were defined at 100 Hz and 55 mV, respectively. Furthermore, the concentration of the supporting electrolyte (acetate buffer, pH 4.7) was optimized in 0.206 mol L-1. The optimized procedure was applied in two samples of coconut water: natural and processed. The limits of detection (LOD) obtained for Zn, Cd, Pb and Cu were 7.2; 4.4; 3.3 and 1.5 µg L-1, respectively. The concentrations of Cd and Pb were not detected. On the other hand, the values found for the concentrations of Zn and Cu were: < LOD (29 µg L-1) and (6.8 ± 0.9) µg L-1 for the natural sample; and (85.8 ± 4.2) µg L-1 and (7.7 ± 0.6) µg L-1 for the processed sample, respectively.
Resumo:
Multilevel converters provide an attractive solution to bring the benefits of speed-controlled rotational movement to high-power applications. Therefore, multilevel inverters have attracted wide interest in both the academic community and in the industry for the past two decades. In this doctoral thesis, modulation methods suitable especially for series connected H-bridge multilevel inverters are discussed. A concept of duty cycle modulation is presented and its modification is proposed. These methods are compared with other well-known modulation schemes, such as space-vector pulse width modulation and carrier-based modulation schemes. The advantage of the modified duty-cycle modulation is its algorithmic simplicity. A similar mathematical formulation for the original duty cycle modulation is proposed. The modified duty cycle modulation is shown to produce well-formed phase-to-neutral voltages that have lower total harmonic distortion than the space-vector pulse width modulation and the duty cycle modulation. The space-vector-based solution and the duty cycle modulation, on the other hand, result in a better-quality line-to-line voltage and current waveform. The voltage of the DC links in the modules of the series-connected H-bridge inverter are shown to fluctuate while they are under load. The fluctuation causes inaccuracies in the voltage production, which may result in a failure of the flux estimator in the controller. An extension for upper-level modulation schemes, which changes the switching instants of the inverter so that the output voltage meets the reference voltage accurately regardless of the DC link voltages, is proposed. The method is shown to reduce the error to a very low level when a sufficient switching frequency is used. An appropriate way to organize the switching instants of the multilevel inverter is to make only one-level steps at a time. This causes restrictions on the dynamical features of the modulation schemes. The produced voltage vector cannot be rotated several tens of degrees in a single switching period without violating the above-mentioned one-level-step rule. The dynamical capabilities of multilevel inverters are analyzed in this doctoral thesis, and it is shown that the multilevel inverters are capable of operating even in dynamically demanding metal industry applications. In addition to the discussion on modulation schemes, an overvoltage in multilevel converter drives caused by cable reflection is addressed. The voltage reflection phenomenon in drives with long feeder cables causes premature insulation deterioration and also affects the commonmode voltage, which is one of the main reasons for bearing currents. Bearing currents, on the other hand, cause fluting in the bearings, which results in premature bearing failure. The reflection phenomenon is traditionally prevented by filtering, but in this thesis, a modulationbased filterless method to mitigate the overvoltage in multilevel drives is proposed. Moreover, the mitigation method can be implemented as an extension for upper-level modulation schemes. The method exploits the oscillations caused by two consecutive voltage edges so that the sum of the oscillations results in a mitigated peak of the overvoltage. The applicability of the method is verified by simulations together with experiments with a full-scale prototype.
Resumo:
Suomessa sähkönjakeluverkko koostuu pääasiassa 20 kV ja 400 V jännitetasoista. Tällöin sähkö viedään lähelle kuluttajia suuremmalla jännitetasolla ja muunnetaan alhaisemmaksi lähellä asiakkaita. Haittapuolena on se, että haja-asutusalueilla jakelumuuntajien määrä kasvaa suureksi, koska ne täytyy sijoittaa lähelle kuluttajaa. Vaihtoehtona on toteuttaa osa sähkönjakelusta tasajännitteellä, jolloin tehollinen jännite olisi suurempi. Tällöin sähköä voitaisiin siirtää pidempiä matkoja ilman, että asiakaskohtaisia tai muutaman asiakkaan kattavia 20 kV siirtolinjoja tarvitsisi käyttää. Tämä taasen edellyttää asiakaskohtaisien vaihtosuuntaajien käyttöä. Tässä työssä esiteltävällä 1 kVA vaihtosuuntaajalla muodostetaan tasasähköjakeluverkosta saatavasta 750 V tasasähköstä yksivaiheista (230 VRMS, 50 Hz) verkkojännitettä. Laite on suunniteltu toteuttamaan galvaaninen erotus mahdollisimman hyvän hyötysuhteen puitteissa. Vaihtosuuntaaja on toteutettu käyttämällä resonanssikonvertteria, joka vaihtosuuntaa jakelujännitteen korkeataajuiseksi vaihtojännitteeksi. Tämän jälkeen toteutetaan galvaaninen erotus käyttäen suurtaajuusmuuntajaa. Tätä seuraa syklokonvertteri, joka pulssintiheysmodulaatiota soveltaen muodostaa lähtöjännitteen. Tämä suodatetaan lopuksi LC- alipäästösuotimella säröltään standardin mukaiseksi. Laite on jaettu työssä kolmeen osaan, joista jokaisen toiminta on selitetty ja simuloitu itsenäisesti. Lopussa koko järjestelmä on simuloitu yhtenä kokonaisuutena. Hyötysuhteeksi arvioitiin karkeasti 94 % ja lopullisista tuloksista voidaan päätellä, että laitteen toteuttaminen prototyypiksi voisi olla kannattavaa.
Resumo:
This master’s thesis is focused on power supply network disturbances and their effects on the frequency converter – one of the components of modern process crane electrical system. The most critical disturbance types, their causes and the effect they bring to crane electrical system was determined in this work. Variety of protective devices used for mitigation of disturbances is investigated. Device protection solutions for the frequency converter used in crane applications are presented. Analyses of the power supply requirements for frequency converter and various components of crane electrical system were carried out and as a result the crane power supply requirements list that guarantees normal crane operation was built. This list is to be included in crane projects for troubleshooting purposes in order to determine potentially dangerous network.
Resumo:
The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.
Resumo:
The purpose of this study was to evaluate the efficiency of integrated managements on white mold control on common bean. Initially, in vitro testing was made to assess the antagonism of 11 Trichoderma isolates against Sclerotinia sclerotiorum and to investigate fungicides (fluazinam and procymidone) inhibitory effects on those fungi. In two field experiments the following combinations were tested: irrigation frequencies (seven or 14 days), plant densities (six or 12 plants per meter), and three disease controls (untreated control, fungicide or Trichoderma spp.). In a third experiment plant densities were replaced by grass mulching treatments (with or without mulching). Fluazinam was applied at 45 and 55 days after emergence (DAE). The antagonists T. harzianum (experiments 1 and 3) and T. stromatica (experiment 2) were applied through sprinkler irrigation at 10 and 25 DAE, respectively. Most of the Trichoderma spp. were effective against the pathogen in vitro. Fluazinam was more toxic than procymidone to both the pathogen and the antagonist. Fungicide applications increased yield between 32 % and 41 %. In field one application of Trichoderma spp. did not reduce disease intensity and did not increase yield. The reduction from 12 to six plants per meter did not decrease yield, and disease severity diminished in one of the two experiments. It is concluded that of the strategies for white mold control just reduction of plant density and applications of fungicide were efficient.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
Suomessa sähkönjakeluverkon pääasialliset jännitetasot ovat 20 kV ja 400 V. 20 kV jännitetasolla sähkö viedään lähelle kuluttajia ja muunnetaan pienemmäksi lähellä asiakkaita. Haittapuolena on se, että 20 kV avojohtosähkönsiirtoverkko on hyvin vika-altis ja usein yhden haaran vikaantuessa monta muutakin jää ilman sähköä. Lisäksi hintavien ja suurien jakelumuuntajien määrä on suuri. Vaihtoehtona on toteuttaa osa sähkönjakelusta tasajännitteellä, jolloin tehollinen pienjännite olisi 400 V:a suurempi. Tällöin sähköä voitaisiin siirtää pidempiä matkoja ilman, että asiakaskohtaisia tai muutaman asiakkaan kattavia 20 kV siirtolinjoja tarvitsisi käyttää. Tämä edellyttää vaihtosuuntauksen toteuttamista kuluttajan päässä. Tässä työssä esiteltävällä 1 kVA:n tehoisella vaihtosuuntaajalla muodostetaan tasasähköjakeluverkosta saatavasta 750 V tasasähköstä yksivaiheista (230 VRMS, 50 Hz) verkkojännitettä. Laite on suunniteltu toteuttamaan galvaaninen erotus mahdollisimman hyvällä hyötysuhteella. Suurtaajuusmuuntajan mitoitus mahdollisimman hyvälle hyötysuhteelle on haastava tehtävä, koska vaatimuksia sille asettavat sekä syöttävä resonanssikonvertteri että syötettävä syklokonvertteri. Mitoituksessa on pyrittävä löytämään mahdollisimman hyvä hyötysuhde kustannusten ja toteutettavuuden suhteen.
Resumo:
The intensity-duration-frequency occurrence ratio (IDF) is a tool commonly used for precipitation-runoff data transformation, which is established from observations of intense precipitations over a period sufficiently long as to allow the occurrence of extremes at the observation site. This study focused on verifying the existence or absence of new data, in terms of IDF ratio, by using partial duration records produced from data on maximum daily disaggregated rainfall for pre determined durations. The partial duration records considered a base value of 55 mm, totaling 279 values. After the rainfall series were established, their independence and seasonality were assessed. Using the Student's t-test statistics, it was established that no new data, as IDF ratio, emerged from the analysis of the partial duration series with the recommended base value of precipitation, as compared to the historical records.
Resumo:
The intensity, duration, and frequency relationship (IDF) of rainfall occurrence may be done through continuous records of pluviographs or daily pluviometer values . The objective of this study was to estimate the intensity-duration-frequency relationships of precipitation, using the method of daily rainfall disaggregation, at weather stations located to the southern half of the state of Rio Grande do Sul; comparing them with those obtained by rain gauge records, in places considered homogeneous from the meteorological point of view. The IDF equation parameters were estimated from daily rainfall disaggregation data, using the method of nonlinear optimization. To validate the equations confidence indices and efficiency and the "t" Student test, among maximum intensity values obtained from the disaggregated daily rainfall durations of 10; 30; 60 min and 6; 12 and 24 h and those extracted from existing IDF equations. For all studied stations and return periods, the trust index values were regarded as "optimal", i.e., greater than 0.85. The maximal intensity of rainfall obtained by daily rainfall disaggregation have similarity with those obtained by relations IDF standards. Thus, the method constitutes a feasible alternative in obtaining the IDF relationships.
Resumo:
Due to the lack of information concerning maximum rainfall equations for most locations in Mato Grosso do Sul State, the alternative for carrying out hydraulic work projects has been information from meteorological stations closest to the location in which the project is carried out. Alternative methods, such as 24 hours rain disaggregation method from rainfall data due to greater availability of stations and longer observations can work. Based on this approach, the objective of this study was to estimate maximum rainfall equations for Mato Grosso do Sul State by adjusting the 24 hours rain disaggregation method, depending on data obtained from rain gauge stations from Dourado and Campo Grande. For this purpose, data consisting of 105 rainfall stations were used, which are available in the ANA (Water Resources Management National Agency) database. Based on the results we concluded: the intense rainfall equations obtained by pluviogram analysis showed determination coefficient above 99%; and the performance of 24 hours rain disaggregation method was classified as excellent, based on relative average error WILMOTT concordance index (1982).
Resumo:
The Bartlett-Lewis Rectangular Pulse Modified (BLPRM) model simulates the precipitous slide in the hourly and sub-hourly and has six parameters for each of the twelve months of the year. This study aimed to evaluate the behavior of precipitation series in the duration of 15 min, obtained by simulation using the model BLPRM in situations: (a) where the parameters are estimated from a combination of statistics, creating five different sets; (b) suitability of the model to generate rain. To adjust the parameters were used rain gauge records of Pelotas/RS/Brazil, which statistics were estimated - mean, variance, covariance, autocorrelation coefficient of lag 1, the proportion of dry days in the period considered. The results showed that the parameters related to the time of onset of precipitation (λ) and intensities (μx) were the most stable and the most unstable were ν parameter, related to rain duration. The BLPRM model adequately represented the mean, variance, and proportion of the dry period of the series of precipitation lasting 15 min and, the time dependence of the heights of rain, represented autocorrelation coefficient of the first retardation was statistically less simulated series suitability for the duration of 15 min.
Resumo:
Tässä työssä tutkitaan LLC resonanssipiirin soveltuvuutta galvaanisen erotuksen toteuttamiseen tasasähkönjakeluverkon asiakaspäätelaitteessa. Tarkastellaan resonanssipiirin ominaisuuksia ja aikaisempia käyttökohteita. Tutkitaan piirin soveltuvuutta vaihtosähkö sovellukseen ja esitellään piirin toimintaa, häviöitä ja ohjausta. Esitellään pulssin leveys moduloitu (PWM) ja pulssin tiheys moduloitu (PDM) invertteri sovellukset ja näiden toimintaa. Esitetään vielä parannusehdotuksia ja kytkentäkuvio kytkennän ominaisuuksien ja hyö-tysuhteen parantamiseksi. Tutkimuksessa selvisi, että suora PDM topologia ei sovellu tähän käyttötarkoitukseen suuren suodin induktanssin vuoksi. PWM invertteri topologia jännitteen tasasuuntauksella taas sopii sovellukseen ja tällä rakenteella on mahdollista tehdä galvaaninen erotus hyvinkin hyvällä hyötysuhteella. Pehmeän kytkennän aiheuttamien häviöiden tarkka määrittely simulointimallista on parhaimmillaankin vain suuntaa-antava, mutta tulokset olivat mielestäni oikein positiivisia. LLC resonanssipiirin toimintaa tutkittiin vain resonanssitaajuudella kytkettäessä, jolloin sen jännitevahvistusominaisuuksien hyödyntäminen jää tarkastelun ulko-puolelle.
Resumo:
Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.