971 resultados para Predictive Mean Squared Efficiency
Resumo:
ABSTRACT The efficiency of nitrogen fertilizer in corn is usually low, negatively affecting plant nutrition, the economic return, and the environment. In this context, a variable rate of nitrogen, prescribed by crop sensors, has been proposed as an alternative to the uniform rate of nitrogen traditionally used by farmers. This study tested the hypothesis that variable rate of nitrogen, prescribed by optical sensor, increases the nitrogen use efficiency and grain yield as compared to uniform rate of nitrogen. The following treatments were evaluated: 0; 70; 140; and 210 kg ha-1 under uniform rate of nitrogen, and 140 kg ha -1 under variable rate of nitrogen. The nitrogen source was urea applied on the soil surface using a distributor equipped with the crop sensor. In this study, the grain yield ranged from 10.2 to 15.5 Mg ha-1, with linear response to nitrogen rates. The variable rate of nitrogen increased by 11.8 and 32.6% the nitrogen uptake and nitrogen use efficiency, respectively, compared to the uniform rate of nitrogen. However, no significant increase in grain yield was observed, indicating that the major benefit of the variable rate of nitrogen was reducing the risk of environmental impact of fertilizer.
Resumo:
ABSTRACTThis paper analyzes the changes in the total factor productivity index of a Spanish hotel chain in the period from 2007 to 2010 with the purpose of identifying efficiency patterns for the chain in a period of financial crisis. The data envelopment analysis (DEA) Malmquist productivity index was used to estimate productivity change in 38 hotels of the AC chain. Results reveal AC hotels' efficiency trends and, therefore, their competitiveness in the recession period; they also show the changes experienced in these hotels' total productivity and its components: technological and efficiency changes. Positive efficiency changes were due to positive technical efficiency rather than technological efficiency. The recession period certainly influenced the performance of AC Hotels, which focused on organizational changes rather than investing in technology.
Resumo:
The Wyner-Ziv video coding (WZVC) rate distortion performance is highly dependent on the quality of the side information, an estimation of the original frame, created at the decoder. This paper, characterizes the WZVC efficiency when motion compensated frame interpolation (MCFI) techniques are used to generate the side information, a difficult problem in WZVC especially because the decoder only has available some reference decoded frames. The proposed WZVC compression efficiency rate model relates the power spectral of the estimation error to the accuracy of the MCFI motion field. Then, some interesting conclusions may be derived related to the impact of the motion field smoothness and the correlation to the true motion trajectories on the compression performance.
Resumo:
This paper presents a predictive optimal matrix converter controller for a flywheel energy storage system used as Dynamic Voltage Restorer (DVR). The flywheel energy storage device is based on a steel seamless tube mounted as a vertical axis flywheel to store kinetic energy. The motor/generator is a Permanent Magnet Synchronous Machine driven by the AC-AC Matrix Converter. The matrix control method uses a discrete-time model of the converter system to predict the expected values of the input and output currents for all the 27 possible vectors generated by the matrix converter. An optimal controller minimizes control errors using a weighted cost functional. The flywheel and control process was tested as a DVR to mitigate voltage sags and swells. Simulation results show that the DVR is able to compensate the critical load voltage without delays, voltage undershoots or overshoots, overcoming the input/output coupling of matrix converters.
Resumo:
Environmental tobacco smoke (ETS) is recognized as an occupational hazard in the hospitality industry. Although Portuguese legislation banned smoking in most indoor public spaces, it is still allowed in some restaurants/bars, representing a potential risk to the workers’ health, particularly for chronic respiratory diseases. The aims of this work were to characterize biomarkers of early genetic effects and to disclose proteomic signatures associated to occupational exposure to ETS and with potential to predict respiratory diseases development. A detailed lifestyle survey and clinical evaluation (including spirometry) were performed in 81 workers from Lisbon restaurants. ETS exposure was assessed through the level of PM 2.5 in indoor air and the urinary level of cotinine. The plasma samples were immunodepleted and analysed by 2D-SDSPAGE followed by in-gel digestion and LC-MS/MS. DNA lesions and chromosome damage were analysed innlymphocytes and in exfoliated buccal cells from 19 cigarette smokers, 29 involuntary smokers, and 33 non-smokers not exposed to tobacco smoke. Also, the DNA repair capacity was evaluated using an ex vivo challenge comet assay with an alkylating agent (EMS). All workers were considered healthy and recorded normal lung function. Interestingly, following 2D-DIGE-MS (MALDI-TOF/TOF), 61 plasma proteins were found differentially expressed in ETS-exposed subjects, including 38 involved in metabolism, acute-phase respiratory inflammation, and immune or vascular functions. On the other hand, the involuntary smokers showed neither an increased level of DNA/chromosome damage on lymphocytes nor an increased number of micronuclei in buccal cells, when compared to non-exposed non-smokers. Noteworthy, lymphocytes challenge with EMS resulted in a significantly lower level of DNA breaks in ETS-exposed as compared to non-exposed workers (P<0.0001) suggestive of an adaptive response elicited by the previous exposure to low levels of ETS. Overall, changes in proteome may be promising early biomarkers of exposure to ETS. Likewise, alterations of the DNA repair competence observed upon ETS exposure deserves to be further understood. Work supported by Fundação Calouste Gulbenkian, ACSS and FCT/Polyannual Funding Program.
Resumo:
We have studied, in particular under normality of the implied random variables, the connections between different measures of risk such as the standard deviation, the W-ruin probability and the p-V@R. We discuss conditions granting the equivalence of these measures with respect to risk preference relations and the equivalence of dominance and efficiency of risk-reward criteria involving these measures. Then more specifically we applied these concepts to rigorously face the problem of finding the efficient set of de Finetti’s variable quota share proportional reinsurance.
Resumo:
OBJECTIVE: The aim of the study was to identify the variables that predict the revolving door phenomenon in psychiatric hospital at the moment of a second admission. METHODS: The sample consisted of 3,093 patients who have been followed during 5 to 24 years after their first hospital admission due to schizophrenia, and affective or psychotic disorders. Those who had had four or more admissions during the study period were considered as revolving door patients. Logistic regression analyses were used to assess the impact of gender, age, marital status, urban conditions, diagnosis, mean period of stay on the first admission, interval between the first and second admissions on the patterns of hospitalization. RESULTS: The variables with the highest predictive power for readmission were the interval between first and second admissions, and the length of stay in the first admission. CONCLUSIONS: These data may help public health planners in providing optimal care to a small group of patients with more effective utilization of the available services.
Resumo:
Enquadramento – A reforma dos Cuidados de Saúde Primários (CSP) é um facto irreversível. Uma “onda” de reforma percorre igualmente grande parte dos países ocidentais exigindo uma reflexão sobre o processo. Objetivo – Descrever a reforma em curso nos CSP e identificar os potenciais factores de sucesso e insucesso dos serviços públicos de cuidados de saúde primários. Metodologia – Análise crítica da literatura. Resultados e conclusões – A eficiência, eficácia e equidade de acesso aos cuidados de saúde são insuficientes. Mudanças organizacionais estão a ser operadas alterando as relações e a cooperação inter‑profissional e inter‑organizacional. É evidente a tensão que existe entre as partes envolvidas. Novas formas organizacionais estão a ser criadas para garantir a viabilidade das reformas e equilíbrio dos sistemas. O novo modelo organizacional, se pretender garantir a sustentabilidade e a viabilidade dos cuidados primários, deverá assentar num equilíbrio de gestão de recursos e numa estratégia de saúde para todos que não significa saúde para tudo. ABSTRACT: Background – Primary Health Care (PHC) reform is a fact in several countries and is happening also in Portugal demanding a reflection on the process. Aim – To describe the PHC reform and to identify the factors of success or potential failure in PHC public services. Methods – Critical appraisal of the literature. Results and Conclusions – The efficiency, efficacy and access to health care are insufficient. Organizational changes are taking place altering inter‑professional and inter‑organizational cooperation and relationship. Tension among the parts involved is evident. New organizational models are being created to secure the sustainability of the reforms and the systems. The new models should provide a balanced management of the available resources, in a strategy of health for all that doesn’t mean health for everything.
Resumo:
Since industrialization and the formation of larger urban centers in the nineteenth century, pollution of the environment was always present in daily life in various ways, namely in the form of light. Light pollution can cause various consequences, both for humans and for their ecosystem, producing effects on environmental, social, economic and scientific level. In Portugal, the lighting is responsible for 3% of total electricity consumption, energy costs are in some cases more than 50% towards the costs incurred by municipalities with energy, checking-in recent years a trend similar to that improvement of illumination levels in the region (about 4 to 5% per year). Proper use of lighting brings many benefits both to the citizen and environment, since greater energy efficiency can contribute to reducing CO2 emissions, energy costs, as well as to decrease the use of resources not-renewable and/or contamination of renewable resources, which can occurs in the process of obtaining electricity. The present study has a main goal to analyze the illuminance levels associated to the public lighting of the village of Vialonga, Vila Franca de Xira (Portugal), to verify if it is efficient. The aim is also to relate the efficiency of street lighting with the existence of light pollution.
Resumo:
Multilevel power converters have been introduced as the solution for high-power high-voltage switching applications where they have well-known advantages. Recently, full back-to-back connected multilevel neutral point diode clamped converters (NPC converter) have been used inhigh-voltage direct current (HVDC) transmission systems. Bipolar-connected back-to-back NPC converters have advantages in long-distance HVDCtransmission systems over the full back-to-back connection, but greater difficulty to balance the dc capacitor voltage divider on both sending and receiving end NPC converters. This study shows that power flow control and dc capacitor voltage balancing are feasible using fast optimum-predictive-based controllers in HVDC systems using bipolar back-to-back-connected five-level NPC multilevel converters. For both converter sides, the control strategytakes in account active and reactive power, which establishes ac grid currents in both ends, and guarantees the balancing of dc bus capacitor voltages inboth NPC converters. Additionally, the semiconductor switching frequency is minimised to reduce switching losses. The performance and robustness of the new fast predictive control strategy, and its capability to solve the DC capacitor voltage balancing problem of bipolar-connected back-to-back NPCconverters are evaluated.
Resumo:
Voltage source multilevel power converter structures are being considered for high power high voltage applications where they have well known advantages. Recently, full back-to-back connected multilevel neutral diode clamped converters (NPC) have been used in high voltage direct current (HVDC) transmission systems. Bipolar back-to-back connection of NPCs have advantages in long distance HVDC transmission systems, but highly increased difficulties to balance the dc capacitor voltage dividers on both sending and receiving end NPCs. This paper proposes a fast optimum-predictive controller to balance the dc capacitor voltages and to control the power flow in a long distance HVDCsystem using bipolar back-to-back connected NPCs. For both converter sides, the control strategy considers active and reactive power to establish ac grid currents on sending and receiving ends, while guaranteeing the balancing of both NPC dc bus capacitor voltages. Furthermore, the fast predictivecontroller minimizes the semiconductor switching frequency to reduce global switching losses. The performance and robustness of the new fast predictive control strategy and the associated dc capacitors voltage balancing are evaluated. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In this abstract is presented an energy management system included in a SCADA system existent in a intelligent home. The system control the home energy resources according to the players definitions (electricity consumption and comfort levels), the electricity prices variation in real time mode and the DR events proposed by the aggregators.
Resumo:
OBJECTIVE: To examine the effects of the length and timing of nighttime naps on performance and physiological functions, an experimental study was carried out under simulated night shift schedules. METHODS: Six students were recruited for this study that was composed of 5 experiments. Each experiment involved 3 consecutive days with one night shift (22:00-8:00) followed by daytime sleep and night sleep. The experiments had 5 conditions in which the length and timing of naps were manipulated: 0:00-1:00 (E60), 0:00-2:00 (E120), 4:00-5:00 (L60), 4:00-6:00 (L120), and no nap (No-nap). During the night shifts, participants underwent performance tests. A questionnaire on subjective fatigue and a critical flicker fusion frequency test were administered after the performance tests. Heart rate variability and rectal temperature were recorded continuously during the experiments. Polysomnography was also recorded during the nap. RESULTS: Sleep latency was shorter and sleep efficiency was higher in the nap in L60 and L120 than that in E60 and E120. Slow wave sleep in the naps in E120 and L120 was longer than that in E60 and L60. The mean reaction time in L60 became longer after the nap, and faster in E60 and E120. Earlier naps serve to counteract the decrement in performance and physiological functions during night shifts. Performance was somewhat improved by taking a 2-hour nap later in the shift, but deteriorated after a one-hour nap. CONCLUSIONS: Naps in the latter half of the night shift were superior to earlier naps in terms of sleep quality. However performance declined after a 1-hour nap taken later in the night shift due to sleep inertia. This study suggests that appropriate timing of a short nap must be carefully considered, such as a 60-min nap during the night shift.
Resumo:
OBJECTIVE: Pharmaceutical assistance is essential in health care and a right of citizens according to Brazilian law and drug policies. The study purpose was to evaluate aspects of pharmaceutical assistance in public primary health care. METHODS: A cross-sectional study using WHO drug indicators was carried out in Brasília in 2001. From a random sample of 15 out of 62 centers thirty exiting patients per center were interviewed. RESULTS: Only 18.7% of the patients fully understood the prescription, 56.3% could read it, 61.2% of the prescribed drugs were actually dispensed, and mean duration of pharmaceutical dispensing was 53.2 seconds. Each visit lasted on average 9.4 minutes. Of prescribed and non-dispensed drugs, 85.3% and 60.6% were on the local essential drug list (EDL) respectively. On average 83.2% of 40 essential drugs were in stock, and only two centers had a pharmacist in charge of the pharmacy. The mean number of drugs per prescription was 2.3, 85.3% of prescribed drugs were on the EDL, 73.2% were prescribed using the generic denomination, 26.4% included antibiotics and 7.5% were injectables. The most prescribed groups were: cardiovascular drugs (26.8%), anti-infective drugs (13.1%), analgesics (8.9%), anti-asthmatic drugs (5.8%), anti-diabetic drugs (5.3%), psychoactive drugs (3.7%), and combination drugs (2.7%). CONCLUSIONS: Essential drugs were only moderately available almost 30 years after the first Brazilian EDL was formulated. While physician use of essential drugs and generic names was fairly high, efficiency was impaired by the poor quality of pharmaceutical care, resulting in very low patient understanding and insufficient guarantee of supply, particularly for chronic diseases.