863 resultados para Predation risk. Ecology of stress. Non-lethal effects


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the increasing search for alternative sources of natural rubber (NR) whose properties are similar to Hevea brasiliesis, several sources have been studied in the past few years. Among them, Mangabeira (Hancornia speciosa Gomes), which is native to Amazon rainforest and other regions of Brazil, has a potential as another viable rubber source. As a continuation of a series of comparative studies between Hancornia and Hevea (clone RRIM 600) these two species by our research team, their thermal behavior was analyzed by thermogravimetry (TG) using Flynn-Wall-Ozawa's approach in order to obtain kinetic parameters (reaction order, pre-exponential factor and activation energy) of the decomposition process. Results indicated that the thermal behavior of NR from Hancornia was comparable to Hevea with some differences observed as follows: reaction order for Hancornia was higher than for Hevea at the beginning of degradation and very close for temperatures over 350 A degrees C; activation energy and pre-exponential factor had the same trend, i.e., increased with increasing degree of conversion remaining almost constant between 20 and 70% and then increasing for higher degrees, although Hevea was slightly more thermally stable than Hancornia. These major influences in the degradation process in the early stage are attributed to differences in non-rubber constituents present in these two species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oropharyngeal carriage of Pseudomonas aeruginosa is associated with increased risk of infection and may provide a source for spread of drug-resistant strains. In order to assess the incidence and risk factors of oropharyngeal carriage, we conducted a retrospective cohort study based on results of surveillance cultures (oropharyngeal swabs) from a medical-surgical intensive care unit, collected from March 2005 through May 2006. Variables investigated included demographic characteristics, comorbid conditions, invasive procedures, use of devices and use of antimicrobials. Thirty case patients with P. aeruginosa carriage were identified. Other 84 patients with surveillance cultures negative to P. aeruginosa were enrolled as control subjects. Case patients were more likely to have a solid malignancy (Odds Ratio [OR] = 12.04, 95% Confidence Interval [CI] = 1.93-75.09, p=0.008), Acquired Immunodeficiency Syndrome (AIDS, OR = 7.09, 95% CI=1.11-45.39, p = 0.04), central nervous system disease (OR = 4.51, 95% CI = 1.52-13.39, p = 0.007), or to have a central venous catheter placed (OR = 7.76, 95% CI = 1.68-35.79, p=0.009). The use of quinolones was a protective factor (OR = 0.13, 95% CI = 0.03-0.47, p = 0.002). The predominance of comorbidities as risk factors points out a group of patients to whom preventive measures should be directed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To evaluate the prevalence of and risk factors for Chlamydia trachomatis cervicitis in pregnant women seen at the Genital Tract Infection in Obstetrics Unit Care in Botucatu Medical School, São Paulo State University - UNESP.Materials and Methods. Between June 2006 and February 2008, 101 pregnant women were included in this study. During the gynecologic examination, cervical secretions were collected using cytobrush Plus GT (CooperSurgical Inc) to assess C. trachomatis using polymerase chain reaction. Vaginal flora were examined by Gram stain, and socio-demographic data were extracted from medical records.Results. of the 101 patients, 26 (25.7%) were positive for C. trachomatis. The median age of the infected group was 24 years (range = 13-40 y), and 48.5% of them had abnormal vaginal flora. The presence of chlamydial infection was associated with smoking (odds ratio [OR] = 2.67, 95% confidence interval [CI] = 1.01-7.19), residing in a city with fewer than 100,000 inhabitants (OR = 2.86, 95% CI = 1.03-7.94), presence of condyloma acuminatum (p = .03), and presence of discreet inflammation on Pap smear (p = .02).Conclusions. The prevalence of C. trachomatis is high in pregnant women seen at the Genital Infection Unit Care, UNESP, and is related to many risk factors. Therefore, its screening is extremely important in reducing obstetrical and neonatal complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Annatto (Bixa orellana L.) is a natural food colorant extensively used in many processed foods, especially dairy products. The lower cost of production and the low toxicity, make annatto a very attractive and convenient pigment in substitution to the many synthetic colorants. In the present study we investigate the carcinogenic and anticarcinogenic effects of dietary annatto in Wistar rat liver using the preneoplastic glutathione S-transferase (GST-P) foci and DNA damage biomarkers. Annatto, containing 5% bixin, was administered in the diet at concentrations of 20, 200, and 1000 ppm (0.07; 0.80 and 4.23 bixin/kg body wt/day, respectively), continuously during 2 weeks before, or 8 weeks after DEN treatment (200 mg/kg body wt, i.p.), to evaluate its effect on the liver-carcinogenesis medium-term bioassay. The comet assay was used to investigate the modifying potential of annatto on DEN (20 mg/kg body wt)-induced DNA damage. The results showed that annatto was neither genotoxic nor carcinogenic at the highest concentration tested (1000 ppm). No protective effects were also observed in both GST-P foci development and comet assays. In conclusion, in such experimental conditions, annatto shows no hepatocarcinogenic effect or modifying potential against DEN-induced DNA damage and preneoplastic foci in the rat liver. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of unilateral angular misfit of 100 Km on stress distribution of implant-supported single crowns with ceramic veneering and gold framework by three-dimensional finite element analysis. Two three-dimensional models representing a maxillary section of premolar region were constructed: group 1 (control)-crown completely adapted to the implant and group 2-crown with unilateral angular misfit of 100 Km. A vertical force of 100 N was applied on 2 centric points of the crown. The von Mises stress was used as an analysis criterion. The stress values and distribution in the main maps (204.4 MPa for group 1 and 205.0 MPa for group 2) and in the other structures (aesthetic veneering, framework, retention screw, implant, and bone tissue) were similar for both groups. The highest stress values were observed between the first and second threads of the retention screw. Considering the bone tissue, the highest stress values were exhibited in the peri-implant cortical bone. The unilateral angular misfit of 100 Km did not influence the stress distribution on the implant-supported prosthesis under static loading.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentuluos mandible supporting an overdenture over two unsplinted impants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be conclued that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the manibular overdenture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to present a literature review about photoelasticity, a laboratory method for evaluation of implants prosthesis behavior. Fixed or removable prostheses function as levers on supporting teeth, allowing forces to cause tooth movement if not carefully planned. Hence, during treatment planning, the dentist must be aware of the biomechanics involved and prevent movement of supporting teeth, decreasing lever-type forces generated by these prosthesis. Photoelastic analysis has great applicability in restorative dentistry as it allows prediction and minimization of biomechanical critical points through modifications in treatment planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)