920 resultados para Power-systems


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electric power systems are getting more complex and covering larger areas day by day. This fact has been contribuiting to the development of monitoring techniques that aim to help the analysis, control and planning of power systems. Supervisory Control and Data Acquisition (SCADA) systems, Wide Area Measurement Systems and disturbance record systems. Unlike SCADA and WAMS, disturbance record systems are mainly used for offilne analysis in occurrences where a fault resulted in tripping of and apparatus such as a transimission line, transformer, generator and so on. The device responsible for record the disturbances is called Digital Fault Recorder (DFR) and records, basically, electrical quantities as voltage and currents and also, records digital information from protection system devices. Generally, in power plants, all the DFRs data are centralized in the utility data centre and it results in an excess of data that difficults the task of analysis by the specialist engineers. This dissertation shows a new methodology for automated analysis of disturbances in power plants. A fuzzy reasoning system is proposed to deal with the data from the DFRs. The objective of the system is to help the engineer resposnible for the analysis of the DFRs’s information by means of a pre-classification of data. For that, the fuzzy system is responsible for generating unit operational state diagnosis and fault classification.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The focus of this work is the automatic analysis of disturbance records for electrical power generating units. The main proposition is a method based on wavelet transform applied to short-term disturbance records (waveform records). The goal of the method is to detect the time instants of recorded disturbances and extract meaningful information that characterize the faults. The result is a set of representative information of the monitored signals in power generators. This information can be further classified by an expert system (or other classification method) in order to classify the faults and other abnormal operating conditions. The large amount of data produced by digital fault recorders during faults justify the research of methods to assist the analysts in their task of analysing the disturbances. The literature review pointed out the state of the art and possible applications for oscillography records. The review of the COMTRADE standard and wavelet transform underlines the choice of the method for solving the problem. The conducted tests lead to the determination of the best mother wavelet for the segmentation process. The application of the proposed method to five case studies with real oscillographic records confirmed the accuracy and efficiency of the proposed scheme. With this research, the post-operation analysis of occurrences is improved and as a direct result is the reduction of the time that generators are offline.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents a low cost architecture for development of synchronized phasor measurement units (PMU). The device is intended to be connected in the low voltage grid, which allows the monitoring of transmission and distribution networks. Developments of this project include a complete PMU, with instrumentation module for use in low voltage network, GPS module to provide the sync signal and time stamp for the measures, processing unit with the acquisition system, phasor estimation and formatting data according to the standard and finally, communication module for data transmission. For the development and evaluation of the performance of this PMU, it was developed a set of applications in LabVIEW environment with specific features that let analyze the behavior of the measures and identify the sources of error of the PMU, as well as to apply all the tests proposed by the standard. The first application, useful for the development of instrumentation, consists of a function generator integrated with an oscilloscope, which allows the generation and acquisition of signals synchronously, in addition to the handling of samples. The second and main, is the test platform, with capabality of generating all tests provided by the synchronized phasor measurement standard IEEE C37.118.1, allowing store data or make the analysis of the measurements in real time. Finally, a third application was developed to evaluate the results of the tests and generate calibration curves to adjust the PMU. The results include all the tests proposed by synchrophasors standard and an additional test that evaluates the impact of noise. Moreover, through two prototypes connected to the electrical installation of consumers in same distribution circuit, it was obtained monitoring records that allowed the identification of loads in consumer and power quality analysis, beyond the event detection at the distribution and transmission levels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The insertion of distributed generation units in the electric power systems have contributed to the popularization of microgrid concepts. With the microgrids, several potential benefits can be achieved in regard to power quality and supply reliability. However, several technical challenges related to the control and operation of microgrids, which are associated with high insertion of generation systems based on static converters, must be overcame. Among the opportunities in the context of microgrids, there is the islanded operation of microgrids temporarily disconnected from the electric power systems and also the autonomous operation of geographically isolated microgrids. The frequency in large power systems is traditionally controlled by the generation units based on traditional synchronous generator. The insertion of distributed generation units based on static power converters may bring difficulties to the frequency control in microgrids, due to the reduction of the equivalent inertia of conventional synchronous generators present in islanded and isolated microgrids. In this context, it becomes necessary the proposition of new operational and control strategies for microgrids control, taking into account the presence of distributed generation units based on full-rated converter. This paper proposes an operational and control strategy for the islanded operation of a winddiesel microgrid with high insertion level of wind generation. The microgrid adopted in this study comprises of a wind energy conversion system with synchronous generator based on full rated converter, a diesel generator (DIG) and a dump load. Due to the high insertion level of wind generation, the wind unit operates in Vf mode and the diesel generator operates in PQ mode. The diesel generator and the dump load are used to regulate the DC-link voltage of the wind generation unit. The proposed control allows the islanded operation of the microgrid only with wind generation, wind-only mode (WO), and with wind-diesel generation, wind-diesel mode (WD). For the wind-only mode, with 100% of penetration level of wind generation, it is proposed a DC-link voltage control loop based on the use of a DC dump load. For the winddiesel mode, it is proposed a DC-link voltage control loop added to the diesel generator, which is connected to the AC side of the microgrid, in coordinated action with the dump load. The proposed operational and control strategy does not require the use of batteries and aims to maximize the energy production from wind generation, ensuring the uninterrupted operation of the microgrid. The results have showed that the operational and control strategy allowed the stable operation of the islanded microgrid and that the DC-link voltage control loop added to the diesel generator and the dump load proved to be effective during the typical variations of wind speed and load.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The optical access engine integrated with the diagnostic and optical measurement techniques is a great platform for engine research because it provides clear visual access to the combustion chamber inside the engines. An optical access engine customized based on a 4-cylinder spark ignited direct injection (SIDI) production engine is located in the Advanced Power Systems Laboratories (APS LABS) at Michigan Technological University. This optical access engine inside the test cell has been set up for different engine research. In this report, two SAE papers in engine research utilizing the optical access engine are reviewed to gain basic understanding of the methodology. Though the optical engine in APS LABS is a little bit different from the engines used in the literature, the methodology in the papers provides guidelines for engine research through optical access engines. In addition, the optical access engine instrumentation including the test cell setup and the optical engine setup is described in detail in the report providing a solid record for later troubleshooting and reference. Finally, the motoring tests, firing tests and optical imaging experiment on the optical engine have been performed to validate the instrumentation. This report only describes so far the instrumentation of the optical engine in the APS LABS by April 2015.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Future power grids are envisioned to be serviced by heterogeneous arrangements of renewable energy sources. Due to their stochastic nature, energy storage distribution and management are pivotal in realizing microgrids serviced heavily by renewable energy assets. Identifying the required response characteristics to meet the operational requirements of a power grid are of great importance and must be illuminated in order to discern optimal hardware topologies. Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) presents the tools to identify such characteristics. By using energy storage as actuation within the closed loop controller, the response requirements may be identified while providing a decoupled controller solution. A DC microgrid servicing a fixed RC load through source and bus level storage managed by HSSPFC was realized in hardware. A procedure was developed to calibrate the DC microgrid architecture of this work to the reduced order model used by the HSSPFC law. Storage requirements were examined through simulation and experimental testing. Bandwidth contributions between feed forward and PI components of the HSSPFC law are illuminated and suggest the need for well-known system losses to prevent the need for additional overhead in storage allocations. The following work outlines the steps taken in realizing a DC microgrid and presents design considerations for system calibration and storage requirements per the closed loop controls for future DC microgrids.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The recent development of the concept of microgrid (μGrid), associated to the emergent interest in microgeneration (μGen), has raised a number of challenges regarding the evaluation of the technical, economical and regulatory impacts of a high penetration of this kind of solutions in the power systems. In this paper, the topic of security of supply is addressed, aiming at evaluating the influence of μGen and μGrids in the medium- and long-term availability of generation to serve the forecasted load. A Monte-Carlo based methodology is used to evaluate this influence and to assess the capacity credit of those entities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the scope of the discussions about microgeneration (and microgrids), the avoided electrical losses are often pointed out as an important value to be credited to those entities. Therefore, methods to assess the impact of microgeneration on losses must be developed in order to support the definition of a suitable regulatory framework for the economic integration of microgeneration on distribution networks. This paper presents an analytical method to quantify the value of avoided losses that microgeneration may produce on LV networks. Intervals of expected avoided losses are used to account for the variation of avoided losses due to the number, size and location of microgenerators, as well as for the kind of load distribution on LV networks.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The emergence of microgeneration has recently lead to the concept of microgrid, a network of LV consumers and producers able to export electric energy in some circumstances and also to work in an isolated way in emergency situations. Research on the organization of microgrids, control devices, functionalities and other technical aspects is presently being carried out, in order to establish a consistent technical framework to support the concept. The successful development of the microgrid concept implies the definition of a suitable regulation for its integration on distribution systems. In order to define such a regulation, the identification of costs and benefits that microgrids may bring is a crucial task. Actually, this is the basis for a discussion about the way global costs could be divided among the different agents that benefit from the development of microgrids. Among other aspects, the effect of microgrids on the reliability of the distribution network has been pointed out as an important advantage, due to the ability of isolated operation in emergency situations. This paper identifies the situations where the existence of a microgrid may reduce the interruption rate and duration and thus improve the reliability indices of the distribution network. The relevant expressions necessary to quantify the reliability are presented. An illustrative example is included, where the global influence of the microgrid in the reliability is commented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis studies the state-of-the-art of phasor measurement units (PMUs) as well as their metrological requirements stated in the IEEE C37.118.1 and C37.118.2 Standards for guaranteeing correct measurement performances. Communication systems among PMUs and their possible applicability in the field of power quality (PQ) assessment are also investigated. This preliminary study is followed by an analysis of the working principle of real-time (RT) simulators and the importance of hardware-in-the-loop (HIL) implementation, examining the possible case studies specific for PMUs, including compliance tests which are one of the most important parts. The core of the thesis is focused on the implementation of a PMU model in the IEEE 5-bus network in Simulink and in the validation of the results using OPAL RT-4510 as a real-time simulator. An initial check allows one to get an idea about the goodness of the results in Simulink, comparing the PMU data with respect to the load-flow steady-state information. In this part, accuracy indices are also calculated for both voltage and current synchrophasors. The following part consists in the implementation of the same code in OPAL-RT 4510 simulator, after which an initial analysis is carried out in a qualitative way in order to get a sense of the goodness of the outcomes. Finally, the confirmation of the results is based on an examination of the attained voltage and current synchrophasors and accuracy indices coming from Simulink models and from OPAL system, using a Matlab script. This work also proposes suggestions for an upcoming operation of PMUs in a more complex system as the Digital Twin (DT) in order to improve the performances of the already-existing protection devices of the distribution system operator (DSO) for a future enhancement of power systems reliability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Energy transition is the response of humankind to the concerning effects of fossil fuels depletion, climate change and energy insecurity, and calls for a deep penetration of renewable energy sources (RESs) in power systems and industrial processes. Despite the high potentials, low impacts and long-term availability, RESs present some limits which need to be overcome, such as the strong variability and difficult predictability, which result in scarce reliability and difficult applicability in steady-state processes. Some technological solutions relate to energy storage systems, equipment electrification and hybrid systems deployment, thus accomplishing distributed generation even in remote sites as offshore. However, all of these actions cannot disregard sustainability, which represents a founding principle for any project, bringing together economics, reliability and environmental protection. To entail sustainability in RESs-based innovative projects, previous knowledge and tools are often not tailored or miss the novel objectives. This research proposes three methodological approaches, bridging the gaps. The first contribute adapts literature-based indicators of inherent safety and energy efficiency to capture the specificities of novel process plants and hybrid systems. Minor case studies dealing with novel P2X processes exemplify the application of these novel indicators. The second method guides the conceptual design of hybrid systems for the valorisation of a RES in a site, by considering the sustainability performances of alternative design options. Its application is demonstrated through the comparison of two offshore sites where wave energy can be valorised. Finally, “OHRES”, a comprehensive tool for the sustainable optimisation of hybrid renewable energy systems is proposed. “OHRES” hinges on the exploitation of multiple RESs, by converting ex-post sustainability indicators into discrimination markers screening a large number of possible system configurations, according to the location features. Five case studies demonstrate “OHRES” versatility in the sustainable valorisation of multiple RESs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The power transformer is a piece of electrical equipment that needs continuous monitoring and fast protection since it is very expensive and an essential element for a power system to perform effectively. The most common protection technique used is the percentage differential logic, which provides discrimination between an internal fault and different operating conditions. Unfortunately, there are some operating conditions of power transformers that can affect the protection behavior and the power system stability. This paper proposes the development of a new algorithm to improve the differential protection performance by using fuzzy logic and Clarke`s transform. An electrical power system was modeled using Alternative Transients Program (ATP) software to obtain the operational conditions and fault situations needed to test the algorithm developed. The results were compared to a commercial relay for validation, showing the advantages of the new method.