970 resultados para Periodic arrays


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel manufacturing process for fabricating microneedle arrays (MN) has been designed and evaluated. The prototype is able to successfully produce 14 × 14 MN arrays and is easily capable of scale-up, enabling the transition from laboratory to industry and subsequent commercialisation. The method requires the custom design of metal MN master templates to produce silicone MN moulds using an injection moulding process. The MN arrays produced using this novel method was compared with centrifugation, the traditional method of producing aqueous hydrogel-forming MN arrays. The results proved that there was negligible difference between either methods, with each producing MN arrays with comparable quality. Both types of MN arrays can be successfully inserted in a skin simulant. In both cases the insertion depth was approximately 60% of the needle length and the height reduction after insertion was in both cases approximately 3%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The introduction of the Universal Periodic Review (UPR) mechanism as an innovative component of the new Human Rights Council in 2006 has suffered little academic scrutiny. This is partly because it holds as its objective an improvement in human rights situations on the ground, a goal that is difficult to test amongst so many possible causal factors attributable to law reform and policy change, and partly due to the fact that the mechanism has only completed one full cycle of review. This article seeks to remedy this absence of analysis by examining the experience of the United Kingdom during its first review. In doing so, the article first considers the conception of the UPR, before progressing to examine the procedure and recommendations made to the UK by its peers. Finally, the article considers the five year review of the UPR which occurred as a subset of the Human Rights Council Review in 2011 and the resulting changes to the process modalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of biological tissues in the in vitro assessments of dissolving (?) microneedle (MN) array mechanical strength and subsequent drug release profiles presents some fundamental difficulties, in part due to inherent variability of the biological tissues employed. As a result, these biological materials are not appropriate for routine used in industrial formulation development or quality control (QC) tests. In the present work a facile system using Parafilm M® (PF) to test drug permeation performance using dissolving MN arrays is proposed. Dissolving MN arrays containing 196 needles (600 μm needle height) were inserted into a single layer of PF and a hermetic “pouch” was created including the array inside. The resulting system was placed in a dissolution bath and the release of model molecules was evaluated. Different MN formulations were tested using this novel setup, releasing between 40 and 180 µg of their cargos after 6 hours. The proposed system is a more realistic approach for MN testing than the typical performance test described in the literature for conventional transdermal patches. Additionally, the use of PF membrane was tested either in the hermetic “pouch” and using Franz Cell methodology yielding comparable release curves. Microscopy was used in order to ascertain the insertion of the different MN arrays in the PF layer. The proposed system appears to be a good alternative to the use of Franz cells in order to compare different MN formulations. Given the increasing industrial interest in MN technology, the proposed system has potential as a standardised drug/active agent release test for quality control purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Controlled periodic illumination is a hypothesis postulated in the early 1990s for enhancing the efficiency of semiconductor photocatalytic reactions. This technique has been proposed to improve photocatalytic efficiency by the nature of photon introduction alone. Before its application in semiconductor photocatalysis, controlled periodic illumination had been investigated in other fields including photosynthesis. This paper presents a detailed review of the state of the art research undertaken on the application of controlled periodic illumination in semiconductor photocatalysis. The review briefly introduces semiconductor photocatalysis, and then presents a detailed explanation of this technique, its importance to photocatalytic efficiency, an overview of previous results of its application in significant studies and present knowledge. Results from previous as well as some of the most recent studies indicate potential applications of controlled periodic illumination in areas other than just the improvement of the efficiency of the photocatalytic process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new type of focal-palne array made of a nanoscale metal screen mimics the function of a lens, focuses light (and plasmons) into subwavelength hot spots, and achieves high-resolution imaging of complex sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe, for the first time the use of hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of drug substances and glucose from skin in vitro and in vivo. MN prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) (11.1% w/w) and poly(ethyleneglycol) 10,000 daltons (5.6% w/w) and crosslinked by esterification swelled upon skin insertion by uptake of fluid. Post-removal, theophylline and caffeine were extracted from MN and determined using HPLC, with glucose quantified using a proprietary kit. In vitro studies using excised neonatal porcine skin bathed on the underside by physiologically-relevant analyte concentrations showed rapid (5 min) analyte uptake. For example, mean concentrations of 0.16 μg/mL and 0.85 μg/mL, respectively, were detected for the lowest (5 μg/mL) and highest (35 μg/mL) Franz cell concentrations of theophylline after 5 min insertion. A mean concentration of 0.10 μg/mL was obtained by extraction of MN inserted for 5 min into skin bathed with 5 μg/mL caffeine, while the mean concentration obtained by extraction of MN inserted into skin bathed with 15 μg/mL caffeine was 0.33 μg/mL. The mean detected glucose concentration after 5 min insertion into skin bathed with 4 mmol/L was 19.46 nmol/L. The highest theophylline concentration detected following extraction from a hydrogel-forming MN inserted for 1 h into the skin of a rat dosed orally with 10 mg/kg was of 0.363 μg/mL, whilst a maximum concentration of 0.063 μg/mL was detected following extraction from a MN inserted for 1 h into the skin of a rat dosed with 5 mg/kg theophylline. In human volunteers, the highest mean concentration of caffeine detected using MN was 91.31 μg/mL over the period from 1 to 2 h post-consumption of 100 mg Proplus® tablets. The highest mean blood glucose level was 7.89 nmol/L detected 1 h following ingestion of 75 g of glucose, while the highest mean glucose concentration extracted from MN was 4.29 nmol/L, detected after 3 hours skin insertion in human volunteers. Whilst not directly correlated, concentrations extracted from MN were clearly indicative of trends in blood in both rats and human volunteers. This work strongly illustrates the potential of hydrogel-forming MN in minimally-invasive patient monitoring and diagnosis. Further studies are now ongoing to reduce clinical insertion times and develop mathematical algorithms enabling determination of blood levels directly from MN measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a multi-pair two-way amplify-and-forward relaying system with a massive antenna array at the relay and estimated channel state information, assuming maximum-ratio combining/transmission processing. Closed-form approximations of the sum spectral effi- ciency are developed and simple analytical power scaling laws are presented, which reveal a fundamental trade-off between the transmit powers of each user/the relay and of each pilot symbol. Finally, the optimal power allocation problem is studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe, for the first time, stimuli-responsive hydrogel-forming microneedle (MN) arrays that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of light. MN arrays were prepared using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) by micromolding. The obtained MN arrays showed good mechanical properties. The system was loaded with up to 5% (w/w) ibuprofen included in a light-responsive 3,5-dimethoxybenzoin conjugate. Raman spectroscopy confirmed the presence of the conjugate inside the polymeric MN matrix. In vitro, this system was able to deliver up to three doses of 50 mg of ibuprofen upon application of an optical trigger over a prolonged period of time (up to 160 hours). This makes the system appealing as a controlled release device for prolonged periods of time. We believe that this technology has potential for use in ?on-demand? delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe, for the first time, hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of lithium in vitro and in vivo. MN arrays, prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) and crosslinked by poly(ethyleneglycol), imbibed interstitial fluid (ISF) upon skin insertion. Such MN were always removed intact. In vitro, mean detected lithium concentrations showed no significant difference following 30 min MN application to excised neonatal porcine skin for lithium citrate concentrations of 0.9 and 2 mmol/l. However, after 1 h application, the mean lithium concentrations extracted were significantly different, being appropriately concentration-dependent. In vivo, rats were orally dosed with lithium citrate equivalent to 15 mg/kg and 30 mg/kg lithium carbonate, respectively. MN arrays were applied 1 h after dosing and removed 1 h later. The two groups, having received different doses, showed no significant difference between lithium concentrations in serum or MN. However, the higher dosed rats demonstrated a lithium concentration extracted from MN arrays equivalent to a mean increase of 22.5 % compared to rats which received the lower dose. Hydrogel-forming MN clearly have potential as a minimally-invasive tool for lithium monitoring in out-patient settings. We will now focus on correlation of serum and MN lithium concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transdermal drug delivery offers a number of advantages for the patient, due not only its non-invasive and convenient nature, but also factors such as avoidance of first pass metabolism and prevention of gastrointestinal degradation. It has been demonstrated that microneedle arrays can increase the number of compounds amenable to transdermal delivery by penetrating the skin's protective barrier, the stratum corneum, and creating a pathway for drug permeation to the dermal tissue below. Microneedles have been extensively investigated in recent decades for drug and vaccine delivery as well as minimally invasive patient monitoring/diagnosis. This review focuses on a range of critically important aspects of microneedle technology, namely their material composition, manufacturing techniques, methods of evaluation and commercial translation to the clinic for patient benefit and economic return. Microneedle research and development is finally now at the stage where commercialisation is a realistic possibility. However, progress is still required in the areas of scaled-up manufacture and regulatory approval.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wave energy converters, by their nature, extract large amounts of energy
from incident waves. If the industry is to progress such that wave energy
becomes a significant provider of power in the future, large wave farms will
be required. Presently, consenting for these sites is a long and problematic
process, mainly due to a lack of knowledge of the potential environmental
impacts. Accurate numerical modelling of the effect of wave energy extraction
on the wave field and subsequent evaluation of changes to coastal
processes is therefore required. Modelling the wave field impact is also
necessary to allow optimum wave farm configurations to be determined.
This thesis addresses the need for more accurate representation of wave
energy converters in numerical models so that the effect on the wave field,
and subsequently the coastal processes, may be evaluated. Using a hybrid
of physical and numerical modelling (MIKE21 BW and SW models) the
effect of energy extraction and operation of a WEC array on the local wave
climate has been determined.
The main outcomes of the thesis are: an improved wave basin facility, in
terms of wave climate homogeneity, reducing the standard deviation of wave
amplitude by up to 50%; experimental measurement of the wave field around
WEC arrays, showing that radiated waves account for a significant proportion
of the wave disturbance; a new representation method of WECs for use
with standard numerical modelling tools, validated against experimental
results.
The methodology and procedures developed here allow subsequent evaluation
of changes to coastal processes and sediment transport due to WEC
arrays.