797 resultados para Performance Measurement System, PMS, review PMS, KPIs


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The wet bulk density is one of the most important parameters of the physical and geological properties of marine sediments. The density is connected directly with sedimentation history and a few sedirnent properties. Knowledge of the fine scale density-depth structure is the base for many model calculations, for both sedimentological and palaeoclimatic research. A density measurement system was designed and built at the Alfred Wegener Institute in Bremerhaven for measuring the wet buk density of sediment cores with high resolution in a non-destructive way. The density is deterrnined by measuring the absorption of Gamma-rays in the sediment. This principle has been used since the 50's in materials research and in the geosciences. In the present case, Cs137 is used as the radioactive source and the intensity is measured by a detector system (scintillator and photomultiplier). Density values are obtainable in both longitudinal core sections and planar cross-sections (the latter are a function of the axial rotation angle). Special studies on inhomogenity can be applied with core rotation. Detection of ice rafted debris (IRD) is made possible with this option. The processes that run the density measurement system are computer controlled. Besides the absorption measurement the core diameter at every measurement point is determined with a potentiometric system. The data values taken are stored on a personal computer. Before starting routine measurements on the sediment cores, a few experiments conceming the statistical aspects of the gamma-ray signal and its accuracy were carried out. These experiments led to such things as the optimum operational parameters. A high spatial resolution in the mm-range is possible with the 4mm-thin gamma-ray measurements. Within five seconds the wet bulk density can be deterrnined with an absolute accuracy of 1%. A comparison between data measured with the new system and conventional measurements on core samples after core splitting shows an agreement within +I- 5% for most of the values. For this thesis, density determinations were carried out on ten sediment cores. A few sediment characteristics are obtainable from using just the standard measurement results without core rotation. In addition to differentes and steps in the absolute density range, variations in the "frequency" of the density-depth structure can be detected due to the close spatial measurement interval and high resolution. Examples from measurements with small (9°) and great (90°) angle increments show that abrupt and smooth transitional changes of sedirnent layers as well as ice rafted debris of several dimensions can be detected and distiflguished clearly. After the presentation of the wet bulk density results, a comparison with data from other investigations was made. Measurements of the electrical resistivity correlated very well with the density data because both parameters are closely related to the porosity of the sedirnent. Additionally, results from measurements of the magnetic susceptibility and from ultra-sonic wave velocity investigations were considered for a integrative interpretation. The correlation of these both parameters and wet bulk density data is strongly dependent on the local (environmental) conditions. Finally, the densities were compared with recordings from sediment-echographic soundings and an X-ray computer tomography analysis. The individual results of all investigations were then finally combined into an accurate picture of the core. Problems of ambiguity, which exist when just one Parameter is determined alone, can be reduced more or less according to the number of parameters and sedimentary characteristics measured. The important role of the density data among other parameters of such an integrated interpretation is evident. Evidence of this role include the high resolution of the measurement, the excellent accuracy and the key position within methods and parameters concerning marine sediments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last 20 years directed shark and ray fishery has increased alarmingly everywhere in the world. For most species though, no data on growth rate, mortality, fecundity and other life history aspects exist as of now and management of the fishery is therefore insufficient. Also there still exist methodological difficulties in the age determination of elasmobranchs fishes, a fact which complicates the investigation of growth parameters. This study tried to identify the best ageing methods and estimate growth parameters for ten skate species of the genus Bathyraja, all occurring in the southwest Atlantic in depths of 50m and more. 720 samples were collected on board of argentine research vessels in between 2003 and 2005. Crystal violet and a new staining method using potassium permanganate, both applied on sagittal sections of vertebral centra, proved to be most effective in enhancing the banding pattern in most of the species. Thorns were also tested and readings were consistent with the ones made on vertebral sections. Growth parameters could be derived for six species and for the other four estimates could be made. Growth rate as well as infinite length varied between species, with those attaining bigger sizes having lower growth rates. No latitudinal differences in growth rate could be detected but a comparison with samples from other studies showed that total lengths were always reported to be higher around the Malvinas Islands.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

streets in local residential areas in large cities, real traffic tests for pollutant emissions and fuel consumption have been carried out in Madrid city centre. Emission concentration and car activity were simultaneously measured by a Portable Emissions Measurement System. Real life tests carried out at different times and on different days were performed with a turbo-diesel engine light vehicle equipped with an oxidizer catalyst and using different driving styles with a previously trained driver. The results show that by reducing the speed limit from 50 km h-1 to 30 km h-1, using a normal driving style, the time taken for a given trip does not increase, but fuel consumption and NOx, CO and PM emissions are clearly reduced. Therefore, the main conclusion of this work is that reducing the speed limit in some narrow streets in residential and commercial areas or in a city not only increases pedestrian safety, but also contributes to reducing the environmental impact of motor vehicles and reducing fuel consumption. In addition, there is also a reduction in the greenhouse gas emissions resulting from the combustion of the fuel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este proyecto fin de carrera tiene como finalidad el diseño e implementación de un sistema multicanal de medida de temperaturas con termopares con procesado digital. Se ha realizado un prototipo de cuatro canales con conexión de termopar, que es el tipo de sensor utilizado para realizar dichas medidas. La tensión generada por el termopar es procesada mediante un conversor de termopar a digital con salida en interfaz modo serie o SPI (Serial Peripheral Interface). El control de dicha comunicación se realiza por medio de un Array de Puertas Lógicas Programables o FPGA (Field Programmable Gate Array), en concreto se ha utilizado una plataforma de desarrollo modelo Virtex-5 de la empresa Xilinx. Esta tarjeta se ha programado también para el procesado software y la posterior comunicación serie con el PC, el cual consta de una interfaz de usuario donde se muestran los resultados de las medidas en tiempo real. El proyecto ha sido desarrollado en colaboración con una empresa privada dedicada principalmente al diseño electrónico. La finalidad de este prototipo es el estudio de una actualización del bloque de medida para el control de las curvas de temperatura de un equipo de reparación aeronáutica. En esta memoria se describe el proceso realizado para el desarrollo del prototipo, incluye la presentación de los estudios realizados y la información necesaria para llevar a cabo el diseño, la fabricación y la programación de los diferentes bloques que componen el sistema. ABSTRACT. The aim of this project is to implement a multichannel temperature measurement system with digital processing, using thermocouples. A four-channel prototype with thermocouple connection has been built. The thermocouple voltage is converted to digital line using a Thermocouple-to-Digital Converter with a Serial Perpheral Interface (SPI) output. The master which controls this communication is embedded in a Field Programmable Gate Array (FPGA), specifically the Xilinx Virtex-5 model. This FPGA also has the code for software temperature processing and the prototype to PC serial communication embedded. The PC user interface displays the measurement results in real time. This project has been developed at a private electronics design company. The company wants to study an update to change the analogue temperature controller equipment to a digital one. So this prototype studies a digital version of the temperature measurement block. The processes accomplished for the prototype development are detailed in the next pages of this document. It includes the studies and information needed to develop the design, manufacturing process and programming of the blocks which integrate with the global system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents ASYTRAIN, a new tool to teach and learn antennas, based on the use of a modular building kit and a low cost portable antenna measurement system that lets the students design and build different types of antennas and observe their characteristics while learning the insights of the subjects. This tool has a methodology guide for try-and-test project development and, makes the students be active antenna engineers instead of passive learners. This experimental learning method arises their motivation during the antenna courses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Las sondas eléctricas se emplean habitualmente en la diagnosis de plasmas. La presente tesis aborda la operación de las sondas colectoras y emisoras de Langmuir en plasmas fríos de baja densidad. El estudio se ha centrado en la determinación del potencial de plasma, Vsp, mediante el potencial flotante de una sonda emisora. Esta técnica consiste en la medida del potencial de la sonda correspondiente a la condición de corriente neta igual a cero, el cual se denomina potencial flotante, VF. Este potencial se desplaza hacia el potencial del plasma según aumenta la emisión termoiónica de la sonda, hasta que se satura cerca de Vsp. Los experimentos llevados a cabo en la pluma de plasma de un motor iónico y en un plasma de descarga de glow muestran que la corriente de electrones termoiónicos es mayor que la corriente de electrones recogidos para una sonda polarizada por debajo del potencial del plasma, resultado inconsistente con la teoría tradicionalmente aceptada. Para investigar estos resultados se ha introducido el parámetro R, definido como el cociente entre la corriente de electrones emitidos y recogidos por la sonda. Este parámetro, que está relacionado con la diferencia de potencial VF - Vsp, también es útil para la descripción de los modos de operación de la sonda emisora (débil, fuerte y más allá del fuerte). Los resultados experimentales evidencian que, al contrario de lo que indica la teoría, R es mayor que la unidad. Esta discrepancia se puede solucionar introduciendo una población efectiva de electrones. Con dicha población, el nuevo modelo para la corriente total de la sonda reproduce los datos experimentales. El origen de este grupo electrónico es todavía una cuestión abierta, pero podría estar originada por una nueva estructura de potencial cerca de la sonda cuando ésta trabaja en el régimen de emisión fuerte. Para explicar dicha estructura de potencial, se propone un modelo unidimensional compuesto por un mínimo de potencial cerca de la superficie de la sonda. El análisis numérico indica que este pozo de potencial aparece para muy altas temperaturas de la sonda, reduciendo la cantidad de electrones emitidos que alcanzan el plasma y evitando así cualquier posible perturbación de éste. Los aspectos experimentales involucrados en el método del potencial flotante también se han estudiado, incluyendo cuestiones como las diferentes técnicas de obtención del VF, el cociente señal-ruido, el acoplamiento de la señal de los equipos utilizados para la obtención de las curvas I-V o la evidencia experimental de los diferentes modos de operación de la sonda. Estas evidencias empíricas se encuentran en todos los aspectos de operación de la sonda: la recolección de electrones, el potencial flotante, la precisión en las curvas I-V y la emisión electrónica. Ésta última también se estudia en la tesis, debido a que un fenómeno de super emisión tiene lugar en el régimen de emisión fuerte. En este modo de operación, las medidas experimentales indican que las corrientes termoiónicas de electrones son mayores que aquéllas predichas por la ecuación de Richardson-Dushman clásica. Por último, la diagnosis de plasmas usando sondas eléctrica bajo presencia de granos de polvo (plasmas granulares) en plasmas fríos de baja densidad también se ha estudiado, mediante la aplicación numérica de la técnica del potencial flotante de la sonda emisora en un plasma no convencional. Los resultados apuntan a que el potencial flotante de una sonda emisora se vería afectado por altas densidades de polvo o grandes partículas. ABSTRACT Electric probes are widely employed for plasma diagnostics. This dissertation concerns the operation of collecting and emissive Langmuir probes in low density cold plasmas. The study is focused on the determination of the plasma potential, Vsp, by means of the floating potential of emissive probes. This technique consists of the measurement of the probe potential, corresponding to the zero net probe current, which is the so-called floating potential, VF . This potential displaces towards the plasma potential as the thermionic electron emission increases, until it saturates near Vsp. Experiments carried out in the plasma plume of an ion thruster and in a glow discharge plasma show the thermionic electron current of the emissive Langmuir probe is higher than the collected electron current, for a probe with a bias potential below Vsp, which is inconsistent with the traditional accepted theory. To investigate these results, a parameter R is introduced as the ratio between the emitted and the collected electron current. This parameter, which is related to the difference VF - Vsp, is also useful for the description of the operation modes of the emissive Langmuir probe (weak, strong and beyond strong). The experimental results give an inconsistency of R > 1, which is solved by a modification of the theory for emissive probes, with the introduction of an effective electron population. With this new electron group, the new model for the total probe current agrees with the experimental data. The origin of this electron group remains an open question, but it might be originated by a new potential structure near the emissive probe when it operates in the strong emission regime. A simple one-dimension model composed by a minimum of potential near the probe surface is discussed for strongly emitting emissive probes. The results indicate that this complex potential structure appears for very high probe temperatures and the potential well might reduce the emitted electrons population reaching the plasma bulk. The experimental issues involved in the floating potential method are also studied, as the different obtaining techniques of VF, the signal-to-noise ratio, the signal coupling of the I-V curve measurement system or the experimental evidence of the probe operation modes. These empirical proofs concern all the probe operation aspects: the electron collection, the floating potential, the I-V curve accuracy as well as the electron emission. This last issue is also investigated in this dissertation, because a super emission takes place in the strong emission regime. In this operation mode, the experimental results indicate that the thermionic electron currents might be higher than those predicted by the classical Richardson-Dushman equation. Finally, plasma diagnosis using electric probes in the presence of dust grains (dusty plasmas) in low density cold plasmas is also addressed. The application of the floating potential technique of the emissive probe in a non-conventional complex plasma is numerically investigated, whose results point out the floating potential of the emissive probe might be shifted for high dust density or large dust particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El proyecto fin de carrera “Sistema Portátil de Medida de Dispositivos Sometidos a Ensayos en Campo” es un proyecto acometido para el desarrollo y evaluación de un sistema de medición portátil y confiable, que permita la realización de mediciones de curvas I-V en campo, en condiciones reales de funcionamiento. Dado que la finalidad de este proyecto fin de carrera es la obtención de un sistema para la realización de mediciones en campo, en la implementación del proyecto se tendrán como requisitos principales de diseño el tamaño, la fuente de alimentación, el peso del sistema, además de la fiabilidad y una relativa precisión en la realización de mediciones. Durante la realización de este proyecto y dados los requerimientos anteriores de portabilidad y fiabilidad, se ha buscado ofrecer una solución de compromiso diseñando un equipamiento que sea realizable, que cumpla con los objetivos anteriores con un coste que no sea elevado y con la característica de que disponga de una facilidad de manejo que permita a cualquier usuario la utilización del mismo. El sistema final diseñado está basado en el dispositivo de adquisición de datos MyDAQ de National Instruments que permite la realización de múltiples tipos de mediciones. En base a este dispositivo de adquisición de datos, se ha diseñado un sistema de medición con una arquitectura que se implementa a través de un ordenador portátil, con un software de medición instalado que recopila e interpreta los datos, y que alimenta y controla al dispositivo a través del puerto USB. El sistema también implementa una carga variable que permite la medición de la curva I-V en iluminación de células o mini-paneles fotovoltaicos. Este diseño permite que para la realización de las mediciones de las curvas I-V en iluminación en campo sólo se requiera conectar el dispositivo de adquisición a un PC portátil con batería y a la carga variable. Aunque este diseño es específico para la medición de células solares se ha implementado de forma que pueda extrapolarse fácilmente a otro tipo de medición de tensión y corriente. Para la comprobación de la precisión del sistema portátil de medidas, durante el proyecto se ha procedido a la comparación de los resultados obtenidos del sistema diseñado con un equipo de caracterización en laboratorio. Dicho sistema de alta exactitud permite cuantificar la degradación real de la célula y establecer una comparación de mediciones con el sistema portátil de medida, ofreciendo resultados satisfactorios en todas las mediciones realizadas y permitiendo concluir la evaluación del sistema portátil como apto para las mediciones de dispositivos en campo. El proceso de evaluación del equipamiento diseñado consistiría en la medida de la curva I-V en laboratorio de un dispositivo fotovoltaico con instrumentación de alta precisión y condiciones controladas de luz y temperatura de un dispositivo, célula o mini-panel. Tras la medida inicial las células se instalarían en campo y se realizaría una caracterización periódica de los dispositivos mediante el sistema portátil de medida, que permitiría evidenciar si en la curva I-V bajo iluminación existe degradación, y en qué zona de la curva. Al finalizar el ensayo o en periodos intermedios se desmontarían los dispositivos para volver a medir la curva I-V con exactitud en laboratorio. Por tanto el sistema portátil de medida, debe permitir evaluar la evolución de la curva I-V en condiciones ambientales similares a obtenidas en medidas anteriores, y a partir de la misma determinar el modo de degradación del dispositivo, no siendo necesaria una elevada precisión de medida para ofrecer resultados exactos de degradación, que sólo podrán medirse en el laboratorio. ABSTRACT. The final degree project "Portable Measurement System For Devices Under Field Tests" is a project undertaken for the development and evaluation of portable and reliable measurement equipment, which allows the realization of I-V curve measurements in field conditions actual operation. Since the purpose of this final project is to obtain a system for conducting field measurements in the implementation of the project will have as main design requirements for size, power supply, system weight, plus reliability and precision relative to the taking of measurements. During the development of this project and given the above requirements portability and reliability, has sought to offer a compromise designing equipment that is achievable, that meets the above objectives with a cost that is not high and the feature that available management facility that allows any user to use it. The final system is designed based on the acquisition device MyDAQ NI data that allows the execution of multiple types of measurements. Based on this data acquisition device, we have designed a measurement system with an architecture that is implemented via a laptop, with measurement software installed that collects and interprets data, and feeds and controls the device through the USB port. The system also implements a variable load which allows measurement of the I-V curve lighting photovoltaic cells. This design allows performing measurements of I-V curves in lighting field is only required to connect the device to purchase a laptop with a battery and variable load. Although this design is specific for the measurement of solar cells has been implemented so that it can easily be extrapolated to other types of measuring voltage and current. To test the accuracy of the portable measurement system during the project has been carried out to compare the results of the designed system, a team of laboratory characterization. This system of high accuracy to quantify the actual degradation of the cell and a comparison of measurements with portable measurement system, providing satisfactory results in all measurements and allowing complete portable system assessment as suitable for measurements of devices field. The evaluation process designed equipment would be far laboratory I-V curve of a photovoltaic device with high precision instrumentation controlled light and temperature of a device, panel or mini-cell conditions. After initial measurement cells settle in a periodic field and device characterization will be achieved through the portable measurement system, which would show whether the I-V curve under illumination degradation exists, and in which area of the curve. At the end of the trial or in interim periods devices to remeasure the I-V curve accurately in laboratory dismount. Therefore the portable measurement system should allow evaluating the evolution of the I-V curve similar to previous measurements obtained in ambient conditions, and from it determine the mode of degradation of the device, not a high measurement accuracy to be necessary to provide degradation accurate results, which can only be measured in the laboratory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El objetivo de este Proyecto Final de Carrera es la realización de un ensayo de fiabilidad de componentes electrónicos, más concretamente de Minimódulos de Silicio, con el fin de estudiar su comportamiento a lo largo del tiempo de vida. Debido a la larga duración de los Minimódulos de Silicio , un ensayo de este tipo podría durar años, por lo que es necesario realizar un ensayo acelerado que acorte significativamente el tiempo del experimento, para ello, han de someterse a esfuerzos mayores que en condiciones normales de funcionamiento. A día de hoy, los Minimódulos de silicio, que conocemos como placas solares fotovoltaicas, se usan en infinidad de dispositivos debido a las múltiples ventajas que conllevan. La principal ventaja es poder llevar electricidad a cualquier parte del planeta sin necesidad de tener que hacer unas elevadas inversiones. Esta electricidad proviene de una fuente de energía inagotable y nada contaminante, con lo que ayudamos a mantener el equilibrio del planeta. La mayoría de las veces estas placas solares fotovoltaicas se usan en el exterior, soportando cambios de temperatura y de humedad elevados, de ahí, la importancia de realizar ensayos de fiabilidad, que muestren sus posibles causas de fallo, los efectos que producen estos fallos y los aspectos de diseño, fabricación y mantenimiento que puedan afectarles. Los Minimódulos de silicio utilizados en este proyecto son el modelo MC-SP0.8-NF-GCS de la empresa fabricante Multicomp. Para realizar el Proyecto hubiéramos necesitado una cámara climática que simulara unas condiciones ambientales determinadas, pero debido a la dificultad de iluminar el módulo dentro de la cámara climática hemos desarrollado un nuevo sistema de ensayos acelerados en temperatura. El nuevo sistema de ensayos acelerados consiste en: •Colocar los módulos fotovoltaicos en el laboratorio con un foco de 500W que irradia lo equivalente al sol. •Los tres módulos trabajarán a tres temperaturas diferentes para simular condiciones ambientales distintas, concretamente a 60°C, 72°C y 84°C. •Mediante un sistema automático de medida diseñado en LabVIEW, de manera simultánea tomará medidas de tensión en las tres placas y estudiaremos el grado degradación en cada placa. Se analizaran los resultados obtenido de cada una de las medidas y se realizará un estudio de fiabilidad y del proceso de degradación sufrido por los Minimódulos de silicio. Este PFC se puede dividir en las siguientes fases de trabajo siendo el ensayo la parte más larga en el tiempo: •Búsqueda de bibliografía documentación y normas aplicables. •Familiarización con los equipos y software, estudiando el manejo del software que viene con el Multímetro Keithley 2601 y el programa LabVIEW. •Desarrollo del hardware y sistemas necesarios para la realización del ensayo. •Montaje del ensayo •Realización del ensayo. •Análisis de resultados. ABSTRACT. The objective of this Final Project is conducting a test reliability of electronic components, more specifically Silicon minimodules, in order to study their behavior throughout the life span. Due to the long duration of Silicon minimodules a test like this could take years, so it is necessary to perform an accelerated significantly shorten the time of the experiment, testing for it, should be subjected to greater efforts than in normal operating. Today, the mini-modules, silicon is known as photovoltaic solar panels are used in a multitude of devices due to the many advantages they bring. The main advantage is to bring electricity to anywhere in the world without having to make high investments. This electricity comes from an inexhaustible source of energy and no pollution, thus helping to maintain the balance of the planet. Most of the time these solar photovoltaic panels are used on the outside, enduring changes in temperature and high humidity, hence, the importance of reliability testing, showing the possible causes of failure, the effects produced by these faults and aspects of design, manufacturing and maintenance that may affect them. The silicon mini-modules used in this project are the MC-SP0.8-NF-GCS model Multicomp manufacturing company. To realize the project we would have needed a climatic chamber to simulate specific environmental conditions, but due to the difficulty of illuminating the module in the climate chamber we have developed a new system of accelerated tests in temperature. The new system is accelerated tests: •Place the PV modules in the laboratory with a focus on the equivalent 500W radiating sun. •The three modules work at three different temperatures to simulate different environmental conditions, namely at 60 °C, 72 °C and 84 °C. •Automatic measurement system designed in LabVIEW, simultaneous voltage measurements taken at the three plates and study the degradation degree in each plate. The results obtained from each of the measurements and a feasibility study and degradation suffered by the silicon is performed minimodules were analyzed. This PFC can be divided into the following phases of the test work the longest part being overtime: •Literature search and documentation standards. •Familiarization with equipment and software, studying management software that comes with the Keithley 2601 multimeter and the LabVIEW program. •Development of hardware and systems necessary for the conduct of the trial. •Experiment setup •Carrying out the experiment. •Analysis of results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El objetivo de este Proyecto Final de Carrera es la realización de un ensayo de fiabilidad de componentes electrónicos, más concretamente de diodos LED, con el fin de estudiar su comportamiento a lo largo del tiempo de vida. Debido a la larga duración de los LEDs, un ensayo de este tipo podría durar años, por lo que es necesario realizar un ensayo acelerado que acorte significativamente el tiempo del experimento, para ello, han de someterse a esfuerzos mayores que en condiciones normales de funcionamiento. En la actualidad, los LEDs son usados en infinidad de aplicaciones, debido a sus múltiples ventajas respecto a otros sistemas de iluminación o señalización convencionales. En numerosos casos se utilizan en el exterior, soportando cambios de temperaturas y de humedad elevados, de ahí, la importancia de realizar ensayos de fiabilidad, que muestren sus posibles causas de fallo, los efectos que producen estos fallos y los aspectos de diseño, fabricación y mantenimiento que puedan afectarles. Como consecuencia del envejecimiento de los LEDs, pueden mostrar una reducción en el flujo luminoso y un empeoramiento de las propiedades cromáticas. Los LEDs utilizados en este Proyecto son de AlInGaP, rojos, de alta luminosidad. Para acelerar el ensayo, se utilizará una cámara climática que simule unas condiciones ambientales determinadas, en concreto, 85º C y 85% HR. Además, se realiza una monitorización periódica, siendo necesaria la utilización de un sistema automático de medida diseñado en LabVIEW, el cual, de manera simultánea realizará medidas y gestionará la inyección de corriente a los LEDs mientras se encuentren en el interior de la cámara climática. Se fabrican dos placas con 4 tiras de LEDs para inyectar un nivel de corriente diferente en cada una y así poder comparar la degradación en función de este parámetro. Fuera de la cámara climática se van a medir las curvas características de tensióncorriente de cada LED a una temperatura ambiente constante, fijada por un módulo Peltier. También se realizarán medidas de potencia luminosa y de espectro de emisión. Se analizarán los resultados obtenidos de cada una de las medidas y se realizará un estudio de fiabilidad y del proceso de degradación sufrido por los LEDs. Este PFC se puede dividir en las siguientes fases de trabajo, siendo el ensayo la parte más larga en el tiempo: · Búsqueda de bibliografía, documentación y normas aplicables. · Familiarización con los equipos y software, estudiando el manejo y funcionamiento de la cámara climática temperatura-humedad y el software a aplicar (LabVIEW y software del espectrómetro). · Desarrollo del hardware y sistemas necesarios para la realización del ensayo. · Realización del ensayo. · Análisis de resultados. ABSTRACT. The objective of this end of degree project is conducting an essay reliability of electronic components, more concretely LEDs, in order to study their behavior throughout its lifespan. Due to the long duration of the LEDs, a essay of this type could last for years, so it is necessary to perform an accelerated essay which significantly shorten the time of the experiment, testing should be subjected to greater efforts than in normal operation. Today, LEDs are used in many applications due to its many advantages over other conventional lighting systems or signaling. In numerous cases are used on the outside, enduring high changes in temperature and humidity, hence the importance of reliability essays, showing the possible causes of failure, the effects produced by these failures and aspects of design, manufacturing and maintenance that may affect them. As a result of the ageing of the LEDs, they may show a reduction in light output and a worsening of the chromatic properties. The LEDs used in this project are AlInGaP, red and high brightness. To speed up the essay will be used a climatic chamber to simulate specific environmental conditions, specifically 85 ° C and 85 % RH. In addition, is pe rformed a periodic monitoring using an automatic measurement system designed in LabVIEW , which , simultaneously will performed measurements and will manage the injection current to the LEDs while are inside of the climatic chamber. 4 strips of LEDs are created to inject a different level of current in each, so can compare the degradation in terms of this parameter. Out of the climatic chamber are obtained the characteristic curves of voltage-current of each LED at a constant room temperature, set by a Peltier module. Also, measures light power and the emitted spectrum. The results of each of the measures and a reliability study and degradation suffered by the LEDs will be discussed. This PFC can be divided into the following steps, the essay being the longest part: • Search bibliography, documentation and standards. • Familiarization with equipment and software, studying the management and the operation of the temperature-humidity environmental chamber and applying software (LabVIEW applications and spectrometer software). • Development of hardware and systems necessary for the conduct of the essay. • Carrying out the essay. • Analysis of results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La calidad del hormigón prefabricado se determina mediante ensayos de rotura a compresión en probetas transcurridos los 28 días de curado, según establece la EHE-08. Sin embargo, en la plantas de prefabricados es necesario además saber cuándo el hormigón está listo para ser procesado (destensado, cortado, trasladado), por lo que es necesario hacer ensayos de resistencia a la compresión entre las 48 y 72 horas, este tiempo se determina a partir de la experiencia previa adquirida y depende de las condiciones de cada planta. Si las probetas no han alcanzado el valor establecido, normalmente debido a un cambio en las condiciones climatológicas o en los materiales utilizados como el tipo de cemento o agregados, la solución adoptada suele ser dejar curar el material más horas en la pista para que alcance la resistencia necesaria para ser procesado. Si sigue sin alcanzarla, lo cual sucede muy ocasionalmente, se intenta analizar cuál ha sido el motivo, pudiéndose tirar toda la producción de ese día si se comprueba que ha sido un fallo en la fabricación de la línea, y no un fallo de la probeta. Por tanto, esta metodología de control de calidad, basada en técnicas destructivas, supone dos tipos de problemas, costes y representatividad. Los métodos no destructivos que más se han aplicado para caracterizar el proceso de curado del hormigón son los ultrasónicos y la medida de la temperatura como se recoge en la bibliografía consultada. Hay diferentes modelos que permiten establecer una relación entre la temperatura y el tiempo de curado para estimar la resistencia a compresión del material, y entre la velocidad de propagación ultrasónica y la resistencia. Aunque estas relaciones no son generales, se han obtenido muy buenos resultados, ejemplo de ello es el modelo basado en la temperatura, Maturity Method, que forma parte de la norma de la ASTM C 1074 y en el mercado hay disponibles equipos comerciales (maturity meters) para medir el curado del hormigón. Además, es posible diseñar sistemas de medida de estos dos parámetros económicos y robustos; por lo cual es viable la realización de una metodología para el control de calidad del curado que pueda ser implantado en las plantas de producción de prefabricado. En este trabajo se ha desarrollado una metodología que permite estimar la resistencia a la compresión del hormigón durante el curado, la cual consta de un procedimiento para el control de calidad del prefabricado y un sistema inalámbrico de sensores para la medida de la temperatura y la velocidad ultrasónica. El procedimiento para el control de calidad permite realizar una predicción de la resistencia a compresión a partir de un modelo basado en la temperatura de curado y otros dos basados en la velocidad, método de tiempo equivalente y método lineal. El sistema inalámbrico de sensores desarrollado, WilTempUS, integra en el mismo dispositivo sensores de temperatura, humedad relativa y ultrasonidos. La validación experimental se ha realizado mediante monitorizaciones en probetas y en las líneas de prefabricados. Los resultados obtenidos con los modelos de estimación y el sistema de medida desarrollado muestran que es posible predecir la resistencia en prefabricados de hormigón en planta con errores comparables a los aceptables por norma en los ensayos de resistencia a compresión en probetas. ABSTRACT Precast concrete quality is determined by compression tests breakage on specimens after 28 days of curing, as established EHE-08. However, in the precast plants is also necessary to know when the concrete is ready to be processed (slack, cut, moved), so it is necessary to test the compressive strength between 48 and 72 hours. This time is determined from prior experience and depends on the conditions of each plant. If the samples have not reached the set value, usually due to changes in the weather conditions or in the materials used as for example the type of cement or aggregates, the solution usually adopted is to cure the material on track during more time to reach the required strength for processing. If the material still does not reach this strength, which happens very occasionally, the reason of this behavior is analyzed , being able to throw the entire production of that day if there was a failure in the manufacturing line, not a failure of the specimen. Therefore, this method of quality control, using destructive techniques, involves two kinds of problems, costs and representativeness. The most used non-destructive methods to characterize the curing process of concrete are those based on ultrasonic and temperature measurement as stated in the literature. There are different models to establish a relationship between temperature and the curing time to estimate the compressive strength of the material, and between the ultrasonic propagation velocity and the compressive strength. Although these relationships are not general, they have been very successful, for example the Maturity Method is based on the temperature measurements. This method is part of the standards established in ASTM C 1074 and there are commercial equipments available (maturity meters) in the market to measure the concrete curing. Furthermore, it is possible to design inexpensive and robust systems to measure ultrasounds and temperature. Therefore is feasible to determine a method for quality control of curing to be implanted in the precast production plants. In this work, it has been developed a methodology which allows to estimate the compressive strength of concrete during its curing process. This methodology consists of a procedure for quality control of the precast concrete and a wireless sensor network to measure the temperature and ultrasonic velocity. The procedure for quality control allows to predict the compressive strength using a model based on the curing temperature and two other models based on ultrasonic velocity, the equivalent time method and the lineal one. The wireless sensor network, WilTempUS, integrates is the same device temperature, relative humidity and ultrasonic sensors. The experimental validation has been carried out in cubic specimens and in the production plants. The results obtained with the estimation models and the measurement system developed in this thesis show that it is possible to predict the strength in precast concrete plants with errors within the limits of the standards for testing compressive strength specimens.