918 resultados para PROSTHETIC COMPLICATIONS
Resumo:
Study Design Retrospective review of prospectively collected data. Objectives To analyze intervertebral (IV) fusion after thoracoscopic anterior spinal fusion (TASF) and explore the relationship between fusion scores and key clinical variables. Summary of Background Information TASF provides comparable correction with some advantages over posterior approaches but reported mechanical complications, and their relationship to non-union and graft material is unclear. Similarly, the optimal combination of graft type and implant stiffness for effecting successful radiologic union remains undetermined. Methods A subset of patients from a large single-center series who had TASF for progressive scoliosis underwent low-dose computed tomographic scans 2 years after surgery. The IV fusion mass in the disc space was assessed using the 4-point Sucato scale, where 1 indicates <50% and 4 indicates 100% bony fusion of the disc space. The effects of rod diameter, rod material, graft type, fusion level, and mechanical complications on fusion scores were assessed. Results Forty-three patients with right thoracic major curves (mean age 14.9 years) participated in the study. Mean fusion scores for patient subgroups ranged from 1.0 (IV levels with rod fractures) to 2.2 (4.5-mm rod with allograft), with scores tending to decrease with increasing rod size and stiffness. Graft type (autograft vs. allograft) did not affect fusion scores. Fusion scores were highest in the middle levels of the rod construct (mean 2.52), dropping off by 20% to 30% toward the upper and lower extremities of the rod. IV levels where a rod fractured had lower overall mean fusion scores compared to levels without a fracture. Mean total Scoliosis Research Society (SRS) questionnaire scores were 98.9 from a possible total of 120, indicating a good level of patient satisfaction. Conclusions Results suggest that 100% radiologic fusion of the entire disc space is not necessary for successful clinical outcomes following thoracoscopic anterior selective thoracic fusion.
Resumo:
Background Guidelines and clinical practice for the prevention of complications associated with central venous catheters (CVC) around the world vary greatly. Most institutions recommend the use of heparin to prevent occlusion, however there is debate regarding the need for heparin and evidence to suggest 0.9% sodium chloride (normal saline) may be as effective. The use of heparin is not without risk, may be unnecessary and is also associated with increased cost. Objectives To assess the clinical effects (benefits and harms) of intermittent flushing of heparin versus normal saline to prevent occlusion in long term central venous catheters in infants and children. Search Methods The Cochrane Vascular Trials Search Co-ordinator searched the Specialised Register (last searched April 2015) and the Cochrane Register of Studies (Issue 3, 2015). We also searched the reference lists of retrieved trials. Selection criteria Randomised controlled trials that compared the efficacy of normal saline with heparin to prevent occlusion of long term CVCs in infants and children aged up to 18 years of age were included. We excluded temporary CVCs and peripherally inserted central catheters (PICC). Data Collection and Analysis Two review authors independently assessed trial inclusion criteria, trial quality and extracted data. Rate ratios were calculated for two outcome measures - occlusion of the CVC and central line-associated blood stream infection. Other outcome measures included duration of catheter placement, inability to withdraw blood from the catheter, use of urokinase or recombinant tissue plasminogen, incidence of removal or re-insertion of the catheter, or both, and other CVC-related complications such as dislocation of CVCs, other CVC site infections and thrombosis. Main Results Three trials with a total of 245 participants were included in this review. The three trials directly compared the use of normal saline and heparin, however, between studies, all used different protocols for the standard and experimental arms with different concentrations of heparin and different frequency of flushes reported. In addition, not all studies reported on all outcomes. The quality of the evidence ranged from low to very low because there was no blinding, heterogeneity and inconsistency between studies was high and the confidence intervals were wide. CVC occlusion was assessed in all three trials (243 participants). We were able to pool the results of two trials for the outcomes of CVC occlusion and CVC-associated blood stream infection. The estimated rate ratio for CVC occlusion per 1000 catheter days between the normal saline and heparin group was 0.75 (95% CI 0.10 to 5.51, two studies, 229 participants, very low quality evidence). The estimated rate ratio for CVC-associated blood stream infection was 1.48 (95% CI 0.24 to 9.37, two studies, 231 participants; low quality evidence). The duration of catheter placement was reported to be similar between the two study arms, in one study (203 participants). Authors' Conclusions The review found that there was not enough evidence to determine the effects of intermittent flushing of heparin versus normal saline to prevent occlusion in long term central venous catheters in infants and children. Ultimately, if this evidence were available, the development of evidenced-based clinical practice guidelines and consistency of practice would be facilitated.
Resumo:
This article provides an overview of the care of patients undergoing limb amputation. Absence of a limb can be congenital or the result of trauma or complications of chronic diseases. While the economic burden of limb amputation is significant, nurses have an important role in limiting other losses attributable to limb loss, such as long-term disability leading to loss of employment and delayed return to work or school. Comprehensive nursing assessments and appropriate interventions, pre and post-operatively, as well as early discharge planning and community reintegration can help avoid some of these losses. Nurses should be aware of the resources available in communities and work in multidisciplinary teams to ensure optimal outcomes for patients following limb amputation and their families.
Resumo:
Orthotopic liver transplantation began in Brisbane in January 1985. During the first two years of the programme an assessment committee evaluated 55 patients (38 adults, 17 children). Patients were either accepted for transplantation, rejected as unsuitable or deferred for elective reassessment. All of the 10 adults who were rejected for transplantation because they had 'too advanced' disease died within four months of assessment. Six children who were accepted for transplantation died before a suitable donor liver could be found. In the first two years, 21 orthotopic liver transplantations were performed on 18 patients (adults, 13 patients; children, five patients). Fifteen of 21 grafts were procured from within Queensland. Twelve (67%) patients are alive at three to 23 months and all have been discharged from hospital. Deaths in adults were due to sepsis (three patients), aspiration pneumonitis (one patient), rejection and hepatic artery thrombosis (one patient) and the recurrence of a hepatocellular carcinoma five months after discharge from hospital (one patient). Two patients underwent a second transplantation procedure because of chronic rejection at four months and at 11 months, respectively, after the initial operation. One patient received a second transplant for primary graft failure at four days after the operation. A scoring system which considered the presence of pre-operative patient factors, such as coma, ascites, malnutrition and previous abdominal surgery, partly predicted the operative blood loss and patient survival. In conclusion, orthotopic liver transplantation is being performed in Australia with survival rates that are comparable with those of established overseas units.
Resumo:
Children with end-stage liver disease now form a major sub-group of patients considered suitable for liver transplantation (ltp), and enjoy better survival statistics after transplantation than do adults. Since June 1984, a paediatric ltp programme has been developed in Brisbane with an initial working relationship and ongoing close links with two USA centres (Pittsburgh, and the UCLA Medical Center). Fourteen children with end-stage liver disease have been referred to the Queensland Liver Transplantation Programme for formal assessment. Following frank, informed discussion with their parents, 10 of these children were offered the option of ltp. During the transition stage, two infants with biliary atresia were referred to UCLA at their parents' request and, subsequently, eight children aged from 9 months to 6 years have been placed on a transplant candidacy list in Brisbane. A donor procurement team with access to a Queensland Government jet has been available to cover all mainland States except Western Australia. Six of the children have now had orthotopic ltp (two children at the UCLA Medical Center; four children at the Royal Children's Hospital, Brisbane). One UCLA patient died with a non-functioning graft, and one Brisbane patient died 5 weeks post-transplant with rejection, hepatic artery thrombosis and sepsis. The other four children are alive and well, three with normal liver function and one with unexplained intrahepatic cholestasis, during the 1-20 month follow-up to date. Three further children have died of their liver disease without a donor of an appropriate blood group and size being found, and one patient still awaits a suitable donor. The experience of these authors suggests that ltp is a major advance in the treatment of paediatric liver disease, and that the procedure can be carried out successfully in Australia with initial results comparable with leading overseas centres. The procedure requires the full array of services of a major paediatric tertiary care facility, an intensive team effort with awareness of the special needs of children, and a widespread procurement capability. A major problem for Australia is the procurement of sufficient numbers of optimal paediatric donor livers.
Resumo:
Developments of surgical attachments for bone-anchored prostheses are slowly but surely winning over the initial disbelief in the orthopedic community. Clearly, this option is becoming accessible to a wide range of individuals with limb loss. Seminal studies have demonstrated that the pioneering procedure relying on screw-type fixation engenders major clinical benefits and acceptable safety. The surgical procedure for press-fit implants, such as the Integral-Leg-Prosthesis (ILP) has been described Dr Aschoff and his team. Some clinical benefits of press-fit implants have been also established. Here, his team is once again taking a leading role by sharing the progression over 15 years of the rate of deep infections for 69 individuals with transfemoral amputation fitted with three successive refined versions of the ILP. By definition, a double-blind randomized clinical trial to test the effect of different fixation’s design is difficult. Alternatively, Juhnke and colleagues are reporting the outcomes of action-research study for a cohort of participants. The first and foremost important outcome of this study is the confirmation that the current design of the IPL and rehabilitation program are altogether leading to an acceptable rate of deep infection and other adverse events (e.g., structural failure of implant, periprosthetic factures). This study is also providing a strong insight onto the effect of major phases in redesign of an implant on the risk of infection. This is an important reminder that the development of a successful osseointegrated implant is unlikely to be immediate but the results of a learning curve made of empirical and sequential changes led by a reflective clinical practice. Clearly, this study provided better understanding of the safety of the ILP surgical and rehabilitation procedure while establishing standards and benchmark data for future studies focusing on design and infection of press-fit implants. Complementary observations of relationship between infection and cofounders such as loading of the prosthesis and prosthetic components used would be beneficial.Further definitive evidences of the clinical benefits with the latest design would be valuable, although an increase in health related quality of life and functional outcomes are likely to be confirmed. Altogether, the authors are providing compelling evidence that bone-anchored attachments particularly those relying on press-fit implants are an established alternative to socket prostheses.
Resumo:
Purpose This study evaluated the impact of patient set-up errors on the probability of pulmonary and cardiac complications in the irradiation of left-sided breast cancer. Methods and Materials Using the CMS XiO Version 4.6 (CMS Inc., St Louis, MO) radiotherapy planning system's NTCP algorithm and the Lyman -Kutcher-Burman (LKB) model, we calculated the DVH indices for the ipsilateral lung and heart and the resultant normal tissue complication probabilities (NTCP) for radiation-induced pneumonitis and excess cardiac mortality in 12 left-sided breast cancer patients. Results Isocenter shifts in the posterior direction had the greatest effect on the lung V20, heart V25, mean and maximum doses to the lung and the heart. Dose volume histograms (DVH) results show that the ipsilateral lung V20 tolerance was exceeded in 58% of the patients after 1cm posterior shifts. Similarly, the heart V25 tolerance was exceeded after 1cm antero-posterior and left-right isocentric shifts in 70% of the patients. The baseline NTCPs for radiation-induced pneumonitis ranged from 0.73% - 3.4% with a mean value of 1.7%. The maximum reported NTCP for radiation-induced pneumonitis was 5.8% (mean 2.6%) after 1cm posterior isocentric shift. The NTCP for excess cardiac mortality were 0 % in 100% of the patients (n=12) before and after setup error simulations. Conclusions Set-up errors in left sided breast cancer patients have a statistically significant impact on the Lung NTCPs and DVH indices. However, with a central lung distance of 3cm or less (CLD <3cm), and a maximum heart distance of 1.5cm or less (MHD<1.5cm), the treatment plans could tolerate set-up errors of up to 1cm without any change in the NTCP to the heart.
Resumo:
The standard Gibbs energy change accompanying the conversion of rare earth oxides to oxysulfides by reaction of rare earth oxides with diatomic sulfur gas has been measured in the temperature range 870 to 1300 K using the solid state cell: Pt/Cu+Cu2S/R2O2S+R2O3‖(CaO)ZrO2‖Ni+NiO, Pt where R=La, Nd, Sm, Gd, Tb, and Dy. The partial pressure of diatomic sulfur over a mixture of rare earth oxide (R2O3) and oxysulfide (R2O2S) is fixed by the dissociation of Cu2S to Cu in a closed system. The buffer mixture of Cu+Cu2S is physically separated from the rare earth oxide and oxysulfide to avoid complications arising from interaction between them. The corresponding equilibrium oxygen partial pressure is measured with an oxide solid electrolyte cell. Gibbs energy change for the conversion of oxide to the corresponding oxysulfide increases monotonically with atomic number of the rare earth element. Second law enthalpy of formation also shows a similar trend. Based on this empirical trend Gibbs energies of formation of oxysulfides of Pr, Eu, Ho, and Er are estimated as a function of temperature.
Resumo:
Use of socket prostheses Currently, for individuals with limb loss, the conventional method of attaching a prosthetic limb relies on a socket that fits over the residual limb. However, there are a number of issues concerning the use of a socket (e.g., blisters, irritation, and discomfort) that result in dissatisfaction with socket prostheses, and these lead ultimately a significant decrease in quality of life. Bone-anchored prosthesis Alternatively, the concept of attaching artificial limbs directly to the skeletal system has been developed (bone anchored prostheses), as it alleviates many of the issues surrounding the conventional socket interface.Bone anchored prostheses rely on two critical components: the implant, and the percutaneous abutment or adapter, which forms the connection for the external prosthetic system (Figure 1). To date, an implant that screws into the long bone of the residual limb has been the most common intervention. However, more recently, press-fit implants have been introduced and their use is increasing. Several other devices are currently at various stages of development, particularly in Europe and the United States. Benefits of bone-anchored prostheses Several key studies have demonstrated that bone-anchored prostheses have major clinical benefits when compared to socket prostheses (e.g., quality of life, prosthetic use, body image, hip range of motion, sitting comfort, ease of donning and doffing, osseoperception (proprioception), walking ability) and acceptable safety, in terms of implant stability and infection. Additionally, this method of attachment allows amputees to participate in a wide range of daily activities for a substantially longer duration. Overall, the system has demonstrated a significant enhancement to quality of life. Challenges of direct skeletal attachment However, due to the direct skeletal attachment, serious injury and damage can occur through excessive loading events such as during a fall (e.g., component damage, peri-prosthetic fracture, hip dislocation, and femoral head fracture). These incidents are costly (e.g., replacement of components) and could require further surgical interventions. Currently, these risks are limiting the acceptance of bone-anchored technology and the substantial improvement to quality of life that this treatment offers. An in-depth investigation into these risks highlighted a clear need to re-design and improve the componentry in the system (Figure 2), to improve the overall safety during excessive loading events. Aim and purposes The ultimate aim of this doctoral research is to improve the loading safety of bone-anchored prostheses, to reduce the incidence of injury and damage through the design of load restricting components, enabling individuals fitted with the system to partake in everyday activities, with increased security and self-assurance. The safety component will be designed to release or ‘fail’ external to the limb, in a way that protects the internal bone-implant interface, thus removing the need for restorative surgery and potential damage to the bone. This requires detailed knowledge of the loads typically experienced by the limb and an understanding of potential overload situations that might occur. Hence, a comprehensive review of the loading literature surrounding bone anchored prostheses will be conducted as part of this project, with the potential for additional experimental studies of the loads during normal activities to fill in gaps in the literature. This information will be pivotal in determining the specifications for the properties of the safety component, and the bone-implant system. The project will follow the Stanford Biodesign process for the development of the safety component.
Resumo:
Objective: To examine the association between preoperative quality of life (QoL) and postoperative adverse events in women treated for endometrial cancer. Methods: 760 women with apparent Stage I endometrial cancer were randomised into a clinical trial evaluating laparoscopic versus open surgery. This analysis includes women with preoperative QoL measurements, from the Functional Assessment of Cancer Therapy- General (FACT-G) questionnaire, and who were followed up for at least 6 weeks after surgery (n=684). The outcomes for this study were defined as (1) the occurrence of moderate to severe AEs adverse events within 6 months (Common Toxicology Criteria (CTC) grade ≥3); and (2) any Serious Adverse Event (SAE). The association between preoperative QoL and the occurrence of AE was examined, after controlling for baseline comorbidity and other factors. Results: After adjusting for other factors, odds of occurrence of AE of CTC grade ≥3 were significantly increased with each unit decrease in baseline FACT-G score (OR=1.02, 95% CI 1.00-1.03, p=0.030), which was driven by physical well-being (PWB) (OR=1.09, 95% CI 1.04-1.13, p=0.0002) and functional well-being subscales (FWB) (OR=1.04, 95% CI 1.00-1.07, p=0.035). Similarly, odds of SAE occurrence were significantly increased with each unit decrease in baseline FACT-G score (OR=1.02, 95% CI 1.01-1.04, p=0.011), baseline PWB (OR=1.11, 95% CI 1.06-1.16, p<0.0001) or baseline FWB subscales (OR=1.05, 95% CI 1.01-1.10, p=0.0077). Conclusion: Women with early endometrial cancer presenting with lower QoL prior to surgery are at higher risk of developing a serious adverse event following surgery. Funding: Cancer Council Queensland, Cancer Council New South Wales, Cancer Council Victoria, Cancer Council, Western Australia; NHMRC project grant 456110; Cancer Australia project grant 631523; The Women and Infants Research Foundation, Western Australia; Royal Brisbane and Women’s Hospital Foundation; Wesley Research Institute; Gallipoli Research Foundation; Gynetech; TYCO Healthcare, Australia; Johnson and Johnson Medical, Australia; Hunter New England Centre for Gynaecological Cancer; Genesis Oncology Trust; and Smart Health Research Grant QLD Health.
Resumo:
Historically, determining the country of origin of a published work presented few challenges, because works were generally published physically – whether in print or otherwise – in a distinct location or few locations. However, publishing opportunities presented by new technologies mean that we now live in a world of simultaneous publication – works that are first published online are published simultaneously to every country in world in which there is Internet connectivity. While this is certainly advantageous for the dissemination and impact of information and creative works, it creates potential complications under the Berne Convention for the Protection of Literary and Artistic Works (“Berne Convention”), an international intellectual property agreement to which most countries in the world now subscribe. Under the Berne Convention’s national treatment provisions, rights accorded to foreign copyright works may not be subject to any formality, such as registration requirements (although member countries are free to impose formalities in relation to domestic copyright works). In Kernel Records Oy v. Timothy Mosley p/k/a Timbaland, et al. however, the Florida Southern District Court of the United States ruled that first publication of a work on the Internet via an Australian website constituted “simultaneous publication all over the world,” and therefore rendered the work a “United States work” under the definition in section 101 of the U.S. Copyright Act, subjecting the work to registration formality under section 411. This ruling is in sharp contrast with an earlier decision delivered by the Delaware District Court in Håkan Moberg v. 33T LLC, et al. which arrived at an opposite conclusion. The conflicting rulings of the U.S. courts reveal the problems posed by new forms of publishing online and demonstrate a compelling need for further harmonization between the Berne Convention, domestic laws and the practical realities of digital publishing. In this chapter, we argue that even if a work first published online can be considered to be simultaneously published all over the world it does not follow that any country can assert itself as the “country of origin” of the work for the purpose of imposing domestic copyright formalities. More specifically, we argue that the meaning of “United States work” under the U.S. Copyright Act should be interpreted in line with the presumption against extraterritorial application of domestic law to limit its application to only those works with a real and substantial connection to the United States. There are gaps in the Berne Convention’s articulation of “country of origin” which provide scope for judicial interpretation, at a national level, of the most pragmatic way forward in reconciling the goals of the Berne Convention with the practical requirements of domestic law. We believe that the uncertainties arising under the Berne Convention created by new forms of online publishing can be resolved at a national level by the sensible application of principles of statutory interpretation by the courts. While at the international level we may need a clearer consensus on what amounts to “simultaneous publication” in the digital age, state practice may mean that we do not yet need to explore textual changes to the Berne Convention.
Resumo:
Introduction and Objectives Joint moments and joint powers during gait are widely used to determine the effects of rehabilitation programs as well as prosthetic fitting. Following the definition of power (dot product of joint moment and joint angular velocity) it has been previously proposed to analyse the 3D angle between both vectors, αMw. Basically, joint power is maximised when both vectors are parallel and cancelled when both vectors are orthogonal. In other words, αMw < 60° reveals a propulsion configuration (more than 50% of the moment contribute to positive power) while αMw > 120° reveals a resistance configuration (more than 50% of the moment contribute to negative power). A stabilisation configuration (less than 50% of the moment contribute to power) corresponds to 60° < αMw < 120°. Previous studies demonstrated that hip joints of able-bodied adults (AB) are mainly in a stabilisation configuration (αMw about 90°) during the stance phase of gait. [1, 2] Individuals with transfemoral amputation (TFA) need to maximise joint power at the hip while controlling the prosthetic knee during stance. Therefore, we tested the hypothesis that TFAs should adopt a strategy that is different from a continuous stabilisation. The objective of this study was to compute joint power and αMw for TFA and to compare them with AB. Methods Three trials of walking at self-selected speed were analysed for 8 TFAs (7 males and 1 female, 46±10 years old, 1.78±0.08 m 82±13 kg) and 8 ABs (males, 25±3 years old, 1.75±0.04, m 67±6 kg). The joint moments are computed from a motion analysis system (Qualisys, Goteborg, Sweden) and a multi-axial transducer (JR3, Woodland, USA) mounted above the prosthetic knee for TFAs and from a motion analysis system (Motion Analysis, Santa Rosa, USA) and force plates (Bertec, Columbus, USA) for ABs. The TFAs were fitted with an OPRA (Integrum, AB, Gothengurg, Sweden) osseointegrated implant system and their prosthetic designs include pneumatic, hydraulic and microprocessor knees. Previous studies showed that the inverse dynamics computed from the multi-axial transducer is the proper method considering the absorption at the foot and resistance at the knee. Results The peak of positive power at loading response (H1) was earlier and lower for TFA compared to AB. Although the joint power is lower, the 3D angle between joint moment and joint angular velocity, αMw, reveals an obvious propulsion configuration (mean αMw about 20°) for TFA compared to a stabilisation configuration (mean αMw about 70°) for AB. The peaks of negative power at midstance (H2) and of positive power at preswing / initial swing (H3) occurred later, lower and longer for TFA compared to AB. Again, the joint powers are lower for TFA but, in this case, αMw is almost comparable (with a time lag), demonstrating a stabilisation (almost a resistance for TFA, mean αMw about 120°) and a propulsion configuration, respectively. The swing phase is not analysed in the present study. Conclusion The analysis of hip joint power may indicate that TFAs demonstrated less propulsion and resistance than ABs during the stance phase of gait. This is true from a quantitative point of view. On the contrary, the 3D angle between joint moment and joint angular velocity, αMw, reveals that TFAs have a remarkable propulsion strategy at loading response and almost a resistance strategy at midstance while ABs adopted a stabilisation strategy. The propulsion configuration, with αMw close to 0°, seems to aim at maximising the positive joint power. The configuration close to resistance, with αMw far from 180°, might aim at unlocking the prosthetic knee before swing while minimising the negative power. This analysis of both joint power and 3D angle between the joint moment and the joint angular velocity provides complementary insights into the gait strategies of TFA that can be used to support evidence-based rehabilitation and fitting of prosthetic components.
Resumo:
Total hip replacement is the golden standard treatment for severe osteoarthritis refractory for conservative treatment. Aseptic loosening and osteolysis are the major long-term complications after total hip replacement. Foreign body giant cells and osteoclasts are locally formed around aseptically loosening implants from precursor cells by cell fusion. When the foreign body response is fully developed, it mediates inflammatory and destructive host responses, such as collagen degradation. In the present study, it was hypothesized that the wear debris and foreign body inflammation are the forces driving local osteoclast formation, peri-implant bone resorption and enhanced tissue remodeling. Therefore the object was to characterize the eventual expression and the role of fusion molecules, ADAMs (an abbreviation for A Disintegrin And Metalloproteinase, ADAM9 and ADAM12) in the fusion of progenitor cells into multinuclear giant cells. For generation of such cells, activated macrophages trying to respond to foreign debris play an important role. Matured osteoclasts together with activated macrophages mediate bone destruction by secreting protons and proteinases, including matrix metalloproteinases (MMPs) and cathepsin K. Thus this study also assessed collagen degradation and its relationship to some of the key collagenolytic proteinases in the aggressive synovial membrane-like interface tissue around aseptically loosened hip replacement implants. ADAMs were found in the interface tissues of revision total hip replacement patients. Increased expression of ADAMs at both transcriptional and translational levels was found in synovial membrane-like interface tissue of revision total hip replacement (THR) samples compared with that in primary THR samples. These studies also demonstrate that multinucleate cell formation from monocytes by stimulation with macrophage-colony stimiulating factor (M-CSF) and receptor activator of nuclear factor kappa B ligand (RANKL) is characterized by time dependent changes of the proportion of ADAMs positive cells. This was observed both in the interface membrane in patients and in two different in vitro models. In addition to an already established MCS-F and RANKL driven model, a new virally (parainfluenza 2) driven model (of human salivary adenocarcinoma (HSY) cells or green monkey kidney (GMK) cells) was developed to study various fusion molecules and their role in cell fusion in general. In interface membranes, collagen was highly degraded and collagen degradation significantly correlated with the number of local cells containing collagenolytic enzymes, particularly cathepsin K. As a conclusion, fusion molecules ADAM9 and ADAM12 seem to be dynamically involved in cell-cell fusion processes and multinucleate cell formation. The highly significant correlation between collagen degradation and collagenolytic enzymes, particularly cathepsin K, indicates that the local acidity of the interface membrane in the pathologic bone and soft tissue destruction. This study provides profound knowledge about cell fusion and mechanism responsible for aseptic loosening as well as increases knowledge helpful for prevention and treatment.
Resumo:
There is some evidence that self-rated perceptions of health are predictive of objective health outcomes, including cardiovascular disease, and mortality. The objective of this study was to examine the prospective association between perceptions of health during pregnancy and cardiovascular risk factors of mothers 21 years after the pregnancy. Data used were from the Mater University Study of Pregnancy (MUSP), a community-based prospective birth cohort study begun in Brisbane, Australia, in 1981. Logistic regression analyses were conducted. Data were available for 3692 women. Women who perceived themselves as not having a straight forward pregnancy had twice the odds (adjusted OR 2.0, 95% CI 1.1–3.8) of being diagnosed with heart disease 21 years after the pregnancy when compared with women with a straight forward pregnancy (event rate of 5.2 versus 2.6%). Women who experienced complications (other than serious pregnancy complications) during their pregnancy were also at 30% increased odds (adjusted OR 1.3, 95% CI 1.0–1.6) of having hypertension 21years later (event rate of 25.7 versus 20%). As a whole, our study sug- gests that pregnant women who perceived that they had complications and did not have a straight forward preg- nancy were likely to experience poorer cardiovascular outcomes 21years after that pregnancy.