940 resultados para One Up Bond F
Resumo:
Weight gain is often associated with smoking cessation and may discourage smokers from quitting. This study estimated the weight gained one year after smoking cessation and examined the risk factors associated with weight gain in order to identify socio-demographic groups at higher risk of increased weight after quitting. We analyzed data from 750 adults in two randomized controlled studies that included smokers motivated to quit and found a gradient in weight gain according to the actual duration of abstinence during follow-up. Subjects who were abstinent for at least 40 weeks gained 4.6 kg (SD = 3.8) on average, compared to 1.2 kg (SD = 2.6) for those who were abstinent less than 20 weeks during the 1-year follow-up. Considering the duration of abstinence as an exposure variable, we found an age effect and a significant interaction between sex and the amount of smoking before quitting: younger subjects gained more weight than older subjects; among light smokers, men gained more weight on average than women one year after quitting, while the opposite was observed among heavy smokers. Young women smoking heavily at baseline had the highest risk of weight gain after quitting.
Resumo:
Our contribution analyses the influence of campaign advertisements on vote choice in the 2011 elections to the Swiss National Council. Concretely, we ask whether and to what extent the relative exposure to party ads of a preferred party exerts a reinforcing effect on an individual's party choice. We make use of the two-wave panel structure contained in the RCS survey data of the Selects 2011 and combine it with data on advertisements in 20 important national and regional newspapers. We find that increasing exposure to the campaign of one's preferred party may reinforce individuals with strong party attachment in their initial vote choice. Yet this effect only materializes with substantial campaign duration and exposure. Additional and exploratory analyses revealed that particularly the two recently emerged parties, the GLP and BDP, might have made a slight difference by potentially persuading defecting voters with the help of their campaign.
Resumo:
The gas-phase rotational motion of hexafluorobenzene has been measured in real time using femtosecond (fs) time-resolved rotational Raman coherence spectroscopy (RR-RCS) at T = 100 and 295 K. This four-wave mixing method allows to probe the rotation of non-polar gas-phase molecules with fs time resolution over times up to ∼5 ns. The ground state rotational constant of hexafluorobenzene is determined as B 0 = 1029.740(28) MHz (2σ uncertainty) from RR-RCS transients measured in a pulsed seeded supersonic jet, where essentially only the v = 0 state is populated. Using this B 0 value, RR-RCS measurements in a room temperature gas cell give the rotational constants B v of the five lowest-lying thermally populated vibrationally excited states ν7/8, ν9, ν11/12, ν13, and ν14/15. Their B v constants differ from B 0 by between −1.02 MHz and +2.23 MHz. Combining the B 0 with the results of all-electron coupled-cluster CCSD(T) calculations of Demaison et al. [Mol. Phys.111, 1539 (2013)] and of our own allow to determine the C-C and C-F semi-experimental equilibrium bond lengths r e(C-C) = 1.3866(3) Å and r e(C-F) = 1.3244(4) Å. These agree with the CCSD(T)/wCVQZ r e bond lengths calculated by Demaison et al. within ±0.0005 Å. We also calculate the semi-experimental thermally averaged bond lengths r g(C-C)=1.3907(3) Å and r g(C-F)=1.3250(4) Å. These are at least ten times more accurate than two sets of experimental gas-phase electron diffraction r g bond lengths measured in the 1960s.
Resumo:
Δ(9)-tetrahydrocannabinol (Δ(9)-THC) is the major psychoactive cannabinoid in hemp (Cannabis sativa L.) and responsible for many of the pharmacological effects mediated via cannabinoid receptors. Despite being the major cannabinoid scaffold in nature, Δ(9)-THC double bond isomers remain poorly studied. The chemical scaffold of tetrahydrocannabinol can be assembled from the condensation of distinctly substituted phenols and monoterpenes. Here we explored a microwave-assisted one pot heterogeneous synthesis of Δ(3)-THC from orcinol (1a) and pulegone (2). Four Δ(3)-THC analogues and corresponding Δ(4a)-tetrahydroxanthenes (Δ(4a)-THXs) were synthesized regioselectively and showed differential binding affinities for CB1 and CB2 cannabinoid receptors. Here we report for the first time the CB1 receptor binding of Δ(3)-THC, revealing a more potent receptor binding affinity for the (S)-(-) isomer (hCB1Ki = 5 nM) compared to the (R)-(+) isomer (hCB1Ki = 29 nM). Like Δ(9)-THC, also Δ(3)-THC analogues are partial agonists at CB receptors as indicated by [(35)S]GTPγS binding assays. Interestingly, the THC structural isomers Δ(4a)-THXs showed selective binding and partial agonism at CB2 receptors, revealing a simple non-natural natural product-derived scaffold for novel CB2 ligands.
Resumo:
This paper presents a search for new particles in events with one lepton (electron or muon) and missing transverse momentum using 20.3 fb−1 of proton-proton collision data at TeX = 8 TeV recorded by the ATLAS experiment at the Large Hadron Collider. No significant excess beyond Standard Model expectations is observed. A W ′ with Sequential Standard Model couplings is excluded at the 95% confidence level for masses up to 3.24 TeV. Excited chiral bosons (W *) with equivalent coupling strengths are excluded for masses up to 3.21 TeV. In the framework of an effective field theory limits are also set on the dark matter-nucleon scattering cross-section as well as the mass scale M * of the unknown mediating interaction for dark matter pair production in association with a leptonically decaying W.
Resumo:
PURPOSE To investigate the influence of relative humidity and application time on bond strength to dentin of different classes of adhesive systems. MATERIALS AND METHODS A total of 360 extracted human molars were ground to mid-coronal dentin. The dentin specimens were treated with one of six adhesive systems (Syntac Classic, OptiBond FL, Clearfil SE Bond, AdheSE, Xeno Select, or Scotchbond Universal), and resin composite (Filtek Z250) was applied to the treated dentin surface under four experimental conditions (45% relative humidity/application time according to manufacturers' instructions; 45% relative humidity/reduced application time; 85% relative humidity/application time according to manufacturers' instructions; 85% relative humidity/reduced application time). After storage (37°C, 100% humidity, 24 h), shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by Kruskal-Wallis tests and Mann-Whitney U-tests with Bonferroni-Holm correction for multiple testing (level of significance: α = 0.05). RESULTS Increased relative humidity and reduced application time had no effect on SBS for Clearfil SE Bond and Scotchbond Universal (p = 1.00). For Syntac Classic, OptiBond FL, AdheSE, and Xeno Select there was no effect on SBS of reduced application time of the adhesive system (p ≥ 0.403). However, increased relative humidity significantly reduced SBS for Syntac Classic, OptiBond FL, and Xeno Select irrespective of application time (p ≤ 0.003), whereas for AdheSE, increased relative humidity significantly reduced SBS at recommended application time only (p = 0.002). CONCLUSION Generally, increased relative humidity had a detrimental effect on SBS to dentin, but reduced application time had no effect.
Resumo:
Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R2 improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae.
Resumo:
Oscillations between high and low values of the membrane potential (UP and DOWN states respectively) are an ubiquitous feature of cortical neurons during slow wave sleep and anesthesia. Nevertheless, a surprisingly small number of quantitative studies have been conducted only that deal with this phenomenon’s implications for computation. Here we present a novel theory that explains on a detailed mathematical level the computational benefits of UP states. The theory is based on random sampling by means of interspike intervals (ISIs) of the exponential integrate and fire (EIF) model neuron, such that each spike is considered a sample, whose analog value corresponds to the spike’s preceding ISI. As we show, the EIF’s exponential sodium current, that kicks in when balancing a noisy membrane potential around values close to the firing threshold, leads to a particularly simple, approximative relationship between the neuron’s ISI distribution and input current. Approximation quality depends on the frequency spectrum of the current and is improved upon increasing the voltage baseline towards threshold. Thus, the conceptually simpler leaky integrate and fire neuron that is missing such an additional current boost performs consistently worse than the EIF and does not improve when voltage baseline is increased. For the EIF in contrast, the presented mechanism is particularly effective in the high-conductance regime, which is a hallmark feature of UP-states. Our theoretical results are confirmed by accompanying simulations, which were conducted for input currents of varying spectral composition. Moreover, we provide analytical estimations of the range of ISI distributions the EIF neuron can sample from at a given approximation level. Such samples may be considered by any algorithmic procedure that is based on random sampling, such as Markov Chain Monte Carlo or message-passing methods. Finally, we explain how spike-based random sampling relates to existing computational theories about UP states during slow wave sleep and present possible extensions of the model in the context of spike-frequency adaptation.
Resumo:
AIM To assess the long-term success of maxillary fixed retainers, investigate their effect on gingival health, and analyse the survival rate after a mean period of 7 years (minimum 5 years) in retention. SUBJECTS AND METHODS Forty one subjects were included in the study A clinical examination of the upper canine to canine region including gingival index (GI), plaque index, probing depth, and bleeding on probing (BOP) was performed. Intraoral photographs and dental impressions were taken and irregularity index was determined and compared to the values of the immediate post-therapeutic values; failures of retainers were also recorded and analysed. RESULTS The mean observed retention time was 7 years and 5 months. Irregularity index: Changes occurring during retention were statistically different between the lateral incisors bonded to retainers and the canines not bonded to retainers. Only six patients showed changes in irregularity index of the lateral incisors in spite of a retainer in place. Periodontal health: The median value of the GI for all teeth bonded to upper retainers was 1.10 and the median value of the plaque index (PI) was 1.14. PI was not a significant predictor of GI. The overall BOP of the bonded teeth to the retainer for each participant was 22.3 per cent. Failure rate: Twenty-eight out of 41 patients experienced no failure of the upper bonded retainer (68.3 per cent). Detachments were the most frequent incidents. CONCLUSION Although plaque accumulation might be increased in patients with already poor oral hygiene, maxillary bonded retainers caused no significant negative effects on the periodontal health.
Resumo:
High-pressure powder X-ray diffraction is a fundamental technique for investigating structural responses to externally applied force. Synchrotron sources and two-dimensional detectors are required. In contrast to this conventional setup, high-resolution beamlines equipped with one-dimensional detectors could offer much better resolved peaks but cannot deliver accurate structure factors because they only sample a small portion of the Debye rings, which are usually inhomogeneous and spotty because of the small amount of sample. In this study, a simple method to overcome this problem is presented and successfully applied to solving the structure of an L-serine polymorph from powder data. A comparison of the obtained high-resolution high-pressure data with conventional data shows that this technique, providing up to ten times better angular resolution, can be of advantage for indexing, for lattice parameter refinement, and even for structure refinement and solution in special cases.
Resumo:
Space debris in geostationary orbits may be detected with optical telescopes when the objects are illuminated by the Sun. The advantage compared to Radar can be found in the illumination: radar illuminates the objects and thus the detection sensitivity depletest proportional to the fourth power of the d istance. The German Space Operation Center, GSOC, together with the Astronomical Institute of the University of Bern, AIUB, are setting up a telescope system called SMARTnet to demonstrate the capability of performing geostationary surveillance. Such a telescope system will consist of two telescopes on one mount: a smaller telescope with an aperture of 20cm will serve for fast survey while the larger one, a telescope with an aperture of 50cm, will be used for follow-up observations. The telescopes will be operated by GSOC from Oberpfaffenhofen by the internal monitoring and control system called SMARTnetMAC. The observation plan will be generated by MARTnetPlanning seven days in advance by applying an optimized planning scheduler, taking into account fault time like cloudy nights, priority of objects etc. From each picture taken, stars will be identified and everything not being a star is treated as a possible object. If the same object can be identified on multiple pictures within a short time span, the trace is called a tracklet. In the next step, several tracklets will be correlated to identify individual objects, ephemeris data for these objects are generated and catalogued . This will allow for services like collision avoidance to ensure safe operations for GSOC’s satellites. The complete data processing chain is handled by BACARDI, the backbone catalogue of relational debris information and is presented as a poster.
Resumo:
BACKGROUND Current reporting guidelines do not call for standardised declaration of follow-up completeness, although study validity depends on the representativeness of measured outcomes. The Follow-Up Index (FUI) describes follow-up completeness at a given study end date as ratio between the investigated and the potential follow-up period. The association between FUI and the accuracy of survival-estimates was investigated. METHODS FUI and Kaplan-Meier estimates were calculated twice for 1207 consecutive patients undergoing aortic repair during an 11-year period: in a scenario A the population's clinical routine follow-up data (available from a prospective registry) was analysed conventionally. For the control scenario B, an independent survey was completed at the predefined study end. To determine the relation between FUI and the accuracy of study findings, discrepancies between scenarios regarding FUI, follow-up duration and cumulative survival-estimates were evaluated using multivariate analyses. RESULTS Scenario A noted 89 deaths (7.4%) during a mean considered follow-up of 30±28months. Scenario B, although analysing the same study period, detected 304 deaths (25.2%, P<0.001) as it scrutinized the complete follow-up period (49±32months). FUI (0.57±0.35 versus 1.00±0, P<0.001) and cumulative survival estimates (78.7% versus 50.7%, P<0.001) differed significantly between scenarios, suggesting that incomplete follow-up information led to underestimation of mortality. Degree of follow-up completeness (i.e. FUI-quartiles and FUI-intervals) correlated directly with accuracy of study findings: underestimation of long-term mortality increased almost linearly by 30% with every 0.1 drop in FUI (adjusted HR 1.30; 95%-CI 1.24;1.36, P<0.001). CONCLUSION Follow-up completeness is a pre-requisite for reliable outcome assessment and should be declared systematically. FUI represents a simple measure suited as reporting standard. Evidence lacking such information must be challenged as potentially flawed by selection bias.
Resumo:
For preventing erosive wear in dentine, coating with adhesives has been suggested as an alternative to fluoridation. However, clinical studies have revealed limited efficacy. As there is first evidence that Sn(2+) increases bond strength of the adhesive Clearfil SE (Kuraray), the aim of the present study was to investigate whether pre-treatment with different Sn(2+)/F(-) solutions improves the durability of Clearfil SE coatings. Dentine samples (eight groups, n=16/group) were freed of smear layer (0.5% citric acid, 10 s), treated (15 s) either with no solution (control), aminefluoride (AmF, 500 ppm F(-), pH 4.5), SnCl2 (800/1600 ppm Sn(2+); pH 1.5), SnCl2/AmF (500 ppm F(-), 800 ppm Sn(2+), pH 1.5/3.0/4.5), or Elmex Erosion Protection Rinse (EP, 500 ppm F-, 800 ppm Sn(2+), pH 4.5; GABA International), then rinsed with water (15 s) and individually covered with Clearfil SE. Subsequently the specimens were subjected to an erosion/abrasion protocol consisting of 1320 cycles of immersion in 0.5% citric acid (5 °C/55 °C; 2 min) and automated brushing (15 s, 200 g, NaF-toothpaste, RDA 80). As the coatings proved stable up to 1320 cycles, 60 modified cycles (brushing time 30 min/cycle) were added. Wear was measured profilometrically. After SnCl2/AmF, pH 4.5 or EP pre-treatment all except one coating survived. In the other groups, almost all coatings were lost and there was no significant difference to the control group. Pre-treatment with a Sn(2+)/F(-) solution at pH 4.5 seems able to improve the durability of adhesive coatings, rendering these an attractive option in preventing erosive wear in dentine.
Resumo:
OBJECTIVE To evaluate use of a surgical technique commonly used in humans for treatment of cervical spondylotic myelopathy (CSM) in dogs. DESIGN Prospective case series. ANIMALS Dogs with CSM (n=10). METHODS Dogs weighing >30 kg that had CSM at 1 vertebral articulation were eligible for inclusion. Dogs had vertebral column distraction/fusion performed using a cortical ring allograft, cancellous autograft, and a spinal locking plate. Dogs were evaluated temporally by repeat neurological examinations and by client perception of postsurgical outcome, determined by telephone interview. RESULTS Nine dogs survived the immediate postoperative period. Seven of 8 dogs had moderate to complete improvement without recurrence (mean follow-up, 2.48 years). The most common postsurgical complications were screw loosening (n=4) and plate shifting (2), neither of which required surgical revision. One dog had pseudoarthrosis that may have negatively impacted outcome. CONCLUSION Treatment of single level CSM in dogs with ring allograft and a spinal locking plate system may lead to successful outcomes. The major problems encountered with included cost of the implants and adjusting the system designed for humans to fit the vertebral column of a dog. CLINICAL RELEVANCE For dogs with CSM at a single level, the use of a spinal locking plate in combination with a cortical ring allograft can be an effective surgical treatment. Costs of the implants as well as anatomic differences in dogs make this type of surgery less appealing.
Resumo:
Purpose To determine renal oxygenation changes associated with uninephrectomy and transplantation in both native donor kidneys and transplanted kidneys by using blood oxygenation level-dependent (BOLD) MR imaging. Materials and Methods The study protocol was approved by the local ethics committee. Thirteen healthy kidney donors and their corresponding recipients underwent kidney BOLD MR imaging with a 3-T imager. Written informed consent was obtained from each subject. BOLD MR imaging was performed in donors before uninephrectomy and in donors and recipients 8 days, 3 months, and 12 months after transplantation. R2* values, which are inversely related to tissue partial pressure of oxygen, were determined in the cortex and medulla. Longitudinal R2* changes were statistically analyzed by using repeated measures one-way analysis of variance with post hoc pair-wise comparisons. Results R2* values in the remaining kidneys significantly decreased early after uninephrectomy in both the medulla and cortex (P < .003), from 28.9 sec(-1) ± 2.3 to 26.4 sec(-1) ± 2.5 in the medulla and from 18.3 sec(-1) ± 1.5 to 16.3 sec(-1) ± 1.0 in the cortex, indicating increased oxygen content. In donors, R2* remained significantly decreased in both the medulla and cortex at 3 (P < .01) and 12 (P < .01) months. In transplanted kidneys, R2* remained stable during the first year after transplantation, with no significant change. Among donors, cortical R2* was found to be negatively correlated with estimated glomerular filtration rate (R = -0.47, P < .001). Conclusion The results suggest that BOLD MR imaging may potentially be used to monitor renal functional changes in both remaining and corresponding transplanted kidneys. (©) RSNA, 2016.