868 resultados para Obnoxious facility location
Resumo:
The aim of this work is to provide a precise and accurate measurement of the 238U(n,gamma) reaction cross-section. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behaviour of the reactor core. In particular, fast neutron reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region inconsistencies between the existing measurements are present up to 15%, and the most recent evaluations disagree each other. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross-section of 238U should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were scheduled within the ANDES project within the 7th Framework Project of the European Commission. The results of one of the 238U(n,gamma) measurement performed at the n_TOF CERN facility are presented in this work, carried out with a detection system constituted of two liquid scintillators. The very accurate cross section from this work is compared with the results obtained from the other measurement performed at the n_TOF facility, which exploit a different and complementary detection technique. The excellent agreement between the two data-sets points out that they can contribute to the reduction of the cross section uncertainty down to the required 1-3%.
Resumo:
The availability of a high-intensity antiproton beam with momentum up to 15,GeV/c at the future FAIR will open a unique opportunity to investigate wide areas of nuclear physics with the $overline{P}$ANDA (anti{$overline{P}$}roton ANnihilations at DArmstadt) detector. Part of these investigations concern the Electromagnetic Form Factors of the proton in the time-like region and the study of the Transition Distribution Amplitudes, for which feasibility studies have been performed in this Thesis. rnMoreover, simulations to study the efficiency and the energy resolution of the backward endcap of the electromagnetic calorimeter of $overline{P}$ANDA are presented. This detector is crucial especially for the reconstruction of processes like $bar pprightarrow e^+ e^- pi^0$, investigated in this work. Different arrangements of dead material were studied. The results show that both, the efficiency and the energy resolution of the backward endcap of the electromagnetic calorimeter fullfill the requirements for the detection of backward particles, and that this detector is necessary for the reconstruction of the channels of interest. rnrnThe study of the annihilation channel $bar pprightarrow e^+ e^-$ will improve the knowledge of the Electromagnetic Form Factors in the time-like region, and will help to understand their connection with the Electromagnetic Form Factors in the space-like region. In this Thesis the feasibility of a measurement of the $bar pprightarrow e^+ e^-$ cross section with $overline{P}$ANDA is studied using Monte-Carlo simulations. The major background channel $bar pprightarrow pi^+ pi^-$ is taken into account. The results show a $10^9$ background suppression factor, which assure a sufficiently clean signal with less than 0.1% background contamination. The signal can be measured with an efficiency greater than 30% up to $s=14$,(GeV/c)$^2$. The Electromagnetic Form Factors are extracted from the reconstructed signal and corrected angular distribution. Above this $s$ limit, the low cross section will not allow the direct extraction of the Electromagnetic Form Factors. However, the total cross section can still be measured and an extraction of the Electromagnetic Form Factors is possible considering certain assumptions on the ratio between the electric and magnetic contributions.rnrnThe Transition Distribution Amplitudes are new non-perturbative objects describing the transition between a baryon and a meson. They are accessible in hard exclusive processes like $bar pprightarrow e^+ e^- pi^0$. The study of this process with $overline{P}$ANDA will test the Transition Distribution Amplitudes approach. This work includes a feasibility study for measuring this channel with $overline{P}$ANDA. The main background reaction is here $bar pprightarrow pi^+ pi^- pi^0$. A background suppression factor of $10^8$ has been achieved while keeping a signal efficiency above 20%.rnrnrnPart of this work has been published in the European Physics Journal A 44, 373-384 (2010).rn
Resumo:
La tesi consiste nel realizzare una infrastruttura che mantenga il modello tipico dello Spatial Computing e coniughi al meglio le tecnologie location-based come GPS, NFC e BLE, per permettere ai moderni smart-devices Android di cooperare e auto-organizzarsi al fine di compiere un certo task definito a livello applicativo.
Resumo:
un' applicazione in grado di memorizzare e mappare tutti i punti dove è possibile collegarsi, in modo gratuito, ad internet usando il nostro Smartphone. Per tenere traccia di questi punti si utilizza un meccanismo in grado di determinare la posizione geografica del dispositivo mediante il quale l’utente si connette alla rete. Inoltre è possibile la condivisione di tutti i punti registrati su un database online per rendere pubbliche le proprie registrazioni.
Resumo:
To assess retrospectively the frequency and location of mandibular lingual foramina and their bony canals with limited cone-beam computed tomography.
Resumo:
Perineurioma is an uncommon, mostly benign, spindle-cell tumor of peripheral nerve sheath origin with a predilection for the soft tissues. Although increasing awareness points to the sites of involvement by perineurioma possibly being as ubiquitous as those frequented by schwannian tumors, only one intracerebral example has been described to date. We report on a surgically resected perineurioma of the falx cerebri in an 86-year-old woman. Preoperative imaging showed an enhancing extraaxial mass of 6 cm × 5.7 cm × 3.7 cm. Histologically, the tumor consisted of a proliferation of spindle cells interwoven by a lattice of basal lamina. Alongside a prevailing soft tissue perineurioma pattern, sclerosing and reticular areas were seen as well. Tumor cells coexpressed EMA and GLUT-1, and a minority immunoreacted for smooth muscle actin. Pericellular basal lamina was decorated with collagen type IV. No staining for S100 protein was detected. Mitotic activity was virtually absent, and the MIB1 labeling index averaged 2%. Ultrastructural examination revealed abundant pinocytotic vesicles within and conspicuous tight junctions between slender cytoplasmic processes which, in turn, were encased by discontinuous basal lamina. FISH analysis confirmed loss of at least part of one chromosome 22q. This observation calls attention to perineurioma as a novel item in the repertoire of low-grade meningial spindle cell neoplasms, in the differential diagnostic context of which it is apt to being misconstrued as either meningioma, solitary fibrous tumor, or neurofibroma. Confusion with the latter bears the risk of overgrading innocuous features of perineurioma as criteria for malignancy.
Resumo:
At the research reactor Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) a new Prompt Gamma-ray Activation Analysis (PGAA) facility was installed. The instrument was originally built and operating at the spallation source at the Paul Scherrer Institute in Switzerland. After a careful re-design in 2004–2006, the new PGAA instrument was ready for operation at FRM II. In this paper the main characteristics and the current operation conditions of the facility are described. The neutron flux at the sample position can reach up 6.07×1010 [cm−2 s−1], thus the optimisation of some parameters, e.g. the beam background, was necessary in order to achieve a satisfactory analytical sensitivity for routine measurements. Once the optimal conditions were reached, detection limits and sensitivities for some elements, like for example H, B, C, Si, or Pb, were calculated and compared with other PGAA facilities. A standard reference material was also measured in order to show the reliability of the analysis under different conditions at this instrument.