922 resultados para Non-invasive sampling
Resumo:
This paper deals with the joint economic design of x̄ and R charts when the occurrence times of assignable causes follow Weibull distributions with increasing failure rates. The variable quality characteristic is assumed to be normally distributed and the process is subject to two independent assignable causes (such as tool wear-out, overheating, or vibration). One cause changes the process mean and the other changes the process variance. However, the occurrence of one kind of assignable cause does not preclude the occurrence of the other. A cost model is developed and a non-uniform sampling interval scheme is adopted. A two-step search procedure is employed to determine the optimum design parameters. Finally, a sensitivity analysis of the model is conducted, and the cost savings associated with the use of non-uniform sampling intervals instead of constant sampling intervals are evaluated.
Resumo:
The aim of this study was to test the hypothesis that protein-calorie undernutrition decreases myocardial contractility jeopardizing ventricular function, and that ventricular dysfunction can be detected noninvasively. Five-month-old male Wistar-Kyoto rats were fed with regular rat chow ad libitum for 90 days (Control group, n = 14). A second group of rats received 50% of the amount of diet consumed by de control group (Food restricted group, n = 14). Global LV systolic function was evaluated in vivo, noninvasively, by transthoracic echocardiogram. After echocardiographic study, myocardial contractility was assessed in vitro in the isovolumetrically beating isolated heart in eight animals from each group (Langendorff preparation). The in vivo LV fractional shortening showed that food restriction depressed LV systolic function (p < 0.05). Myocardial contractility was impaired as assessed by the maximal rate of rise of LV pressure (+dP/dt), and developed pressure at diastolic pressure of 25 mmHg (p < 0.05). Furthermore, food restriction induced eccentric ventricular remodeling, and reduced myocardial elasticity and LV compliance (p < 0.05). In conclusion, food restriction causes systolic dysfunction probably due to myocardial contractility impairment and reduction of myocardial elasticity. © 2002 Elsevier B.V. All rights reserved.
Resumo:
Oral administration with solid dosage forms is a common route in the drug therapy widely used. The drug release by the disintegration process occurs in several gastrointestinal tract (GIT) regions. AC Biosusceptometry (ACB) was originally proposal to characterize the disintegration process of tablets in vitro and in the human stomach, through changes in magnetic signals. The aim of this work was to employ a multisensor ACB system to monitoring magnetic tablets and capsules in the human GIT and to obtain the magnetic images of the disintegration process. The ACB showed accuracy to quantify the gastric residence time, the intestinal transit time and the magnetic images allowed to visualize the disintegration of magnetic formulations in the GIT. The ACB is a non-invasive, radiation free technique, completely safe and harmless to the volunteers and had demonstrated potential to evaluate pharmaceutical dosage forms in the human gastrointestinal tract. © 2005 IEEE.
Resumo:
The aim of this study was to determine whether there are differences in the attitudes of Dentistry School Professors from two universities, one private and one public concerning HIV-positive patients or HIV-positive health care professionals. A questionnaire Was handled to all profession at the Araçatuba Dental School of São Paulo State University - FOA-UNESP (public) and Lins Dental School of the Piracicaba Methodist University - FOL-UNIMEP (private). When asked if they would be willing to be treated by an HIV-infected health care professional, 38.9% of the 77 professors at FOA-UNESP replied that they would accept only non-invasive treatments and 13% would not accept any kind of treatment; the same applied to 42.4% and 15.2% of the 33 FOL-UNIMEP professors. Among the 54 professors at FOA-UNESP and 27 at FOL-UNIMEP providing clinical service, only 31.5% and 18.5% stated that they treat HIV-infected persons like any other patient. The results were very similar in both schools. Although they reported that they taught their students not to act in a discriminatory manner towards HIV-positive patient the professors themselves showed prejudice towards infected patients and professionals. Consequently, this topic trust be further debated in the academic milieu.
Resumo:
AIM: The aim of this report is to describe the restorative treatment of an 18-year-old patient diagnosed with autosomal recessive hypocalcified-hypoplastic amelogenesis imperfecta (AI). BACKGROUND: Esthetic and functional rehabilitations in AI cases are challenging and should consider individual aspects, such as age, socioeconomic status, AI type, and intraoral condition. REPORT: AI was diagnosed in an 18-year-old patient. SUMMARY: Considering the short length of crowns and roots, patient life expectancy, minimal invasiveness, amount of treatment time required, and lower costs, oral rehabilitation with overdentures provided an adequate functional and esthetic rehabilitation of the patient. CLINICAL SIGNIFICANCE: This report demonstrated overdentures to be a viable, relatively inexpensive, and non-invasive treatment choice of a patient with AI with concerns about treatment longevity, invasiveness, cost, esthetics, and long-term maintenance.
Resumo:
BACKGROUND AND OBJECTIVES: Due to the high incidence of technical and neurological complications, continuous spinal blocks were not performed for several years. With the advent of intermediate catheters the technique has been used more often and gaining acceptance among anesthesiologists. The objective of this report was to demonstrate the usefulness of the technique as a viable alternative for medium and major size surgeries. CASE REPORT: This is a 58 years old female patient, weighing 62 kg, physical status ASA I, with a history of migraines, low back pain, and prior surgeries under spinal block without intercurrence. The patient was scheduled for exploratory laparotomy for a probable pelvic tumor. After venoclysis with an 18G catheter, monitoring with cardioscope, non-invasive blood pressure and pulse oximetry was instituted; she was sedated with 2 mg of midazolam and 100 μg of fentanyl, and placed in left lateral decubitus. The patient underwent continuous spinal block through the median approach in L 3-L 4; 9 mg of 0.5% hyperbaric bupivacaine and 120 μ g of morphine sulfate were administered. Inspection of the abdominal cavity revealed a gastric stromal tumor that required an increase in the incision for a partial gastrectomy. A small dose of hyperbaric solution was required for the entire procedure, which was associated with complete hemodynamic stability. Postoperative admission to the ICU was not necessary; the patient presented a good evolution without complaints and with a high degree of satisfaction. She was discharged from the hospital after 72 hours without intercurrence. CONCLUSIONS: Intermediate catheters used in continuous spinal blocks have shown the potential to turn it an attractive and useful technique in medium and large size surgeries and it can even be an effective alternative in the management of critical patients to whom hemodynamic repercussions can be harmful.
Resumo:
The aim of this study was to validate a non-invasive protocol to determine aerobic and anaerobic capacity of treadmill running rats. Thirteen male Wistar rats (90 days old) were submitted to 4 exercise tests, consisting of running at 25, 30, 35 and 40 m min-1, continuously until exhaustion. For the critical velocity (CV) and anaerobic running capacity (ARC) estimations, the hyperbolic curve (velocity versus time to exhaustion (tlim)) was linearized to V= CV+ARC/tlim, where the CV and ARC were linear and slope coefficients, respectively. In order to verify if the CV was the maximal aerobic intensity, the rats were submitted to the maximal lactate steady state test (MLSS) composed of three 25-minute tests of continuous running trials at 15, 20 and 25 m min-1, with blood collection every 5 minutes. The CV was obtained at 22.8±0.7 m min-1 and the ARC, at 26.80±2.77 m. The MLSS was observed at 20m min-1, with blood lactate 3.84 ± 0.31 mmol L-1. There was a progressive increase in lactate concentration at 25 m min-1. The CV and MLSS were different, but presented a high and significant correlation (r=0.81). These results indicate that the non-invasive protocol can be used for physical evaluation of aerobic running rats, but the ARC should still be further investigated.
Resumo:
Objective: This case-control study analyzed mass spectrometry fingerprinting patterns of culture media samples used for embryo culture to predict embryo implantation. Methods: The culture medium harvested after embryo transfer of 22 embryos from 13 patients was used for the experiments. After embryo transfer, the remaining culture media were collected and samples were split in positive (n=8) and negative (n=14) implantation groups according to implantation outcomes (100% or 0% of implantation). Samples were individually diluted and injected directly to the Electrospray ionization (ESI) MS coupled to a Quadrupole Time-of-flight MS (Q-ToF-MS).Ions relative intensities of each spectrum were considered. Data analysis was conducted in MatLab 7.0 version using Partial Least Squares - Discriminant Analysis toolbox. Results: There were 3027 observed ions at 100% and 0% implantation groups by ESI-Q-ToF-MS. The statistical model could categorize the samples in two clusters, based on their positive and negative implantation outcomes. Less intense ions present in the mass spectra with statistical significance have contributed to the major differences to group distinction. Conclusions: Positive and negative implantation embryos showed a specific biochemical pattern present in culture media, which could be detected as a fast, simple and non-invasive way. This biochemical profile could help the selection of the most viable embryo, improving single embryo transfer and thus eliminating the risk and undesirable outcomes of multiple pregnancies. © Todos os direitos reservados a SBRA - Sociedade Brasileira de Reprodução Assistida.
Resumo:
Neurocysticercosis (NCC) is an infection of the central nervous system (CNS) caused by the metacestode larval form of the parasite Taenia sp. Many factors can contribute to the endemic nature of cysticercosis. The inflammatory process that occurs in the tissue surrounding the parasite and/or distal from it can result from several associated mechanisms and may be disproportionate with the number of cysts. This discrepancy may lead to difficulty with the proper diagnosis in people from low endemic regions or regions that lack laboratory resources. In the CNS, the cysticerci have two basic forms, isolated cysts (Cysticercus cellulosae = CC) and racemose cysts (Cysticercus racemosus = CR), and may be meningeal, parenchymal, or ventricular or have a mixed location. The clinical manifestations are based on two fundamental syndromes that may occur in isolation or be associated: epilepsy and intracranial hypertension. They may be asymptomatic, symptomatic or fatal; have an acute, sub-acute or chronic picture; or may be in remission or exacerbated. The cerebrospinal fluid (CSF) may be normal, even in patients with viable cysticerci, until the patients begin to exhibit the classical syndrome of NCC in the CSF, or show changes in one or more routine analysed parameters. Computed tomography (CT) and magnetic resonance imaging (MRI) have allowed non-invasive diagnoses, but can lead to false negatives. Treatment is a highly controversial issue and is characterised by individualised therapy sessions. Two drugs are commonly used, praziquantel (PZQ) and albendazole (ABZ). The choice of anti-inflammatory drugs includes steroids and dextrochlorpheniramine (DCP). Hydrocephalus is a common secondary effect of NCC. Surgical cases of hydrocephalus must be submitted to ventricle-peritoneal shunt (VPS) immediately before cysticidal treatment, and surgical extirpation of the cyst may lead to an absence of the surrounding inflammatory process. The progression of NCC may be simple or complicated, have remission with or without treatment and may exhibit symptoms that can disappear for long periods of time or persist until death. Unknown, neglected and controversial aspects of NCC, such as the impaired fourth ventricle syndrome, the presence of chronic brain oedema and psychic complaints, in addition to the lack of detectable glucose in the CSF and re-infection are discussed. © 2011 Bentham Science Publishers.
Resumo:
Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.
Resumo:
AC Biosusceptometry (ACB) was previously employed towards recording gastrointestinal motility. Our data show a reliable and successful evaluation of gastrointestinal transit of liquid and solid meals in rats, considering the methods scarcity and number of experiments needed to endorsement of drugs and medicinal plants. ACB permits real time and simultaneous experiments using the same animal, preserving the physiological conditions employing both meals with simplicity and accuracy. © 2012 Quini et al.; licensee BioMed Central Ltd.
Resumo:
A hybrid magnetic instrumentation to detect a magnetic field from a permanent magnet, and to detect magnetic markers and tracers using alternating current biosusceptometry (ACB) is discussed. The instrument was used to in vitro evaluation of the esophageal transit time. The sensitivity between both magnetic methods was compared, showing sensitivity for in vivo applications. © 2013 Springer-Verlag.
Resumo:
An important tool for the heart disease diagnosis is the analysis of electrocardiogram (ECG) signals, since the non-invasive nature and simplicity of the ECG exam. According to the application, ECG data analysis consists of steps such as preprocessing, segmentation, feature extraction and classification aiming to detect cardiac arrhythmias (i.e.; cardiac rhythm abnormalities). Aiming to made a fast and accurate cardiac arrhythmia signal classification process, we apply and analyze a recent and robust supervised graph-based pattern recognition technique, the optimum-path forest (OPF) classifier. To the best of our knowledge, it is the first time that OPF classifier is used to the ECG heartbeat signal classification task. We then compare the performance (in terms of training and testing time, accuracy, specificity, and sensitivity) of the OPF classifier to the ones of other three well-known expert system classifiers, i.e.; support vector machine (SVM), Bayesian and multilayer artificial neural network (MLP), using features extracted from six main approaches considered in literature for ECG arrhythmia analysis. In our experiments, we use the MIT-BIH Arrhythmia Database and the evaluation protocol recommended by The Association for the Advancement of Medical Instrumentation. A discussion on the obtained results shows that OPF classifier presents a robust performance, i.e.; there is no need for parameter setup, as well as a high accuracy at an extremely low computational cost. Moreover, in average, the OPF classifier yielded greater performance than the MLP and SVM classifiers in terms of classification time and accuracy, and to produce quite similar performance to the Bayesian classifier, showing to be a promising technique for ECG signal analysis. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)