918 resultados para NIRF imaging
Resumo:
Abstract Low back pain is often managed at all levels of healthcare. In general, diagnostic investigation begins with radiography of the lumbar spine. In addition to the most common findings, radiologists can identify increased density of a vertebral body, referred to as ivory vertebra. The objective of this study was to describe the main diseases that can present with this radiologic sign, such as Hodgkin lymphoma, Paget's disease, metastatic prostate cancer, breast cancer, and osteomyelitis. It is extremely important that radiologists be aware of this finding in order to inform the requesting physician of the possible etiologies, given that it can be the initial radiologic presentation for these diseases.
Resumo:
Congenital lung malformations are increasingly detected before birth. However, bronchial atresia is rarely identified in utero and not always recognized in neonates. There are two types of atresia: 1) proximal, located at the level of the mainstem or the proximal lobar bronchi, which is extremely rare and usually lethal during pregnancy, causing a tremendous volume increase of the distal involved lung with secondary hypoplasia of the normal lung, and 2) peripheral, located at the segmental/subsegmental bronchial level, which may present as an isolated lesion or as part of a complex congenital malformation. Prenatal findings are mostly nonspecific. Postnatal exams show overinflated lung areas and focal bronchial dilations. The typical fluid-filled bronchoceles are not always observed in neonates but develop progressively in the first months of life. This pictorial essay describes the spectrum of imaging findings of bronchial atresia in fetuses, neonates and infants.
Resumo:
We present a polarimetric-based optical encoder for image encryption and verification. A system for generating random polarized vector keys based on a Mach-Zehnder configuration combined with translucent liquid crystal displays in each path of the interferometer is developed. Polarization information of the encrypted signal is retrieved by taking advantage of the information provided by the Stokes parameters. Moreover, photon-counting model is used in the encryption process which provides data sparseness and nonlinear transformation to enhance security. An authorized user with access to the polarization keys and the optical design variables can retrieve and validate the photon-counting plain-text. Optical experimental results demonstrate the feasibility of the encryption method.
Resumo:
This paper proposes a pose-based algorithm to solve the full SLAM problem for an autonomous underwater vehicle (AUV), navigating in an unknown and possibly unstructured environment. The technique incorporate probabilistic scan matching with range scans gathered from a mechanical scanning imaging sonar (MSIS) and the robot dead-reckoning displacements estimated from a Doppler velocity log (DVL) and a motion reference unit (MRU). The proposed method utilizes two extended Kalman filters (EKF). The first, estimates the local path travelled by the robot while grabbing the scan as well as its uncertainty and provides position estimates for correcting the distortions that the vehicle motion produces in the acoustic images. The second is an augment state EKF that estimates and keeps the registered scans poses. The raw data from the sensors are processed and fused in-line. No priory structural information or initial pose are considered. The algorithm has been tested on an AUV guided along a 600 m path within a marina environment, showing the viability of the proposed approach
Resumo:
The knowledge on the optics of fogbows is scarce, and their polarization characteristics have never been measured to our knowledge. To fill this gap we measured the polarization features of 16 fogbows during the Beringia 2005 Arctic polar research expedition by imaging polarimetry in the red, green and blue spectral ranges. We present here the first polarization patterns of the fogbow. In the patterns of the degree of linear polarization p, fogbows and their supernumerary bows are best visible in the red spectral range due to the least dilution of fogbow light by light scattered in air. In the patterns of the angle of polarization α fogbows are practically not discernible because their α-pattern is the same as that of the sky: the direction of polarization is perpendicular to the plane of scattering and is parallel to the arc of the bow, independently of the wavelength. Fogbows and their supernumeraries were best seen in the patterns of the polarized radiance. In these patterns the angular distance δ between the peaks of the primary and the first supernumerary and the angular width σ of the primary bow were determined along different radii from the center of the bow. δ ranged between 6.08° and 13.41° , while σ changed from 5.25° to 19.47° . Certain fogbows were relatively homogeneous, meaning small variations of δ and σ along their bows. Other fogbows were heterogeneous, possessing quite variable δ- and σ-values along their bows. This variability could be a consequence of the characteristics of the high Arctic with open waters within the ice shield resulting in the spatiotemporal change of the droplet size within the fog
Resumo:
Somatization was described 4000 years ago but the pathophysiology of the, phenomenon is unknown. The aim of this investigation was to explore whether central nervous system (CNS) pathology is associated with severe somatization which was operationalized as somatization disorder (SD) and undifferentiated somatoform disorder. The study sample consisted of severely somatizing people who were included into the study after a multi-phase screening procedure in order to exclude psychiatric comorbidities and physical illnesses. Diagnosis of somatization disorder or undifferentiated sofatoform disorder were set according to Diagnostic and Statistical Manual of Mental Disorders 4th ed. (DSM-IV). The first study explored the regional cerebral metabolic rate of glucose (rCMRGlc) in severely somatizing females and found it to be reduced in several regions of the brain compared to healthy controls. The second study observed brain morphology with magnetic resonance imaging (MRI) based on the findings from the first study and showed enlarged caudate nuclei in somatizing women compared to healthy volunteers. The third study investigated temperament factors and brain metabolism, and their association with severe somatization. Low caudate and putamen metabolism, low novelty seeking as well as high harm avoidance were found to be associated with severe somatization in women, reduced caudate metabolism having the strongest association. The last study is a report of man with left-side gradient of multiple symptoms of unknown origin in the body. The examination revealed a hypermetabolic nucleus putamen on the contralateral side. All the main results reported in these four articles are original findings. The results suggest that CNS pathology is involved in the pathophysiology of severe somatization.
Resumo:
We study how the combination of long and short laser pulses can be used to induce torsion in an axially chiral biphenyl derivative (3,5-difluoro-3 ,5 -dibromo-4 -cyanobiphenyl). A long, with respect to the molecular rotational periods, elliptically polarized laser pulse produces 3D alignment of the molecules, and a linearly polarized short pulse initiates torsion about the stereogenic axis. The torsional motion is monitored in real-time by measuring the dihedral angle using femtosecond time-resolved Coulomb explosion imaging. Within the first 4 picoseconds (ps), torsion occurs with a period of 1.25 ps and an amplitude of 3◦ in excellent agreement with theoretical calculations. At larger times, the quantum states of the molecules describing the torsional motion dephase and an almost isotropic distribution of the dihedral angle is measured.We demonstrate an original application of covariance analysis of two-dimensional ion images to reveal strong correlations between specific ejected ionic fragments from Coulomb explosion. This technique strengthens our interpretation of the experimental data
Resumo:
The starting point of our investigation was the longstanding notion that bilingual individuals need effective mechanisms to prevent interference from one language while processing material in the other (e.g. Penfield and Roberts, 1959). To demonstrate how the prevention of interference is implemented in the brain we employed event-related brain potentials (ERPs; see Munte, Urbach, ¨ Duzel and Kutas, 2000, for an introductory review) ¨ and functional magnetic resonance imaging (fMRI) techniques, thus pursuing a combined temporal and spatial imaging approach. In contrast to previous investigations using neuroimaging techniques in bilinguals, which had been mainly concerned with the localization of the primary and secondary languages (e.g. Perani, Paulesu, Galles, Dupoux, Dehaene, Bettinardi, Cappa, Fazio and Mehler, 1998; Chee, Caplan, Soon, Sriram, Tan, Thiel and Weekes, 1999), our study addressed the dynamic aspects of bilingual language processing.
Resumo:
Ewing sarcoma or primitive neuroectodermal tumor (PNET) of bone is the second most common pediatric malignant bone tumor. The median age at diagnosis is 15 years and there is a male predilection of 1.5/1. The authors present the case of a 14-year-old boy with Ewing sarcoma situated on the left ninth rib which was being investigated for respiratory tract infection. Pleurisy is the most common misdiagnosis. Our case illustrates the importance of recognizing exceptional features when interpreting FDG PET or scintigraphy to prevent the misinterpretation of metastases as other etiologies, such as infection.
Resumo:
Atherosclerosis is a vascular inflammatory disease causing coronary artery disease, myocardial infarct and stroke, the leading causes of death in Finland and in many other countries. The development of atherosclerotic plaques starts already in childhood and is an ongoing process throughout life. Rupture of a plaque and the following occlusion of the vessel is the main reason for myocardial infarct and stroke, but despite extensive research, the prediction of rupture remains a major clinical problem. Inflammation is considered a key factor in the vulnerability of plaques to rupture. Measuring the inflammation in plaques non-invasively is one potential approach for identification of vulnerable plaques. The aim of this study was to evaluate tracers for positron emission tomography (PET) imaging of vascular inflammation. The studies were performed with a mouse model of atherosclerosis by using ex vivo biodistribution, autoradiography and in vivo PET and computed tomography (CT). Several tracers for inflammation activity were tested and compared with the morphology of the plaques. Inflammation in the atherosclerotic plaques was evaluated as expression of active macrophages. Systematic analysis revealed that the uptake of 18F-FDG and 11C-choline, tracers for metabolic activity in inflammatory cells, was more prominent in the atherosclerotic plaques than in the surrounding healthy vessel wall. The tracer for αvβ3 integrin, 18Fgalacto- RGD, was also found to have high potential for imaging inflammation in the plaques. While 11C-PK11195, a tracer targeted to receptors in active macrophages, was shown to accumulate in active plaques, the target-to-background ratio was not found to be ideal for in vivo imaging purposes. In conclusion, tracers for the imaging of inflammation in atherosclerotic plaques can be tested in experimental pre-clinical settings to select potential imaging agents for further clinical testing. 18F-FDG, 18F-galacto-RGD and 11C-choline choline have good properties, and further studies to clarify their applicability for atherosclerosis imaging in humans are warranted.
Resumo:
We develop a method for obtaining 3D polarimetric integral images from elemental images recorded in low light illumination conditions. Since photon-counting images are very sparse, calculation of the Stokes parameters and the degree of polarization should be handled carefully. In our approach, polarimetric 3D integral images are generated using the Maximum Likelihood Estimation and subsequently reconstructed by means of a Total Variation Denoising filter. In this way, polarimetric results are comparable to those obtained in conventional illumination conditions. We also show that polarimetric information retrieved from photon starved images can be used in 3D object recognition problems. To the best of our knowledge, this is the first report on 3D polarimetric photon counting integral imaging.
Resumo:
Dirt counting and dirt particle characterisation of pulp samples is an important part of quality control in pulp and paper production. The need for an automatic image analysis system to consider dirt particle characterisation in various pulp samples is also very critical. However, existent image analysis systems utilise a single threshold to segment the dirt particles in different pulp samples. This limits their precision. Based on evidence, designing an automatic image analysis system that could overcome this deficiency is very useful. In this study, the developed Niblack thresholding method is proposed. The method defines the threshold based on the number of segmented particles. In addition, the Kittler thresholding is utilised. Both of these thresholding methods can determine the dirt count of the different pulp samples accurately as compared to visual inspection and the Digital Optical Measuring and Analysis System (DOMAS). In addition, the minimum resolution needed for acquiring a scanner image is defined. By considering the variation in dirt particle features, the curl shows acceptable difference to discriminate the bark and the fibre bundles in different pulp samples. Three classifiers, called k-Nearest Neighbour, Linear Discriminant Analysis and Multi-layer Perceptron are utilised to categorize the dirt particles. Linear Discriminant Analysis and Multi-layer Perceptron are the most accurate in classifying the segmented dirt particles by the Kittler thresholding with morphological processing. The result shows that the dirt particles are successfully categorized for bark and for fibre bundles.
Resumo:
Coronary artery disease (CAD) is a chronic process that evolves over decades and may culminate in myocardial infarction (MI). While invasive coronary angiography (ICA) is still considered the gold standard of imaging CAD, non-invasive assessment of both the vascular anatomy and myocardial perfusion has become an intriguing alternative. In particular, computed tomography (CT) and positron emission tomography (PET) form an attractive combination for such studies. Increased radiation dose is, however, a concern. Our aim in the current thesis was to test novel CT and PET techniques alone and in hybrid setting in the detection and assessment of CAD in clinical patients. Along with diagnostic accuracy, methods for the reduction of the radiation dose was an important target. The study investigating the coronary arteries of patients with atrial fibrillation (AF) showed that CAD may be an important etiology of AF because a high prevalence of CAD was demonstrated within AF patients. In patients with suspected CAD, we demonstrated that a sequential, prospectively ECG-triggered CT technique was applicable to nearly 9/10 clinical patients and the radiation dose was over 60% lower than with spiral CT. To detect the functional significance of obstructive CAD, a novel software for perfusion quantification, CarimasTM, showed high reproducibility with 15O-labelled water in PET, supporting feasibility and good clinical accuracy. In a larger cohort of 107 patients with moderate 30-70% pre-test probability of CAD, hybrid PET/CT was shown to be a powerful diagnostic method in the assessment of CAD with diagnostic accuracy comparable to that of invasive angiography and fractional flow reserve (FFR) measurements. A hybrid study may be performed with a reasonable radiation dose in a vast majority of the cases, improving the performance of stand-alone PET and CT angiography, particularly when the absolute quantification of the perfusion is employed. These results can be applied into clinical practice and will be useful for daily clinical diagnosis of CAD.
Resumo:
Studies on 68Ga-Based Agents for PET Imaging of Cancer and Inflammation Positron emission tomography (PET) is based on the use of radiolabeled agents and facilitates in vivo imaging of biological processes, such as cancer. Because the detection of cancer is demanding and is often obscured by inflammation, there is a demand for better PET imaging agents. The aim was to preliminarily evaluate new PET agents for imaging cancer and inflammation using experimental models. 68Ga-chloride and peptides, 68Ga-labeled through 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), targeting matrix metalloproteinase-9 (MMP-9) were tested for tumor imaging. In addition, a 68Ga-DOTA-conjugated peptide targeting vascular adhesion protein-1 (VAP-1), was tested for inflammation imaging. The 68Ga-based imaging agents described here showed potential features by passing the essential in vitro tests, proceeding further to preclinical in vivo evaluation and being able to visualize the target. The target uptake and target-to-background ratios of 68Ga-based agents were, however, not optimal. 68Ga-chloride showed slow clearance caused by its binding to blood transferrin. In the case of 68Ga-DOTA-peptides low in vivo stability and/or low lipophilicity led to too rapid blood clearance and urinary excretion. The properties of 68Ga-labeled peptides are modifiable, as shown with matrix metalloproteinase-9 targeting ligands. In the conclusion of this PhD thesis, 68Ga-based agents for PET imaging of cancer and inflammation could be applied in the development of drugs, earlier diagnostics and following-up of the efficacy of therapies.