990 resultados para NETTRA-G1.
Resumo:
This study investigated the flexural strength of eight fiber posts (one carbon fiber, one carbon/quartz fiber, one opaque quartz fiber, two translucent quartz fiber, and three glass fiber posts). Eighty fiber posts were used and divided into eight groups (n = 10): G1: C-POST (Bisco); G2: ÆSTHETI-POST (Bisco); G3: ÆSTHETI-PLUS (Bisco); G4: LIGHT-POST (Bisco); G5: D.T. LIGHT-POST (Bisco); G6: PARAPOST WHITE (Coltene); G7: FIBERKOR (Pentron); G8: REFORPOST (Angelus). All of the samples were tested using the three-point bending test. The averages obtained were submitted to the ANOVA and to Tukey's test (p < 0.05). The mean values (MPa) of the groups ÆSTHETI-POST - carbon/ quartz fiber post (Bisco) and ÆSTHETI-PLUS - quartz fiber post (Bisco) were statistically similar and higher than the mean values of the other groups. The mean values of the groups C-POST - carbon fiber post (Bisco), LIGHT-POST - translucent quartz fiber post (Bisco), D.T. LIGHT-POST - double tapered translucent quartz fiber post (Bisco), PARAPOST WHITE - glass fiber post (Coltene) and FIBREKOR - glass fiber post (Pentron) were similar and higher than the group REFORPOST - glass fiber post (Angelus). Copyright © 2005 by the American Association of Endodontists.
Resumo:
Purpose: This study tested the null hypothesis that different treatments of saliva-contaminated substrate would not affect microgap formation at the dentin walls of bonded restorations. Materials and Methods: Forty freshly extracted human molars received standardized Class V preparations on buccal and lingual surfaces. The specimens were assigned to four experimental groups (n = 20): [G1] no contamination (control group), [G2] saliva contamination (10 s) after etching followed by 5 s air stream; [G3] saliva contamination after etching and rinsed for 10 s; and [G4] re-etching for 10 s after saliva contamination. All specimens were restored with a one-bottle adhesive (Single Bond, 3M ESPE) and microhybrid composite resin (Filtek Z250, 3M ESPE) according to the manufacturer's instructions. The specimens were thermocycled, sectioned through the center of the restoration, and then processed for SEM. Microgaps were measured at the axial wall at 1500X magnification. The data were submitted to Kruskal-Wallis nonparametric statistical analysis at p < 0.05. Results: The data revealed that different groups resulted in a statistically significant difference (p < 0.01) in gap formation. Air drying [G2] and rinsing [G3] the saliva-contaminated dentin resulted in similar microgap values (p > 0.05). However, re-etching the dentin after saliva contamination [G4] increased microgap formation (p < 0.05) when compared with the groups G1 and G2. Although air drying and rinsing produced results comparable to noncontaminated dentin, the presence of microgaps was not completely eliminated. Conclusion: Contaminated saliva did not prevent hybrid layer formation; however, it did reduce the adaptation of the restorative material to bonded surfaces.
Resumo:
Since the use of air abrasion has grown in pediatric dentistry, the aim of this study was to evaluate, by means of shear bond strength testing, the need to use the total etching technique or self-etching primers on dentin of primary teeth after air abrasion. Twenty-five exfoliated primary molars had their occlusal dentin exposed by trimming and polishing. Specimens were treated by: Air abrasion + Scotchbond MultiPurpose adhesive (G1); 37% phosphoric acid + Scotchbond MP adhesive (G2); Clearfil SE (G3); Air abrasion ( 37% phosphoric acid + Scotchbond MP adhesive (G4); Air abrasion + Clearfil SE (G5). On the treated surface, a cylinder of 2 mm by 6 mm was made using a composite resin (Z100). Duncan's test showed that: (G2 = G3 = G5) > (G1 = G4). The use of a selfetching primer on air abraded dentin is recommended to obtain higher bond strengths.
Resumo:
Purpose: To evaluate the pullout strength of a glass fiber-reinforced composite post (glass FRC) cemented with three different adhesive systems and one resin cement. The null hypothesis was that pullout strengths yielded by the adhesive systems are similar. Materials and Methods: Thirty bovine teeth were selected. The size of the specimens was standardized at 16 mm by sectioning off the coronal portion and part of the root. The specimens were divided into three groups, according to the adhesive system, which were applied following the manufacturers' instructions: G1, ScotchBond Multi-Purpose Plus; G2, Single Bond; G3, Tyrian SPE/One-Step Plus. The glass FRCs (Reforpost) were etched with 37% H3PO4 for 1 min and silanized (Porcelain Primer). Thereafter, they were cemented with the dual resin cement En-Force. The specimens were stored for 24 h, attached to an adapted device, and submitted to the pullout test in a universal testing machine (1 mm/min). The data were submitted to the one-way ANOVA and Tukey's test (α = 0.05). Results: G1 (30.2 ± 5.8 Kgf) displayed the highest pullout strength (p < 0.001) when compared to G2 (18.6 ± 5.8 Kgf) and G3 (14.3 ± 5.8 Kgf), which were statistically similar. Analysis of the specimens revealed that all failures occurred between the adhesive system and the root dentin (pullout of the post cement), regardless of group. Conclusion: The multiple-bottle, total-etch adhesive system provided higher pullout strength of the glass FRC when compared to the single-bottle, total-etch, and single-step self-etching adhesive systems. The null hypothesis was rejected (p < 0.001).
Resumo:
The objective of this study was to evaluate the apical leakage of retrograde cavities filled with Portland Cement (Concrebrás S/A-MG-Brazil), ProRoot MTA™ (Dentsply International, Johnson City, TN, USA) and Sealapex (Kerr Corporation, Orange, California, USA) with addition of zinc oxide (Odahcam Herpo Produtos Dentários Ltda, Rio de Janeiro, RJ, Brazil). Forty-two extracted single-rooted human teeth were decoronated and used for this study. The root canals were instrumented at 1.0mm short of the apical foramen using the step-back technique to an apical ISO size 60. The roots were obturated with gutta-percha points and sealer Sealapex (Kerr Corporation-USA) and then 3mm of each root apex was sectioned at a 90° angle. Ultrasonic retrograde preparation was performed with a diamond tip to 3mm depth and the roots were randomly divided into 3 groups according to the filling material: G1-Portland, G2-ProRoot MTA, G3- Sealapex zinc oxide-added cement. The root surfaces were covered with nail varnish up to 2mm from the apical foramen, immersed in simulated tissue fluid for 30 days, and then immersed in 0.2% Rhodamine B solution for 24 hours for evaluation of marginal leakage. The results showed mean leakage of 0.75, 0.35 and 0.35 for groups 1, 2 and 3, respectively; however, Kruskal-Wallis test revealed that there was no statistically significant difference among the results (p>0.05).
Resumo:
The aim of this paper was to evaluate the immune reconstitution of HIV-1 patients subjected to highly active antiretroviral therapy (HAART) for two years or more according to CD 45RA and CD 45RO cell count; determination of IL-2, IFN-γ, IL-4, IL-10 and TNF-α serum levels; CD 4 + T and CD 8 + T lymphocyte count; and plasma viral load (VL) determination. For this purpose, a cross sectional study was carried out in the Tropical Diseases Area, Botucatu School of Medicine, São Paulo State University, UNESP, Botucatu, São Paulo, Brazil. Between June 2001 and April 2002, 37 HIV-1 infected patients were evaluated, 13 with treatment indication but untreated (G1), 9 subjected to HAART for 5-7 months (G2), and 15 treated for two years or more (G3); both treated groups used medication regularly and without failure. Forty-nine normal individuals were studied as controls (GC-1 and GC-2). There was a tendency (p<0.10) for the predominance of two nucleoside reverse transcriptase inhibitors (NRTI) associated with one non-nucleoside reverse transcriptase inhibitor (NNRTI) regimen in G2; and two NRTI associated with a protease inhibitor (PI) in G3. Statistical differences between groups were seen for CD 45RA (G1<[G3=GC-2]; p<0.05) and CD 45RO (G1
Resumo:
Highly active antiretroviral therapy (HAART) has lead to a dramatic decrease in the morbidity of patients infected with HIV. However, metabolic side effects, including lipodystrophy and dyslipidemia, have been reported in patients treated with antiretroviral therapy (HAART). The aim of this study was to analyze the clinical and metabolic alterations and the cytokines TNF-α, IFN-γ, IL-2, IL-10 and TNF-II receptors profile in the serum of treated HIV-1-infected individuals with or without lipodystrophy. Eighty-four adult patients were analyzed, 42 females and 42 males, their mean age was 37 years old, and they received HAART for at least 15 months. These patients were ambulatory outpatients from the Infectious and Parasitary Disease Area of Botucatu School of Medicine, UNESP. Subsequently the individuals were distributed into 2 groups, G1: 42 HIV-infected individuals with lipodystrophy, and G2: 42 HIV-infected individuals without lipodystrophy. Among the antiretrovirals used, stavudine was more associated to the lipodystrophy group and zidovudine to the group without lipodystrophy. CD4, CD8, viral load, glucose, albumin, and the circulating lipid did not present any difference in the group comparison, except for triglyceride that was elevated in the lipodystrophy group and HDL which was present in low concentration in more patients of G1. The cytokines TNF-α, TNF-RII, and IL-10 profile presented high levels in the lipodystrophy group; also it was positively correlated with this group. On the other hand, IL-2 and IFN-γ presented low levels in this group. High levels of TNF-α and its receptor seem to be associated to the development of lipodystrophy in patients receiving HAART.
Resumo:
Purpose: To test the bond strength between a quartz-fiber-reinforced composite post (FRC) and a resin cement. The null hypothesis was that the bond strength can be increased by using a chairside tribochemical silica-coating system. Materials and Methods: Thirty quartz-FRCs (Light-Post) were divided into 3 groups according to the post surface treatment: G1) Conditioning with 32% phosphoric acid (1 min), applying a silane coupling agent; G2) etching with 10% hydrofluoric acid (1 min), silane application; G3) chairside tribochemical silica coating method (CoJet System): air abrasion with 30-μ SiO x-modified Al2O3 particles, silane application. Thereafter, the posts were cemented into a cylinder (5 mm diameter, 15 mm height) with a resin cement (Duo-Link). After cementation, the specimens were stored in distilled water (37°C/24 h) and sectioned along the x and y axes with a diamond wheel under cooling (Lab-cut 1010) to create nontrimmed bar specimens. Each specimen was attached with cyanoacrylate to an apparatus adapted for the microtensile test. Microtensile testing was conducted on a universal testing machine (1 mm/min). The data obtained were submitted to the one-way ANOVA and Tukey test (α = 0.05). Results: A significant influence of the conditioning methods was observed (p < 0.0001). The bond strength of G3 (15.14 ± 3.3) was significantly higher than the bond strengths of G1 (6.9 ± 2.3) and G2 (12.60 ± 2.8) (p = 0.000106 and p = 0.002631, respectively). Notwithstanding the groups, all the tested specimens showed adhesive failure between the resin cement and FRC. Conclusion: The chairside tribochemical system yielded the highest bond strength between resin cement and quartz-fiber post. The null hypothesis was accepted (p < 0.0001).
Resumo:
Purpose: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. Materials and Methods: The null hypothesis is that the fatigue resistance varies with the luting strategy. Forty blocks of In-Ceram Alumina were prepared, and one surface of each block was abraded with 110-μm aluminum oxide particles. Then, the blocks were luted to flat dentin surfaces of 40 human third molars, using 4 different luting strategies (luting system [LS]/ceramic surface conditioning [CSC]) (n=10): (G1) [LS] RelyX-Unicem/[CSC] airborne abrasion with 110-μm Al2O3 particles; (G2) [LS] One-Step + Duo-Link (bis-GMA-based resin)/[CSC] etching with 4% hydrofluoric acid + silane agent; (G3) [LS] ED-Primer + Panavia F (MDP-based resin)/[CSC] Al2O 3; (G4) [LS] Scotchbond1+RelyX-ARC (bis-GMA-based resin)/[CSC] chairside tribochemical silica coating (air abrasion with 30-μm SiO x particles + silane). After 24 h of water storage at 37°C, the specimens were subjected to 106 fatigue cycles in shear with a sinusoidal load (0 to 21 N, 8 Hz frequency, 37°C water). A fatigue survivor score was given, considering the number of the fatigue cycles until fracture. The failure modes of failed specimens were observed in a SEM. Results: G3 (score = 5.9, 1 failure) and G4 (score = 6, no failures) were statistically similar (p = 0.33) and had significantly higher fatigue resistance than G1 (score = 3.9, 5 failures) and G2 (score = 3.7, 6 failures) (p < 0.03). SEM analysis of fractured specimens of G1 and G2 showed that almost all the failures were between ceramic and cement. Conclusion: The MDP-based resin cement + sandblasting with Al2O3 particles (G3) and bis-GMA-based resin cement + tribochemical silica coating (G4), both using the respective dentin bonding systems, were the best luting protocols for the alumina ceramic. The null hypothesis was confirmed.
Resumo:
Purpose: This study evaluated the potential effects of denture base resin water storage time and an effective denture disinfection method (microwave irradiation at 650 W for 6 minutes) on the torsional bond strength between two hard chairside reline resins (GC Reline and New Truliner) and one heat-polymerizing denture base acrylic resin (Lucitone 199). Materials and Methods: Cylindrical (30 x 3.9 mm) denture base specimens (n = 160) were stored in water at 37°C (2 or 30 days) before bonding. A section (3.0 mm) was removed from the center of the specimens, surfaces prepared, and the reline materials packed into the space. After polymerization, specimens were divided into four groups (n = 10): Group 1 (G1) - tests performed after bonding; Group 2 (G2) - specimens immersed in water (200 ml) and irradiated twice (650 W for 6 minutes); Group 3 (G3) - specimens irradiated daily until seven cycles of disinfection; Group 4 (G4) - specimens immersed in water (37°C) for 7 days. Specimens were submitted to a torsional test (0.1 Nm/min), and the torsional strengths (MPa) and the mode of failure were recorded. Data from each reline material were analyzed by a two-way analysis of variance, followed by Neuman-Keuls test (p = 0.05). Results: For both Lucitone 199 water storage periods, before bonding to GC Reline resin, the mean torsional strengths of G2 (2 days - 138 MPa; 30 days - 132 MPa), G3 (2 days - 126 MPa; 30 days - 130 MPa), and G4 (2 days - 130 MPa; 30 days - 137 MPa) were significantly higher (p < 0.05) than G1 (2 days - 108 MPa; 30 days - 115 MPa). Similar results were found for Lucitone 199 specimens bonded to New Truliner resin, with G1 specimens (2 days - 73 MPa; 30 days - 71 MPa) exhibiting significantly lower mean torsional bond strength (p < 0.05) than G2 (2 day - 86 MPa; 30 days - 90 MPa), G3 (2 days - 82 MPa; 30 days - 82 MPa), and G4 specimens (2 days - 78 MPa; 30 days - 79 MPa). The adhesion of both materials was not affected by water storage time of Lucitone 199 (p > 0.05). GC reline showed a mixed mode of failure (adhesive/cohesive) and New Truliner failed adhesively. Conclusions: Up to seven microwave disinfection cycles did not decrease the torsional bond strengths between the hard reline resins, GC Reline and New Truliner to the denture base resin Lucitone 199. The effect of additional disinfection cycles on reline material may be clinically significant and requires further study. Copyright © 2006 by The American College of Prosthodontists.
Resumo:
Objective: The aim of this study was to evaluate the effect of the alcohol consumption on the periodontal bone support (PBS) in experimental periodontitis in rats. Materials and Methods: Sixty-three male rats were divided into seven groups: G1 (control); G2 (10% ethanol); G3 (nutritional control of G2); G4 (20% ethanol); G5 (nutritional control of G4); G6 (30% ethanol) and G7 (nutritional control of G6). The groups G3, G5 and G7 received controlled diets with equivalent caloric amounts to those consumed in G2, G4 and G6 respectively, with the ethanol replaced by sucrose. After anesthesia, ligatures were installed around the mandibular first molar, leaving the contralateral teeth unligated. After 8 weeks, the rats were killed and their mandibles were radiographed to measure the percentage of PBS on the distal aspect. Results: The intragroup analyses showed that presence of ligatures induced periodontitis (p<0.05). Unligated groups did not show significant differences among the percentages of PBS (p=0.1969). However, in ligated groups the rats that received alcohol (G2:48.71%±3.88; G4:47.66%±2.54; G6:47.32%±3.24) and the nutritional control group associated with a high concentration of ethanol (G7:47.40%±3.24) presented a significantly lower percentage of PBS than the other groups (G1:52.40%±2.75; G3:52.83%±2.41; G5:50.85%±4.14). Conclusions: These results demonstrated that alcohol consumption in rats may result in a direct effect on alveolar bone loss and increased development of periodontitis. In addition, they suggest that heavy caloric consumption of ethanol may also present an indirect effect on periodontal tissue as a consequence of malnutrition.
Resumo:
Laboratory profile of young ovines was studied in order to evaluate and compare their antiserum production from natural and Cobalt-60 irradiated Crotalus durissus terrificus (C.d.t.) venoms. The parameters analyzed included complete blood count, and urea, creatinine, aspartate aminotransferase, total proteins, albumin and globulin serum measurements. Three groups of six animals each were used. Group 1 (G1) received natural C.d.t. venom; Group 2 (G2) received irradiated C.d.t. venom; and Group 3 (G3) was used as control and did not receive venom, only adjuvants, using seven venom inoculations. During the experimental period, animals were fortnightly weighed. According to clinical and weight evaluation, sheep in post-weaning phase showed no changes in their physiological profiles but had excellent weight gain. The parameters analyzed were not statistically different (p<5%) among the groups tested. The hyperimmunization process was successfully accomplished with the production of specific antibodies against Crotalus durissus terrificus venom. Results bring a new possibility of utilizing ovines in the commercial production of anticrotalic serum, which may be used to treat human and animal envenomation. Its production cost may be reduced by subsequent use of hyperimmunized sheep for human consumption.
Resumo:
The purpose of this study was to test the hypothesis that mechanical polishing methods of ceramic surfaces allow similar superficial roughness to that of glazed surfaces. Twenty-five Vitadur Alpha ceramic discs (5 mm x 2 mm) were prepared according to the manufacturer's specifications. All specimens were glazed and randomly assigned to 5 groups (n=5), according to finishing and polishing protocols: G1: glazed (control); G2: diamond bur finishing; G3: G2 + silicon rubber tip polishing; G4: G3 + felt disc/diamond polishing paste; G5: G3 + felt disc impregnated with fine-particle diamond paste. Next, surface roughness means (Ra - μm) were calculated. Qualitative analysis was made by scanning electron microscopy. Surface roughness data were submitted to ANOVA and Tukey's test at 5% significance level. G1 and G4 were statistically similar (p>0.05). G2 presented the highest roughness means (p<0.05) followed by groups G3, G5, G4 and G1 in a decreasing order. The hypothesis was partially confirmed as only the mechanical polishing (G4) produced similar superficial roughness to that of surface glazing, although finishing and polishing are technically critical procedures.
Resumo:
The aim of this study was to evaluate the pre-emptive effect of epidural ketamine S (+) (SK) or racemic ketamine (RK) administration, in post-incisional pain in horses. Were used in a blinded, randomized experimental study, sixteen mixed breed mares, 6±2 years old, weighting 273.2±42.0 kg. An epidural catheter was inserted 24 hours before the trials. The thigh region was shaved bilaterally, and mechanical cutaneous sensibility was measured using von Frey filaments (T-30). Using the left side as the control one, local anesthesia was performed at the right side. Twenty-five minutes later, SK was injected in G1 or RK in G2 through the epidural catheter. Five minutes after the ketamine injection, a 10 cm skin incision was made on the right side, and then sutured. Mechanical post-incisional pain was measured using von Frey filaments, at 1, 3 and 5 cm around the incision at 15 minutes intervals, for 2 hours, then 4, 6 and 8 hours after suturing. No changes were observed in the heart and respiratory rate and rectal temperature among groups or times of each group. Hind limb ataxia was observed in 62.5% and 12.5% of G1 and G2 respectively. SK and RK reduced cutaneous sensibility in the right and the left sides to mechanical postincisional pain during all time of experiment. Epidural SK and RK produce similar post-incisional analgesic effects, did not interfere in the cardio-respiratory parameters. The SK induces more intense ataxia in mares and presents a larger analgesic potency in the first 60 minutes after the administration.
Resumo:
Purpose: To evaluate and correlate in the rabbit the possible changes caused by mitomycin C under the scleral flap in the ciliary epithelium with transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Methods: The eyes of 32 albino rabbits were studied and divided in 4 experimental groups. The right eye (RE) was intended for the experimental groups and the left eye (LE) for the controls. Group I (G1) was formed by 8 eyes that received 0,5 mg/ml of mitomycin C under the scleral flap and were examined after 15 days. Group II (G2) differed from G1 only in the time of the exam, after 30 days. Group III (G3) was formed by 8 eyes that received 0,2 mg/ml of mitomycin C under the scleral flap and were examined after 15 days. Group IV (G4) differed from group 3 just in the time of the exam, after 30 days. In each eye the internal ciliary epithelium were examined with TEM. Results: The following changes in the internal ciliary epithelium were observed in groups G2, G3, and G4 with TEM: discontinuous and irregular basement membrane, more irregular and electron-dense nucleous, enlargement among interdigitation, edematous mitochondria and myelin figures. These alterations were not found in all the animals of the groups. Group G 1 did not present alterations. Roughness in groups G 1, G2, G3 and G4 were observed with SEM. In groups G 1 and G2 continuity solutions were also observed. Conclusion: Mitomycin C in 0,2 mg/ml and 0,5 mg/ml concentrations caused changes in the internal ciliary epithelium 15 and 30 days after, with TEM and SEM. There was no correlation between dosage, time and with TEM and SEM.