1000 resultados para NERVE GUIDE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selective reinnervation of peripheral targets after nerve injury might be assessed by injecting a first tracer in a target before nerve injury to label the original neuronal population, and applying a second tracer after the regeneration period to label the regenerated population. However, altered uptake of tracer, fading, and cell death may interfere with the results. Furthermore, if the first tracer injected remains in the target tissue, available for 're-uptake' by misdirected regenerating axons, which originally innervated another region, then the identification of the original population would be confused. With the aim of studying this problem, the sciatic nerve of adult rats was sectioned and sutured. After 3 days, to allow the distal axon to degenerate avoiding immediate retrograde transport, one of the dyes: Fast Blue (FB), Fluoro-Gold (FG) or Diamidino Yellow (DY), was injected into the tibial branch of the sciatic nerve, or in the skin of one of the denervated digits. Rats survived 2-3 months. The results showed labelled dorsal root ganglion (DRG) cells and motoneurones, indicating that late re-uptake of a first tracer occurs. This phenomenon must be considered when the model of sequential labelling is used for studying the accuracy of peripheral reinnervation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le système nerveux périphérique est responsable de la transmission des impulses motrices, ainsi que de la réception des afférences sensorielles. Les lésions traumatiques des nerfs périphériques conduisent à une impotence fonctionnelle qui peut être dévastant, notamment chez les travailleurs manuels,. La récupération fonctionnelle est donc le but principal dans chirurgie des nerfs périphériques. Malheureusement, une suture directe des moignons nerveux est souvent impossible dans le contexte des traumatismes complexes qui surviennent lors des accidents. La suture nerveuse par interposition d'autogreffe reste le gold standard dans la pratique chirurgicale mais nécessite le sacrifice d'un nerf donneur, avec dysesthésie et possibles douleurs neuropathiques conséquentes. Alternativement, des guides tubulaires pour les nerfs peuvent être utilisées si le gap nerveux est inférieur à 3 cm. Plusieurs guides résorbables en collagène sont approuve en Europe et aux Etas Unis (FDA). Dans cette étude, des conduits de collagène ont été associe a des cellules régénératives (cellules souches adultes) comme stratégie supplémentaire de régénération. Une fois testé le rapport des cellules avec le biomatériau (NeuraGen® nerve guides) in vitro, une étude in vivo dans le rat a été effectuée. Les différents groupes de conduits ont été supplémentés respectivement avec Schwann cells (SC); avec cellules souches adultes dérivées de la moelle épinière, différentiées en cellules "Schwann-like" (dMSC); avec cellules souches adultes dérivées de la graisse, différentiées en cellules "Schwann-like" (dASC). Un groupe de conduits avec du milieu de culture sans cellules a été utilisé comme group control. Les conduits ont été utilisés pour combler un gap de 1cm dans un model de section totale du nerf sciatique chez le rat. Deux semaines post implantation, une analyse immuno-histochimique a été effectuée pour évaluer la régénération axonales et l'infiltration de cellules de Schwann au niveau du conduit. Les cellules ont montré une adhérence efficace aux parois de collagène. En particulier, les cellules de Schwann ont montré une amélioration significative au niveau du sprouting distale. Par contre, aucune différence significative n'a été remarquée entre les groupes pour le sprouting axonale proximal. De plus, si les cellules souches ont montré un pattern de sprouting diffus, les cellules de Schwann ont par contre garanti un cône de croissance typique, associé a une affinité remarquable pour les parois de collagène. NeuraGen® guides pourraient donc être un moyen adapté a l'association avec la thérapie cellulaire en raison de la bonne adhérence des cellules au biomatériau. Des modifications de surface dans le but d'améliorer la performance neurotrophique cellulaire in vivo (e.g. peptides de matrice extracellulaire) pourront être utilisées dans des applications futures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Définir la maltraitance. Reconnaître une situation de maltraitance. L'évaluation. Agir. Suites d'un signalement et prise en charge de l'enfant et de sa famille. Le référence maltraitance: rôle et interventions possibles. La prévention en quelques mots. Quelques adresses utiles dans le canton du Jura. Quelques ouvrages de référence. Annexes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variante(s) de titre : Le Guide Sam pour l'expansion économique française dans le Levant

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral nerve injury is typically associated with long-term disturbances in sensory localization, despite nerve repair and regeneration. Here, we investigate the extent of correct reinnervation by back-labeling neuronal soma with fluorescent tracers applied in the target area before and after sciatic nerve injury and repair in the rat. The subpopulations of sensory or motor neurons that had regenerated their axons to either the tibial branch or the skin of the third hindlimb digit were calculated from the number of cell bodies labeled by the first and/or second tracer. Compared to the normal control side, 81% of the sensory and 66% of the motor tibial nerve cells regenerated their axons back to this nerve, while 22% of the afferent cells from the third digit reinnervated this digit. Corresponding percentages based on quantification of the surviving population on the experimental side showed 91%, 87%, and 56%, respectively. The results show that nerve injury followed by nerve repair by epineurial suture results in a high but variable amount of topographically correct regeneration, and that proportionally more neurons regenerate into the correct proximal nerve branch than into the correct innervation territory in the skin

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effect of optic nerve disease, hence retinal ganglion cell loss, on non-visual functions related to melanopsin signalling. Test subjects were patients with bilateral visual loss and optic atrophy from either hereditary optic neuropathy (n = 11) or glaucoma (n = 11). We measured melatonin suppression, subjective sleepiness and cognitive functions in response to bright light exposure in the evening. We also quantified the post-illumination pupil response to a blue light stimulus. All results were compared to age-matched controls (n = 22). Both groups of patients showed similar melatonin suppression when compared to their controls. Greater melatonin suppression was intra-individually correlated to larger post-illumination pupil response in patients and controls. Only the glaucoma patients demonstrated a relative attenuation of their pupil response. In addition, they were sleepier with slower reaction times during nocturnal light exposure. In conclusion, glaucomatous, but not hereditary, optic neuropathy is associated with reduced acute light effects. At mild to moderate stages of disease, this is detected only in the pupil function and not in responses conveyed via the retinohypothalamic tract such as melatonin suppression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interpretation of complex DNA profiles is facilitated by a Bayesian approach. This approach requires the development of a pair of propositions: one aligned to the prosecution case and one to the defense case. This note explores the issue of proposition setting in an adversarial environment by a series of examples. A set of guidelines generalize how to formulate propositions when there is a single person of interest and when there are multiple individuals of interest. Additional explanations cover how to handle multiple defense propositions, relatives, and the transition from subsource level to activity level propositions. The propositions depend on case information and the allegations of each of the parties. The prosecution proposition is usually known. The authors suggest that a sensible proposition is selected for the defense that is consistent with their stance, if available, and consistent with a realistic defense if their position is not known.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In imaging diagnosis, redundant nerve roots of the cauda equina are characterized by the presence of elongated, enlarged and tortuous nerve roots in close relationship with a high-grade lumbar spinal canal stenosis. This is not an independent entity, but it is believed to be a consequence of the chronic compression at the level of the lumbar canal stenosis and thus may be part of the natural history of lumbar spinal stenosis. The present paper is aimed at reviewing the histopathological, electrophysiological and imaging findings, particularly at magnetic resonance imaging, as well as the clinical meaning of this entity. As the current assessment of canal stenosis and root compression is preferably performed by means of magnetic resonance imaging, this is the imaging method by which the condition is identified. The recognition of redundant nerve roots at magnetic resonance imaging is important, particularly to avoid misdiagnosing other conditions such as intradural arteriovenous malformations. The literature approaching the clinical relevance of the presence of redundant nerve roots is controversial. There are articles suggesting that the pathological changes of the nerve roots are irreversible at the moment of diagnosis and therefore neurological symptoms are less likely to improve with surgical decompression, but such concept is not a consensus.