855 resultados para Micro Rotary Ultrasonic Machining
Resumo:
This study aimed at evaluating the antisepsis of the root canal system (RCS) and periapical region (PR) provided by rotary instrumentation associated with chlorhexidine + calcium hydroxide as intracanal medicament. Chronic periapical lesions were induced in 26 pre-molar roots in two dogs. After microbiological sampling, automatic instrumentation using the Profile system and irrigation with 5.25% sodium hypochlorite solution, with a final rinse of 14.3% EDTA followed by profuse irrigation with physiological saline were carried out in 18 root canals. After drying the canals, a paste based on calcium hydroxide associated with a 2% chlorhexidine digluconate solution was placed inside them. After 21 days, the medication was removed, leaving the root canals empty and coronally sealed. After 96 hours, a final microbiological sample was obtained, followed by histomicrobiological processing by the Brown & Brenn method. Eight untreated root canals represented the control group (C-G). Based on the Mann-Whitney test at a confidence level of 5% (p < 0.05), the procedures of antisepsis used offered significant efficacy (p < 0.05) resulting in 100.0% of the canals free of microorganisms. In the C-G, an elevated incidence of various microbial morphotypes was confirmed in all sites of the RCS, with the presence of microbial colonies in the periapical region. In contrast, the experimental group showed a similar pattern of infection in the RCS, although less intense and a reduced level of periapical infection (p < 0.05). It was concluded that adequate instrumentation followed by the application of calcium hydroxide + chlorhexidine offered significant elimination of microorganisms.
Resumo:
The use of the nasal route for drug delivery has attracted much interest in recent years in the pharmaceutical field. Local and principally systemic drug delivery can be achieved by this route of administration. But the nasal route of delivery is not applicable to all drugs. Polar drugs and some macromolecules are not absorbed in sufficient concentration due to poor membrane permeability, rapid clearance and enzymatic degradation into the nasal cavity. Thus, alternative means that help overcome these nasal barriers are currently in development. Absorption enhancers such as phospholipids and surfactants are constantly used, but care must be taken in relation to their concentration. Drug delivery systems including liposomes, cyclodextrins, micro- and nanoparticles are being investigated to increase the bioavailability of drugs delivered intranasally. This review article discusses recent progress and specific development issues relating to colloidal drug delivery systems in nasal drug delivery. © 2006 Bentham Science Publishers Ltd.
Resumo:
The aim of this study was to evaluate the antiseptic efficacy of rotary instrumentation associated with calcium hydroxide-based pastes prepared with different vehicles and antiseptics. Chronic periapical lesions were experimentally induced in 72 premolar root canals of four dogs. Under controlled asepsis, after initial microbiological sampling (A1), the root canals were instrumented using the ProFile system in conjunction with 5.25% sodium hypochlorite and the intracanal medication was placed. Four experimental groups were formed according to the pastes used: group 1- Calen (n=18), group 2- Calen+CPMC (n=20), group 3- Ca(OH)2 p.a.+ anaesthetic solution (n=16) and group 4- Ca(OH)2 p.a.+ 2% chlorhexidine digluconate (n=18). After 21 days, the pastes were removed; the canals were emptied and 96 hours later a second microbiological sample was obtained (A2). The incidence of positive microbiological cultures and the number of cfus in stages A1 and A2 were compared statistically by the Wilcoxon test while the influence of the different treatments in intracanal infection was evaluated by Kruskal-Wallis test at 5% significance level (p<0.05). Large numbers of strict and facultative anaerobes, and viridans group streptococci were found in 100% of root canals of A1 samples. Among A2 samples, all treatments showed significant reduction of cfus and positive cultures (p<0.05), but only groups 3 and 4 showed 100% of root canals free of microorganisms. Rotary instrumentation plus NaOCl 5.25% associated with intracanal medication produced a drastic reduction or elimination of intracanal microbiota, whose performance was not influenced by the nature of the vehicle or the antiseptic added to the Ca(OH)2 p.a.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate the distribution of microorganisms in the root canal system (RCS) and periapical lesions of dogs' teeth after rotary instrumentation and placement of different calcium hydroxide [Ca(OH)2]-based intracanal dressings. MATERIALS AND METHODS: Chronic periapical lesions were experimentally induced in 80 premolar roots of four dogs. Instrumentation was undertaken using the ProFile rotary system and irrigation with 5.25% sodium hypochlorite. The following Ca(OH) 2-based pastes were applied for 21 days: group 1 - Calen (n=18); group 2 - Calen+CPMC (n=20); group 3 - Ca(OH)2 p.a. + anaesthetic solution (n=16) and group 4 - Ca(OH)2 p.a.+ 2% chlorhexidine digluconate (n=18). Eight root canals without endodontic treatment constituted the control group. Histological sections were obtained and stained with Brown & Brenn staining technique to evaluate the presence of microorganisms in the main root canal, ramifications of the apical delta and secondary canals, apical cementoplasts, dentinal tubules, areas of cemental resorption and periapical lesions. The results were analyzed statistically by the Mann-Whitney U test (p<0.05). RESULTS: The control group showed the highest prevalence of microorganisms in all sites evaluated. Gram-positive cocci, bacilli and filaments were the most frequent morphotypes. Similar microbial distribution patterns in the RCS and areas of cementum resorption were observed in all groups (p>0.05). The percentage of RCS sites containing microorganisms in groups 1, 2, 3, 4 and control were: 67.6%, 62.5%, 78.2%, 62.0% and 87.6%, respectively. CONCLUSION: In conclusion, the histomicrobiological analysis showed that the rotary instrumentation and the different calcium hydroxide pastes employed did not effectively eliminate the infection from the RCS and periapical lesions. However, several bacteria seen in the histological sections were probably dead or were inactivated by the biomechanical preparation and calcium hydroxide-based intracanal dressing.
Resumo:
Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.
Resumo:
Informatics evolution presently offers the possibility of new technique and methodology development for studies in all human knowledge areas. In addition, the present personal computer capacity of handling a large volume of data makes the creation and application of new analysis tools easy. This paper aimed the application of a fuzzy partition matrix to analyze data obtained from the Landsat 5 TMN sensor, in order to elaborate the supervised classification of land use in Arroio das Pombas microbasin in Botucatu, SP, Brazil. It was possible that one single training area present input in more than one covering class due to weight attribution at the signature creation moment. A change in the classification result was also observed when compared to maximum likelihood classification, mainly when related to bigger uniformity and better class edges classification.
Resumo:
PURPOSE: This review of the literature intends to evaluate the effect of brushes with high frequency motion when compared with manual toothbrushes regarding the indices of plaque and gingival bleeding. METHODS: Patients presenting gingivitis and/or chronic periodontitis were evaluated in addition to patients having osseointegrated implants and fixed orthodontic appliances. Pertinent literature was reviewed to select articles according to previously defined inclusion criteria. RESULTS: In the assessed studies results showed significant decreases in plaque and gingival indices by utilization of both types of brushes. However, in the selected studies where sonic brushes were tested in orthodontic and dental implant patients there was a more significant decrease in the indices. Furthermore, there was no indication of gingival recession attributed to product use. CONCLUSION: Future studies with a more homogeneous methodology and better experiment designs will be needed.
Resumo:
The aim of this paper consists in presenting a method of simulating the warpage in 7xxx series aluminium alloy plates. To perform this simulation finite element software MSC.Patran and MSC.Marc were used. Another result of this analysis will be the influence on material residual stresses induced on the raw material during the rolling process upon the warpage of primary aeronautic parts, fabricated through machining (milling) at Embraer. The method used to determinate the aluminium plate residual stress was Layer Removal Test. The numerical algorithm Modified Flavenot Method was used to convert layer removal and beam deflection in stress level. With such information about the level and profile of residual stresses become possible, during the step that anticipate the manufacturing to incorporate these values in the finite-element approach for modelling warpage parts. Based on that warpage parameter surely the products are manufactured with low relative vulnerability propitiating competitiveness and price. © 2007 American Institute of Physics.
Resumo:
Several studies have reported the benefits of sonic and/or ultrasonic instrumentation for root debridement, with most of them focusing on changes in periodontal clinical parameters. The present study investigated possible alterations in the tensile bond strength of crowns cemented with zinc phosphate cement to natural teeth after ultrasonic instrumentation. Forty recently extracted intact human third molars were selected, cleaned and stored in physiologic serum at 4°C. They received standard preparations, at a 16° convergence angle, and AgPd alloy crowns. The crowns were cemented with zinc phosphate cement and then divided into four groups of 10 teeth each. Each group was then subdivided into two subgroups, with one of the subgroups being submitted to 5,000 thermal cycles ranging from 55 ± 2 to 5 ± 2°C, while the other was not. Each group was submitted to ultrasonic instrumentation for different periods of time: group 1 - 0 min (control), group 2 - 5 min, group 3 - 10 min, and group 4 - 15 min. Tensile bond strength tests were performed with an Instron testing machine (model 4310). Statistical analysis was performed using ANOVA and Tukey's test at the 5% level of significance. A significant reduction in the tensile bond strength of crowns cemented with zinc phosphate and submitted to thermal cycles was observed at 15 min (196.75 N versus 0 min = 452.01 N, 5 min = 444.23 N and 10 min = 470.85 N). Thermal cycling and ultrasonic instrumentation for 15 min caused a significant reduction in tensile bond strength (p < .05).
Resumo:
The α-SiAlON ceramic cutting tool insert is developed. Silicon nitride and additives powders are pressed and sintered in the form of cutting tool inserts at temperature of 1900 °C. The physics and mechanical properties of the inserts like green density, weight loss, relative density, hardness and fracture toughness are evaluated. Machining studies are conducted on grey cast iron workpiece to evaluate the performance of α-SiAlON ceramic cutting tool. In the paper the cutting tool used in higher speed showed an improvement in the tribological interaction between the cutting tools and the grey cast iron workpiece resulted in a significant reduction of flank wear and roughness, because of better accommodation and the presence of the graphite in gray cast iron. The above results are discussed in terms of their affect at machining parameters on gray cast iron.
Turning of compacted graphite iron using commercial tiN coated Si 3N4 under dry machining conditions
Resumo:
Due to their high hardness and wear resistance Si3N4 based ceramics are one of the most suitable cutting tool materials for machining hardened materials. Therefore, their high degree of brittleness usually leads to inconsistent results and sudden catastrophic failures. Improvement of the functional properties these tools and reduction of the ecological threats may be accomplished by employing the technology of putting down hard coatings on tools in the state-of-the-art PVD processes, mostly by improvement of the tribological contact conditions in the cutting zone and by eliminating the cutting fluids. However in this paper was used a Si3N4 based cutting tool commercial with a layer TiN coating. In this investigation, the performance of TiN coating was assessed on turning used to machine an automotive grade compacted graphite iron. As part of the study were used to characterise the performance of cutting tool, flank wear, temperature and roughness. The results showed that the layer TiN coating failed to dry compacted graphite iron under aggressive machining conditions. However, using the measurement of flank wear technique, the average tool life of was increased by VC=160 m/min.The latter was also observed using a toolmakers microscope and scanning electron microscopy (SEM).
Resumo:
This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to case test this test protocol, a development platform with reduced power for DVR (Dynamic Voltage Restorer), the Micro-DVR, was tested, and results were discussed based on voltage disturbances standards. ©2008 IEEE.
Resumo:
Using the motivograma and interviews the degree of motivation of the survey participants was defined as satisfactory. On one hand there is satisfaction with the physiological needs, self-esteem and self confidence, on the other there is high dissatisfaction with the association and self-realization, justifying the request for strengthening the membership and performance improvements in the research area. Linking up security and association with the other ones group protection sentiments and work environment dependence sentiments prevail. It was concluded that: (1) Those satisfied ones declare that they are safe, protected and with good self-esteem doing their teaching work. The ones dissatisfied with the non-group belonging demonstrate dissatisfaction with the self-realization and expose their difficulties with social ties and the lack of integration in the teaching work. (3) The degree of motivation satisfactory is related to the satisfaction of basic needs, located in the first steps of Maslow's hierarchy. Accepting that the changes in higher education require motivated behaviors, the question arises: how can the motivation in teaching work be possible if the majority of organizations do not find a way to deal with the person of the Professor? Finally, the context of work is predominant in the provision of job satisfaction in teaching.
Resumo:
Incluye Bibliografía
Resumo:
A green ceramic tape micro heat exchanger was developed using LTCC technology. The device was designed by using a CAD software and 2D and 3D simulations using a CFD package (COMSOL Multiphysics) to evaluate the fluid behavior in the microchannels. The micro heat exchanger is composed of five thermal exchange plates in cross flow arrangement and two connecting plates; heat exchanger dimensions are 26 × 26 × 6 mm3. Preliminary tests were carried out to characterize the device both in atmospheric pressure and in vacuum. The same techniques used in vacuum technology were applied to check the rotameters and to prevent device leakages. Thermal performance of the micro heat exchanger was experimentally tested. © 2009 Elsevier B.V. All rights reserved.